Ethernet Cable Kit for UDC 2500/3200/3500
Document Number: 51-52-33-143
Effective: 2/07
Supersedes: 8/13/04
Summary
This kit lets you connect an Ethernet cable from your UDC controller to a hub or PC.
Contents
1 Ethernet RJ45 Cable, 2 Tie Wraps
Table 1 UDC2500 or UDC3200 procedure
Step Action
1
Figure 1 UDC2500/3200 terminal connections
2
3
If you have:
MDI-compliant hub with straight-through cable or
PC with crossover cable
then make these connections:
UDC Terminal
Position 14 Shield Black/Bare Shield Shield
Position 15 RX- Orange 6 TXPosition 16 RX+ White/Orange 3 TX+
Position 17 TX- Brown 2 RXPosition 18 TX+ White/Brown 1 RX+
If you have PC with straight-through cable then make these connections:
UDC Terminal
Position 14 Shield Black/Bare Shield Shield
Position 15 RX- Brown 2 TXPosition 16 RX+ White/Brown 1 TX+
Position 17 TX- Orange 6 RXPosition 18 TX+ White/Orange 3 RX+
Secure cable to controller by attaching tie wraps through the holes in the controller flange.
UDC Signal Name Wire Color RJ45 Socket Pin # Hub/PC Signal Name
UDC Signal Name Wire Color RJ45 Socket Pin # PC Signal Name
Page 1 of 2
Table 2 UDC3500 procedure
Step Action
1
10
10
10
11
11
11
L1
L1
L1
12
12
12
L2/N
L2/N
L2/N
13
13
13
4
4
4
14
14
14
5
5
5
15
15
15
6
6
6
16
16
16
7
7
7
17
17
17
8
8
8
9
9
18
18
18
Tie Wraps (2)
Tie Wraps (2)
Figure 2 UDC3500 terminal connections
If you have:
MDI-compliant hub with straight-through cable or
PC with crossover cable
then make these connections:
19
19
19
20
20
20
21
21
21
22
22
22
23
23
23
24
24
24
25
25
25
26
26
26
27
27
27
28
28
29
29
30
30
31
31
32
32
33
33
34
34
35
35
36
36
Ethernet Adaptor Kit
Ethernet Adaptor Kit
24
24
27
27
UDC Terminal
Position 4 Shield Black/Bare Shield Shield
Position 24 RX- Orange 6 TXPosition 25 RX+ White/Orange 3 TX+
Position 26 TX- Brown 2 RXPosition 27 TX+ White/Brown 1 RX+
2
3
If you have PC with straight-through cable then make these connections:
UDC Terminal
Position 4 Shield Black/Bare Shield Shield
Position 24 RX- Brown 2 TXPosition 25 RX+ White/Brown 1 TX+
Position 26 TX- Orange 6 RXPosition 27 TX+ White/Orange 3 RX+
Secure cable to controller by attaching tie wraps through the holes in the controller flange.
Warranty/Remedy
Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship.
Contact your local sales office for warranty information. If warranted goods are returned to Honeywell
during the period of coverage, Honeywell will repair or replace without charge those items it finds defective.
The foregoing is Buyer's sole remedy and is in lieu of all other warranties, expressed or implied,
including those of merchantability and fitness for a particular purpose. Specifications may change
without notice. The information we supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
While we provide application assistance personally, through our literature and the Honeywell web site, it is
up to the customer to determine the suitability of the product in the application
UDC Signal Name Wire Color RJ45 Socket Pin # Hub/PC Signal Name
UDC Signal Name Wire Color RJ45 Socket Pin # PC Signal Name
Honeywell Process Solutions
Industrial Measurement and Control
512 Virginia Drive
Fort Washington, PA 19034 www.honeywell.com\imc