Groen HY-5E(CE) Operation Manual

IMPORTANT INFORMATION - KEEP FOR OPERATOR - IMPORTANT INFORMATIONIMPORTANT INFORMATION - KEEP FOR OPERATOR - IMPORTANT INFORMATION
OPERATOR AND SERVICE MANUAL OM/SM-HY-3E(CE)
Part Number 128174 OM/SM-HY-5E(CE)
INTERNATIONAL
MODELS: HY-3E(CE), HY-5E(CE)
HyPerSteam™ Atmospheric Convection Steamer - CE
(12" x 20" x 2½”)
(305 mm x 508 mm x 64 mm)
HY-3E(CE)
HY-5E(CE)
KEEP THIS MANUAL WITH STEAMER DOCUMENTS. OPERATORS AND TECHNICIANS SHOULD READ, UNDERSTAND AND FOLLOW INSTRUCTIONS AND WARNINGS CONTAINED IN THIS MANUAL.
Information contained in this document is known to be current and accurate at the time of printing/creation. Unified Brands recom­mends referencing our product line websites, unifiedbrands.net, for the most updated product information and specifications.
OM/SM-HY-3E & HY-5E(CE)
IMPORTANT — READ FIRST — IMPORTANT
THESE APPLIANCES MUST BE INSTALLED BY A COMPETENT PERSON IN CONFORMITY WITH THE INSTALLATION AND SERVICING INSTRUCTIONS AND NATIONAL REGULATIONS IN FORCE AT THE TIME. PARTICULAR ATTENTION MUST BE PAID TO THE FOLLOWING:
I. E. E. REGULATIONS FOR ELECTRICAL INSTALLATIONS ELECTRICITY AT WORK REGULATIONS HEALTH AND SAFETY AT WORK ACT FIRE PRECAUTIONS ACT LOCAL AND NATIONAL BUILDING REGULATIONS
USERS SHOULD BE CONVERSANT WITH THE APPROPRIATE PROVISIONS OF THE FIRE PRECAUTIONS ACT. IN PARTICULAR THEY SHOULD BE AWARE OF THE NEED FOR REGULAR SERVICING BY A COMPETENT PERSON TO ENSURE THE CONTINUED SAFE AND EFFICIENT PERFORMANCE OF THE APPLIANCE.
WARNING: TO PREVENT SHOCKS, ALL APPLIANCES WHETHER GAS OR ELECTRIC, MUST BE
EARTHED.
UPON COMPLETION OF THE INSTALLATION, THE OWNERS MANUAL SHOULD BE HANDED TO THE USERS AND THE INSTALLER SHOULD INSTRUCT THE RESPONSIBLE PERSON(S) IN THE CORRECT OPERATION AND MAINTENANCE OF THE APPLIANCE.
THIS EQUIPMENT IS ONLY FOR PROFESSIONAL USE, AND SHALL BE OPERATED BY QUALIFIED PERSONS. IT IS THE RESPONSIBILITY OF THE SUPERVISOR OR EQUIVALET TO ENSURE THAT USERS WEAR SUITABLE PROTECTIVE CLOTHING AND TO DRAW ATTENTION TO THE FACT THAT, SOME PARTS WILL, BY NECESSITY, BECOME VERY HOT AND WILL CAUSE BURNS IF TOUCHED ACCIDENTALLY.
UNLESS OTHERWISE STATED, PARTS WHICH HAVE BEEN PROTECTED BY THE MANUFACTURER ARE NOT TO BE ADJUSTED BY THE INSTALLER.
WARNING: AVOID ANY EXPOSURE TO THE STEAM COMING OUT WHEN OPENING THE DOOR.
BEFORE ATTEMPTING ANY SERVICING, ENSURE THAT THE ELECTRICAL SUPPLY IS DISCONNECTED.
WARNING: THE UNIT MUST BE INSTALLED BY PERSONNEL QUALIFIED TO WORK WITH
ELECTRICITY AND PLUMBING. IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO THE EQUIPMENT. THE UNIT MUST BE INSTALLED IN ACCORDANCE WITH APPLICABLE CODES.
CAUTION: SHIPPING STRAPS ARE UNDER TENSION AND CAN SNAP BACK WHEN CUT.
CAUTION: DO NOT INSTALL THE UNIT IN ANY WAY WHICH WILL BLOCK THE RIGHT SIDE VENTS, OR
WITHIN 12 INCHES OF A HEAT SOURCE SUCH AS A BRAISING PAN, DEEP FRYER, CHAR­BROILER OR KETTLE.
