READ AND SAVE THESE SAFETY
INSTRUCTIONS BEFORE USING
THIS FAN
When using electrical appliances,
basic precautions should always
be followed to reduce the risk of
fire, electric shock, and injury to
persons, including the following:
FOR US MODELS ONLY – This product
employs overload protection (fuse). A blown
fuse indicates an overload or short-circuit
situation. If the fuse blows, unplug the product
from the outlet. Replace the fuse as per the
user servicing instructions (follow product
marking for proper fuse rating) and check
the product. If the replacement fuse blows,
a short-circuit may be present and the
product should be discarded or returned to an
authorized service facility for examination and/
or repair.
1. Use this fan only as described in this
manual. Other use not recommended as
it may cause fire, electric shock or injury
to persons.
2. This product is intended for household
use ONLY and not for commercial,
industrial or outdoor use.
3. To protect against electric shock, do not
place fan in window, immerse unit, plug
or cord in water or spray with liquids.
4. This appliance has a polarized plug
(one blade is wider than the other). To
reduce the risk of shock, this plug is
intended to fit only one way in a polarized
outlet. If the plug does not fit fully in the
outlet, reverse the plug. If it still does
not fit, contact a qualified electrician.
DO NOT attempt to defeat this safety
feature.
5. Close supervision is necessary when any
appliance is used by or near children.
6. Turn the fan OFF and unplug the fan from
the outlet when not in use, when moving
the fan from one location to another and
before cleaning.
7. To disconnect the fan, first turn the unit
OFF, grip the plug and pull it from the wall
outlet. Never pull the plug by the cord.
8. Do not operate the fan in the presence of
explosive and/or flammable fumes.
9. Do not place the fan or any parts near
an open flame, cooking or other heating
appliance.
10. Do not operate the fan with a
damaged cord or plug or if the product
malfunctions, is dropped
or damaged in any manner
(see warranty).
11. Avoid contact with moving fan parts.
12. The use of attachments not
recommended by the manufacturer may
be hazardous.
13. Place the fan on a dry level surface.
14. Do not hang or mount fan on a wall
or ceiling.
15. Do not operate if the fan housing is
damaged.
The Honeywell Trademark is used by Kaz USA, Inc. under license from Honeywell International Inc.
Honeywell International Inc. makes no representation or warranties with respect to this product.
1
16. A loose fit between the AC outlet
(receptacle) and plug may cause
overheating and a distortion of the plug.
Contact a qualified electrician to replace
loose or worn outlet.
17. Do not operate any fan with a damaged
cord or plug. Discard any damaged fan,
return the fan to the retailer where the
fan was purchased, or request a return
authorization to return to Kaz USA, Inc. for
examination and/or repair.
FUSED SAFETY PLUG - FOR US ONLY
Thank you for your purchase.
This fan features a fused safety plug which is designed to cut off electric current to the fan if an
electrical fault occurs. Please see below for more information on how to properly use your fan and
replace the safety plug fuse, if needed.
18. Do not run fan cord under carpeting. Do
not cover cord with throw rugs, runners,
or similar coverings. Do not route cord
under furniture or appliances. Arrange
cord away from traffic areas and where it
will not be tripped over.
WARNING: To Reduce The Risk of Fire or
Electric Shock, Do Not Use This Fan With
Any Solid-State Speed Control Device,
other than the one supplied.
USER SERVICING INSTRUCTIONS
• Grasp plug and remove from the receptacle or other outlet device.
Do not unplug by pulling on cord.
• If your fan loses power and you suspect that the fuse on your fan
has blown, you should first remove the spare fuse holder attached
to the cord plug (Fig. 1). Remove the spare fuse from the plastic
spare fuse holder, and set the spare fuse aside (Fig. 2).
• You can gain access to the blown fuse by sliding open the door
found on the side of the plug. Slide the door outward until the
blown fuse is fully visible (Fig. 3).
