The Zoning Manager HCM 200D is designed to provide home automation control. HCM 200D includes both, the 433 MHZ and 868 MHZ transceiver. This provides backward compati­bility to all 433 MHz components within the Hometronic family and capabilities to control radiator controllers such as HR 80 and further products based on 868 MHZ technology. Due to the modular design and architecture, the HCM 200D can be configured and upgraded according to individual customer requirements. It covers a wide range of applications in terms of:
Comfort Individual room temperature control for radiators and under floor heating.
Convenience Shutter, lighting control, appliance and cooling control.
Security and safety Presence simulation, alarm messages, and sensor contact detection.
Remote access is possible via phone (internet on request). The HCM 200D user interface is the same as the HCM 200. The programming philosophy combined with the operation keys makes this product easy to program and use.
FEATURES
Usable for upgrading CM Zone applications to expand individual room temperature control for up to 16 zones
433 MHZ and 868 MHZ reliable RF communication utilizing 868 MHZ band with 1% duty cycle limit to minimize communication disturbance
High performance:
- Up to 1600 switching points
- 16 lifestyles with 400 actions
- 32 modules for shutter, lighting and appliance control
- Up to 16 allocatable sensors
- Upgradeable software via download
User friendly interface:
- backlit display (4 lines, 20 characters)
- dial button (turn/press)
- ECO and Auto/Manu button
- dedicated life style buttons
Individual room temperature control for up to 16 different zones (rooms) with radiator and under floor heating control
Heating/Cooling functionality
Full integration of HR80 functionalities:
- Local operation lock disables manual overwrite HR 80 optimization
- Set point limit min.
- Set point limit max.
Window function (set point will be changed if the window is open/closed)
Boiler feedback dependent on the set point and on the valve position (HR80 only)
Analog output for boiler feedback (MCR36/40/200/ZGxx)
Individual shutter and awning control dependent on the time program, brightness and room/outside temperature
Individual lighting control dimming function
Security and safety functions:
- Presence simulation
- Detection of sensor contact (water leakage)
- Alarm messages sending via phone
Appliance control switch ON/OFF electrical devices
Water stop control
EN0H-0482GE51 R1004
HCM 200D
SPECIFICATIONS
Operating voltage 2 V AC/DC Power consumption 4 VA Batteries 3 x size AA, Micro 1.5 V Battery replacement Program retained in EEPROM Dimensions (HxWD) 170 x 127 x 40 mm Display Backlit ( 4 lines, 20 characters
per line)
Operating temperature to 40 °C Shipping and storing
Temperature -20 to +70 °C Humidity 5 to 93 %, non condensing IP class IP30 Safety class 2 Approval CE, countries outside EU
require country specific RF approval
RF communication range max. 30 m in a residential
building environment rage
RF operation band LPD (868.0 – 868.6) MHZ,
1 % duty cycle ISM 433 MHZ (433.150 –
434,700) 10 % duty cycle
Receiver Class 2
APPLICATION EXAMPLES
Application overview for Heating, Convenience and Communication based on 868MHZ and 433MHZ
433MHZ
Telecom Network
Communication
HCI300
Internet
HR50
HCU30
433MHZ
HCW22 HCF22
HCE60
HCM200D
Heating Control
• HCM200D includes transceiver 868MHZ + 433MHZ
• HCM200 D is communicating with HR80 and future 868MHZ devices.
• Backward compatible with all 433MHZ
devices within the 433MHZ Hometronic family.
HRD20
HS20
HA70
HR80
868MHZ
HC60NG
Convenience
433MHZ
HA30 HD30 HS30 HX10
HB05 HB15 HWS40
EN0H-0482GE51 R1004
2
HCM 200D
Heating application for Under Floor Heating and Radiator Control based on 868MHZ and 433MHZ
Zoning Manager
HCM 200D
868MHZ / 433MHZ
HR 50 433MHZ
HR 80 868MHZ
Under floor heating controller HCE 60
Remote set point HCW 22
Remote set point
Remote set point HCU 30 with time program
HCW 23
Room sensor HCF 22
Antenna HRA 1
Optional Boiler feedback with boiler relay and analogue output (TW)
CM Zone mixed applications for Under Floor Heating and Radiator Control based on 868MHZ
Floor xx
Radiator Control
Floor 2
Radiator Control
Floor 1
Under Floor Heating
Optional
HC60NG
CM67z
HR80
HR80
HC60NG
Zone 1
Boiler feedback signal HCM200D
Zone 1 to 16
a
n
o
i
t
c
e
r
i
d
i
B
R
H
n
e
e
w
t
e
B
Zone 2
m
m
o
c
l
d
n
a
0
8
c
i
n
u
C
H
HCM200D
868MHZ
n
o
i
t
a
D
0
0
2
M
l a n g
i s
k c a b d e e
f r e
l
i o B
433MHZ
Mixed application for underfloor heating control and enhanced radiator applications with
D 0 0
zoning manager HCM200D up to
2 M
16 zones.