CAUTION: LEVEL THE UNIT FRONT TO BACK, OR PITCH IT SLIGHTLY TO THE REAR, TO AVOID
DRAINAGE PROBLEMS.
WARNING: TO AVOID DAMAGE OR INJURY, FOLLOW THE WIRING DIAGRAM EXACTLY WHEN
CONNECTING A UNIT.
CAUTION: DO NOT USE PLASTIC PIPE. DRAIN MUST BE RATED FOR BOILING WATER.
WARNING: DO NOT CONNECT THE DRAIN DIRECTLY TO A BUILDING DRAIN.
2
OM/SM-HY-3E & HY-5E(CE)
WARNING: BLOCKING THE DRAIN IS HAZARDOUS.
IMPORTANT: Improper drain connection will void warranty.
IMPORTANT: Do not allow any water traps in the line. A trap can cause pressure to build up inside the
cavity during steaming, which will make the door gasket leak.
WARNING: WHEN YOU OPEN THE DOOR, STAY AWAY FROM STEAM COMING OUT OF THE UNIT.
STEAM CAN CAUSE BURNS.
WARNING: BEFORE CLEANING THE OUTSIDE OF THE STEAMER, DISCONNECT THE ELECTRIC
POWER SUPPLY. KEEP WATER AND CLEANING SOLUTIONS OUT OF CONTROLS AND ELECTRICAL COMPONENTS. NEVER HOSE OR STEAM CLEAN ANY PART OF THE UNIT.
WARNING: ALLOW COOKING CHAMBER TO COOL BEFORE CLEANING.
WARNING: CAREFULLY READ THE WARNINGS AND FOLLOW THE DIRECTIONS ON THE LABEL OF
EACH CLEANING AGENT. USE SAFETY GLASSES AND RUBBER GLOVES AS RECOMMENDED BY DE-LIMING AGENT MANUFACTURER.
WARNING: DO NOT MIX DE-LIMING AGENTS (ACID) AND DE-GREASERS (ALKALI).
WARNING: DO NOT PUT HANDS OR TOOLS INTO THE COOKING CHAMBER UNTIL THE FAN HAS
STOPPED TURNING.
WARNING: DO NOT OPERATE THE UNIT UNLESS THE REMOVABLE LEFT AND RIGHT SIDE PANELS
HAVE BEEN RETURNED TO THEIR PROPER LOCATIONS.
NOTICE: DO NOT USE A CLEANING OR DE-LIMING AGENT THAT CONTAINS ANY SULFAMIC ACID
OR ANY CHLORIDE, INCLUDING HYDROCHLORIC ACID. IF THE CHLORIDE CONTENT OF ANY PRODUCT IS UNCLEAR, CONSULT THE MANUFACTURER.
NOTICE: DO NOT USE ANY DE-GREASER THAT CONTAINS POTASSIUM HYDROXIDE OR SODIUM
HYDROXIDE OR THAT IS ALKALINE.
WARNING: USE OF ANY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY GROEN OR
THEIR AUTHORIZED DISTRIBUTOR VOIDS ALL WARRANTIES AND CAN RESULT IN BODILY INJURY TO THE OPERATOR AND DAMAGE THE EQUIPMENT. SERVICE BY OTHER THAN FACTORY-AUTHORIZED PERSONNEL WILL VOID ALL WARRANTIES.
WARNING: HIGH VOLTAGE EXISTS INSIDE CONTROL COMPARTMENTS. DISCONNECT FROM
BRANCH BEFORE SERVICING. FAILURE TO DO SO CAN RESULT IN SERIOUS INJURY OR DEATH.
