Groen HY-6SE w/TDC/3-20 General Manual

HyPerSteam Pressureless Steamer
Description
Steamer shall be a Groen HyPLUS™ Model HY-6SEw/ TDC/3-20, stainless steel twin cavity, 6 pan pressureless steamer, with 20 quart tilting steam jacketed kettle, and cabinet mounted (specify 24, 36 or 48) electric steam boiler, per Bulletin 78Aa and as follows:
Construction
Steamer cavities and cabinet base shall be all stainless steel construction. Steamer unit shall have a unitized body with removable right side panel providing access to internal component. Steamer doors are all stainless steel with strong continuous hinge, are field reversible and provided with a one piece, replaceable seal. Hidden magnetic door switch cuts power to blower and steam flow to that cavity, when the door is opened. Pan support racks shall be polished stainless steel and removable for easy cleaning. Wide drip sink with condensate drain is positioned under cavity doors.
Kettle shall have one piece welded construction of Type 304 stainless steel, with reinforced rim and butterfly shaped pouring lip. Kettle support legs shall be heavy tubular stainless steel. Flush mounted pouring sink with splash shield standard.
36” wide cabinet base shall have stainless steel frame with all stainless steel top deck, removable front access doors, with side and rear panels standard. Front and rear legs shall have adjustable bullet feet. Flanged feet are an available option.
Finish
Cabinet exterior, including door, shall be finished to a #3 uniform finish. Cavity interiors are electro polished stain­less steel. Kettle exterior shall be polished to a bright high buff finish.
ASME Code & UL Approval
Cabinet mounted boiler shall be ASME Code constructed and National Board Registered for operation up to 15 PSI. Steamer unit and cabinet mounted boiler shall be UL listed.
Sanitation
Unit shall be designed and manufactured to meet NSF known health department and sanitation codes and be NSF listed.
Controls
Steamer cavity controls shall be mounted on the front panel for easy replacement or repair and will include a separate ON-OFF/60 minute timer control with constant steam setting, for each cavity. Kettle steam control valve and HOT/COLD water faucet handles will be front mounted with boiler controls. Electric boiler shall be provided with a gas control valve, power-ON switch, RESET light, start switch, low water sensor, pop safety valve, water level sight glass and outside cabinet mounted pressure gauge.
Performance Features
Unit will shut off if water level is low or unit builds too much pressure. When power switch is turned “off,” the boiler automatically drains to reduce sediment build-up, after water has cooled to 70ºF.
Each steamer cavity shall have a powerful side mounted blower, which increases steam velocity and provides effi­cient steam distribution throughout cavity and between
loaded pans.
Cabinet Base Steam Source
Unit shall have twin electric-heated, cabinet-mounted pressure boiler to provide atmospheric steam to each chamber at a temperature of approximately 212ºF and steam to kettle at approximately 12 PSI. The 24KW model delivers 2.2 boiler horsepower, the 36 KW model delivers
3.5 boiler horsepower and the 48 KW model delivers 4.7 boiler horsepower.
Hot & Cold Water Faucet
Unit shall be provided with hot and cold water faucet with swing spout standard.
Pan Capacity
Pan Size Per Cavity Total
12 x 20 x 1” 6 12
12 x 20 x 2 1/2” 3 6
12 x 20 x 4” 2 4
Options/Accessories
Independent cold water to condensate spray Cover and-or basket insert for kettle
Installation
Specify 208, 240 or 480 Volt, 3 phase, 60 cycle electrical service. Unit requires 1/2” NPT cold water supply line, 3/8” NPT hot water supply line for faucet and 11/4” NPT free venting drain.
Steam Source for Adjacent Equipment
A 1/2” NPT power take-off valve shall be standard. To ensure proper performance, boiler must be sized to meet boiler horsepower requirements of steamer cavities, 20 quart kettle AND additional equipment. Appropriate steam traps and piping must be installed for that additional equipment.
Water Supply Requirements
All water boiler systems are subject to contamination and failure due to mineral content found in most water supplies. To minimize service problems, a water treatment (soften­ing) system is recommended when water quality is found to exceed limits stated on other side and in operator manual.
