Lire ces consignes avant l’utilisation de l’appareil et les conserver
ES
Aire Acondicionado Portátil
Manual Del Propietario
Lea y guarde estas instrucciones antes de usar la unidad
Customer Support:
Assistance Au Client:
Servicio de atencion a clientes:
USA/ EE.UU: 1-800-474-2147
CANADA/ CANADÁ#: 1-888-209-0999
#Canada Customer Support service
available for models sold in Canada only.
Email: info@jmatek.com
Email: usinfo@jmatek.com
Web: www.jmatek.com
Web: www.jmatek.com
Model :
MP08 Series: MP08CES, MP08CESBB, MP08CESWW
THANK YOU
Congratulations on your purchase of this versatile Honeywell Portable Air Conditioner.
USER TIPS
Honeywell Portable Air Conditioners are ideal for spot cooling. The compressor, condenser and
evaporator are housed in a compact unit. The air is filtered, dehumidified and cooled while a flexible air
outlet hose sends heat outside. The air conditioner includes a window venting kit.
No permanent installation is needed. The unit is easy to move from room to room and offers a truly
flexible air conditioning solution.
Auto Evaporation System - The unit automatically evaporates the condensate through the air
outlet hose. There is no need to empty the drainage tank except in very humid conditions.
Read and follow the instructions carefully.
USER TIPS
To ensure optimal efficiency of the product, keep doors and windows closed when it is used as an air
conditioner or dehumidifier. If the product is being used with the fan function only, an open window could
improve air circulation.
Cooling and Dehumidifying OperationFan Operation
Important:
Before installing the unit, place it UPRIGHT for 1 hour before use to allow the refrigerant to stabilize.
Manually adjust the air vent located at the top of the unit to adjust the direction of air flow.
Follow installation instructions to set up the unit.
•
Plug the unit into a properly grounded circuit. DO NOT plug into an extension cord.
•
EN1
SAFETY
READ AND SAVE THESE INSTRUCTIONS
Improper handling can cause serious damage to the appliance.
WARNING:
DO NOT operate the unit with a damaged plug or loose wall outlet. If the power cord is damaged, it
•
must be replaced by the manufacturer or an authorized service agent.
DO NOT cover the air intake and exhaust when in use.
•
This appliance is not intended for use by children. Children should be supervised and should not play
•
on or around the appliance.
DO NOT place objects on or sit on the unit.
•
Always turn off and unplug the unit when cleaning or servicing.
•
If service is needed contact an authorized service agent.
•
Unplug the unit when stored or not in use.
•
DO NOT run the power cord under carpeting and rugs.
•
Use caution to prevent tripping on cord.
•
DO NOT use in areas where gasoline, paint or other flammable goods are stored.
•
Basic safety precautions should always be followed when using electrical appliances.
•
This appliance has been manufactured for use in domestic environments and should not be used for
•
other purposes.
Only use the installation kit provided to install this unit. DO NOT attempt to extend the exhaust hose or
•
install this unit using other methods other than that provided in this manual. Improper installation could
void any existing warranties.
DO NOT use an extension cord with this unit.
•
PARTS DESCRIPTION
1
2
4
1) Control Panel
(Incl. Signal Receptor)
2) Air Outlet
3) Handle
4) Casters
6
3
7
9
10
5) Air Filter
6) Back Grill
7) Exhaust Hose Connector
8) Power Supply Cord
9) Remote Control
EN2
5
11
8
10) Lower Drain Plug with
Plastic Cap
(Air Conditioning Mode)
11) Upper Drain Plug
(De-humidifier Mode)
INSTALLATION
It is important that the installation instructions below are followed for successful installation of this
portable air conditioner. Please call Customer Support if you have any difficulties or queries regarding
these installation procedures.
1. Install the plastic hose with window bracket adapter and hose connector on both sides.
Ensure proper fit on both ends.
2. Adjust the window bracket as per width or
height of your window and insert the plastic pins
to fix at the desired position. There is a hole
Connect the plastic hose to the hose
3. Connect the plastic hose to the hose
connector on back of the unit. Slide-in the
connector on back of the unit.
hose from right to left until it is locked in place.
is locked in place.
Push-in until it
where the Plastic Hose will be inserted later.
Make sure this hole is not blocked.
Plastic Pin
4
x 1x 1
Hole for Plastic Hose20" to 47" (50.5cm to 119cm)
Note:
After setting the window bracket to the size of your
window, please remove it from the window and
follow the instructions below.
4. Connect the window bracket to the opposite
end of the plastic hose. Ensure that all
connections are tight and installed properly.
EN3
Plastic Hose:
Dia. 5" (12.7cm)
Length: 12" to 47" (30cm~120cm)
5. Connect the window bracket to the window.
6. The Portable Air Conditioner is now ready to use.
INSTALLATION (CONTINUED)
IMPORTANT:
• The length of the exhaust hose is determined by the product specifications. Do not replace or
lengthen it as this could cause the unit to malfunction.