3
OM/SM-HY-3E & HY-5E(CE)
Table of Contents
OPERATOR WARNINGS .....................................................2
REFERENCES .............................................................3
EQUIPMENT DESCRIPTION ..................................................4
INSPECTION AND UNPACKING ...............................................4
WATER CONDITIONING/REQUIREMENTS ......................................4
INSTALLATION AND START-UP INSTRUCTIONS .................................6
OPERATING INSTRUCTIONS ................................................10
CLEANING ...............................................................12
MAINTENANCE AND TROUBLESHOOTING ....................................14
PARTS LIST ..............................................................15
SCHEMATICS HY-3E .......................................................21
SCHEMATICS HY-5E .......................................................22
SERVICE PROCEDURES ...................................................23
SERVICE LOG ............................................................33
WARRANTY PROTECTION .................................................34
References
UNDERWRITERS LABORATORIES, INC. 333 Pfingsten Road Northbrook, Illinois 60062
KLENZADE SALES CENTER ECOLAB, Inc. 370 Wabasha St. Paul, Minnesota 55102 800 328-3663 or 612 293-2233
NATIONAL FIRE PROTECTION ASSOCIATION 60 Battery March Park Quincy, Massachusetts 02269
NFPA/70 The National Electrical Code
NATIONAL SANITATION FOUNDATION 3475 Plymouth Road Ann Arbor, Michigan 48106
4
Equipment Description
Your Groen HY-3E and HY-5E HyPerSteam Convection Steamers are designed to give years of service. It has a stainless steel cavity (cooking chamber) which is served by an independent atmospheric steam generator which is electrically­heated. A powerful blower circulates the steam in the cavity to increase heating efficiency.
The cavity holds up to three (HY-3E) or five (HY-5E) standard steam table pans. A 1.5 mm thick stainless steel case encloses the cavity, the steam generator and the control compartment that houses electrical components. Door hinges are reversible (the door may be set to open from the left or right). Operating Controls are on the front panel.
Newer model HY-3E steamers and all HY-5E steamers, are equipped with fully electronic controls and a button-activated, pre-programmed CLEAN cycle. These units are readily identified by their unique control panels, with touch pad controls, and the distinctive symbol for steam is integrated into the panel.
OM/SM-HY-3E & HY-5E(CE)
The HY-5E steamer holds five standard 305 mm x 508 mm x 64 mm deep pans.
Both units are distinguished by the addition of a “fuse box” which allows the operator to change fuses without removing panels.
The drain system on all models includes a spray condenser, which helps keep steam from escaping from the chamber and cools drain water.
Inspection and Unpacking
The HY-3E or HY- 5E will be delivered completely assembled in a heavy shipping carton attached to a skid. On receipt, inspect the carton carefully for exterior damage.
CAUTION SHIPPING STRAPS ARE UNDER TENSION AND CAN SNAP BACK WHEN CUT.
Carefully cut the straps around the carton and detach the sides of the carton from the skid. Pull the carton up off the unit. Be careful to avoid personal injury or equipment damage from staples which might be left in the carton walls.
The HY-3E steamer holds three standard 305 mm x 508 mm x 64 mm deep pans.
CAUTION THIS UNIT WEIGHS 82 KG (HY-3E) OR 105 KG (HY-5E). YOU SHOULD GET HELP AS NEEDED TO LIFT THIS WEIGHT SAFELY.
Write down the model number, serial number and installation date. Keep this information for reference. Space for these entries is provided at the top of the Service Log in the back of this manual.
When starting installation, lift the unit straight up off the skid. Check packing materials to make sure loose parts such as the condensate drip tray are not discarded with this material.
5
OM/SM-HY-3E & HY-5E(CE)
Water Conditioning
It is essential to supply the steam generator with water that will not form scale. Even though the steam generator is engineered to minimize scale formation, scale development depends on the hardness of your water and the number of hours per day you operate the equipment.
In some areas, water is low enough in mineral content to avoid scale formation. But most water supplies are full of minerals which form scale. It is this scale which could lead to an early component failure.
Your water utility can tell you about the minerals in your water. The water going to the steam generator should have between 10 and 30 parts per million (ppm) total dissolved solids (TDS) and should have a pH (acidity rating) of 7.0 or higher. Please follow these simple precautions:
1. Do not rely on unproven water treatments which are sold for scale prevention or scale removal. They don’t always work. The best way to prevent scale is to supply the purest possible water (10 - 20 ppm TDS).
2. If your water contains scale-forming minerals, as most water does, use a well-maintained water softener. Whether an exchangeable softener cartridge or a regenerating system is chosen, a regular exchange schedule is essential.
3. Installing a water meter between the softener and the steamer will provide an accurate gauge of water use, and will help determine when to exchange cartridges or regenerate the softener. Using a water softener will provide longer generator life, higher steam capacity, and reduce maintenance requirements.
4. If you notice a slowdown in steam production, have the unit checked for scale build-up. Heavy scale reduces the unit’s ability to boil water, and can even cause heating elements in the steam generator to overheat and burn out.
MINIMIZE SCALE PROBLEMS, BY USING AND MAINTAINING A SOFTENER, AND BY CLEANING THE STEAMER REGULARLY.
