FEATURES/BENEFITS
• Antimicrobial coating on pad prevents the surface growth and migration of bacteria, mold, fungus and algae on the humidifier pad.
• Bold new look with blue and white styling.
• Capable of humidifying the largest area—up to 4200 sq ft (390 sq m)—of any Honeywell flow-through humidifier.
• Includes the PerfectFlo™ water distribution tray for optimal efficiency and water usage.
• Narrower footprint than popular compatible model while maintaining a common humidifier pad and comparable humidification performance.
APPLICATION
The Enviacaire Elite HE365A,B Powered Flow-through Humidifiers use the warm air furnace blower to provide humidification for the whole house.
• Interior components designed for quick maintenance and service.
• HE365A Humidifier includes a convertible humidity control that mounts on the wall or duct for more flexibility.
• HE365B Humidifier includes the Automatic Humidity Control with HumidCalc+™ that automatically adjusts humidity level and eliminates moisture build-up.
• Continuous flushing reduces the frequency of maintenance in a hard water installation.
• AIRWATCH™ Indicator can be installed to remind homeowner to change humidifier pad.
• Five-year warranty.
® U.S. Registered Trademark Copyright © 2000 Honeywell • All Rights Reserved
68-0243
HE365A,B POWERED FLOW-THROUGH HUMIDIFIER
SPECIFICATIONS
IMPORTANT
The specifications given in this publication do not include normal manufacturing tolerances. Therefore, this unit may not exactly match the listed specifications. Also, this product is tested and calibrated under closely controlled conditions and some minor differences in performance can be expected if those conditions are changed.
TRADELINE® Models Available:
HE365A: Includes humidifier, antimicrobial humidifier pad,
mounting template, self-piercing saddle valve and H8908B Convertible Humidity Control.
HE365B: Includes humidifier, antimicrobial humidifier pad,
mounting template, self-piercing saddle valve and H1008A Automatic Humidity Control.
Capacity:
At 120°F (49°C) plenum temperature and 0.20 static pressure drop across supply and return: 18 gallons per day (gpd), 68 liters per day (lpd).
Humidified Area:
House Air Changes
Description Per Hour
Loose Two 1,900 175 Average One 2,700 248 Tight One-half 4,200 386
Electrical Ratings: 120 Vac, 60 Hz, 0.7A.
Humidifier Pad Dimensions (height x width x depth):
13 in. x 10 in. x 1-1/2 in. (330 mm x 254 mm x 38 mm).
Plenum Opening Dimensions (height x width):
14-1/16 in. x 13-1/2 in. (357 mm x 343 mm).
Area (Up To)
Sq ft Sq m
Drain Connection:
1/2 in. (13 mm) I.D. plastic hose connected directly to drain fitting on unit.
Dimensions:
Refer to Fig. 1.
10-1/4 (260)
14 (356)
15-1/4
M14815
(387)
Fig. 1. HE365A,B dimensions in in. (mm).
Approvals:
Underwriters Laboratories Inc.: Listing Pending. Canadian Underwriters laboratories Inc.: Listing Pending.
Standards:
Air Conditioning and Refrigeration Institute Tested: Standard 610.
Accessories:
C7089H Outdoor Temperature Sensor. H8908B Convertible Humidity Control. H1008A Automatic Humidity Control. HC26E Humidifier Antimicrobial Pad. PC8900 Control. S688A Sail Switch. Current Sensing Relay part no. 32001754-001.
ORDERING INFORMATION
When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the TRADELINE® Catalog or price sheets for complete ordering number.
If you have additional questions, need further information, or would like to comment on our products or services, please write or phone:
1. Your local Home and Building Control Sales Office (check white pages of your phone directory).
2. Home and Building Control Customer Relations Honeywell, 1985 Douglas Drive North, MN10-1461 Golden Valley, Minnesota 55422-4386 1-800-468-1502
In CanadaHoneywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarbouorgh, Ontario M1V 4Z9. International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.
68-0243
2
INSTALLATION
M12808A
HORIZONTAL
D
O
W
N
FL
O
L
O
W
B
O
Y
R
E
T
U
R
N
R
E
T
U
R
N
RETURN
HIGHBOY
R
E
TU
R
N
M14671
COVER ASSEMBLY
HUMIDIFIER PAD ASSEMBLY
FEED TUBE NOZZLE
WATER DISTRIBUTION TRAY
HUMIDIFIER HOUSING
THUMB SCREW
When Installing this Product...
1. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition.
2. Check the ratings given in the instructions and on the product to make sure the product is suitable for your application.
3. Installer must be a trained, experienced service technician.
4. After installation is complete, check out product operation as provided in these instructions.
CAUTION
Personal Injury or Equipment Hazard. Improper drilling can cause equipment damage or personal injury.
Do not cut or drill into any air conditioning or electrical accessory.
CAUTION
Property or Equipment Hazard. Can cause property or equipment damage.
• Locate the humidifier where the ambient
temperature is between 32°F (0°C) and 160°F (71°C).
• Do not install where freezing temperatures could occur.
• Be sure supply plenum static pressure is no greater than 0.4 in. wc and water pressure is no greater than 125 psi.
Location and Mounting
IMPORTANT
Mount the humidifier at least 3 in. (76 mm) above the furnace jacket to allow adequate space for the drain line. Check that there is adequate space above the humidifier to remove and install the humidifier cover. Do not install on a furnace jacket.
HE365A,B POWERED FLOW-THROUGH HUMIDIFIER
Fig. 2. Typical humidifier installation locations.
M12812A
Fig. 3. HE365 Humidifier location in relation to air
conditioning cooling coils.
1. Determine the best location for the humidifier and draw a level line on the plenum. See Fig. 2 and 3.
IMPORTANT
Be sure the template is level before marking to assure optimal product performance.
2. Tape the template in position and trace around the template.
3. Remove the template and carefully cut the rectangular opening.
4. Loosen the thumbscrew on the bottom of the humidifier and remove the cover.
5. Remove the humidifier pad assembly by grasping the top of the tray and pulling the assembly out of the housing. See Fig. 4.
6. Position the securing clips as shown in Fig. 5. Do not completely seat them.
Fig. 4. Humidifier components.
3
68-0243
HE365A,B POWERED FLOW-THROUGH HUMIDIFIER
CLIP
CLIP
M12813
Fig. 5. Position securing clips.
7. Position the humidifier housing in the hole (be sure it is level), so the locking tabs are in place on the upper and lower sheet metal edges of the hole.
8. Push in the securing clips until completely seated.
9. Drill holes and install the three sheet metal screws at the top of the humidifier housing. Secure the housing with the three remaining screws at the bottom of the housing.
10. Reinstall the humidifier pad assembly in the humidifier housing.
IMPORTANT
For proper operation, be sure the mark on the end of the humidifier pad is facing up. Check that the water feed tube is placed in the guide slots of the humidifier housing.
11. Hook the top of the cover to the housing and secure with the thumbscrew located at the bottom of the cover.
WIRING HUMIDIFIER
WARNING
Serious Personal Injury or Equipment Hazard. Moving parts can cause electrical shock and injury.
• Disconnect power supply before installation or servicing.
• This device contains a moving fan blade; do not operate the humidifier without the cover securely attached.
2. Connect only the two yellow wires to the humidity control (red wire connections are not used for mechanical humidity control). See the typical wiring diagrams in Fig. 6 through 8.
For additional mounting and wiring information, refer to the humidity control installation instructions.
For H1008 Automatic Humidity Control Wiring Connections:
IMPORTANT
Current sensing relay or sail switch is not needed with the Automatic Humidity Control.
1. Connect the two red and two yellow wires to the electronic humidity control as shown in Fig. 9.
For additional mounting and wiring information, refer to the humidity control installation instructions.
TO BLOWER MOTOR
2
MECHANICAL HUMIDISTAT
1
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
24V WIRING.
2
HUMIDIFIER
YELLOW WIRES
Fig. 6. Typical wiring diagram for humidifier using fan
control to cycle blower motor fan and humidifier
simultaneously.
MECHANICAL HUMIDISTAT
2
HUMIDIFIER
1
120 VAC
IGNITION BOX
M12686
120 VAC
1
All wiring must comply with applicable local codes, ordinances and regulations.
For H8908B Convertible Humidity Control Wiring Connections:
IMPORTANT
Select models of fan centers include humidifier taps so the current sensing relay or sail switch is not needed.
• If not using a current sensing relay or sail switch, the 120V humidifier plug must be energized during blower motor cycles for proper operation.
1. Wire the current sensing relay or sail switch.
68-0243
CURRENT SENSING RELAY
BLOWER MOTOR
LO
C
HI
YELLOW WIRES
1
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
2
24V WIRING.
Fig. 7. Typical wiring diagram of current sensing relay
with humidifier.
4
M12684