HAIER AMERICA
Part Number : AC-8888-148
SERVICEMANUAL
AIRCONDITIONER
HPR10XC6
Importantpointsonservice,andflowchartfor
inspectingandrepairingtheunit.........................1
Appearance(outward)........................................2
Troubleshooting..................................................3
Operation...............4
Remotecontrol
Technicalspecifications.................................6
Refrigeratorsystemdiagramandschematicwiring
diagram...........................................................7
Explodedview....................................................8
Partslist.......................................................9-11
Thismanualisfortheuseoftechnicalpersonnelentrusted
withmaintenance.
Widetechreservestherighttochangethisdehumidifier's
casing,circuitandpartswithoutnotice.
Date:2006/06/15 Version:1.0
.............................................
....................................................5
.....
...
.
115V/60Hz
IMPORTANTPOINTSONSERVICEOPERATINGSAFETY
Pleasefollowtheseinstructionscarefully:
Unplugtheunittoavoidanydangerfromelectricshockbeforedisassemblingtheunitfor
repair.
Ifthereisanysoundoftherefrigerantcirculatingwheninoperation,avoidtouchingthe
coolingcoils.
Ifyouneedtoperformanyweldingorsoldering,besureyouareinawellventilatedarea.
Onlyaqualifiedprofessionalshouldperformanyweldingontheunit.
Whenrepairingtheunit,thespecificationslistedinthismanualmustbestrictlyadhered
towhenreplacinganycomponents.
Whenreplacinganyelectricalcomponentstheyshouldbefactoryapprovedunits.
Besurethatanyelectricalcomponentsareproperlywiredandinplace.
FLOWCHARTFORINSPECTINGANDREPAIRINGTHEUNIT
AIRCONDITIONER
WON'TSTART
AIRCONDITIONER
WON'TCOOL
PROPERLY
NOPOWER
COMPRESSORWON'T
START
POWERTRIPPED
PLUGANDSOCKET
ARELOOSE
TIMERFAILURE
PROTECTORFAILURE
CAPACITORFAILURE
WIRINGISLOOSE
CHECKTHEPOWER
SWITCH
RE-PLUGINGTHE
POWERSUPPLYCORD
TESTINGBY
ELECTROSCOPE
CHANGETHE
PROTECTOR
CHANGETHE
CAPACITOR
RE-CONNECTING
CHANGETHESWITCH
REFRIGERANT
LEAKAGE
USEOXYACETYLENEANDPLUS5%
SILVERSOLDERTOWELDTHE
CRACKEDPOINTS
RUNNINGTEST
TROUBLESHOOTING
THESYSTEM
RUNNINGTHEVACUUM
EVACUATIONFORMORE
THAN15MINUTES
-1-
CHANGE THEAIRCONDITIONERWITH15KG/CM
NITROGENGASFROMLOW-PRESSURESIDEAND
DETECTTHELEAKINGPOINTBYSOAP
CHANGECOOLANTAND
PROCEEDRUNNINGTEST
2