Honeywell Lyric T6 Installation Instructions

1
Turn OFF the power and remove the old thermostat
T6 SMART THERMOSTAT
Compatible with 24-230V on/off and OpenTherm®
Need help? For assistance please visit: getconnected.honeywell.com
Honeywell Control Systems Ltd., Skimped Hill Lane, Bracknell, Berkshire, RG12 1EB
Approvals
Conforms to protection requirements of the following directives: EMC: 2014/30/EU, LVD: 2014/35/EU and RED: 2014/53/EU. Hereby, Honeywell, declares that this thermostat is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU. The full text of the EU Declaration of Conformity is available at the following Internet address: http://hwll.co/DoC
Wi-Fi (2.4GHz): Max Power 100mW, 2.4–2.458GHz ErP: Class V (+3%), (EU) 811/2013
Must be installed by a competent person!
Read these instructions carefully. Failure to follow these instructions can damage the product or cause a hazardous condition.
appliances such as gas boilers, combi-boilers and heat pump. Also works with zone valve applications but not with electric heating (240V).
To ensure your safety, always make sure mains power is switched OFF before accessing wiring.
Before removing the old thermostat take a picture of the old thermostat’s wiring as reference then proceed to installation.
1.2-1.5 m
The T6 thermostat should not be placed near draughts, in direct sunlight or near heat sources. It should be at least 1.2 - 1.5 meters from the floor.
Maximum cable length between Receiver box and thermostat:
15m for 0.5mm² cable or 20m for 1.0mm² cable.
WEEE Directive 2012/19/EC Waste Electrical and Electronic Equipment directive
At the end of the product life dispose of the packaging and product in a corresponding recycling centre. Do not dispose of the unit with the usual domestic refuse. Do not burn the product.
Prepare Receiver Box
2
Before installation of the Receiver Box
Find a suitable location near to the boiler.
Needed during installation:
Cable with 2 wires from the Receiver Box (R4H810A) to thermostat.
Cable with 2 wires from the boiler to Receiver Box.
The Receiver Box requires 230V power
Loosen the front
screw to remove cover or tighten it when the cover is back in place.
Install the
3
A) Wall box or Rear Wiring
Receiver Box
Hinge open the terminal block flap to access the cables and wall box screw holes.
Max 6 mm
min 0.25mm2 max 1.5mm
Please refer to the wiring diagrams over the page
B) Surface wiring
Use the cable clamps to secure the surface wiring.
C) Replace the cover
Locate the hinges at the top of the cover and
2
wall plate, close the cover and secure with the screw.
Install the
4
Remember to use the same wires that you connected to the Receiver Box when connecting to the thermostat.
A) B)
T6 thermostat
Using a screwdriver open wallplate terminal cover to connect wires
Optional Coverplate installation
Connect 2 thermostat wires to the T and T terminals and close cover.
T
T
T
T
S S
Complete
5
Turn ON mains power to the Heating Appliance and Receiver Box.
After powering up both devices the green LED is on.
installation
Push the button to check if the boiler switches on. Button lights green.
After power up, SETUP is displayed on the thermostat’s screen.
Attach the thermostat to the
C)
wallplate when finished.
32308180-017 A
6
Set Up and configuration
Once setup is completed, if you need to change more settings go to the advanced menu. To access the advanced menu press for 5 seconds.
AM
PM
*1234
AM
PM
*****230****
1 2 3 4 5 6
AM
PM
***SETUP****
1) Touch to begin setting up the thermostat.
SETUP
*CLOCK
3) Set the clock format, time and date.
SETUP
**LANGUAGE**
2) Select your language.
SETUP
CONFIGURE W
4) Touch to finalise setup.
( to setup using the App is currently unsupported)
In the advanced menu the following settings can be adjusted:
Menu Item Default Options
LANGUAGE
OPENTHERM
CYCLE RATE
MINIMUM ON TIME
HEAT RANGE
SCHEDULE OPTIONS
EXTERNAL SENSOR
OPTIMISE
CLOCK
LOW LOAD CONTROL
TEMPERATURE OFFSET
RESET
FAILSAFE
English
-
6
1 minute
Min = 5.0ºC Max = 35.0ºC
Daily
No sensor 0 = No sensor, 1 = Room sensor
Opt. start OFF Opt. stop OFF
Format: 24h Time: --:-­Date: 01/09/16
ON 0 = OFF, 1 = ON
0.0ºC 1.5 ºC to 1.5ºC
-
OFF
0 = English, 1 = Français, 2 = Español 3 = Deutsch, 4 = Nederlands, 5 = Italiano
OpenTherm boiler data when available
3, 6, 9 or 12
1, 2, 3, 4 or 5 minutes
Min: 5ºC to 21ºC, Max: 21ºC to 35ºC
1 = Daily schedule, 2 = 5+2 days schedule
Opt. start: 0 = OFF, 1 = ON, 2 = Delayed start Opt. stop: 0 = OFF, 1 = ON
Clock format: 1 = 12h, 2 = 24h Setup time and date
Factory, schedule, WiFi and HomeKit reset
0 = OFF, 1 = ON
5 sec
Wiring Diagrams
A) Basic 230V boiler B) Combi boiler
Receiver Box
Thermostat
s s
Boiler
Receiver Box
Thermostat
s s
T1 T2
Boiler*
C) OpenTherm boiler D) Two-port zone valve or S-plan
Receiver Box
Thermostat
Receiver Box
s s
T1 T2
Boiler*
For other wiring diagrams visit:
www.honeywelluk.com/ professional-zone/resource-centre/ WiringDiagrams/
V4043
Thermostat
s s
* See boiler specifications for correct terminals
Manufactured for and on behalf of the Environmental and Energy Solutions Division of Honeywell Technologies Sàrl, ACS-ECC EMEA, Z.A. La Pièce 16, 1180 Rolle, Switzerland by its Authorised Representative Honeywell Inc.