Hilti PX1XTR1 Users Manual

PX 10 Transpointer - Operating Instructions
______________________________________________________________________________ It is essential that the operating instructions are read before the tool is used for the first
time.
Always keep these operating instructions together with the tool.
Ensure the operating instructions are with the tool when it is given to other persons .
1. General information
2. Description
3. Tools and accessories
4. Technical data
5. Safety precautions
6. Before use
7. Operation
8. Applications
9. Calibration
10. Care and maintenance
11. Disposal
12. Warranty
13. FCC and IC statements
14. EC declaration of conformity
Component parts
1. Transmitter PX 10T
2. On/Off key
3. Status indication light
4. Indentations for adhesive putty
5. Battery compartment
6. Hand strap PDA 60
7. Receiver PX 10R
8. On/Off key
9. Direction arrows
10. Display a. Battery status b. Signal status c. Measuring units d. Distance
11. Marking notch
12. Battery compartment
13. Hand strap PDA 60
14. Slope adapter PXA 70
15. Holder for PX 10R
16. Scale showing angle of measurement
17. Adjustment thread
18. Reference point
19. Marking notch
1. General information
1.1 Safety notices and their meaning
-WARNING-
The word WARNING is used to draw attention to a potentially da ngerous situation which could lead to severe personal injury or death.
-CAUTION-
This word indicates a possible hazardous situation which could result in slight bodily injuries or damage to property.
User Manual.doc Seite 1 von 9
Gelöscht: E_Transpointer_PX 10_22.01.06
-NOTE-
Draws attention to instructions and other useful information.
1.2 Pictograms
Warning signs
Symbols
1 These numbers refer to the corresponding illustratio ns. The illustrations can be found in the fold-out cover pages. Keep these pages open when studying the operating instructions . In these operating instructions, the PX 10 Transpointer is referred in it’s two components. The PX 10T as the “transmitter”. The PX 10R as the “receiver”. Or in general as the “tools”.
1.3 Location of the identification data on the tools
The type designation and serial number can be found on the ty pe designation plate on the tool. Make a note of this data in your operating instructions and always refer to it when making an enquiry to your Hilti representative or service department.
Type: PX 10T Serial no.:
Type: PX 10R Serial no.:
2. Description
The PX 10 is a system built up of a transmi tter and a receiver. The receiver is used to find the di r e ction the transmitter is pointing, and for finding the distance between the two devices.
2.1 Intended use
The Transpointer is used to align the receiver position to the preset transmitter position. The system is capable of this function through walls and ceilings, as well as determining the distance between the devices. The operator can transfer points from one side of a wall to another, and determine at the same time the wall thickness. This helps:
- to check where a marked entry point for a through hole will exit.
- to determine what length drill bit or core is needed
- to transfer positions
The Transpointer may also be used in conjunction with the slope adapter to:
- To find a exit point from a given reference point and angle
- Find the angle between two points
2.2 Items supplied
1 PX 10T transmitter 1 PX 10R receiver 2 PDA 60 hand straps 2 Type 9 volt batteries 1 PUA 91 adhesive putty (general) 1 PUA 92 adhesive strips (interior) 1 Operating instructions 2 Producer certificate 1 Hilti case 1 PXA 70 slope adapter* 10 PUA 70 markers*
* depending on the version purchased these items, may not be included in the supplied items.
User Manual.doc Seite 2 von 9
Gelöscht: E_Transpointer_PX 10_22.01.06
2.3 Measuring principle
The transmitter generates a magnetic field. This field can penetrate bricks, wood, concrete, and concrete with metal reinforcement. The field is however affected by metal. Whilst normal reinforcement in concrete is not a problem, welded reinforcement, reinforcement mesh, flat metal sheet or massi ve me tal beams can have a considerably negative effect on the system performance . The receiver is calibrated to find the center point of the projec ted field and to determine the distance by the measurement of the strength of the magnetic field between the two tools. The slope adapter has been developed in conjunction with the Transpointer, so that the magnetic fields can also be measured when the devices are inclined to each other.
3. Accessories
Adhesive putty PUA 91 Adhesive strips PUA 92 Hand strap PDA 60 Slope adapter PXA 70 Markers PUA 70
4. Technical data
Position accuracy, typical ±8mm for every 200mm of thickness up to 1m at 21°C
(+70°F)
Thickness accuracy, typical ±5% of thickness up to 1m at 21°C (+70°F)
(excluding slope adapter)
Position accuracy, maximum ±2mm for every 200mm of thickness up to 1m at 21°C
(+70°F) without the influence of metal
Thickness accuracy, maximum ±5% of thickness up to 1m at 21°C (+70°F) without the
influence of metal
(excluding slope adapter) Operating range (typical) 50mm to 1.35m (2” to 4’ 5”) Operating temperature (PX 10T, PX 10R, PUA 91) -10°C to +55°C (+14°F to +131°F) Operating temperature (PUA 92) +10°C to 40°C (+50°F to +104°F) Storage temperature -25°C to +70°C (-13°F to +158°F) Power supply (PX 10T, PX 10R) 1 x size E-Block battery (9 V) Life time (PX 10T, PX 10R) 17 hours at +21°C (+70°F) Protection class (excluding battery compartment) IP 56 Protected against dust and powerful water jets Weight with battery (PX 10T) 190g (0.42lb) Weight with battery (PX 10R) 230g (0.51lb) Dimensions (PX 10T) 160mm x 95mm x 33mm (6.3” x 3.8” x 1.3”) Dimensions (PX 10R) 210mm x 95mm x 33mm (8.3” x 3.8” x 1.3”) Slope adapter range 90° to 45° (0° to 45°) Slope adapter maximal accuracy ±2°
-CAUTION­The accuracy can be strongly degraded if welded metal reinforcement or metal sheets or supports are close to the tools. The thickness measurement in case of welded reinforcement is typically 20% thicker than actual.
5. Safety precautions
-WARNING­Read and understand all instructions. Failure to follow all instruction listed below may result in serious personal injury.
5.1 Basic information concerning safety
In addition to the information relevant to safety given in each of the sections of these operating instructions, the following points must be strictly observed at all times.
- Tampering with or modif i cation of the tool is not permissible.
User Manual.doc Seite 3 von 9
Gelöscht: E_Transpointer_PX 10_22.01.06
Loading...
+ 6 hidden pages