CX Series 
ISSUE 4  PK 88136
REPLACEMENT LEVERS 
To order replacement levers, order the part 
number which is metal stamped on either the lever 
or the hub. Only nonsparking levers can be used 
to retain the explosion-proof properties. 
MOUNTING ADAPTER —15PA148-CX 
Available for adapting CX to existing 2 hole 
mount. 
22,9
0.9
21,8
0.85 
80
3.15
8,4
0.33
(2)
5/16 -18 UNC (4)
Centerline of CX
Shaft
80
3.15
12,2
0.48
104,4
4.11
ANALOG POSITION-SENSING UNITS 
1. Resistive Output 
Specifications: 
500 ohms ±10% in center (free position) 
975 ohms max. at 105° rotation clockwise (CW) 
25 ohms min. at 105° rotation CCW 
2 watts power at 70°C/150°F at full scale 
Wiring Diagram 
2. Current Output (4 to 20 mA) 
The signal from the position-sensing unit is 
converted to a two-wire 4 to 20 mA current 
output. 
Specifications: 
Voltage compliance range: 12.5 to 40 VDC 
Maximum load resistance: 
mA 20
12.5SupplyV 
maxR
L
−
=
Current signal output: 4-20mA 
Span: Adjustable from 15° to 90° of angular 
rotation 
Null: 4 mA position may be set at any angular 
position 
Typical Wiring Connections: 
ROTARY ACTUATIO N 
Catalog Listing Prefix 
(*listing indicates 
replacement parts) 
11CX, 21CX, 61CX, 
71CX, 81CX, 281CX, 
91CX* 
12CX, 22CX, 62CX, 
72CX, 82CX, 282CX, 
92CX* 
14CX, 24CX, 64CX, 
74CX, 84CX, 284CX, 
94CX* 
16CX, 26CX, 66CX, 
76CX, 86CX, 286CX, 
96CX* 
1172CX, 2172CX, 
9172CX* 
Pretravel, max. 15° 15° 30° 30° 15° 
Differential Travel, 
max. 
5° 10° 25° 20° 5° 
Overtravel, min. 90° 90° 75° 75° 90° 
Circuitry Single-Pole Double-
Throw 
Single-Pole DoubleThrow 
Double-Pole DoubleThrow 
Single-Pole DoubleThrow 
(Gold Contact) SinglePole Double-Throw 
Electrical Ratings 
UL/CSA Rating: L96 
15 A, 120, 240, or 480 
Vac. 
⅛ Hp, 120 Vac; ¼ Hp, 
240 Vac 
0.5 A, 125 Vdc, 0.25 A, 
250 Vdc. 
UL/CSA Rating: L23 
20 A, 120, 240, or 480 
Vac. 
1 Hp, 120 Vac; 2 Hp, 240 
Vac 
0.5 A, 125 Vdc, 0.25 A, 
250 Vdc. 
UL/CSA Rating: L59 
10 A, 120 or 240 Vac. 
0.3 A, 125 Vdc, 0.15 A, 
250 Vdc. 
UL/CSA Rating: L22 
1 A, 125 Vac. 
UL/CSA Rating: L22 
1 A, 125 Vac 
PLUNGER ACTUATION 
Catalog Listing Prefix 
(*listing indicates 
replacement parts) 
31CX, , 41CX, 
101CX* 
32CX, 42CX, 102CX*    36CX, 46CX, 106CX*  3172CX 
Circuitry Single-Pole Double-
Throw 
Single-Pole DoubleThrow 
  Single-Pole Double-
Throw 
(Gold Contact) SinglePole Double-Throw 
Electrical Ratings 
UL/CSA Rating: L96 
15 A, 120, 240, or 480 
Vac. 
⅛ Hp, 120 Vac; ¼ Hp, 
240 Vac 
0.5 A, 125 Vdc, 0.25 A, 
250 Vdc. 
UL/CSA Rating: L23 
20 A, 120, 240, or 480 
Vac. 
1 Hp, 120 Vac; 2 Hp, 240 
Vac 
0.5 A, 125 Vdc, 0.25 A, 
250 Vdc. 
UL/CSA Rating: L22 
1 A, 125 Vac. 
UL/CSA Rating: L22 
1 A, 125 Vac 
Pretravel, max.  2,5 mm [0.10 in] 
Differential Travel, 
max. 
1 mm [0.04 in]    2 mm [0.08 in]  1 mm [0.04 in] 
Overtravel, min.  4,75 mm [0.19 in] 
 Honeywell • Sensing and Control  3