Q: Can you briefly tell me the compression set in the decompressor on condition?
A: For conditions where the decompressor is activated, the breaking pattern is set at a standard compression of 500 + 100 kPa (5 + 1 kg/cm²).
Q: For the camshaft, what is the maximum lift that can be obtained while turning anticlockwise and what is its tolerance range?
A: The appropriate range on the intake camshaft lift is 31.155—31.315 mm (1.2266—1.2329 in).
Q: What type of tool do I use to check for warpage in the cylinder head?
A: For wliarps checking in the cylinder, heads use a straight edge and feeler gauge with a service limit of 0.10 mm (0.004 in).
Q: Can you tell me the torque specifications of the bolts for the cylinder head?
A: The standard torque for a cylinder head for such a device is 36 N-m (3.6 kg-m, 26 ft-lb)
Q: In a perfect world, how many hours should the valve seat persenine and resurfacing be done?
A: As a matter of fact, the valve seats can be resurfaced every time new valve guides are installed.