Haier HSU-09H13, HSU-12H13 Manual

0 (0)

SPLIT TYPE ROOM AIR CONDITIONER

OPERATION MANUAL

HSU-09H13

HSU-12H13

Please read this operation manual before using the air conditioner.

No.0010501517

Caution

Disposal of the old air conditioner

Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment.

It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The valuable materials contained in an air conditioner can be recycled. Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that

the pipework of your air conditioner does not get damagedprior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, anti-pollution method of disposal.

All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.

Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house.

Safety Instructions and Warnings

Before starting the air conditioner, read the information given in the User's Guide carefully. The User's Guide contains very important observations relating to the assembly, operation and maintenance of the air conditioner.

The manufacturer does not accept responsibility for any damages that may arise due to non-observation of the following instruction.

Disposal of the packaging of your new air conditioner

All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment.

The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of

polyethylene and the polyethylene foam pads contain no fluorochloric hydrocarbon.

Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier.

Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.

Installation shall be done by professional people, don't install unit by yourself.

1

Caution

For the purpose of the safety,the air conditioner must be properly grounded in accordance with specifications.

Always remember to unplug the air conditioner before openning inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.

All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditioner.

Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts

out and gets into eyes, it may result in serious eye injuries.

Do not obstruct or cover the ventilation grille of the air conditoner.Do not put fingers or any other things into the inlet/outlet and swing louver.

Do not allow children to play with the air conditioner.In no case should children be allowed to sit on the outdoor unit.

Specifications

The refrigerating circuit is leak-proof.

Remark per EMC Directive 89/336/EEC. To prevent flicker impression during the start of the compressor(Technical Process)

and the adversely influence caused by

the 2nd harmonies of compressor following installation conditions do apply:

1.The power connection for air conditioner has to be done at the main power distribution.This distribution has to be of a Iow impedance. Normally the required impedance is reached at a 32A fusing point. 2.No other equipment has to be connected: to this power line.

3.For the details installation acceptance please refer to your contract with the power supplier, if restrictions do apply for products: like washing machines,air conditioners or electrical ovens.

4.For the details of the power of air, conditioner, please refer to the rating plate of the product.

5.For any question contact your local dealer.

2

Caution

The machine is adaptive in following situation

1.Applicable ambient temperature range:

 

Indoor

Maximum: D.B / W.B

32oC/23oC

 

Minimum: D.B / W.B

18oC/14oC

Cooling

 

Outdoor

Maximum: D.B

43oC/26oC

 

 

Minimum: D.B

18oC

 

 

 

Indoor

Maximum: D.B

27oC

Heating

Minimum: D.B

15oC

Outdoor

Maximum: D.B / W.B

24oC/18oC

 

Minimum: D.B / W.B

-7oC/-8oC

2.If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05RN-F or H07RN-F

3.If the fuse on PC board is broken please change it with the type of T. 3.15A/250V.

4.The distance between the indoor unit and the floor should be more than 2m.

5.The wiring method should be in line with the local wiring standard.

6.After installation, the power plug should be easily reached.

7.The waste battery should be disposed properly.

8.The appliance is not intended to use by young children or infirm persons without supervision. 9.Young children should be supervised ensure that they do not play with the appliance.

10.The appliance must be installed on strong enough supporter.

11.The wiring diagram is attached inside the machine.

3

Haier HSU-09H13, HSU-12H13 Manual

Parts and Functions

Indoor Unit

Inlet grille

Air filter

Test running switch(manual)

Used only for test running in cooling when room temp. is below 16oC. Don't use it in normal operation.

Emergency switch(manual)

Used when remote controller is lost or defective. Unit will run temporarily.

Remote signal receiver

A beeping sound is generated when a signal from remote controller is received.

Vertical flap

Use remote controller to adjust up and down air flow. (Don't adjust it manually.)

Power indicator

Timer mode indicator

Lights up when unit starts.

Lights up when Timer operation

 

is selected.

Operation mode indicator

Lights up during compressor running.

Actual inlet grille may vary from the one shown in the manual according to the product purchased

Outdoor Unit

HSU-09H13

HSU-12H13

OUTLET

CONNECTING PIPING AND ELECTRICAL WIRING

INLET

DRAIN HOSE

4

Parts and Functions

Operation Buttons and display of the remote controller.

1

5

 

2

6

7

3

8

 

4

9

10

ON/OFF

TEMP

11

18

MODE

SET

12

19

FAN

TIMER

13

20

14

CLOCK

SWING

15

21

SLEEP

 

16

 

LOCK

RESET

17

22

1.Mode display

AUTO COOL

DRY

 

HEAT

 

FAN

2.

SWING display

3.

FAN SPEED display AUTO LO MED HI

4.SLEEP display

5.LOCK display

6.SIGNAL SENDING

7.TIMER OFFdisplay

8.TIMER ON display

9.CLOCK display

10.TEMP display

11.POWER ON/OFF

Used for unit start and stop.

12.MODE

Used to select AUTO run, COOL, DRY, HEAT and FAN operation

13.FAN

Used to select fan speed LO, MED, HI, AUTO

14.HOUR

Used to set clock and timer setting.

15.SWING

Used to set auto fan direction.

16.SLEEP

Used to select sleep mode.

17.LOCK

Used to lock buttons and LCD display.

18.TEMP.

Used to select your desired temp.

19.SET

Used to confirm timer and clock settings.

20.TIMER

Clock set

Used to select TIMER ON, TIMER OFF, TIMER ON-OFF

21.CLOCK

Used to set correct time

22.RESET

Used to reset the controller back to normal condition.

When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows:

Press CLOCK button, "AM" or "PM" flashes.

Pressorto set correct time. Each press will increase or decrease 1min. If the button is kept depressed, time will change quickly.

After time setting is confirmed, press SET, "AM "and "PM" stop flashing, while clock starts working.

NOTE: Cooling only unit do not have displays and functions related with heating

Hints

After replacing with new batteries, remote controller will conduct self-check, displaying all information on LCD. Then, it will become normal.