The HE420A,B and HE460A,B Steam Power Humidifiers use
a thermal fan interlock control to provide humidification for
the whole house. The steam power humidifier is designed to
work with high efficiency furnaces, heat pumps and set back
thermostats. The humidifiers work with virtually any
Honeywell humidity control, but use the Honeywell Perfect
Climate Comfort Center™ control for optimal performance.
PRODUCT DATA
FEATURES
• Humidifies the air without a call for heat from the
thermostat so relative humidity fluctuates less,
optimizing homeowner comfort.
• Ideal for homes with extensive woodwork, hardwood
floors, antiques, oil paintings, leather furniture,
pianos, and fine collectibles.
• Capable of humidifying a large area.
• Compact size allows easy installation.
• Minimal amount of water needed for energy efficient
operation.
• Low water cut-off switch and built-in overflow
protection are integral safety features.
• Automatic Flushing Timer reduces frequency of
maintenance in a hard water installation.
• Includes easy-to-use humidity control that mounts
on the wall or duct for more installation flexibility.
• Perfect Climate Comfort Center™ control can be
installed to replace both the thermostat and
humidity control for improved aesthetics and
convenience.
Air Conditioning and Refrigeration Institute Tested:
Standard 610
Models:
HE420A TRADELINE® and HE460A TRADELINE®
Steam Power Humidifier package includes mounting
template and hardware, H908A Humidity Control,
HC40 Automatic Flushing Timer with chlorine removal
filter.
HE420B TRADELINE® and HE460B TRADELINE®
Steam Power Humidifier package includes mounting
template and hardware, H1008A Automatic Humidity
Control, HC40 Automatic Flushing Timer with chlorine
removal filter.
Accessories:
C7089H Outdoor Temperature Sensor.
H1008A Automatic Humidity Control with HumidiCalc™
calculates required humidifier capacity for application).
PC8900 Perfect Climate Comfor t Center™ Control.
Table 1. Size Of Area That Can Be Humidified.
HUMIDIFIER
HUMIDIFICATEUR
6 (152)
House
Description
HE420 Area
(Up To)
Air
Changes
Per HourSq. ftSq. m Sq. ftSq. m
HE460 Area
(Up To)
LooseTw o1,4151311,845171
7-5/8 (194)
9 (229)
12-1/2 (318)
M10534A
AverageOne1,9701832,575239
TightOne-half3,0952884,045376
Fig. 1. Dimensions of HE420A,B/HE460A,B in in. (mm).
ORDERING INFORMATION
When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the
TRADELINE® Catalog or price sheets for complete ordering number.
If you have additional questions, need further information, or would like to comment on our products or services, please write or
phone:
1.Your local Home and Building Control Sales Office (check white pages of your phone directory).
2.Home and Building Control Customer Logistics
Honeywell Inc., 1885 Douglas Drive North
Minneapolis, Minnesota 55422-4386 (612) 951-1000
In Canada—Honeywell Limited/Honeywell Limitée, 155 Gordon Baker Road, North York, Ontario M2H 3N7.
International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France,
Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.
68-0192—22
INSTALLATION
M10578A
HUMIDIFIER
HUMIDIFICATEUR
HE420A,B AND HE460A,B STEAM POWER HUMIDIFIERS
IMPORTANT
Read all the installation instructions before installing
the humidifier.
Select Location and Mount
There are three typical ways of mounting the steam
humidifier:
• horizontally under at least a 10 in. (254 mm) wide duct
using the mounting bracket (preferred mounting);
• horizontally under a reinforced duct;
• horizontally under a duct extension using the mounting
bracket.
Decide which mounting is appropriate and follow those
mounting instructions. See Fig. 2 through 4.
Select a location where the humidifier can be plugged in
without an extension cord. The preferred installation location
is on the warm air side of the furnace. If that location is not
possible, mount the humidifier a minimum of 6 ft (1.8m)
upstream from the furnace filter. Depending on the location
selected, additional duct reinforcement may be necessary
because the humidifier weighs 18 lb when filled with water.
HUMIDIFIER
HUMIDIFICATEUR
Fig. 3. Mounting humidifier horizontally under duct.
M10536A
Fig. 2. Mounting humidifier horizontally under duct
using mounting bracket.
HUMIDIFIER
HUMIDIFICATEUR
M10580A
Fig. 4. Mounting humidifier horizontally under duct
extension using mounting bracket.
68-0192—23
HE420A,B AND HE460A,B STEAM POWER HUMIDIFIERS
WARNING
Electrocution, Heavy Equipment and Chemical
Hazard.
Can cause death, blindness, water damage to
home and heater failure.
• Do not cut into any air conditioning or electrical
line.
• Mount the humidifier in a level position to avoid
water damage and heater failure.
• Wear safety glasses when cutting or drilling.
• Reinforce duct as necessary to ensure stability.
CAUTION
Steam Condensation, Fire and Freezing Water
Hazard.
Can cause failure of fan or limit control or result
in water damage to home.
• Do not install the humidifier where the sidewalls
of the return air duct are constructed of wood
(i.e., floor joist).
• Do not install the humidifier where the
temperature is lower than 32°F (0°C) or higher
than 200°F (93°C).
Mount Horizontally Using Mounting Bracket
(Preferred Mounting Method)
IMPORTANT
The duct must be at least 10 in. (254 mm) wide to
use this mounting method.
The duct is the strongest when using the bracket mounting
method because the least amount of duct reinforcement is
required because of the bracket location. However,
reinforcement may still be necessary to help support the
weight of the humidifier and keep it level.
1. Tape the template 1/2 in. (13 mm) from the edge of the
duct and trace around the template. See Fig. 5.
2. Drill a 3/8 in. (10 mm) hole within the center portion of
the template.
3. Use tin snips to cut around the outline of the template.
IMPORTANT
Follow the dotted line carefully.
4. Remove the template and sheet metal.
5. Cut two 8 in. (203 mm) pieces of the S-cleat
(provided).
6. Place the S-cleat pieces on the narrow sides of the
rectangular opening so the opening (slot) protrudes
down and out of the duct.
7. Cut a 10-1/2 in. (267 mm) piece of S-cleat.
8. Place the 10-1/2 in. (267 mm) piece of S-cleat on the
9. Use two 8-32 screws and nuts (provided) to attach the
IMPORTANT
10. Slide the humidifier tabs into the installed S-cleat. Be
11. Using the mounting bracket as a guide, drill three
12. Secure the humidifier to the duct with three of the
1/2 IN. (13 MM)
FROM EDGE
TEMPLATE
M10876
Fig. 5. Position template.
long side of the rectangular opening closest to the
center of the duct so the opening (slot) shows below
the duct.
mounting bracket (L shaped with six holes) to the top/
front surface of the humidifier. The humidifier is now
ready for mounting.
NOTE: Position the humidifier so the upward
sure the back tab engages completely with the S-cleat
and the mounting bracket touches the side of the duct.
7/64 in. (3 mm) holes through the duct.
no. 8 sheet metal screws (provided).
protrusion of the U is on the side toward the
reservoir.
Do not mount the humidifier until the water level is
adjusted. See Set The Water Level section.