Hanna Instruments HI 9060 User Manual

Instruction Manual
HI 9060
Portable Waterproof
Microprocessor-based
Thermistor
Thermometer
This Instrument is in
www.hannainst.com
Compliance with CE
Directives
Dear Customer, Thank you for choosing a Hanna product. This manual will provide you with the necessary information for correct opera­tion. Please read it carefully before using the meter. If you need additional technical information, do not hesitate to e­mail us at tech@hannainst.com.
This instrument is in compliance with the directives.
PRELIMINARY EXAMINATION
Remove the instrument from the packing material and examine it carefully to make sure that no damage has occurred during shipping. If there is any noticeable damage, notify your Dealer or the nearest Hanna Office.
Note: Save all packing materials until you are sure that the
instrument functions correctly. Any defective item must be returned in the original packaging together with the supplied accessories.
FUNCTIONAL DESCRIPTION
Range Resolution Accuracy
Typical EMC Deviation
Display Battery Type
Life Probe (included) Environment Dimensions Weight
SPECIFICATIONS
-50.0 to 150.0°C / -58.0 to 302.0°F
0.1°C or 0.1°F
±0.4°C / ±0.8°F
excluding probe error
±1°C / ±2°F, with HI 765BL probe
Dual-line LCD
4 x 1.5V AA (IEC LR6)
approx. 3000 hours of continuous use
HI 765BL with 1 m (3.3') cable
-10 to 50ºC (14 to 122ºF); RH 100% 196 x 80 x 60 mm (7.7x3.1x2.4")
425 g (15 oz) meter only
WARRANTY
All Hanna Instruments meters are warranted for two years against defects in workmanship and materials when used for their intended pur­pose and maintained according to instructions. Sensors and probes are warranted for a period of six months. This warranty is limited to repair or replacement free of charge. Damages due to accidents, misuse, tampering or lack of prescribed main­tenance are not covered. If service is required, contact the dealer from whom you purchased the instrument. If under warranty, report the model number, date of purchase, serial number and the nature of the failure. First obtain a Returned Goods Authorization number from the Customer Service department, then return the instrument with the Authorization # included along with shipment costs prepaid. If the repair is not covered by the warranty, you will be notified of the charges. When shipping any instrument, make sure it is properly packaged for complete protection.
All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner, Hanna Instruments Inc., Woonsocket, Rhode Island, 02895 , USA.
Hanna Instruments reserves the right to modify the design, construction and appearance of its products without advance notice.
GENERAL DESCRIPTION
HI 9060 is a waterproof, microprocessor-based, thermistor thermometer, ideal for use in wet and humid environments.
The meter is also provided with low battery detection and BEPS (Battery Error Preventing System), which turns the unit off when the batteries are discharged avoiding errone­ous readings caused by low battery level.
HI 9060 features include a dual-level LCD for simultaneously displaying of maximum and minimum measured tempera­tures, °C/°F selection button and hold function.
Each meter is supplied complete with HI 765BL temperature probe, 4 x 1.5V AA batteries and instruction manual.
1. Battery cover
2. Temperature probe connector
3. Liquid Crystal Display
4. ON/OFF Key
5. Measuring unit selection key
6. HOLD measurement key
7. HI/LO values reset key
1. Current temperature value
2. HOLD indicator
3. Low Battery indicator
4. Minimum temperature value
5. Maximum temperature value
6. Measuring scale, °C or °F
CE DECLARATION OF CONFORMITY
ISTR9060 01/03
OPERATIONAL GUIDE
Note: Although the display is frozen, internally the meter
continues measuring and updating Hi and Lo values.
FACTORY RECALIBRATION
TEMPERATURE PROBES & ACCESSORIES
INITIAL PREPARATION
Each meter is supplied complete with batteries.
Remove the back cover, unwrap the batteries and install them while pay­ing attention to their polarity.
Connect the temperature probe to the connector on the top of the meter.
To switch on, press the ON/OFF key on the front of the meter.
If the meter does not come on, make sure that the batteries are correctly installed.
The thermometer will carry out a self diagnostic test routine, the LCD will show all segments for a few seconds (or as long as ON/OFF is held), followed by the percentage indication of the remain­ing battery life.
