Honeywell He365b1004, He365b, He365a, He365a1006, He365 Installation Instruction

HE365A,B Powered Flow-Through Humidifier
READ AND SAVE THESE INSTRUCTIONS
INSTALLATION INSTRUCTIONS
APPLICATION
INSTALLATION
When Installing this Product...
1. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition.
2. Check the ratings given in the instructions and on the product to make sure the product is suitable for your application.
3. Installer must be a trained, experienced service technician.
4. After installation is complete, check out product operation as provided in these instructions.
TEMPLATE
CAUTION
Hazardous Voltage. Improper drilling can cause equipment damage or personal injury.
Do not cut or drill into any air conditioning or electrical accessory.
U
T
E
R
HORIZONTAL
N
R
U
T
E
R
N
RETURN
R
U
T
E
R
Y
O
B
W
LO
N
W
O
D
O
L
F
Fig. 1. Typical humidifier installation locations.
CLIP
N
R
HIGHBOY
Fig. 4. Position securing clips.
CLIP
M12813
7. Position the humidifier housing in the hole (be sure it is level), so the locking tabs are in place on the upper and lower sheet metal edge of the hole.
8. Push in securing clips until completely seated.
9. Drill holes and install the three sheet metal screws at the top of
the humidifier housing. Secure the housing with the three remaining screws.
10. Reinstall the humidifier pad assembly in the humidifier housing.
M12808
IMPORTANT
For proper operation, be sure the mark on the end of the humidifier pad is facing up. Check that the water feed tube is placed in the guide slots of the humidifier housing.
11. Hook the top of the cover to the housing and secure with the thumbscrew located at the bottom of the cover.
TEMPLATE
WIRING
CAUTION
Freezing Water, Flooding or Static Pressure Hazard. Can cause water damage or permanent equipment damage.
Locate the humidifier where the ambient temperature is between 32°F (0°C) and 160°F (71°C) or property damage can occur.
Do not install humidifier where freezing temperatures could occur.
Be sure supply plenum static pressure is no greater than 0.4 in. wc and water pressure is no greater than 125 psi.
IMPORTANT
Mount the humidifier at least 3 in. (76 mm) above the furnace
jacket to allow adequate space for the drain line. Check that there is adequate space above the humidifier to remove and install the humidifier cover. Do not install on a furnace jacket.
1. Determine the best location for the humidifier and draw a level line on the plenum. See Fig. 1 and 2.
IMPORTANT
To assure optimal product performance, be sure the template is level before marking.
2. Tape this piece of paper in position as your template and trace around the template.
3. Remove the template and carefully cut the rectangular opening.
4. Loosen the thumbscrew on the bottom of the humidifier and
remove the cover.
5. Remove the humidifier pad assembly by grasping the top of the tray and pulling the assembly out of the housing. See Fig. 3.
6. Position the securing clips as shown in Fig. 4.
M12812
Fig. 2. HE360 Humidifier location in relation to air conditioning
cooling coils.
FEED TUBE NOZZLE
WATER DISTRIBUTION TRAY
HUMIDIFIER PAD ASSEMBLY
HUMIDIFIER
THUMB SCREW
COVER ASSEMBLY
HOUSING
M14671
Fig. 3. Humidifier components.
WARNING
Voltage Hazard. Moving parts can cause electrical shock and injury.
Disconnect power supply before installation or servicing.
This device contains a moving fan blade; do not operate the
humidifier without the cover securely attached.
All wiring must comply with applicable local codes, ordinances and regulations.
For H808 Humidistat, H8908 or H908 Convertible Humidity Control Wiring Connections:
IMPORTANT
Select models of fan centers include humidifer taps so the
current sensing relay or sail switch is not needed.
If not using a current sensing relay or sail switch, the 120V
humidifier plug must be energized during blower motor cycles for proper operation.
1. Wire the current sensing relay or sail switch.
2. Connect only the two yellow wires to the humidistat (red wire
connections are not used for mechanical humidistats). See the typical wiring diagrams in Fig. 5 through 7.
For additional mounting and wiring information, refer to the humidistat installation instructions.
® U.S. Registered Trademark Copyright © 2000 Honeywell • All Rights Reserved
69-1428
TEMPLATE
TO BLOWER
W8900B
PC8900
1 2 3 4
M12819A
HE360 HUMIDIFIER
OPTIONAL OUTDOOR AIR SENSOR
1
2 3
2
2
3
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
OPTIMAL CONTROL ACHIEVED WHEN USING OUTDOOR AIR SENSOR. RED WIRES ARE NOT USED IN THIS APPLICATION.
