n
Introduction
1.1 Description
The Honeywell CM507 is a programmable room thermostat designed to control your heating system efficiently. The following instructions explain how to
install, program and use the CM507.
1.2 Features
• 7-day heating program with factory default energy saving schedule
• Time-line display facilitating programming
• Subtle, unobtrusive styling matching variety of room decors
Adjustment
Display
buttons
CM507A
Programmable Room Thermostat
Installation and User Guide
1.
2.2 Wiring
Comfort
temperature
preset
Economy
temperature
preset
Program
button
Mode selection /
program exit
Display
Appears when the
: Comfort temperature indicator
: Economy temperature indicator
Time
Day
Manual mode
Automatic mode
Heating is On
o
NOTE: The installation must be performed by an electrician or a qualified
installer.
Installation
set temperature is
displayed
Low battery indicator
Temperature
Schedule
2.1 Baseplate Installation
Choose a location approximately 1.5 m above the floor and on
an inside wall. Avoid draughty areas (top of staircase, air outlet,
etc.), dead air spots (behind doors), direct sunlight or areas near
concealed pipes or chimneys.
2.3 Installing the Batteries
:
Use Alkaline batteries only!
After the batteries are installed, the thermostat performs a series of tests for
approximately 5 seconds.
Once installed on the wall, the thermostat will display the ambient
temperature. The time and day settings flash to indicate that they must be set
(see section 4.1).
2.4 Completing the Installation
2.
3.
p
Basic Functions
3.1 Displaying the Temperature
The measured temperature is normally displayed. To view the set
temperature, press once on either of the buttons. The set temperature is
displayed for 5 seconds along with the icon.
NOTE: Pressing either of the buttons more than once will change the set
temperature.
CM507A 400-147-024-A 2/6/05 1/2
3.2 Setting the Temperature
Press one of the buttons until the desired temperature is displayed.
3.3 Comfort and Economy Temperatures
The thermostat has 2 preset temperature buttons:
• Comfort temperature
• Economy temperature
To set the thermostat at the comfort temperature or economy temperature, press the corresponding preset button. The corresponding symbol will
be displayed.
The following table shows the use and the factory setting of each preset button.
Button Intended Use Default Setting
Comfort (when the occupant is awake and at home) 21°C
Economy (when the occupant is absent or asleep) 17°C
To modify the comfort or economy temperature:
n Set the desired temperature using the buttons.
o Press and hold the appropriate preset button until the corresponding
symbol is displayed.
3.4 Control Mode
3.4.1 Manual
Use this mode to set the temperature at a fixed value. To use this mode, press
Mode to display and set the desired temperature using the buttons or
the buttons.
3.4.2 Automatic
Use this mode to set the temperature according to the energy-saving sched-
ule (see section 4.2). To place in Automatic mode, press Mode to display .
Temporary Override
If you modify the temperature when the thermostat is in automatic mode, the
new temperature will be used for the next 2 hours. Afterwards the thermostat
will return to the automatic mode settings. The icon flashes during the
override period.
3.5 Battery Indicator
An icon appears when the batteries need replacement. This
icon will flash for 60 days, then the thermostat will cut power
to the heating system. The icon disappears once the
batteries are replaced.
After replacing the batteries, readjust the time and day (see
section 4.1).
q
Programming
4.1 Setting the Time and Day
n Press Clk for 3 seconds. The hour display flashes.
o Set the hour using .
p Press Clk. The minute display flashes.
q Set the minutes using .
r Press Clk. The day display flashes.
s Set the day using .
t Press Exit to exit the programming mode.
4.2 Energy-saving Schedule
When the thermostat is placed in automatic mode, it switches between the
comfort temperature and economy temperature according to the programmed
schedule. You can set a different program for each day of the week. The preprogrammed schedule is as follows:
comfort
: Economy :
Monday to
Friday
Saturday and
Sunday
6:00 to 8:00
18:00 to 22:00
Comfort
:
6:00 to 22:00 22:00 to 6:00
8:00 to 18:00
22:00 to 6:00
Economy :
4.3 Modifying the Schedule
n If not already done, set the comfort and economy temperatures
(see section 3.3)
o Press Pgm. The program for Monday will appear and the first hour
period (0:00 a.m. to 1:00 a.m.) is selected (flashes).
NOTE: Note: If you wish to use the same program every day, press Pgm for 3
seconds to select all the days of the week.
p Press or button to advance to the next or preceding hour period
respectively.
q Select the comfort or economy temperature by pressing on the corre-
sponding button ( or ).
r Repeat steps 3 and 4 for each switch point.
s To modify the program for another day, press Pgm until the day is
selected and repeat steps 3 to 5.
t Press Exit to exit the programming mode.
5.
r
Configuration Menu
n To access the configuration menu, press the and buttons
simultaneously for 3 seconds.
o To go to the next parameter (menu item), briefly press the and
buttons simultaneously.
p To modify a parameter, press or .
q Repeat steps 2 and 3 if necessary.
r Press the and buttons simultaneously for 3 seconds to exit the
configuration menu.
4.
DISPLAY DESCRIPTION DEFAULT SELECTIONS
Time Display 12 h 12 h or 24 h
Pump Protection
Number of cycles per hour
1
When pump protection is On, the thermostat will activate the heating sys-
tem for 15 seconds if it has not been activated for the past 24 hours.
2
The corresponding cycle lengths are: 2=30 min., 3=20 min., 4=15 min.,
5=12 min., 6=10 min. Select the cycle according to the type of heating:
Gas boiler <30k W - 10 minutes
Oil boiler - 20 minutes
1
Off On or Off
4 2, 3, 4, 5 or 6
CM507A 400-147-024-A 2/6/05 2/2