The thermometer then enters normal measurement mode. If a temperature probe is plugged in, the meter displays
the measured temperature. If no probe is plugged in, or if reading is over-range, the display shows flashing dashes. If a measurement is slightly over the range of the meter specifications, the display flashes the closest full-scale value. To switch the thermometer OFF, press the ON/OFF key.
MEASURING SCALE (°C/°F)
The instrument is factory set to the °C scale, but measurements can be performed in either the Celsius or Fahrenheit scale. Press the °C/°F button to select the desired scale.
HOLD MODE
The HOLD function is activated by pressing the HOLD key. The measured temperature is held on the display until HOLD is pressed again. The "H" tag blinks on the display to indicate the HOLD mode.
HIGH/LOW TEMPERATURES
The maximum and minimum tem­peratures are continuously monitored and displayed in the lower portion of the LCD.
Note: When reading goes over-range, the Hi and Lo values
display dashes until cleared.
CLEAR FUNCTION
Upon pressing the CLEAR key, the current reading is assigned to the highest and lowest temperature val­ues. The High/Low values may be cleared at any time during measure­ment.
BATTERY REPLACEMENT
The instrument is powered by four 1.5 V alkaline batteries and is provided with the Battery Error Prevention System (BEPS), which turns the unit off when a low battery signal is detected.
When the remaining battery level is less than 10%, a warning symbol blinks on the display to indicate a low battery condition.
It is recommended to replace the batteries as soon as the low battery condition is detected.
Battery replacement must only take place in a nonhazard­ous area using four 1.5V alkaline batteries.
In order to replace rundown batteries, simply remove the two screws on the rear cover of the instrument and replace the four batteries with new ones paying attention to the correct polarity.
Reattach the cover and tighten the two screws.
All Hanna thermometers have been accurately pre-calibrated at the factory.
It is recommended to have all thermometers recalibrated at least once a year. For an accurate annual recalibration, contact your nearest Hanna Service Center.
Hanna Accuracy Test Plugs provide a quick and easy way to test the meter's accuracy by simply connecting these Test Plugs to the probe connector of the meter. If the reading differs by more than ±0.4°C (±0.8°F) from the Test Plug value, the meter is due for recalibration. Choose the Test Plug closest to your measurement range to best suit your needs:
HI 765-18C Calibration key, –18.0°C HI 765000C Calibration key, 0.0°C HI 765070C Calibration key, 70.0°C HI 765-004F Calibration key, –0.4°F HI 765032F Calibration key, 32.0°F HI 765158F Calibration key, 158.0°F
Recommendations for Users
Before using these products, make sure that they are entirely suitable for the environment in which they are used. Operation of these instruments in residential areas could cause unacceptable interference to radio and TV equipment, requiring the operator to take all necessary steps to correct interference. Any variation introduced by the user to the supplied equipment may degrade the instruments' EMC performance. To avoid electrical shock, do not use these instruments when voltage at the measurement surface exceeds 24VAC or 60VDC. To avoid damage or burns, do not perform any measurement in microwave ovens.
Hanna offers a wide range of probes to meet your needs with air, liquid, penetration and surface measurements. All Hanna temperature probes are pre-calibrated at the factory and ready-to-use. These interchangeable probes make it possible to switch from one probe to another without requiring recalibration. Hanna probes are also available in different handle colors to avoid cross contamination during testing.
PROBES WITH 1 m (3.3’) CABLE
HI 765A Air probe with white handle HI 765BL General purpose liquid probe with black handle HI 765L General purpose liquid probe with white handle HI 765PBL General purpose penetration probe with blue
handle
HI 765PG General purpose penetration probe with green
handle
HI 765PR General purpose penetration probe with red
handle
HI 765PW General purpose penetration probe with white
handle
HI 765PWL Penetration probe with white handle HI 765W Wire probe without handle for hard-to-reach
places
PROBES WITH 10 m (33’) CABLE
HI 765A/10 Air probe with white handle HI 765L/10 General purpose liquid probe with white handle HI 765PBL/10 General purpose penetration probe with
blue handle
HI 765PG/10 General purpose penetration probe with green
handle
HI 765PR/10 General purpose penetration probe with red
handle
HI 765PW/10 General purpose penetration probe with white
handle
HI 765W/10 Wire probe without handle for hard-to-reach
places
OTHER ACCESSORIES
HI 710002 Soft carrying case HI 721317 Hard carrying case (340x230x90 mm) HI 721308 1.5V AA size, alkaline battery (10 pcs)
Loading...