C H
The underfloor can be controlled
only with the zone 1 of CM67z
because it includes the room sensor and controls HC60NG for Zone1. Zone 2 controls HR80
but alternatively it can be also controlled from HCM200D. The
boiler inter lock signal is generated by the CM67z for the zone1 and for zone 2 zone from each radiator controller HR80. However the boiler demand signal is also generated by the HCM200D depending on the heating request of each installed room (zone). The boiler relay HC60NG is controlled by the CM67z and HCM200D based on heating demand of the individual zones.
Zone 1 can be controlled only with CM67z because PWM control of the HC60NG
3 EN0H-0482GE51 R1004
HCM 200D
Enhancement of existing applications
HCM200D
for Radiator Control based on 868MHZ
Floor xx
Radiator Control
Floor 2
Radiator Control
Floor 1
Radiator Control
optional
HC60NG
CM67z
HR80
HR80
HR80
Boiler feedback signal HCM200D
Zone 16
Zone 3
Zone 2
Zone 1
l a
. .
n g
i s
k c a
b d e e
f r e
l
i o B
868MHZ 433MHZ
Enhancement of existing CM Zone applications with zoning manager HCM200D for radiator control.
D
CM67z will be replaced with
0 0 2
HCM200D. Up to 16 zones can be
M C
controlled individual. The boiler
H
inter lock signal is generated by the HCM200D. Depending on the heating request of each zone the boiler will be controlled via the relay module HC60NG. Up to 4 HCM200D can send their heating demand signal to the HC60NG. However it can be also a mix between HCM200D and CM67z where the boiler demand signal will be sent to one HC60NG. The limitation is max. 4 controller can communicate to one boiler relay.
Radiator control with product mix existing HR50 and HR80 based on 868MHZ and 433MHZ
Floor xx
Radiator Control
Floor 2
Radiator Control
Floor 1
Radiator Control
optional
HC60NG
HR80
HR50
HR50
Boiler feedback signal HCM200D
Zone 16
. .
Zone 3
Zone 2
Zone 1
HCM200D
868MHZ 433MHZ
l a n g
i s
Enhancement of existing
k c
applications for radiator control
a b d
with HR50 and HR80.
D
e
0
e
0
f
The HCM200D can control still
2
r e
M
l
HR50 and the application can be
i
C
o
H
mixed up with HR80.
B
The boiler inter lock signal is generated by the HCM200D. However the HC60NG will be controlled depending on the valve position (HR80 only). The boiler feed back for the HR50 is based on the set points and can control the relay module HS30 or HS20. Recommendation: If HR50 and HR80 is used in one application and boiler feed back is required than it should be a separate heating circuit for the HR50 and HR80. In case only one heating circuit is available for both devices than the boiler feed back should be requested by the HR80 because the boiler is controlled based on the valve position and provides a perfect solution.
EN0H-0482GE51 R1004 4
HCM 200D
5 EN0H-0482GE51 R1004
HCM 200D
Honeywell GmbH 71101 Schönaich Böblinger Straße 17 Telephone (+49) (0) 7031 637-01
The right is reserved to make modifications This company is certificated to
Honeywell Inc. hereby declares that this device complies with the basic requirements and other relevant regulations of guideline 1999/5/EC. The declaration of conformity of the product can be requested from the manufacturer.
Note to non-EU countries: This product may only be used if operation in the 433 MHz and 868 MHz frequency band is permissible.
EN0H-0482GE51 R1004
Loading...