Honeywell He365b1004, He365h8906, He365a1006, He365 Owner's Manual

HE365A,B Powered
Flow-Through Humidifier
with

OWNER’S GUIDE

® U.S. Registered Trademark Copyright © 2003 Honeywell International Inc. All Rights Reserved
69- 1427- 3

American Lung Association® Health House® Program and Honeywell Working Together For Better Air

Did you know that the average person breathes 3400 gallons (12,870 liters) of air each day * and spends 90% of that day inside?**
Indoor air quality products from Honeywell are designed to help make your home more comfortable—from zoning products that allow you to control the temperature in individual areas of the home to humidifiers and comfort control centers that help balance the moisture content of your indoor air.
Honeywell is proud to be a partner of the American Lung Association® Health House® program that provides guidelines for constructing homes with improved air quality and ventilation.
For more information on ways to improve the air inside your home, please visit the Health House website at: www.healthhouse.org
and the American Lung Association website at: ww.lungusa.org
The American Lung Association and its Health House program do not endorse products.
For more information about Honeywell Indoor Air Quality products, visit: www.honeywell.com/yourhome
or call: 1-800-345-6770 x531
*EPA.National Air Quality 1999 Status & Trends.
**Indoor Air Pollution, An Introduction for Health Professionals, EPA, US Government Printing Office #1994­523-217/81322.
IMPORTANT
69-1427-3 2
Please read these instructions and keep them in your records.
HE365A,B POWERED FLOW-THROUGH HUMIDIFIER WITH

OPERATING YOUR HUMIDIFIER

HE365A

Your Enviracaire Elite™ HE365A Humidifier from Honeywell is controlled by the H8908B Convertible Humidity Control. The convertible humidity control is installed either on an interior wall in the living area, or on the return air duct. Choose the humidity control setting using the combination relative humidity/ outdoor temperature setting scale on your humidity control dial. Match the dial setting to the outdoor temperature for optimizing the humidity level while reducing the moisture condensation on your windows. The table below can also be used to adjust the humidity control to the recommended setting.
Humidity Control Régulateur d'humidité
Y
IT
ID
HUM
OR
O
D
OUT
G
TIN
T
E
S
RE
PERATU
M
E
T
15%
-30 C
F
0
-2 %
0
2
C
-25
-10 F
25%
C
0
-2
0 F
30%
-10 C
F
0
+1
%
35
-5 C
F
0
+2
40%
0 C
r
e
v
O
0 F
2
r
e
v
O
M14694
At Outside
Temperature
Recommended Control Setting
At Outside
Temperature
Recommended Control Setting
-20°F (-29°C) 15 +10°F (-12°C) 30
-10°F (-23°C) 20 +20°F (-7°C) 35
0°F (-18°C) 25 Above 20°F (-7°C) 40
NOTE: As the outside temperature drops, the recommended humidity control setting
is lowered to accommodate for effects of dewpoint. These settings should reduce the accumulation of moisture and ice on your windows and in other areas of your home.
Some indoor activities such as cooking, showering and clothes drying can cause excessive levels of humidity and start the accumulation of moisture on your windows.
NOTE: If this condition persists for more than a few hours, set the humidity control to
the lowest setting to turn off the humidifier. If the condition does not improve, ventilate your home to remove the moisture.

HE365B

Your Enviracaire Elite™ HE365B Humidifier is controlled by the Honeywell H1008 Automatic Humidity Control with HumidCalc+™. The automatic humidity control is mounted in the return air duct where it can be exposed to the air stream of the return air.
H1008A
M12817
3 69-1427-3
Loading...
+ 5 hidden pages