Honestech MP08, MN09CHES, MN09CESWW, MN09CHESBB, MN09CHESWW User Manual

EN
Portable Air Conditioner User Manual
Portable Air Conditioner
Read and save these instructions before use
User Manual
FR
Read and save these instructions before use
Climatiseur portatif Mode d’emploi
Lire ces consignes avant l’utilisation de l’appareil et les conserver
ES
Aire Acondicionado Portátil Manual Del Propietario
Lea y guarde estas instrucciones antes de usar la unidad
Customer Support: Assistance Au Client: Servicio de atencion a clientes: USA/ EE.UU: 1-800-474-2147 CANADA/ CANADÁ#: 1-888-209-0999
#Canada Customer Support service available for models sold in Canada only.
Email: info@jmatek.com
Email: usinfo@jmatek.com
Web: www.jmatek.com
Web: www.jmatek.com
Model :
MP08 Series: MP08CES, MP08CESBB, MP08CESWW
THANK YOU
Congratulations on your purchase of this versatile Honeywell Portable Air Conditioner.
USER TIPS
Honeywell Portable Air Conditioners are ideal for spot cooling. The compressor, condenser and evaporator are housed in a compact unit. The air is filtered, dehumidified and cooled while a flexible air outlet hose sends heat outside. The air conditioner includes a window venting kit. No permanent installation is needed. The unit is easy to move from room to room and offers a truly flexible air conditioning solution.
Auto Evaporation System - The unit automatically evaporates the condensate through the air outlet hose. There is no need to empty the drainage tank except in very humid conditions. Read and follow the instructions carefully.
USER TIPS
To ensure optimal efficiency of the product, keep doors and windows closed when it is used as an air conditioner or dehumidifier. If the product is being used with the fan function only, an open window could improve air circulation.
Cooling and Dehumidifying Operation Fan Operation
Important:
Before installing the unit, place it UPRIGHT for 1 hour before use to allow the refrigerant to stabilize. Manually adjust the air vent located at the top of the unit to adjust the direction of air flow.
Follow installation instructions to set up the unit.
Plug the unit into a properly grounded circuit. DO NOT plug into an extension cord.
EN 1
SAFETY
READ AND SAVE THESE INSTRUCTIONS
Improper handling can cause serious damage to the appliance.
WARNING:
DO NOT operate the unit with a damaged plug or loose wall outlet. If the power cord is damaged, it
must be replaced by the manufacturer or an authorized service agent. DO NOT cover the air intake and exhaust when in use.
This appliance is not intended for use by children. Children should be supervised and should not play
on or around the appliance. DO NOT place objects on or sit on the unit.
Always turn off and unplug the unit when cleaning or servicing.
If service is needed contact an authorized service agent.
Unplug the unit when stored or not in use.
DO NOT run the power cord under carpeting and rugs.
Use caution to prevent tripping on cord.
DO NOT use in areas where gasoline, paint or other flammable goods are stored.
Basic safety precautions should always be followed when using electrical appliances.
This appliance has been manufactured for use in domestic environments and should not be used for
other purposes. Only use the installation kit provided to install this unit. DO NOT attempt to extend the exhaust hose or
install this unit using other methods other than that provided in this manual. Improper installation could void any existing warranties. DO NOT use an extension cord with this unit.
PARTS DESCRIPTION
1
2
4
1) Control Panel (Incl. Signal Receptor)
2) Air Outlet
3) Handle
4) Casters
6
3
7
9
10
5) Air Filter
6) Back Grill
7) Exhaust Hose Connector
8) Power Supply Cord
9) Remote Control
EN 2
5
11
8
10) Lower Drain Plug with Plastic Cap (Air Conditioning Mode)
11) Upper Drain Plug (De-humidifier Mode)
INSTALLATION
It is important that the installation instructions below are followed for successful installation of this portable air conditioner. Please call Customer Support if you have any difficulties or queries regarding these installation procedures.
Installation
1.
2.
3.
4.
5.
Kit:
Window Bracket Kit.............................
Window Bracket Panel Adapter...........
Plastic Pin............................................
Hose Connector..................................
Plastic Hose........................................
1 Set 1 Piece 2 Pieces 1 Piece 1 Piece
1
2
x 1
3
x 2 x 1
5
Installation Steps:
1. Install the plastic hose with window bracket adapter and hose connector on both sides. Ensure proper fit on both ends.
2. Adjust the window bracket as per width or height of your window and insert the plastic pins to fix at the desired position. There is a hole
Connect the plastic hose to the hose
3. Connect the plastic hose to the hose connector on back of the unit. Slide-in the
connector on back of the unit. hose from right to left until it is locked in place.
is locked in place.
Push-in until it
where the Plastic Hose will be inserted later. Make sure this hole is not blocked.
Plastic Pin
4
x 1x 1
Hole for Plastic Hose20" to 47" (50.5cm to 119cm)
Note:
After setting the window bracket to the size of your window, please remove it from the window and follow the instructions below.