YELLOW
YELLOW
RED
RED
120 VAC
1
MOTOR
2
MECHANICAL HUMIDISTAT
1
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
24V WIRING.
2
HUMIDIFIER
YELLOW WIRES
1
120 VAC
IGNITION BOX
M12686
Fig. 5. Typical wiring diagram for humidifier using fan control to
cycle blower motor fan and humidifier simultaneously.
MECHANICAL HUMIDISTAT
2
HUMIDIFIER
120 VAC
1
For H1008 Automatic Humidity Control wiring connections:
IMPORTANT
• Current sensing relay or sail switch is not needed with the Automatic Humidity Control.
• Use 18-22 gauge insulated wire for proper wiring. We recommend stranded - tinned wire.
1. Connect 24 Vac power to the 24 Vac HOT and COM terminals on the H1008A.
2. Connect the humidifier to the two HUM terminals on the H1008A as shown in Fig. 8.
For additional mounting and wiring information, refer to the Humidity Control installation instructions.
For Perfect Climate Comfort Center Control connections:
2. Use 1/4 in. O.D. copper tubing and connect the saddle valve to the inlet side of the solenoid valve.
a. Place the brass compression nut over the copper tubing. b. Slide the brass ferrule over the tubing.
NOTE: Do not over-tighten the compression nut. Moderate
tightness prevents leaking.
c. Insert the tubing into the solenoid valve fitting and support
the valve while tightening the compression nut.
NOTE: Slope hose downward for correct drainage.
3. Connect a 1/2 in. hose to the humidifier drain fitting and run it to a suitable drain.
CHECKOUT
CURRENT SENSING RELAY
BLOWER MOTOR
LO
C
HI
YELLOW WIRES
1
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
2
24V WIRING.
M12684
Fig. 6. Typical wiring diagram of current sensing relay with
humidifier.
MECHANICAL HUMIDISTAT
SAIL SWITCH
2
HUMIDIFIER
YELLOW WIRES
1
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
24V WIRING.
2
120 VAC
1
M12685
Fig. 7. Typical wiring diagram of sail switch with humidifier.
1. Connect only the two yellow wires to the W8900 (red wire
connections are not used). See the typical wiring diagram in Fig. 9.
For additional mounting and wiring information, refer to the Perfect Climate Comfort Center installation instructions.
Plumbing Saddle Valve
Hot or cold water, either hard or softened, can be used in the humidifier.
1. Use the self-piercing saddle valve (included) to tap into the water supply line at an appropriate location.
CAUTION
Chemical Hazard. Can cause personal injury or equipment damage.
Do not use any line connected to an air conditioner.
IMPORTANT
The saddle valve is not designed to regulate water flow; the valve is either open or closed.
To prevent debris from clogging the solenoid in-line filter, be sure to install the saddle valve handle pointing toward the ceiling.
NOTE: Lightly clean the copper tubing ends with fine
sandpaper before making any connections.
1. Open the saddle valve.
NOTE: The furnace blower must be on for the humidifier to
operate.
2. Set the thermostat setpoint 10°F (6°C) above the room
temperature.
3. Set the convertible humidity control to a high humidity setting, or place the H1008A Automatic Humidity Control in the test position.
4. Observe the water running out of the drain line to be sure the humidifier is working correctly.
5. Check for leaks.
6. Reset the thermostat to a comfortable setting or the Automatic
Humidity Control to the desired frost factor setting.
120 VAC
1
HUMIDIFIER
1
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
2
24V WIRING.
2
CONNECTOR
1
BLACK BLACK
SOLENOID
Fig. 8. Typical wiring diagram for humidifier using H1008A Automatic Humidity Control.
DEHUM DEHUM HUM HUM HOT
COM 24VAC
AUTOMATIC HUMIDITY CONTROL
3
HEAT ONLY APPLICATIOIN SHOWN. SIMILAR WIRING REQUIRED IN HEAT AND COOL SYSTEM WITH ONE OR TWO TRANSFORMERS.
OUT OUT
G
CG
CW
W
FROST FACTOR SETPOINT DIAL
ROOM THERMOSTAT
G
FAN RELAY
W
HEAT RELAY
R
3
FURNACE TRANSFORMER
M12820B
L1 (HOT)
L2
Fig. 9. Typical wiring diagram for humidifier using PC8900/W8900.
1
Home and Building Control
Honeywell 1985 Douglas Drive North Golden Valley, MN 55422
69-1428 G.H. 8-00
69-1175 2
Home and Building Control
Honeywell Limited-Honeywell Limitée 35 Dynamic Drive Scarborough, Ontario M1V 429
Printed in U.S.A. on recycled paper containing at least 10% post-consumer paper fibers.