The CM701 thermostat is designed to provide automatic time
and temperature control of heating systems in villas and
apartments.
It can be used as part of a system in conjunction with combiboilers, oil-burners and gas fired boilers, circulation pumps,
thermal actuators, zone valves and electric heat systems
(<5A).
The CM701 is designed with the installer in mind and
includes a moulded back-plate with trunking guides and
wiring breakouts to make installation quick and easy.
The CM701 large LCD display, button layout based on the
same simple programming philosophy used on our acclaimed
CM20 products and the introduction of an ‘OK’ button makes
it easier to install and more user friendly.
The unit is ideal for consumers who want reliable precise
temperature control from a modern looking, simple to
program and easy to use product.
FEATURES
Attractive slim, modern styling makes it ideal for
•
location in any type of home.
• 24 hour heating program.
• Up to 4 daily independent time and temperature level
changes let you set 4 time and temperatures pairs to
suit your lifestyle.
• LCD Backlighting to illuminate the display for easier
viewing in low light conditions.
• Temporary programmed temperature override to
temporarily override the programmed temperature till
the next switch point.
• Room Temperature Enquiry.
• EEPROM memory holds the user program
indefinitely.
• OFF mode has an integral frost protection setting at
minimum 5°C (installer adjustable) so that pipes in
the house will never freeze in winter.
• 24...230V 5A resistive, 2A inductive SPDT relay
provides compatibility with most domestic central
heating systems reducing the need to stock many
different models.
• Battery powered by 2 x AA size (LR6) alkaline cells.
• Minimum battery life of 2 years with low battery
warning indicator.
• Built-in default heating program.
• Automatic Summer / Winter time change adjusts the
time automatically to daylight saving time.
• Scheduled Maintenance Alert Period.
• Surface or wall box mounting options, with trunking
guides and wiring breakouts to simplify installation.
• No installer links or special installer switches on the
back of the unit mean no adjustment is required for
combi-boilers and most domestic central heating
systems.
• User Set-Up Mode allows extra functions to be set at
the discretion of the user:
• AM-PM or 24hr time display.
• Resetting the heating profile to factory default.
• Enable / disable of Auto Summer / Winter time
change.
• Installer Set-Up Mode allows extra functions to be set
at the discretion of the installer to match the
consumers applications and needs:
• Optimisation.
• Pump Exercise.
• Upper / Lower Set point Limit Adjust.
• Temperature offset.
• Minimum ON time.
• Cycle rate.
• Proportional Band Width.
• Diagnostic Mode to assist in faultfinding.
EN0H 8559 UK07 R0 09/06
CONTROLS / DISPLAY LAYOUT
CM701 CHRONOTHERM
PRODUCT LAYOUT:
1. LCD Screen
2. Battery Low Indicator
3. Time Display
4. Burner On Indicator
5. Temperature Display
6. Temperature Change Buttons
7. Information Enquiry Button
8. Operating Mode Buttons
9. Green OK Button
10. Battery Compartment
11. Battery Cover
12. Program Buttons
13. Time Change Buttons
14. Date Button
SPECIFICATIONS
Batteries : 2 x 1.5 V IEC LR6 (AA) Alkaline cells
Battery life : Minimum 2 years
Battery
replacement
Switch type : SPDT (potential free)
Electrical rating : 230 V~, 50...60 Hz, 0.1 A to 5 A resistive
Time display : 24 hour or 12 hour AM/PM format
Time keeping
accuracy
Program : 4 daily time and temperature level
Time setting
resolution
Sensing element : 100K (@ 25 oC ) NTC thermistor
Temperature
setting range
: Program retained in EEPROM
0.1 A to 2 A inductive (0.6 pf)
24 V~, 50...60 Hz, 0.5 A to 5 A resistive
0.5 A to 2 A inductive (0.6 pf)
: Typically better than 10 minutes per year
changes
: Time of day - 1 minute
Program - 10 minute steps
: Program : 5 to 35oC in 0.5 oC steps
Frost : 5
o
C to 21 oC).