50 cm / 20”
MIN. 36 cm / 14”
MAX. 102 cm / 40”
RECOMMENDEDNOT RECOMMENDED
WARNING: Any warranties included with this product will be voided if an extra extension hose is added
to the originally provided installation kit or if the installation is performed differently than the manufacturer's instructions, without proper consultation. Please contact Customer Support for help with installation
procedures if needed.
•
The supplied exhaust hose has a diameter of 5 inches (12.7cm) and can be extended from 12 inches
to 47 inches (30cm to 120cm).
•
Do not bend (to the extent shown below) the exhaust hose. A bent hose will block exhaust air and
cause the unit to malfunction or shut-off.
•
Make sure the back of the unit is at least 50 cm / 20 inches away from the wall. Do not place the unit
in front of curtains or drapes as this could obstruct the airflow.
USE & OPERATION
TOUCH SCREEN CONTROL PANEL
CONTROL PANEL
(5)(1)(4)(6) (7)(2)(3)(3)
(1) Timer Control
(4) Mode Control
(7) Timer Light
POWER CONTROL
The Power Control turns the unit on and off. When the unit is plugged in, this button lights up indicatingit is in a Standby Mode ready to be switched on anytime.
Cooling Mode
•
The unit works as an air conditioner. Adjust fan speed and air temperature to suit your desired comfort
level. Temperature setting range is 16°C- 32°C (61°F- 89°F).
(2) Fan Speed Control
(5) Power Control / Standby Mode
MODE CONTROL
3 settings: Cool, Dehumidify, Fan.
A light will indicate which setting is currently
being used.
EN4
(3) Timer / Temperature Set Controls
(6) Warning Light (when flashing)
USE & OPERATION (CONTINUED)
FUNCTION BUTTONS (CONTINUED)
••Dehumidifying Mode
Air is dehumidified as it passes through the unit, without being in full cooling mode. If room temperature is higher than 25°C (77°F) fan speed can be adjusted; otherwise fan speed is preset to LOW.
Note: If the unit will be used mainly as a dehumidifier, do not connect the exhaust hose and let the
warm air return in the room. Continuous drainage is then necessary and more efficient (refer to
Continuous Draining).
Fan Mode
For air circulation without air conditioner cooling.
FAN SPEED CONTROL
3 settings: High, Medium and Low.
2 settings: High and Low.
TIMER CONTROL
While the unit is turned on, press the timer button then press the ▼ or ▲ to select the number of hours
you would like the unit to continue to run. The unit will turn off automatically.
AUTO TURN OFF:
While unit is running, press the press the ▼ or ▲ button to select the number of hours you want the unit
to run in air conditioning mode.
AUTO TURN ON:
When unit is in a standby mode (plugged in with power light on), then press the ▼ or ▲ button to select
the number of hours until you want the unit to automatically start running.
TEMPERATURE / TIMER SET CONTROLS
Used for adjusting the timer and thermostat.
•
The default display is room temperature.
•
In cooling mode, when ▼ or ▲ button is pressed, the set temperature is displayed and may be
•
adjusted. After 10 seconds the display will revert back to room temperature. Temperature is only
adjustable in cool mode. The time is adjustable between 1~24 hours.
Note: By pressing both ▼/ ▲ set buttons at the same time, the display will toggle between Celsius
and Fahrenheit.
WARNING LIGHT
Condensed water may accumulate in the unit. If the internal tank becomes full, the Power Control light will flash and the unit will not operate until the unit has been drained (refer Water Condensation
illuminate
Drainage).
After switching the air conditioner off, you must wait 3 minutes before switching it back on
again.
Warning Light will
EN5
USE & OPERATION (CONTINUED)
REMOTE CONTROL
The functions work the same as the portable air conditioner's Touch Screen Control Panel.
The functions work the same as the portable air conditioner's Control Panel.
All key functions can be accessed from the remote control.
All key functions can be accessed from the remote control.
Power Control
ON / OFF
Fan Speed Control
• HIGH • MEDIUM • LOW
Timer Control
In running mode: Auto switch off
In stand-by mode: Auto switch on
Press ▼ or ▲ button to adjust the
time setting for 1 hour intervals.
Note:
•
Battery Installation: Remove the cover on the back of the remote control and insert two AAA batteries
with + and - pointing in the proper direction according to the polarity markings.
Temperature / Timer Set
Used for adjusting the timer and temperature.
•
When ▼ or ▲ key is pressed in cool mode, the
•
set temperature is displayed and may be
adjusted. After 10 seconds the display will
revert back to room temperature.
Timer setting is available from 1-24 hours by
•
pressing the key ▼ or ▲
Mode Control
Press this button to change the operation mode
in the order of:
CoolDehumidify
Fan
Caution:
•
Use only two AAA or IEC R03 1.5V batteries.
•
Remove the batteries if the remote control is not in use for a month or longer.
•
All batteries should be replaced at the same time, do not mix with old batteries.
•
Properly dispose of used batteries.
This device complies with part 15 of the FCC Rules. Operation is subject to following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment dose cause
harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment info an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/ TV technician for help.
Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate
the equipment.
