Dear Customer,
Thank you for choosing a Hanna product. This manual will
provide you with the necessary information for correct operation. Please read it carefully before using the logger.
If you need additional technical information, do not hesitate
to e-mail us at tech@hannainst.com.
These instruments are in compliance with the directives.
PRELIMINARY EXAMINATION
Remove the instrument from the packing material and
examine it carefully. If any damage has occurred during
shipment, immediately notify your Dealer or the nearest
Hanna Customer Service Center.
Each thermologger is supplied complete with batteries and
instructions.
Note: Conserve all packing material until the instrument
has been observed to function correctly because any
defective item must be returned to the Dealer in its
original packing.
GENERAL DESCRIPTION
HI 140 series is a family of temperature loggers with
different ranges (see “Specifications” table). The user can
interact with the meter, i.e. acquire logged data or set
logger parameters, through an RS232 communication protocol and a PC.
The HI 92140 Windows® compatible software supports the
communication between the instrument and the PC through
the HI 90140 infrared transmitter. For further details, see
the program on-line help.
The HI 140 main features are: selectable logging enable/
disable; programmable high and low alarm thresholds;
programmable logging interval; logging start delay; programmable user ID; green and red LED indicators; RS232
optical communication link; non-volatile data storage in
EEPROM of logging parameters and logged data; programmable real time clock; BEPS (Battery Error Prevention
System). The loggers can memorize up to 7600 samples.
The expected battery life is about 4 years at 25°C operating
temperature.
All thermologgers are factory calibrated.
The case of the loggers is waterproof IP67. A plastic window
on the top case enables optical data transmission to the
HI 90140 infrared transmitter and status indication for the
user. The two external LEDs are used for communicating
with the transmitter, while the logger status is indicated by
the 2 central LEDs (green and red) as follows:
1. GREEN LED ALWAYS ON: this condition
occurs when the meter has been reset, i.e.
when batteries are changed, requiring a
new setting of the logger parameters.
2. GREEN LED FLASHES ONCE EVERY 4”: the
meter is logging.
3. GREEN LED FLASHES TWICE EVERY 4”: the
meter is waiting for a delayed logging
start.
4. RED LED FLASHES: an alarm condition has
occurred (at least once).
SPECIFICATIONS
Model Range Resolution Accuracy
HI 140A(H) -30.0 to 70.0°C 0.5°C ±1.5oC
-22.0 to 158.0°F 0.5°F ±3°F
HI 140B(H) -10.0 to 30.0°C 0.2°C ±0.5oC
14 to 86°F 0.4°F ±1°F
HI 140C(H) -30.0 to 10.0°C 0.2°C ±0.5°C
-22 to 50°F 0.4°F ±1°F
HI 140D(H) 20.0 to 60.0°C 0.2°C ±0.5°C
68 to 140°F 0.4°F ±1°F
HI 140E(H) -30.0 to -10.0°C 0.1°C ±0.3°C
-22 to 14°F 0.2°F ±0.6°F
HI 140F(H) 20.0 to 40.0°C 0.1°C ±0.3°C
68 to 104°F 0.2°F ±0.6°F
HI 140G(H) -5.0 to 15.0°C 0.1°C ±0.3°C
23 to 59°F 0.2°F ±0.6°F
HI 140H(H) 10 to 120°C 1°C ±2°C
50 to 248°F 2°F ±4°F
Part numbers ending with “H” are provided with a molded eye (hook)
for easy mounting. Models HI 140H & HI 140 HH are provided with
an external probe with 1.5 m (5’) cable.
HI 140 HI 90140
EXTERNAL DIAMETER 86.5 mm (3.4”) 159 mm (6.3”)
HEIGHT 35 mm (1.4”) 47.5 mm (1.9”)
WEIGHT 150 g (5.54 oz.) 150 g (5.54 oz.)
START UP
In order to communicate with the
HI 140 thermologger, the HI 92140
application software must be installed
on your PC.
Connect the HI 90140 infrared transmitter to your computer through an
RS232 port.
Place the HI 140 on the transmitter
as shown in the picture.
Run the HI 92140 software and
refer to the on-line help for any
further information about setting the
parameters of the logger, acquire
logged data, etc.
BATTERY REPLACEMENNT
Battery replacement must only take place in a non hazardous area using the appropriate battery type (1.5V AA).
When the batteries need to be
replaced, simply remove the screws
on the rear cover of the logger
and replace the three batteries
with new ones, while paying attention to the correct polarity.
After replacing the batteries, press the reset button on the
printed circuit board. The red LED blinks and then the
green LED stays on.
Reattach the cover and tighten the screws.
Note: Each time the batteries are replaced, all logger
parameters have to be set again by the user as soon
as possible to avoid draining the batteries.
CE DECLARATION OF CONFORMITY
Recommendations for users
Before using these products, make sure
that they are entirely suitable for the environment in which they are used.
Operation of these instruments in residential areas could cause unacceptable
interferences to radio and TV equipments,
requiring the operator to take all necessary steps to correct interferences.
Any variation introduced by the user to
the supplied equipment may degrade the
instruments’ EMC performance.
To avoid damages or burns, do not perform any measurement in microwave
ovens.
WARRANTY
HI 140 loggers are warranted for one year against defects in workmanship and materials
when used for their intended purpose and maintained according to instructions. This warranty
is limited to repair or replacement free of charge. Damages due to accident, misuse,
tampering or lack of prescribed maintenance are not covered. If service is required, contact
the dealer from whom you purchased the instrument. If under warranty, report the model
number, date of purchase, serial number and the nature of the failure. If the repair is not
covered by the warranty, you will be notified of the charges incurred. If the instrument is to
be returned to Hanna Instruments, first obtain a Returned Goods Authorization Number
from the Customer Service department and then send it with shipment costs prepaid. When
shipping any instrument, make sure it is properly packaged for complete protection.
Hanna Instruments reserves the right to modify the design, construction and
appearance of its products without advance notice.
IST140R3 05/05