• Carefully remove the blown fuse and snap the replacement fuse
into place. Risk of fire. Replace fuse only with 2.5 Amp, 125 volt
fuse (provided with product). Fully close the fuse door by sliding
back into place. Discard the blown fuse. The plug should now be
ready for normal use.
• Risk of fire. Do not replace attached plug. Contains a safety device
(fuse) that should not be removed. Discard product if the attached
plug is damaged.
• If you need further information on how or when to replace the
fuse in the safety plug, please contact Kaz Consumer Relations
Department by visiting our website at www.kaz.com or calling
1-800-477-0457.
Fig. 1
Fig. 2
Fig. 3
2
ASSEMBLY INSTRUCTIONS
A. Pedestal Assembly
• Line up the left and right pedestal assembly and firmly snap
together (Fig. 1).
B. Base Assembly
• Align the two portions of the circular base and snap together by
gently pushing the 4 extrusions (Fig. 2, Item A) into the adjacent
circles of the connecting piece (Fig. 2, Item B).
C. Securing the Pedestal to the Base
• Align the 3 screw holes on bottom of pedestal with the 3 holes
in the base such that the power cord holder is at the rear of the
unit . (Fig. 3)
• Secure the base assembly to the pedestal by inserting and
tightening the 3 screws in the 3 holes located on the bottom
of the base (Fig. 4).
D. Securing the Tower Fan to the Pedestal
• Carefully turn the fan on its side and place on a table. Place
the power cord through the center of the pedestal and base
assembly.
• Align the pedestal with the tower fan so that the one locking
screw hole on the pedestal body is aligned with the rear of
the tower fan unit. Firmly hold the base steady and rotate
the pedestal assembly clockwise to lock the tower fan to the
pedestal assembly (Fig. 5).
• Secure the pedestal to the tower fan by inserting and tightening
1 screw in the opening located near the top rear of the pedestal
assembly (Fig. 6).
E. Securing the Cord to the Base
• With the fan still on its side, locate the cord holding bracket on
the bottom of the base.
• Gently pull any slack out of the power cord, place the power
cord securely in the holding bracket and secure the power cord
bracket over the power cord (Fig. 7).
• Return the tower fan to its upright position.
Note: Do not operate the tower fan unless it is in its proper,
upright position.
Fig. 1
Pedestal Assembly
Fig. 2
Extrusions
Base Assembly
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Positioning
Pole
Positioning
Hole
A
B
Fig. 7
3
On/Off
CORD MANAGEMENT
The cord management feature is located on the back side
of the fan.
Fig. 8aFig. 8b
Simply double up the excess cord length, and place the two
pieces of cord in the notch (Fig 8b).
The notch will hold the cord so that the excess length will not
drag on the ground.
ASSEMBLY INSTRUCTIONS
REMOTE CONTROL BATTERY INSTALLATION/
REPLACEMENT INSTRUCTIONS
Fig. 9
A. Remove battery door by sliding downward in direction of
arrow.
B. Insert 2 AAA batteries into the remote following the directional
guides in the recessed slots (Fig. 9). Batteries are included.
C. Replace battery door by sliding upward opposite of arrow
direction until door snaps in place.
NOTE: DO NOT MIX OLD AND NEW BATTERIES. DO NOT MIX ALKALINE, STANDARD
(CARBON-ZINC) OR RECHARGEABLE (NICKEL-CADMIUM) BATTERIES.
SEE RECYCLERS IN YOUR AREA FOR PROPER DISPOSAL OF BATTERIES.
HY-254 SERIES FAN OPERATION
FAN OPERATIONFAN OPERATION
To turn fan on, press the Power button ( )
located on the left side of the control panel.
Model HY-254
®
Speed Control
The fan will automatically start on “Sleep” speed
when initially turned on. To adjust
the speed up or down, press the Fan Speed button (
) repeatedly to increase level.
Oscillation
To activate the Oscillation feature, press the
Oscillation button (
) once.