4. Connect the window bracket to the opposite end of the plastic hose. Ensure that all connections are tight and installed properly.
EN 3
Plastic Hose: Dia. 5" (12.7cm) Length: 12" to 47" (30cm~120cm)
5. Connect the window bracket to the window.
6. The Portable Air Conditioner is now ready to use.
INSTALLATION (CONTINUED)
IMPORTANT:
The length of the exhaust hose is determined by the product specifications. Do not replace or lengthen it as this could cause the unit to malfunction.
50 cm / 20”
MIN. 36 cm / 14”
MAX. 102 cm / 40”
RECOMMENDEDNOT RECOMMENDED
WARNING: Any warranties included with this product will be voided if an extra extension hose is added
to the originally provided installation kit or if the installation is performed differently than the manufactur­er's instructions, without proper consultation. Please contact Customer Support for help with installation procedures if needed.
The supplied exhaust hose has a diameter of 5 inches (12.7cm) and can be extended from 12 inches to 47 inches (30cm to 120cm).
Do not bend (to the extent shown below) the exhaust hose. A bent hose will block exhaust air and cause the unit to malfunction or shut-off.
Make sure the back of the unit is at least 50 cm / 20 inches away from the wall. Do not place the unit in front of curtains or drapes as this could obstruct the airflow.
USE & OPERATION
TOUCH SCREEN CONTROL PANEL
CONTROL PANEL
(5) (1) (4) (6) (7) (2) (3) (3)
(1) Timer Control (4) Mode Control (7) Timer Light
POWER CONTROL
The Power Control turns the unit on and off. When the unit is plugged in, this button lights up indicating it is in a Standby Mode ready to be switched on anytime.
Cooling Mode
The unit works as an air conditioner. Adjust fan speed and air temperature to suit your desired comfort level. Temperature setting range is 16°C- 32°C (61°F- 89°F).
(2) Fan Speed Control (5) Power Control / Standby Mode
MODE CONTROL
3 settings: Cool, Dehumidify, Fan. A light will indicate which setting is currently being used.
EN 4
(3) Timer / Temperature Set Controls (6) Warning Light (when flashing)
USE & OPERATION (CONTINUED)
FUNCTION BUTTONS (CONTINUED)
••Dehumidifying Mode
Air is dehumidified as it passes through the unit, without being in full cooling mode. If room tempera­ture is higher than 25°C (77°F) fan speed can be adjusted; otherwise fan speed is preset to LOW. Note: If the unit will be used mainly as a dehumidifier, do not connect the exhaust hose and let the warm air return in the room. Continuous drainage is then necessary and more efficient (refer to Continuous Draining). Fan Mode For air circulation without air conditioner cooling.
FAN SPEED CONTROL
3 settings: High, Medium and Low.
2 settings: High and Low.
TIMER CONTROL
While the unit is turned on, press the timer button then press the or to select the number of hours you would like the unit to continue to run. The unit will turn off automatically.
AUTO TURN OFF:
While unit is running, press the press the or button to select the number of hours you want the unit to run in air conditioning mode.
AUTO TURN ON:
When unit is in a standby mode (plugged in with power light on), then press the or button to select the number of hours until you want the unit to automatically start running.
TEMPERATURE / TIMER SET CONTROLS
Used for adjusting the timer and thermostat.
The default display is room temperature.
In cooling mode, when or button is pressed, the set temperature is displayed and may be
adjusted. After 10 seconds the display will revert back to room temperature. Temperature is only adjustable in cool mode. The time is adjustable between 1~24 hours. Note: By pressing both / set buttons at the same time, the display will toggle between Celsius and Fahrenheit.
WARNING LIGHT
Condensed water may accumulate in the unit. If the internal tank becomes full, the Power Control light will flash and the unit will not operate until the unit has been drained (refer Water Condensation
illuminate Drainage).
After switching the air conditioner off, you must wait 3 minutes before switching it back on again.
Warning Light will
EN 5
USE & OPERATION (CONTINUED)
REMOTE CONTROL
The functions work the same as the portable air conditioner's Touch Screen Control Panel.
The functions work the same as the portable air conditioner's Control Panel. All key functions can be accessed from the remote control.
All key functions can be accessed from the remote control.
Power Control
ON / OFF
Fan Speed Control
• HIGH • MEDIUM • LOW
Timer Control
In running mode: Auto switch off In stand-by mode: Auto switch on Press or button to adjust the time setting for 1 hour intervals.
Note:
Battery Installation: Remove the cover on the back of the remote control and insert two AAA batteries with + and - pointing in the proper direction according to the polarity markings.
Temperature / Timer Set
Used for adjusting the timer and temperature.
When or key is pressed in cool mode, the
set temperature is displayed and may be adjusted. After 10 seconds the display will revert back to room temperature. Timer setting is available from 1-24 hours by
pressing the key or
Mode Control
Press this button to change the operation mode in the order of:
Cool Dehumidify
Fan
Caution:
Use only two AAA or IEC R03 1.5V batteries.
Remove the batteries if the remote control is not in use for a month or longer.
