Dear Customer,
Thank you for choosing a Hanna product.
Please read this instruction manual carefully before using the instrument.
This manual will provide you with the necessary information for correct
use of the instrument, as well as a more precise idea of its versatility.
If you need additional technical information, do not hesitate to e-mail
us at tech@hannainst.com.
These instruments are in compliance with the directives.
WARRANTY
All Hanna Instruments meters are warranted for two years against
defects in workmanship and materials when used for their intended
purpose and maintained according to instructions. Sensors and probes
are warranted for a period of six months.
This warranty is limited to repair or replacement free of charge.
Damages due to accidents, misuse, tampering or lack of prescribed
maintenance are not covered.
If service is required, contact the dealer from whom you purchased the
instrument. If under warranty, report the model number, date of
purchase, serial number and the nature of the failure.
First obtain a Returned Goods Authorization number from the Customer
Service department, then return the instrument with the Authorization
# included along with shipment costs prepaid. If the repair is not
covered by the warranty, you will be notified of the charges.
When shipping any instrument, make sure it is properly packaged for
complete protection.
TABLE OF CONTENTS
PRELIMINARY EXAMINATION ........................................................ 3
GENERAL DESCRIPTION ................................................................3
HI9041, SPECIFICATIONS ............................................................4
HI9061, SPECIFICATIONS ............................................................5
HI93501, SPECIFICATIONS ..........................................................6
HI95502, SPECIFICATIONS ..........................................................7
HI93503, SPECIFICATIONS ..........................................................8
HI935007, SPECIFICATIONS ........................................................ 9
OPERATIONAL GUIDE ................................................................. 10
FACTORY RECALIBRATION ........................................................... 13
TEMPERATURE PROBES .............................................................. 14
PRELIMINARY EXAMINATION
Remove the instrument from the packing material and examine it to
make sure that no damage has occurred during shipping. If there is
any damage, notify your dealer or the nearest Hanna Customer
Service Center.
Each meter is supplied complete with:
• Temperature probe (for HI 93501 and HI 93503 only)
• Batteries: 1 x 9V for HI 9041; 4 x 1.5V AA for HI 9061;
3 x 1.5V AA for HI 93501, HI 95502, HI 93503
and HI 935007
• Instruction manual.
Note: Save all packing material until you are sure that the
instrument functions correctly. All defective items must be
returned in the original packing with the supplied accessories.
GENERAL DESCRIPTION
Temperature plays a very important role in the food industry, and it
also has to be checked in the warehouses, loading docks and in
transportation vehicles.
You can choose the Hanna food-thermometer which best meets your
needs, among several models:
HI 9041 and HI 9061 are simple-to-operate instruments that provide
excellent accuracy and can operate with a wide range of interchangeable probes (designed for air, liquid or penetration; see page 15)
without requiring recalibration. HI 9041 and HI 9061 are available
in either °C or °F models.
HI 93501, HI 95502, HI 93503 and HI 935007 are professional,
rugged and waterproof thermometers, designed to be used on a daily
basis in industrial kitchens and catering.
Standard features include low battery detection, auto-off capability
and long battery life.
Moreover, HI 93501, HI 95502 and HI 93503 are provided with the
exclusive Cal-Check feature for checking the meter calibration status at
any time. They use interchangeable probes (see pages 14-15).
HI 935007 is a K-thermocouple thermometer. It offers a wide
temperature range, automatic change of resolution from 0.1° to 1°,
and user-selectable measurement unit (°C or °F).
32
SPECIFICATIONS OF HI 9041C & HI 9041F
SPECIFICATIONS OF HI 9061C & HI 9061F
Main features:
• HI 765 probes series
• Available HI 765 accuracy test plugs
• Remaining battery life indication / low battery detection
• Available in °C or °F models
Main features:
• HI 765 probes series
• Available HI 765 accuracy test plugs
• Remaining battery life indication / low battery detection
• Available in °C or °F models
• Waterproof casing
HI 9041
Range -50.0 to 150.0°C (HI 9041C)
-58.0 to 302.0°F (HI 9041F)
Resolution 0.1°C / 0.1°F
Accuracy ±0.4°C / ±0.8°F
excluding probe error
Typical EMC ±0.5°C / ±1°F
Deviation with HI 765BL probe
Probe HI 765 series
Battery 1x9V (6LR61) / approx. 700 hours of use
Environment -10 to 50°C (14 to 122°F);
max 95% RH non-condensing
Dimensions 180 x 83 x 40 mm (7.1 x 3.3 x 1.6")
Weight 226 g (8 oz)
HI 9061
Range -50.0 to 150.0°C (HI 9061C)
-58.0 to 302.0°F (HI 9061F)
Resolution 0.1°C / 0.1°F
Accuracy ±0.4°C / ±0.8°F
excluding probe error
Typical EMC ±0.5°C / ±1°F
Deviation with HI 765BL probe
Probe HI 765 series
Battery 4x1.5V AA (LR6) / approx. 2000 hours of use
Environment -10 to 50°C (14 to 122°F);
100% RH
Dimensions 196 x 80 x 60 mm (7.7 x 3.1 x 2.4")
Weight 425 g (15 oz)