Press the Oscillation button again to turn the
Oscillation feature off.
Timer
Choose from 1, 2, 4, or 8 hour settings by
performing the following function:
• 1 hour: Press the Timer button (
) once.
• 2 hours: Press the Timer button twice.
• 4 hours: Press the Timer button a third time.
•
8 hours: Press the Timer button a fourth time.
Press the Timer button a fifth time to turn the Timer feature off.
4
HY-254 SERIES REMOTE CONTROL OPERATION
On/Off
Press the Power button (
) once to turn the fan on. Press the
Power button a second time to turn the fan off.
Speed Control
The fan will automatically start on “Sleep” speed when initially
turned on. To adjust the speed up or down, press the Fan Speed button (
) repeatedly to increase level
Oscillation
To activate the Oscillation feature, press the Oscillation button
) once.
(
Press the Oscillation button again to turn the Oscillation
feature off.
Remote Control Storage
When it is not in use, the remote control may be stored in the
recessed area located behind the controls (Fig. 10).
HY-280 SERIES FAN OPERATION
On/Off
To turn fan on, press the Power button (
)
located on the left side of the control panel.
Current room temperature will be displayed
whenever fan is on.
Speed Control
The fan will automatically start on “Sleep” speed
when initially turned on. To adjust
the speed up or down, press the Fan Speed button (
) repeatedly to increase level.
Oscillation
To activate the Oscillation feature, press the
Oscillation button (
) once.
Press the Oscillation button again to turn the
Oscillation feature off.
Fig. 10
Model HY-280
®
Timer
Choose from 1, 2, 4, or 8 hour settings by performing the following function:
• 1 hour: Press the Timer button (
) once.
• 2 hours: Press the Timer button twice.
• 4 hours: Press the Timer button a third time.
• 8 hours: Press the Timer button a fourth time.
Press the Timer button a fifth time to turn the Timer feature off.
5
HY-280 SERIES FAN OPERATION CONTINUED
Temperature
A. Press and hold the Temperature Control
Button to enter temperature mode.
Model HY-280
®
B. Current room temperature is displayed for
3 seconds, then display begins to flash at
1 second intervals. If temperature is not
selected, unit will revert back to “speed
mode” after 10 seconds.
C. Press the temperature button repeatedly
to increase the temperature by one degree
intervals starting from room temperature.
You will have to cycle through 90° to get back
to the 60° point. (This is the minimum.)
For Canada, the temperature cycle range
is 15°C to 30°C.
D. Once the desired temperature is selected, the fan will revert back to room
temperature display.
Note: The fan speed will adjust automatically to achieve the desired temperature. The
fan will stop if the room temperature drops below setpoint and will turn on again if the
room temperature climbs above setpoint.
• If the user hits the “Power” button, this will override all functions and the unit will
shut “OFF”. The temperature setting will be cleared.
• If the Timer button is selected, the temperature will not be affected. The chosen
temperature will remain in effect and the room temperature will continue to be
displayed. Timer will function with or without Temperature Mode.
Note: If user hits the “speed” button this will also override temperature mode. If the
oscillation button is selected, the Temperature Mode will not be affected.
HY-280 SERIES REMOTE CONTROL OPERATION
On/Off
Press the Power button (
) once to turn the fan on. Press the
Power button a second time to turn the fan off.
Speed Control
The fan will automatically start on “Sleep” speed when initially
turned on. To adjust the speed up or down, press the Fan Speed button (
) repeatedly to increase level.
Oscillation
To activate the Oscillation feature, press the Oscillation button
) once.
(
Press the Oscillation button again to turn the Oscillation feature off.
6
HY-280 SERIES REMOTE CONTROL OPERATION CONTINUED
Temperature Mode can be accessed through the remote control.
A. Press the Temperature Mode button (
) once and release.
Fig. 11
Display will begin to flash.