(5
o
C or equal to lower limit
Temperature
control accuracy
Room
: ±0.5 K (nominal) @ 20oC, 50% load
3 K Δ/hour
o
: From 0
C to 50 oC
Temperature
display range
Control form : P + I (Proportional + Integral)
Minimum ON
time
: 10% of cycle time (min one minute),
adjustable to 2 to 5 min (see installer set
up)
Cycle rate : Selectable by application (see installer
set up)
Wiring : Terminal block capable of accepting
wires up to 2.5 mm
2
Wire access : Mains wiring – rear right.
Low voltage wiring – rear right.
Dimensions : 133 x 88.5 x 26 mm (w x h x d)
130 x 175 x 26 mm (w x h x d)
(flap open)
Environmental : Operating temperature range 0 to 40oC
c) The unit will display the first parameter of installer
parameter group category 1 (from n.1 to n.19).
d) Press the TEMP
setting. The display will flash indicating that a change has
been made.
e) Press the green OK button to confirm this change and the
display will stop flashing.
f) Press the
+ button to go to the next parameter.
g) Press the program button > to go to category 2 in the
Installer mode (from n.1 to n.5).
h) To exit the installer mode, press the AUTO, MAN or OFF
buttons.
In Installer set-up we can:
❑ Set-up specific applications
❑ Enable special features
i button and the two program
or buttons to change the factory
Installer Set-up Number
(Press + or - to change)
e.g. 1 = Clock Format
CM701 CHRONOTHERM
Abbreviated Set-Up Description
Press TEMP or to change
e.g. Cl = Clock Format
Factory Setting or New Choice
e.g. 12 = AM/PM Format
24 = 24hr Format
Specific Applications Setting What do you need to change?
Heating Gas Boilers
(<30KW)
Oil Boiler 3 4 1. Set Minimum ON Time to 4 minutes.
Thermal Actuator 12 1 Set Cycle/Hour to 12.
Zone valve 6 1 No action required.
Electric heating
(for applications
<5A
Cycle/
Hour
Minimum
ON time
(in minutes)
6 1 No action required
12 1
Note :
a. To change Cycle/Hour, please go to parameter n. 2, category 2
in the installer set-up mode.
b. To change Minimum ON Time, please go to parameter n. 1,
category 2 in the installer set-up mode.
2. Set Cycle/Hour to 3.
1. Set Cycle/Hour to 12.
3 EN0H 8559 UK07 R0 09/06
CM701 CHRONOTHERM
Special Features Description What to do if we wish this
feature
Optimisation (Variable
Start Time)
Adaptive Intelligence
recovery TM
The thermostat will adjust the start time in the
morning/afternoon so the desired temperature is
reached by the start of the program period e.g. Time
7:00, Temp 21
o
C. The thermostat will monitor the
accuracy of the start up and use this information to
modify the calculation for the following day by changing
the ramp rate (initial 3 K/hr) .The system will restrict the
start time to a max of 2 hours.
Note: Optimisation will not work in cooling mode.
Set parameter n.8, category 1 in the
installer set-up mode to 1.
AM-PM/ 24hr Display Change display format (default 24hr). Set parameter n.1, category 1 in the
installer set -up mode to 12.
Pump exercise When enabled the Pump Exercise will switch the relay
on for 1 minute at 12:00 if the relay has not been
Set parameter n.5, category 2 in the
installer set -up mode to 1.
switched on since 12:00 the previous day.
While in Holiday mode the Pump Exercise feature, if
enabled, will operate.
Upper Temperature Limit The normal upper temperature limit of 35 oC can be
reduced down to 21
o
C to save the homeowner energy.
Useful if the homeowner rents to tenants.
Lower Temperature Limit The normal lower temperature limit of 5 oC can be
increased up to 21
o
C to protect the inhabitants from
cold. Useful if the inhabitants include the elderly,
Set parameter n.6, category 1 in the
installer set -up mode to the desired
limit.
