Hill-Rom Century CC In-service manual

Century CC® Bed

TABLE OF CONTENTS

FEATURES...................................................................................................1
DIMENSIONS.............................................................................................1
BED CONTROLS
Hi-Lo.......................................................................................................2
Head With Automatic Contour .........................................................2
Head Only............................................................................................2
Knee......................................................................................................3
Trendelenburg/Reverse Trendelenburg ...........................................3
Vascular ................................................................................................3
Cardiac Chair......................................................................................3
Electric Control Lockouts ...................................................................3
FEATURES
Siderails .................................................................................................4
Central Brake and Steer.....................................................................4
Permanent IV Pole ..............................................................................4
Instant CPR ..........................................................................................5
Headboard Removal .........................................................................5
Convertible Footboard ......................................................................5
C-arm Interfacing................................................................................6
Other Features.....................................................................................6
OPTIONS
Integrated Air Support System...........................................................7
SideCom
Low Leakage .......................................................................................7
Scale .................................................................................................8–9
ACCESSORIES
2 Tank Holder......................................................................................9
O
X-Ray Cassette Holder................................................................10–11
ISS System ...........................................................................................12
Transducer Holder.............................................................................12
IV Pole.................................................................................................12
Trapeze Support Bracket..................................................................12
Cane Bumpers...................................................................................12
Siderail Pads.......................................................................................12
Chartholder .......................................................................................12
CLEANING/REMOVAL OF DYNAMICAIRE™ SLEEP SURFACE .............13
SAFETY TIPS.............................................................................Back Cover
NOTE An In-Service videotape is available. Contact your
Hill-Rom representative or call 1-800-445-3720.
® Communication System..................................................7
FOR SPECIAL ASSISTANCE:
Hill-Rom Account Manager
Clinical Consultant
________________________________________________
Field Service Technician
Customer Service Representative
________________________________________
__________________________________________
__________________________________
Phone
Phone
Phone
Phone
______________________________
______________________________
______________________________
______________________________
1

DIMENSIONS

FEATURES

Measurements: Inches (centimeters)
Head Elevation
Indicator
(Both Sides)
Drainage Bag Hooks
(Both Sides
And Foot End)
IV Pole
Storage Area
Manual Control
For Bed Positioning
Including Instant CPR
Pump/Release Pedals
For Manual Control
(Both Sides)
Integrated Air Support
System Controls
(Optional)
Siderail
Nurse Controls
(Both Sides)
SideCom
®
Communtication System
(Optional)
Siderail Patient
Controls
(Both Sides)
Convertible
Footboard
Trendelenburg/
Reverse Trendelenburg
Controls
Patient Scale
(Optional)
Motor Power
Switch
Electric Controls
Lockout Panel
Removable Headboard
Permanent
IV Pole
TuckAway
Siderails
8" Polyurethane Carpet Casters
(6" Polyurethane
Carpet Casters Optional)
Central Brake And Steer
(Both Ends)
DynamicAire
Sleep Surface
(Optional)
IV Pole Sockets
(One At
Each Corner)
Restraint Strap Holders;
Head, Thigh, Foot End
(Both Sides)
91.0 (231)
93.5 With Roller Bumpers (243)
57.0 (145)
8" Casters
55.5 (140) High
37.5 (97) Low
6" Casters
54.3 (137) High
36.3 (94) Low
8" Casters
40.5 (102) High/22.5 (57) Low
6" Casters
39.3 (99) High/21.3 (54) Low
38.5 (98)
34.0 (86)
23.5 (60)
15.0 (38)
8" Casters 6.5 (17) 6" Casters 4.6 (12)

BED CONTROLS BED CONTROLS

Introduction: The Century CC Bed is designed to use electric and/or manual controls.
ELECTRIC CONTROLS
Hi-Lo Push Button
Knee And Head
Push Button
Knee Function Lockout
Hi-Lo Function Lockout
Head Function Lockout
MANUAL CONTROLS
Manual Foot Pedals
Mode Selector Dial
NURSE CONTROL PANEL
Trendelenburg/
Reverse Trendelenburg
Angle Indicator
Auto Contour Lockout

HI-LO

For Electric:
Locate the Hi-Lo control on the outside of either
To raise: push the G button then release…
To lower: push the H button then release.
SAFETY TIP If the bed is occupied and unattended, the bed should stay in the low position and the mode selector dial should not be in the Hi-Lo mode.
HEAD WITH AUTOMATIC
For Electric:
When head of bed is raised,the knee will
CONTOUR
Locate the head control button on the inside of
To raise: push the head G button then release…
To lower: push the head H button then release.