B. Press the “+” and “-” buttons to change the setpoint.
Note: Once the setpoint is selected, the fan speed will adjust
automatically to achieve the desired temperature. The fan will
stop if the room temperature drops below the setpoint and will
restart if the room temperature climbs above the setpoint.
Remote Control Storage
When it is not in use, the remote control may be stored in the
recessed area located behind the controls (Fig. 11).
USER SERVICING INSTRUCTIONS
CLEANING AND STORAGE
• Ensure the fan is turned off and unplugged.
• Use only a soft cloth to gently wipe the outer surfaces of the fan clean.
• To clean between the grills and fan blade area, we recommend using a pipe cleaner,
flexible dust wand, vacuum cleaner or compressed air to gently remove the dust.
• To clean the rear grill use a soft dry cloth.
• DO NOT immerse the fan in water and never allow water to drip into the motor
housing.
• DO NOT use gasoline, paint thinner or other chemicals to clean the fan.
• For storage, you may leave the fan assembled and covered to protect it from dust.
Store the fan in a cool, dry place.
CONSUMER RELATIONS
Mail questions or comments to:
Kaz USA, Inc.
Consumer Relations Dept.
Call us toll-free at: 1-800-477-0457
E-mail: consumerrelations@kaz.com
Or visit our website at: www.kaz.com
250 Turnpike Road
Southborough, MA 01772
Please be sure to specify a model number.
NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE CONTACT CONSUMER RELATIONS FIRST OR SEE YOUR WARRANTY.
DO NOT RETURN
HOUSING YOURSEL
TO THE ORIGINAL PLACE OF PURCHASE. DO NOT ATTEMPT TO OPEN THE MOTOR
F, DOING SO MAY VOID YOUR WARRANTY AND CAUSE DAMAGE TO THE FAN OR PERSONAL
INJURY.
7
1 YEAR LIMITED WARRANTY
You should first read all instructions before
attempting to use this product.
A. This 1 year limited warranty applies to
repair or replacement of product found to be
defective in material or workmanship. This
warranty does not apply to damage resulting
from commercial, abusive, unreasonable use
or supplemental damage. Defects that are
the result of normal wear and tear will not
be considered manufacturing defects under
this warranty. KAZ IS NOT LIABLE FOR
INCIDENTAL OR CONSEQUENTIAL DAMAGES
OF ANY NATURE. ANY IMPLIED WARRANTY
OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE ON THIS PRODUCT IS
LIMITED IN DURATION TO THE DURATION OF
THIS WARRANTY. Some jurisdictions do not
allow the exclusion or limitation of incidental or
consequential damages or limitations on how
long an implied warranty lasts, so the above
limitations or exclusions may not apply to you.
This warranty gives you specific legal rights,
and you also may have other rights which vary
from jurisdiction to jurisdiction. This warranty
applies only to the original purchaser of this
product from the original date of purchase.
B. At its option, Kaz will repair or replace this
product if it is found to be defective in material
or workmanship. Defective product should
be returned to the place of purchase in
accordance with store policy. Thereafter, while
within the warranty period defective product
may be returned to Kaz.
C. This warranty does not cover damage resulting
from any unauthorized attempts to repair
or from any use not in accordance with the
instruction manual.
D. Return defective product to Kaz, Incorporated
with a brief description of the problem. Include
proof of purchase and a $10 US/$15.50 CAN
check or money order for handling, return
packing and shipping charges. Please include
your name, address and a daytime phone
number. You must prepay shipping charges.
Send to:
In U.S.A.:
Kaz USA, Inc.
Attn: Returns Department
4755 Southpoint Drive
Memphis, TN 38118
USA
In Canada:
Kaz Canada, Inc.
Attn: Returns Department
510 Bronte Street South
Milton, ON L9T 2X6
Canada
Please go to www.kaz.com and register your
product under the Customer Care Center and
receive product information updates and new
promotional offers.
8
Loading...
+ 16 hidden pages
You need points to download manuals.
1 point = 1 manual.