Honda WSP100 Owner's Manual

OPERATOR'S MANUAL
SUBMERSIBLE PUMP
WSP50AA•WSP100AA
© 2004-2011 American Honda Motor Co., Inc. All Rights Reserved
BY:
BY:
POM31WSP802
AHM.750.2011.02
Printed in USA
Thank you for purchasing this Honda Stainless Steel Sump Pump. We hope you are pleased with your purchase and that our pumps will provide you with long service life and exceptional performance.
To ensure satisfactory service life, there are several considerations regarding proper installation, operation, and power source. Please review the recommendations outlined within this operator's manual.
Please contact your supplier (supplying dealer or contractor) if service is necessary or if you have any questions or need further assistance.
Please retain the following information for your records and to help expedite service:
Purchase Date: ___________________________
Purchased From: ___________________________
___________________________
Serial No: ___________________________
(Located on the pump nameplate)
USE AND MAINTENANCE INSTRUCTIONS

1. MANUFACTURER AND PUMP IDENTIFICATION DATA

1.1 MANUFACTURER DATA

EBARA INTERNATIONAL CORPORATION 1651 CEDAR LINE DRIVE ROCK HILL, SC 29730

1.2 PUMP DATA

Description: Model: Year of manufacture:
SUBMERSIBLE SOLIDS PUMP WSP50AM, WSP50M, WSP100AM, WSP100AA see plate on the pump.

2. INFORMATION ON TECHNICAL ASSISTANCE

If the malfunction of the pump is not among those included in the troubleshooting table (see “14.2 TROUBLESHOOTING ” on page 10), contact the nearest authorized Honda pump dealer.

3. INTRODUCTION

This publication contains all the necessary information and instructions for use and maintenance of your submersible sewage pump. Follow the advice given to obtain optimum performance and correct operation of the pump. For any other information you may require, please contact the nearest appointed distributor.
IT IS STRICTLY FORBIDDEN TO REPRODUCE THE ILLUSTRATIONS AND THE TEXT, EVEN IN PART.
1

4. CONTENTS

1. MANUFACTURER AND PUMP IDENTIFICATION DATA. . . . . . . . . . . . .page 1
1.1 MANUFACTURER DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 1
1.2 PUMP DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 1
2. INFORMATION ON TECHNICAL ASSISTANCE . . . . . . . . . . . . . . . . . . .page 1
3. INTRODUCTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 1
4. CONTENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 2
5. GENERAL SAFETY WARNINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 3
5.1. PREVENTIVE MEASURES TO BE TAKEN BY THE USER . . . . .page 3
5.2 GENERAL SAFETY WARNINGS . . . . . . . . . . . . . . . . . . . . . . . . . .page 3
6. GENERAL DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 4
7. TECHNICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 4
7.1. PUMP TECHNICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 4
7.2. MOTOR TECHNICAL DATA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 5
8.RECOMMENDED AND NON-RECOMMENDED USE . . . . . . . . . . . . . . .page 5
8.1 RECOMMENDED CONDITIONS OF USE . . . . . . . . . . . . . . . . . . .page 5
8.2 NON-RECOMMENDED CONDITIONS OF USE. . . . . . . . . . . . . . .page 6
9. HANDLING AND TRANSPORT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 6
9.1 UNPACKING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 6
9.2 HANDLING AND DISCONNECTING. . . . . . . . . . . . . . . . . . . . . . . .page 6
9.3 TRANSPORT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 7
10. INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 7
10.1. FIXED INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 7
10.2. TEMPORARY INSTALLATION (FOR TEMPORARY USE) . . . .page 7
11. ASSEMBLY AND DISASSEMBLY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 8
12. PREPARATION FOR USE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 8
12.1. ELECTRIC CONNECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 8
12.2. ADJUSTING AND REGISTERING . . . . . . . . . . . . . . . . . . . . . . .page 8
13. USE AND START-UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 8
14. MAINTENANCE AND REPAIRS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 9
14.1 MAINTENANCE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 9
14.2 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 10
15. ILLUSTRATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 11
15.1 INSTALLATION WITH MINIMUM FUNCTIONAL SPACES . . . .page 11
15.2 PUMP IMPELLER COVER DISASSEMBLY . . . . . . . . . . . . . . . .page 12
15.3 WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 13
16. WARRANTY SERVICE INFORMATION . . . . . . . . . . . . . . . . . . . . . . . .page 14
2

5. GENERAL SAFETY WARNINGS

FAILURE TO OBSERVE THESE WARNINGS AND/OR TAMPERING WITH THE PUMP RELIEVES THE MANUFACTURER OF ANY RESPONSIBILITY IN THE EVENT OF DAMAGE TO PERSONS OR OBJECTS AND/OR TO THE PUMP.
Before starting the pump it is important for the user to know how to perform all the operations described in this manual and
or maintenance of the pump.
use

5.1. PREVENTIVE MEASURES TO BE TAKEN BY THE USER

The user must comply with all the accident-prevention regulations in force in the country in which the pump is being used; the indications given in chapters 7.1 and 7.2 must be scrupulously
followed.
During pump repairs or maintenance, remove the plug from the socket and/or turn off the switch (if provided), thus interrupting the
supply of electric power to the pump. This will prevent accidental starting which could cause damage to persons and/or objects. All maintenance operations, installations, or shifting of the pump with the electric system live may cause severe or fatal injury. During operation, avoid moving or shifting the pump. Before using the pump, always check that the cable and all the electric devices are in working condition. Never start the pump by inserting the plug in the socket and/or switching on the switch with bare feet, with your feet in the water, or with wet hands.
The user must not carry out under his own initiative any operations or jobs not recommended in this manual.
to apply them at all times during

5.2 GENERAL SAFETY WARNINGS

WSP50 AND WSP100 pumps are designed in such a way that all
the moving parts are protected by the use of casings. The
manufacturer declines all responsibility in the event of damage
caused as a result of tampering with these devices.
Each lead or live part is electrically insulated to ground; there is
also a further safety device in that the accessible conductive parts
are connected to a ground lead so that the parts within reach do
not become electrically charged in the event of failure of the
principal insulation.
3

6. GENERAL DESCRIPTION

WSP50 and WSP100 series pumps are all similar from the functional and constructive point of view; the only differences are the following:
•Power
• Flow rate
•Head
•Weight
• Dimensions
WSP50 and WSP100 series pumps are used for handling water, even at high temperatures (see “7.1. PUMP TECHNICAL DATA” on page 4). Thanks to their small bulk and ease of transport, they may be used for fixed or temporary installations, with or without automatic start.
These pumps guarantee long life and constant performance if used according to the conditions given in section 8 on page 5 and section 14 on page 9.

7. TECHNICAL DATA

7.1. PUMP TECHNICAL DATA

Max. fluid temperature 104°F/40°C Max. dimension suspended solids 2 inches Max. immersion depth 33 feet Length of power cable 25 feet Type of impeller single channel Type of seal on the shaft double mechanical seal in an oil
chamber Type of bearing shielded ball bearing Delivery diameter 2-inch NPTF Impeller material stainless steel Pump structure material stainless steel Motor structure material stainless steel Seal cover material stainless steel Intake side cover material stainless steel Pump body variable features threaded with feet