Installation Manual of Room Air Conditioner

Read this manual before installation

Explain sufficiently the operating means to the user according to this manual.

Necessary Tools for Installation

1.Driver

5.Torque wrench(17mm,22mm,26mm)

9.Nipper

12.Reamer

2.Hacksaw

6.Pipe cutter

10.Gas leakage detector or

 

3.Hole core drill

7.Flaring tool

soap-and-water solution

 

4.Spanner(17,19 and 26mm)

8.Knife

11.Measuring tape

 

Accessory parts

Number

No. Accessory parts of

articles

1

Remote controller

1

2

 

R-03 dry battery

2

3

 

 

 

1

 

 

 

Mounting plate

 

4

 

 

Drain hose

1

 

 

 

 

5

4X25

Plastic cap

4

 

Screw

 

 

 

 

 

 

6

 

 

Drain-elbow

1

7

 

 

Cushion

4

8

Pipe supporting plate

1

 

 

 

Drawing for the installation of indoor and outdoor units

The models adopt HFC free refrigerant R410A

more than 5cm

Optional parts for piping

Mark

Parts name

more

than

10cm

A

Non-adhesive tape

 

 

 

 

 

 

B

Adhesive tape

 

 

 

C

Saddle(L.S) with screws

 

 

 

D

Connecting electric cable

 

 

 

for indoor and outdoor

 

 

 

 

 

 

 

E

Drain hose

 

 

 

F

Heating insulating material

 

 

 

G

Piping hole cover

 

 

 

Arrangement of piping directions

 

Rear left

Left

Rear

 

right

 

Right

 

Below

more

than

10cm

 

 

 

A

Attention must be paid to the rising up of drain hose

 

than

10cm

more

 

 

 

more

than

 

 

 

10cm

D

 

 

 

 

 

more

than

15cm

 

 

 

 

than

60cm

more

 

 

 

The marks from A to G in the figure are the parts numbers.

The distance between the indoor unit and the floor should be more than 2m.

No.0010557190

Floor fixing dimensions of the outdoor unit (Unit:mm)

HSU-09H03/R2(DB)

HSU-12H03/R2(DB) HSU-09HA103/R2(DB)

HSU-12HB03/R2(DB) HSU-12HA103/R2(DB) HSU-18H03/R2(DB) HSU-18HA103/R2(DB)

319.5

113.5

583

113.5

Floor fixing dimensions of the outdoor unit (Unit:mm)

HSU-22H03/R2(DB) HSU-22HA103/R2(DB)

Fixing of outdoor unit

Fix the unit to concrete or block with bolts(10mm) and nuts firmly and horizontally. When fitting the unit to wall surface, roof or rooftop, fix a supporter surely with nails or wires in consideration of earthquake and strong wind.

If vibration may affect the house, fix the unit by attaching a vibration-proof mat.

Indoor Unit

Selection of Installation Place Outdoor Unit

Place, robust not causing vibration, where the body can be supported sufficiently.

Place, not affected by heat or steam generated in the vicinity, where inlet and outlet of the unit are not disturbed.

Place, possible to drain easily, where piping can be connected with the outdoor unit.

Place, where cold air can be spread in a room entirely.

Place, nearby a power receptacle, with enough space around. (Refer to drawings).

Place where the distance of more than lm from televisions, radios, wireless apparatuses and fluorescent lamps can be left.

In the case of fixing the remote controller on a wall, place where the indoor unit can receive signals when the fluorescent lamps in the room are lightened.

Place, which is less affected by rain or direct sunlight and is sufficiently ventilated.

Place, possible to bear the unit, where vibration and noise are not increased.

Place, where discharged wind and noise do not cause a nuisance to the neighbors.

Place, where a distance marked is available as illustrated in the above figure.

Power Source

Before inserting power plug into receptacle, check the voltage without fail. The power source is the same as the corresponding name plate.

Install an exclusive branch circuit of the power.

A receptacle shall be set up in a distance where the power cable can be reached. Do not extend the cable by cutting it.

Selection of pipe

To this unit, both liquid and gas pipes shall be insulated

 

 

 

 

HSU-09H03/R2(DB) HSU-12HB03/R2(DB)

HSU-12H03/R2(DB)

as they become low temperature in operation.

 

 

HSU-09HA103/R2(DB)

HSU-18H03/R2(DB) HSU-18HA103/R2(DB)

Use optional parts for piping set or pipes covered with

 

HSU-12HA103/R2(DB)

HSU-22H03/R2(DB) HSU-22HA103/R2(DB)

 

 

 

 

 

Liquid pipe

6.35mm(1/4")

6.35mm(1/4")

equivalent insulation material.

 

 

 

 

The thickness of the pipe must be 0.8mm at least.

Gas pipe

9.52mm(3/8")

12.7mm(1/2")

 

 

 

 

 

2

Indoor unit

1.Fitting of the Mounting Plate and Positioning of the wall Hole

When the mounting plate is first fixed

1.Carry out, based on the neighboring pillars or lintels, a proper leveling for the plate to be fixed against the wall, then temporarily fasten the plate with one steel nail.

2.Make sure once more the proper level of the plate, by hanging a thread with a weight from the central top of the plate, then fasten securely the plate with the attachment steel nail.

3.Find the wall hole location A using a measuring tape

B=

60mm

 

A=145mm

30mm

 

 

When the mounting plate is fixed side bar and lintel

Fix to side bar and lintel a mounting bar, Which is separately sold, and then fasten the plate to the fixed mounting bar.

Refer to the previous article, " When the mounting plate is first fixed ", for the position of wall hole.

2.Making a Hole on the Wall and Fitting the Piping Hole Cover

Make a hole of 60 mm in diameter, slightly descending to outside the wall. Install piping hole cover and seal it

off with putty after installation

Indoor side

Outdoor side

Wall hole

Thickness

60mm

of wall

 

(Section of wall hole) Piping hole pipe

3