All batteries should be replaced at the same time, do not mix with old batteries.
Properly dispose of used batteries.
This device complies with part 15 of the FCC Rules. Operation is subject to following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment dose cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment info an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/ TV technician for help.
Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate
the equipment.
EN 6
CLEANING & MAINTENANCE
Appliance Maintenance:
1.
Turn off the appliance before disconnecting the power supply.
2.
Always clean the appliance with a soft dry cloth.
Air Filter Maintenance:
The air filter should be cleaned every two weeks. Clean it as follows:
1.2.Turn off the appliance and remove the air filter .
Rinse it in lukewarm water. After cleaning, dry in a shaded and cool place, then reinstall.
End of Season Storage & Maintenance:
If the appliance will not be used for a long time:
1.
Be sure to drain the left-over water condensation. Remove the lower drain plug and use a shallow pan to collect the water (make sure to replace the drain plug when finished).
2.
To dry excess moisture, run the unit in Fan only mode for 30 minutes before storing.
3.
Turn off and unplug the air conditioner from the power supply.
4.
Remove the air filter and clean with water. Dry the air filter and then reinstall onto the unit.
5.
Disconnecting the Window Installation Kit:
Remove the Plastic Hose from the unit by pressing the release button located on the right side of
Remove the Plastic Hose from the unit by pulling away from the unit at the same time.
the Hose and then sliding the Hose to the right side.
Remove the Window Bracket, Window Bracket Panel Adapter and Hose Connector.
Remove the Window Bracket, Window Bracket Panel Adapter and Hose Connector. It is recommended to store the Window Kit parts in a bag together with the Remote Control and
It is recommended to store the Window Kit parts in a bag together with the Remote Control and placing them together with the air conditioner unit. placing them together with the air conditioner unit.
If needed, you can clean the Window Kit with a damp cloth and water before storing. Make sure all
If needed, you can clean the Window Kit with a damp cloth and water before storing. Make sure all parts of the Window Kit are dry before storage. parts of the Window Kit are dry before storage.
Air filter
6.
Cover the air conditioner with a cloth/ plastic bag before storage, to protect from dust and scratches collecting on the surface of the unit. It is recommended to coil the power cord and store it away from the floor to ensure the cord is
7.
protected from bents and creases. Store the air conditioner in a cool, dry place, away from direct sunlight.
8.
EN 7
WATER CONDENSATION DRAINAGE
WATER CONDENSATION DRAINAGE
When there is excess water condensation inside the unit, the air conditioner stops running and shows a warning light (the Power Control button flashes with a red light). This warning light indicates that the water condensation needs to be drained using the following procedures:
Manual Draining for AC & Dehumidifier Mode
Water may need to be drained in high humidity areas.
1.
Unplug the unit from power source.
2.
Place a shallow pan under the lower drain plug. See diagram. Remove both the plastic cap and lower drain plug.
3.
Water will drain out and collect in the shallow pan.
4.
After the water is drained, replace the lower drain plug
5.
firmly. You can now turn on the unit.
6.
Continuous Draining for Dehumidifier Mode
While using the unit in dehumidifier mode, continuous drainage is recommended.
1.
Unplug the unit from the power source.
2.
Remove the upper drain plug. While doing this operation some residual water may spill so please have a pan to collect the water. Connect the drain connector to a ¾” hose or standard
3.
garden hose (not included). See diagram. The water can be continuously drained through the
4.
hose into a floor drain or sink. You can now turn on the unit.
5.
Shallow Pan (Not included)
Upper Drain Plug
Plastic Cap & Lower Drain Plug
Water Drain Pipe
EN 8
TROUBLESHOOTING GUIDE
The following troubleshooting guide addresses the most common problems. If problems persist, call customer service. Unplug and disconnect the appliance from the power source before attempting to troubleshoot.
PROBLEM POSSIBLE CAUSE SOLUTION
The air conditioning unit does not start
Runs a short while only
Runs but not cooling A door or window is open.
Will not run and Power button is blinking (water full indicator)
No electricity.
Batteries in the remote control need
to be replaced. The power cord is not properly
plugged in. The safety LCDI plug has tripped
(USA / Canada / Mexico only).
The thermostat temperature setting
is too close to room temperature. Air outlet is blocked.
There are tight bends in the air
exhaust hose.
The air filter is dirty.
The exhaust hose is detached.
Temperature setting is too high.
Air outlet or intake is blocked.
Excess water condensation inside
Drain the water (refer to Water the tank.
Check for power.
Change remote control batteries.
Remove and reconnect the
power cord. Reset the safety LCDI plug, if
problem persists contact our customer support (USA / Canada / Mexico only).
Lower the set temperature.
Make sure the exhaust hose is
properly connected. Connect exhaust hose as per
instructions on page 4.
Make sure the window or door
is closed. Clean the air filter.
Reinstall exhaust hose properly
(refer to Installation section). Reduce temperature setting on
control panel. Remove blockage.
Condensation Drainage).
EN 9
Loading...
+ 22 hidden pages