HEAD ONLY

For Electric:
Insure the Automatic Contour lockout control
Locate the head control button on the inside of
To raise: push the head G button then release…
To lower: push the head H button then release.
Hi-Lo Bed Control Patient Scale Monitor
head end siderail or at the foot end nurse control panel
automatically elevate.(Automatic contour may be eliminated by pushing up the contour lockout at the nurse control panel. See Electric Control Lockouts)
either head end siderails
located at the nurse control panel is pushed up
either head end siderails
(See Page 8–9)
For Manual:
Turn mode selector dial to “Hi-Losection
To raise: pump the green pedal located on either side of the bed
To lower: push the orange pedal on either side of
the bed.
For Manual:
No manual automatic contour control.
SAFETY TIP The automatic contour feature prevents the patient from gravitating to the foot end of the bed, thus reducing patient repositioning
For Manual:
Turn the mode selector dial to the “Head”section…
To raise: pump the green pedal…
To lower: push the orange pedal.
NOTE A head elevation gauge located on both sides of the bed indicates the degree of head elevation.
32

KNEE

TRENDELENBURG

REVERSE TRENDELENBURG

VASCULAR

CARDIAC CHAIR

ELECTRIC CONTROL LOCKOUTS

SAFETY TIP Whenever a patient should be restricted from operating
the patient controls, activate the appropriate lockout control.This is especially true for mentally compromised patients and for patients in traction.
Motor Power Switch
For Electric:
Locate the knee control button on the inside of either head end siderail
To raise: push the G button then release…
To lower: push the H button then release.
For Manual:
Turn the mode selector dial to the “Kneeposition
To raise: pump the green pedal…
To lower: push the orange pedal.
For Manual:
Grasp the foot end section of the sleep surface and lift up (two positions are available)
Insure the foot rack is properly engaged.
To Level The Sleep Surface:
Lift the foot section to release the foot rack…
Grasp the rack and pivot downward…
Lower the foot section.
For Manual or Electric:
Place the bed in 12˚ Reverse Trendelenburg…
Manually or electrically raise the head of the
bed to 60˚(See Head)
Manually or electrically raise the knee of the bed to 35˚(See Knee).
To Level The Sleep Surface:
Manually or electrically lower the knee and head of the bed unit until flat
Place the bed in 0˚ Reverse Trendelenburg.
Siderail Lockout Controls:
Located in the nurse control panel, the respective lockout function will cancel the HI-LO,KNEE, HEAD and CONTOUR electric controls.
Push the button up – electric control is inoperable
Push the button down – electric control is operable.
Patient Control Lockout Indicator:
Located below the nurse control panel, the indicator illuminates in red when lockout controls are being used.
Motor Power Switch:
Located at the foot end base of the bed,this control will turn off ALL electric controls.
Press on electric controls are operable
Press off – electric controls are inoperable.
SAFETY TIP Before lifting or lowering, make sure both Trendelenburg/Reverse Trendelenburg release handles are fully gripped and touching the bumpers.
For Manual:
If necessary, raise the bed using the HI-LO Control located at the nurse control panel until bed reaches desired height
Grip both of the Trendelenburg/Reverse Trendelenburg handles located at the foot end of the bed
Lift for Trendelenburg or lower for Reverse Trendelenburg
To adjust for desired degrees,refer to the Trendelenburg Angleindicator located to the right on the nurse control panel…
Release handles to lock position.Confirm locking
by attempting to move the sleep surface up or down.
To Level The Sleep Surface:
Grip both handles to release the sleep surface
Raise or lower the foot end of the bed until theTrendelenburg Angleindicator reads zero
Release handles to lock position.Confirm locking
by attempting to move sleep surface up or down.
Trendelenburg/Reverse
Trendelenburg Release Handle
Loading...
+ 11 hidden pages