Set parameter n.7, category 1 in the
installer set -up mode to the desired
limit.
children or disabled.
Temperature Offset If the thermostat is located in a hot/cold location and
cannot be moved because of wiring then the measured/
displayed temperature can be adjusted by +/- 3
o
C.
Set parameter n.12, category 1 in the
installer set -up mode to the desired
offset value.
Useful if the homeowner wants the reading to match
another appliance temperature display.
Proportional Band Width Can be adjusted up to 3 oC (default is 1.5 oC) to provide
better temperature control (less overshoot).
Useful for:
Set parameter n.13, category 1 in the
installer set -up mode to the desired
value.
a. Well insulated homes with over-sized heating
systems.
b. Air systems with fast response.
Scheduled Maintenance
Alert Period
Can be set to the required number of months between
1-48. After the specified number of months the
Chronotherm will display ‘SERVICE’ prompting user to
Set parameter n.19 in the installer set
-up mode to the desired value.
arrange a maintenance call
EN0H 8559 UK07 R0 09/06 4
CM701 CHRONOTHERM
Parameter Installer Set-
Up Number /
Abbreviation
(Press + or keys to select)
12:tO 0 No offset -3 to +3 -3°C to +3°C adjustment
in 0.1°C steps
13:Pb 1.5 1.5°C Proportional
Band
1.6 to 3.0 1.6°C to 3.0°C
adjustment in 0.1°C
steps
1
1
1
1
1
1
Scheduled
Maintenance Alert
Period
Reset Parameters
to Factory
Defaults
19:SP 0 Scheduled
Maintenance Alert
Period disabled
20:FS 1 All settings held are
the factory defaults.
Changes to 0 when
one of the
0 to 48 0 to 48 months
adjustments in 1 month
steps
0
Settings are as modified
above
1
To restore the factory
profile set to 1
parameter values
are changed
‘Category 2: System Parameters (You must press the ‘>’ program key to enter this section)
Minimum ON Time
1:Ot 1 1 minute minimum
ON time
2 to 5 2 - 2 minutes
3 - 3 minutes
4 - 4 minutes
5 - 5 minutes
Cycle Rate 2:Cr 6 6 cycles per hour
(cph) for gas boilers,
zone valves and fan-
3, 9, 12 3 - 3 cph
9 - 9cph
12 - 12 cph
coil
Pump Exercise 5:PE 0 Pump Exercise
1 Pump Exercise Enabled 2
Disabled
1
1
2
2
EN0H 8559 UK07 R0 09/06 5
DIMENSIONS
CM701 CHRONOTHERM
INSTALLATION
LOCATION
The CM701 thermostat is the control element of the heating
system and, therefore, MUST be located in a position with
good air circulation, at average room temperature and on an
inside wall, 1.5 metres above the floor level. Do not position
the CM701 thermostat near sources of heat (radiators, hot air
vents, TV or lights), near doors or windows, or in direct
sunlight.
MOUNTING
The CM701 thermostat can be mounted directly on the wall
surface or on to an electrical wall box.
WIRING
The CM701 thermostat is designed for fixed wiring only and
must be installed in accordance with the latest l.E.E.
regulations. Ensure the wiring connection to the supply is via
a fuse rated at no more than 5 amps and a Class "A" switch
(having contact separation of at least 3 mm in all poles).
IMPORTANT
1. The installer must be a trained service engineer
2. Disconnect the power supply before beginning
installation
EN0H 8559 UK07 R0 09/06 6
WIRING
CM701 CHRONOTHERM
ORDERING SPECIFICATION
Description Model Logo Literature Availability Spec Sheet
1-day programmable thermostat CMT701A1014 Honeywell English Oct 06 ENOH8559
Honeywell Control Systems Limited http://europe.hbc.honeywell.com
Newhouse Industrial Estate
Motherwell ML1 5SB
United Kingdom
EN0H 8559 UK07 R0 09/06
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.