CM31 & CM37
• • Battery powered by 2 AA size (LR6) alkaline cells
ANALOGUE CHRONOTHERMS
PRODUCT SPECIFICATION SHEET
The CM31 and CM37 chronotherms 
are designed to provide automatic time 
and temperature control of heating 
systems in the home.
CM31 is a simple to use battery 
powered analogue clock-thermostat 
with electronic temperature control and 
24 hour programming capability.
CM37 has the same features as CM31 
but with the addition of a 7 day clock 
programme.
Both products meet the requirements 
of CE.
• • Attractive modern styling
• • Easy to use programming controls
• • Quartz crystal clock with 12 hour clock face, hour and
minute hands
• • CM31 has 24 hour programme with 96 programming
tappets (15 minute steps)
• • CM37 has 7 day programme with 168 programming
tappets (1 hour steps)
• • P+I temperature control
• • ±± 0.5°C control differential
• • Two temperature levels (Comfort and Economy)
• • Comfort temperature range 10 to 30°C
• • Economy temperature range 5 to 25°C
• • Choice of operating modes : Automatic / Comfort /
Economy
• • Battery life 1 year (nominal)
• • 24...240 V SPDT potential free contacts for wide
flexibility of application
• • Normally-closed (nc) contact terminal protected by
break-off tab to guide installer in 2 wire applications
• • 8 A resistive, 3 A inductive switch rating
• • Batteries supplied
• • Replaceable clock module
− − 24 hour clock, part number R42009899-001
− − 7 day clock, part number R42009899-002
EN0R 8502 R1

CM31 & CM37 CHRONOTHERMS
Product
Power supply : 2 x 1.5 V IEC LR6 (AA) Alkaline batteries 
Battery life : 12 months minimum 
Switch type : SPDT (potential free) latching relay 
Switch rating : 24...230 V~, 50...60 Hz, 8 A resistive;
Time switch : Quartz crystal clock
Clock accuracy : 1 minute 30 seconds per year
Programme : CM31 has 96 tappets (15 minute
Operating 
modes
Temperature 
setting
CM31 is a 24-hour analogue clock 
thermostat 
CM37 is a 7-day analogue clock 
thermostat
3 A inductive @ 0.6 pf 
100,000 operations
12 hour clock face 
24-hour programme for CM31 
7-day programme for CM37 
Clockwise setting only
clock drift ±1 second /day @ 25°C
intervals) Minimum programme interval 
15 minutes (1 tappet)
: CM37 has 168 tappets (1 hour intervals)
Minimum programme interval 2 hours (2 
tappets)
: Automatic
Manual (Comfort/Economy) 
setting by slider
: Comfort setpoint 10 to 30°C
Economy setpoint 5 to 25°C 
setting by rotary knob
Temperature 
control
Control form : ON/OFF 
Control
differential 
Comfort setpoint
accuracy 
Minimum
ON/OFF period 
Wiring : up to 2 x 0.75 to 2.5 mm2 wiring
Dimensions : 135 x 90 x 29 mm (w x h x d)
Environmental : Operating temperature range 0 to 40°C
Protection class : IP30 
Approvals : Meets the requirements of CE.
P+I electronic control, with fixed cycle 
rate of 6 cycles/hour (nominal)
: ±0.5 °C @ 3 °C /hour, at 20°C, 50%
load, 8 A
: ±1.0°C
: 2 minutes
connections
135 x 178 x 29 mm (w x h x d) (flap 
open)
Shipping and storage temperature range
-20 to 55°C 
Humidity range 0 to 90% rh, noncondensing
Relevant standards EN60730-1 (1995), 
EN55014-1 (1997), EN55014-2 (1996).
T6631B1005 - CM31 with 24 hour clock programme 
T6637B1009 - CM37 with 7 day clock programme
EN0R 8502 R1 2

CM31 & CM37 CHRONOTHERMS
LOCATION
The CM31 or CM37 Chronotherm is the temperature control 
element in the heating system and MUST be located in a 
position with good air circulation at average room 
temperature on an inside wall 1.5 metres above the floor 
level. Do not position the Chronotherm near sources of heat 
(radiators, hot air vents, TV or lights), near doors or windows, 
or in direct sunlight.
MOUNTING
CM31 and CM37 can be mounted directly on the wall surface 
or on an electrical wallbox. Mounting screws are supplied for 
both alternatives.
WIRING
CM31 and CM37 are designed for fixed wiring only and must 
be installed in accordance with latest l.E.E. regulations. 
Ensure the wiring connections to the supply are via a fuse 
rated at 8 amps (max) and a Class "A" switch (having contact 
separation of at least 3 mm in all poles).
CM31/ 
CM37
IMPORTANT
Combi boiler control
1. The installer must be a trained service engineer
2. Disconnect the power supply before beginning 
installation
CM31/ 
CM37
CM31/ 
CM37
COMBI BOILER
3 EN0R 8502 R1

CM31 & CM37 CHRONOTHERMS
Zone valve control (i)
CM31/ 
CM37
Electric Heating Systems
Systems rated above 8 A resistive 
(1.75 kW) should be controlled via a 
contactor.
Systems rated below 8 A can be 
switched directly by the CM31 or CM37 
relay.
It is recommended that a voltage 
dependent resistor rated at 275 V 
r.m.s., 23 joules, 775 V clamping 
voltage (e.g. Philips V275LA2) is 
installed across the contactor coil to 
suppress interference from voltage 
spikes.
Zone valve control (ii)
CM31/ 
CM37
CM31/ 
CM37
1.5kW HEATER
Zone valve control (iii)
CM31/ 
CM37
20 Amp 
contactor
CM31/ 
CM37
4.0 kW HEATER
Honeywell Control Systems Limited http://europe.hbc.honeywell.com 
Newhouse Industrial Estate 
Motherwell ML1 5SB 
United Kingdom