Origin of Manufacture
Steamer/Kettle Combination shall be designed and manu­factured in the United States.
model HY-6SE w/TDC/3-20
6-Pan Capacity Stainless Steel Pressureless Steamer/ Kettle Combination
With Electric Pressure Boiler in Cabinet Base
Short Form
Unit shall be a Groen HyPLUS™ pressureless steamer Model HY-6SE w/TDC/3-20, with 20 quart tilting kettle powered by electric pressure boiler mounted in 36” wide cabinet base, per Bulletin 78Aa. All stainless steel construction with two independent steamer chambers, each with powerful blower to circulate steam within cavity and individual 60 minute timer with constant steam setting. Steamer doors are insulated, field reversible, with easy open latch and hidden magnetic door switch. Drip sink with condensate drain is provided under cavity doors. Three (21/2” deep) pan capacity per chamber. Cabinet base has stainless steel frame, all stainless steel exterior, with removable front access doors and adjustable bullet feet. Pouring sink and HOT/COLD water faucet provided for kettle. Boiler ASME code constructed for 15 PSI maximum, with choice of 24, 36, or 48KW power input. Power take-off to divert steam to adjacent equipment is standard. UL listed, unit comes standard with automatic boiler drain. See other side for water, drain and electric connections required. Made in USA.
Applications
Pasta Rice Vegetables (Fresh & Frozen) Seafood (Fresh & Frozen) Poultry Potatoes Eggs Meats Reheat Cook-Chill & Prepared Foods
1055 Mendell Davis Drive, Jackson, MS 39272 888-994-7636, unifiedbrands.net
Please reference our website for the most updated product information and specifications.
Groen HyPerSteam, Page 14
160179C
Revised 08/09
7
(192)
Model HY-6SE w/TDC/3-20
P/N 121505 REV G
1
21
4
(540)
1
18
2
(470)
9
16
1
2
4
3
6
CONDENSATE DRAIN VENT
SINK
DRAIN
5
1
8
2
(216)
CLEARANCE SEE NOTE 1
(102)
4
(508)
20
5
57
(1453)
9
26
16
(675)
1
(38) MIN.
1
2
5
(67) MAX.
2
8
4
(117)
TM
READY ON
WATER FILL
LOW WATER
HIGH PRESSURE
5 8
36
(918)
A
E
M
T
S
1 8
SERVICE CONNECTIONS:
DRAIN CONNECTION: 1-1/4" NPT
1
(INCLUDES AUTOMATIC & MANUAL BOILER, STEAMERS, CONDENSATE SPRAY, KETTLE & SINK)
2
COLD WATER SUPPLY: 1/2" NPT (FOR BOILER, CONDENSATE SPRAY & FAUCET)
3
OPTION: SEPARATE CONDENSATE SPRAY 3/8" NPT (ADD KIT #MS102210)
4
HOT WATER SUPPLY: 3/8" NPT (FOR FAUCET)
MAIN ELECTRICAL CONNECTION (ALL UNITS): 1-31/32" DIA. HOLE
5
(REF. 1-1/2" CONDUIT KNOCK-OUT)
STEAM POWER TAKE-OFF: 1/2" NPT
6
NOTES:
1. DIMENSIONS IN BRACKETS ( ) ARE MILLIMETERS.
MAXIMUM
HEATER ELEMENT CURRENT
*
208V 240V 480V
1
UN-TREATED
(OPTIONAL)
DETAIL VIEW
29A58A67A
58A116A134A
4
3
2
23
(586)
2
(51)
WATER SUPPLY CONN.
121505 REV. G
6
1
16
5
24
16
(618)
24KW
36KW
100A 87A 44A
48KW
* AMPS (EACH LINE), 3 PHASE
3
16
5
3
8
8
(213)
ADJUSTABLE
BULLET FEET
34
(868)
3
16
OF WATER CONNECTIONS
(IF SECOND CONNECTION ORDERED)
TREATED WATER SUPPLY CONN.
1055 Mendell Davis Drive, Jackson, MS 39272, 888-994-7636, unifiedbrands.net
© 2009 Unified Brands. All Rights Reserved. DOVER® and the DOVER® Logo are registered trademarks in the United States [and various other countries] of Unified Brands, a wholly-owned subsidiary of Dover Corporation.
Loading...