EN6
CLEANING & MAINTENANCE
Appliance Maintenance:
1.
Turn off the appliance before disconnecting the power supply.
2.
Always clean the appliance with a soft dry cloth.
Air Filter Maintenance:
The air filter should be cleaned every two weeks. Clean it as follows:
1.2.Turn off the appliance and remove the air filter .
Rinse it in lukewarm water. After cleaning, dry in a shaded and
cool place, then reinstall.
End of Season Storage & Maintenance:
If the appliance will not be used for a long time:
1.
Be sure to drain the left-over water condensation. Remove the lower drain plug and use a
shallow pan to collect the water (make sure to replace the drain plug when finished).
2.
To dry excess moisture, run the unit in Fan only mode for 30 minutes before storing.
3.
Turn off and unplug the air conditioner from the power supply.
4.
Remove the air filter and clean with water. Dry the air filter and then reinstall onto the unit.
5.
Disconnecting the Window Installation Kit:
Remove the Plastic Hose from the unit by pressing the release button located on the right side of
•
Remove the Plastic Hose from the unit by pulling away from the unit at the same time.
•
the Hose and then sliding the Hose to the right side.
Remove the Window Bracket, Window Bracket Panel Adapter and Hose Connector.
•
•
Remove the Window Bracket, Window Bracket Panel Adapter and Hose Connector.
It is recommended to store the Window Kit parts in a bag together with the Remote Control and
•
•
It is recommended to store the Window Kit parts in a bag together with the Remote Control and
placing them together with the air conditioner unit.
placing them together with the air conditioner unit.
If needed, you can clean the Window Kit with a damp cloth and water before storing. Make sure all
•
•
If needed, you can clean the Window Kit with a damp cloth and water before storing. Make sure all
parts of the Window Kit are dry before storage.
parts of the Window Kit are dry before storage.
Air filter
6.
Cover the air conditioner with a cloth/ plastic bag before storage, to protect from dust and scratches
collecting on the surface of the unit.
It is recommended to coil the power cord and store it away from the floor to ensure the cord is
7.
protected from bents and creases.
Store the air conditioner in a cool, dry place, away from direct sunlight.
8.
EN7
WATER CONDENSATION DRAINAGE
WATER CONDENSATION DRAINAGE
When there is excess water condensation inside the unit, the air conditioner stops running and shows a
warning light (the Power Control button flashes with a red light). This warning light indicates that the
water condensation needs to be drained using the following procedures:
Manual Draining for AC & Dehumidifier Mode
Water may need to be drained in high humidity areas.
1.
Unplug the unit from power source.
2.
Place a shallow pan under the lower drain plug. See
diagram.
Remove both the plastic cap and lower drain plug.
3.
Water will drain out and collect in the shallow pan.
4.
After the water is drained, replace the lower drain plug
5.
firmly.
You can now turn on the unit.
6.
Continuous Draining for Dehumidifier Mode
While using the unit in dehumidifier mode, continuous
drainage is recommended.
1.
Unplug the unit from the power source.
2.
Remove the upper drain plug. While doing this
operation some residual water may spill so please
have a pan to collect the water.
Connect the drain connector to a ¾” hose or standard
3.
garden hose (not included). See diagram.
The water can be continuously drained through the
4.
hose into a floor drain or sink.
You can now turn on the unit.
5.
Shallow Pan
(Not included)
UpperDrain Plug
Plastic Cap
& Lower
Drain Plug
Water Drain Pipe
EN8
TROUBLESHOOTING GUIDE
The following troubleshooting guide addresses the most common problems. If problems persist, call
customer service. Unplug and disconnect the appliance from the power source before attempting to
troubleshoot.
PROBLEMPOSSIBLE CAUSESOLUTION
The air conditioning
unit does not start
Runs a short while
only
Runs but not coolingA door or window is open.
Will not run and Power
button is blinking
(water full indicator)
No electricity.
•
Batteries in the remote control need
•
to be replaced.
The power cord is not properly
•
plugged in.
The safety LCDI plug has tripped
•
(USA / Canada / Mexico only).
The thermostat temperature setting
•
is too close to room temperature.
Air outlet is blocked.
•
There are tight bends in the air
•
exhaust hose.
•
The air filter is dirty.
•
The exhaust hose is detached.
•
Temperature setting is too high.
•
Air outlet or intake is blocked.
•
Excess water condensation inside
•Drain the water (refer to Water
the tank.
Check for power.
•
Change remote control batteries.
•
Remove and reconnect the
•
power cord.
Reset the safety LCDI plug, if
•
problem persists contact our
customer support (USA /
Canada / Mexico only).
Lower the set temperature.
•
Make sure the exhaust hose is
•
properly connected.
Connect exhaust hose as per
•
instructions on page 4.
Make sure the window or door
•
is closed.
Clean the air filter.
•
Reinstall exhaust hose properly
•
(refer to Installation section).
Reduce temperature setting on
•
control panel.
Remove blockage.
•
•
Condensation Drainage).
EN9
Loading...
+ 22 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.