Honeywell Lyric T6R Installation Instructions

Lyric T6R Smart Thermostat
1
Turn OFF the power and remove the old thermostat
EN
Install Guide
Compatible with 24-230V on/off and OpenTherm® appliances such as gas boilers, combi-boilers and heat pump. Also works with zone valve applications but not with
Manufactured for and on behalf of the Environmental and Energy Solutions Division of Honeywell Technologies Sàrl, ACS-ECC EMEA, Z.A. La Pièce 16, 1180 Rolle, Switzerland by its Authorised Representative Honeywell Inc.
Need help? For assistance please visit: getconnected.honeywell.com
Honeywell Control Systems Ltd. Skimped Hill Lane, Bracknell, Berkshire RG12 1EB
Approvals
Conforms to protection requirements of the following directives: EMC: 2014/30/EU, LVD: 2014/35/EU and R&TTE: 1995/5/EC. Hereby, Honeywell, declares that this
thermostat is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU.
ErP: Class V (+3%), (EU) 811/2013 Receiver Category: 2
Must be installed by a competent person!
Read these instructions carefully. Failure to follow these instructions can damage the product or cause a hazardous condition.
electric heating (240V).
To ensure your safety, always make sure mains power is switched OFF before accessing wiring.
In case of removing the old thermostat be aware that the existing wiring will no longer be used.
The T6R thermostat should not be placed near draughts, in direct sunlight or near heat sources.
WEEE Directive 2012/19/EC Waste Electrical and Electronic Equipment directive
At the end of the product life dispose of the packaging and product in a corresponding recycling centre. Do not dispose of the unit with the usual domestic refuse. Do not burn the product.
Prepare Receiver Box
2
Before installation of the Receiver Box
Find a suitable location near to the boiler. Leave at least 30cm distance from any metal objects including wallboxes and boiler housing.
Needed during installation:
Cable with 2 wires from the boiler to Receiver Box.
The Receiver Box requires 230V power
for installation
Loosen the front
screw to remove cover or tighten it when the cover is back in place.
Install the
3
A) Wall box or Rear Wiring
Receiver Box
Hinge open the terminal block flap to access the cables and wall box screw holes.
Max 6 mm
min 0.25mm2 max 1.5mm
Please refer to the wiring diagrams over the page
B) Surface wiring
Use the cable clamps to secure the surface wiring.
Locate the hinges at the top of the cover and
2
wall plate, close the cover and secure with the screw.
4
Install the Lyric T6R thermostat
1.70 m
Complete
5
Turn ON mains power to the Heating Appliance and Receiver Box.
After powering up both devices the green LED is on.
installation
Reset
Push the button to check if the boiler switches on. Button lights green.
After power up, SETUP is displayed on the thermostat’s screen.
Choose the appropriate plug. Place the thermostat on an even, horizontal surface and plug it in.
To rebind the units, reset the Receiver box, then press the button for 3 seconds. The LED on the receiver box will blink yellow to indicate the box is in binding mode. On the thermostat press for 5 seconds to enter the advanced menu. Navigate to Binding, clear the current binding then bind the device again.
6
Set Up and configuration
***SETUP****
1) Touch to begin setting up the thermostat.
SETUP
*CLOCK
3) Set the clock format, time and date.
SETUP
**LANGUAGE**
2) Select your language.
SETUP
CONFIGURE W
4) Touch to finalise setup.
( to setup using the App is currently unsupported)
Once setup is completed, if you need to change more settings go to the advanced menu. To access the advanced menu press for 5 seconds.
In the advanced menu the following settings can be adjusted:
Menu Item Default Options
LANGUAGE
OPENTHERM
CYCLE RATE
MINIMUM ON TIME
HEAT RANGE
SCHEDULE OPTIONS
OPTIMISE
CLOCK
LOW LOAD CONTROL
TEMPERATURE OFFSET
BINDING
RESET
FAILSAFE
English
-
6
1 minute
Min = 5.0 Max = 37.0
Daily
Opt. start on Opt. stop off
Format: 24h Time: --:-­Date: 01/09/16
ON 0 = OFF, 1 = ON
0.0ºC 1.5 ºC to 1.5ºC
-
-
OFF
0 = English, 1 = Français, 2 = Español 3 = Deutsch, 4 = Nederlands, 5 = Italiano
OpenTherm boiler data when available
3, 6, 9 or 12
1, 2, 3, 4 or 5 minutes
Min: 5ºC to 21ºC, Max: 21ºC to 37ºC
1 = Daily schedule, 2 = 5+2 days schedule
Opt. start: 0 = OFF, 1 = ON, 2 = Delayed start Opt. stop: 0 = OFF, 1 = ON
Clock format: 1 = 12h, 2 = 24h Setup time and date
Bind , check RF and clear bind.
Factory, schedule, WiFi and HomeKit reset
0 = OFF, 1 = ON
AM
PM
*1234
AM
PM
*****230****
1 2 3 4 5 6
5 sec
AM
PM
Wiring Diagrams
A) Wiring for basic 230V boiler
Boiler
Receiver Box
B) Wiring for Combi boiler
Lyric
Receiver Box
T1 T2
Boiler
C) Wiring for OpenTherm boiler
Receiver Box
Boiler
T1 T2
D) Wiring for two-port zone valve or S-plan
For other wiring diagrams visit:
Receiver Box
V4043
http://www.honeywelluk.com/ professional-zone/resource-centre/ WiringDiagrams/
32308181-001 C