A BSPT connection is provided at the rear of the steamer.
6
OM/SM-HY-3E & HY-5E(CE)
Installation and Start-Up
WARNING THE UNIT MUST BE INSTALLED BY PERSONNEL WHO ARE QUALIFIED TO WORK WITH ELECTRICITY AND PLUMBING. IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO
THE EQUIPMENT. THE UNIT MUST BE INSTALLED IN ACCORDANCE WITH APPLICABLE CODES.
CAUTION DO NOT INSTALL THE UNIT WITH THE RIGHT OR LEFT SIDE VENTS BLOCKED OR WITHIN 12 INCHES OF A HEAT SOURCE (SUCH AS A BRAISING PAN, DEEP FRYER, CHAR BROILER OR KETTLE). TO AVOID DRAINAGE PROBLEMS, LEVEL THE UNIT FRONT TO BACK.
1. Electrical Supply Connection
A. Panel Removal
Open the wiring and control panel by removing two screws (three on new model) on the right side panel. Slide the panel forward, and set it aside.
B. Supply Voltage
The unit must be operated at the rated nameplate voltage, plus or minus 10 percent.
C. Phase Selection
Refer to heater schematics (Pages 17 thru 20) for wiring information.
CAUTION THE UNIT MUST HAVE A SEPARATE GROUND WIRE FOR SAFE OPERATION.
D. Terminal Block
The terminal block for incoming power is located at the back of the control compartment. The ground terminal is located in the wiring
compartment near the terminal block. Minimum size for the ground wire is 10 AWG.
E. Supply wire
To determine the type of wire you need for the power supply, find the operating voltage and phase on the unit data plate. Refer to the table below for correct wire size and temperature rating. The “Electrical Supply Connection” label on back right side of the unit gives directions for proper connection of the terminal block jumpers. The specified wire must be used, or the unit will not meet Underwriters Laboratories and National Electric Code requirements. The knockout hole is sized for a 35 mm conduit fitting.
WARNING TO AVOID DAMAGE OR PERSONAL INJURY, FOLLOW THE ELECTRICAL SCHEMATIC EXACTLY WHEN CONNECTING THE UNIT.
.
The HY-3E HyPerSteam™ and HY-5E model convenction steamers operate at 400 Volts (Three Phase) or 230 Volts (One Phase)
ELECTRICAL SUPPLY CONNECTIONS
Model Voltage Maximum Kw Field Wiring Current Demands
HY-3E
HY-5E
400 - 3 Phase 8 14 AWG 13 Amps 230 - 1 Pahse 8 8 AWG 33 Amps 400 - 3 Phase 15.5 12 AWG 23 Amps 230 - 1 Phase 15.5 6 AWG 63 Amps
7
OM/SM-HY-3E & HY-5E(CE)
Connect appropriate wiring as described in the wiring diagram located on the inside of the unit’s right side panel. Incoming power connections are shown below.
HY-3E Electrical Connections
The equipotential terminal is located on the left rear of the units.
F. EQUIPOTENTIAL TERMINAL
In accordance with national regulations, each unit are fitted with an equipotential terminal.
G. BRANCH CIRCUIT PROTECTION
Each HY-3E Steamer should have its own branch circuit protection. Current and power
demands for the different units are as shown in the table on page seven.
2. Water Connection(s)
Install a check valve to prevent back flow in the incoming cold water line, as required by local plumbing codes. Water pressure in the line should be between 30 and 60 PSIG (210 and 420 kPa). If pressure is above 60 PSIG (420 kPa), a pressure regulator will be needed.
7.5 LITER STEAM GENERATOR VOLUME MUST BE FILLED WITHIN THREE MINUTES AND 30 SECONDS.
HY-5E Terminal Block
A ¾ inch BSPT connector is used to attach the water supply to the inlet valve. Minimum water feed line diameter is ½ inch (13mm). Use a washer in the hose connection. Do not allow the connection to leak, no matter how slowly.
8
3. Drain Connection
Level the steamer front to back, or even pitch it slightly to the rear by adjusting the bullet feet on the stand or cabinet base.
A two inch (50mm) ID hose should be attached to the drain pipe and elbow supplied.
WARNING:
DO NOT CONNECT THE DRAIN DIRECTLY TO A BUILDING DRAIN. BLOCKING THE DRAIN IS HAZARDOUS.
There must be at least one-half inch free air gap between the end of the hose and the building drain. The free air gap should be as close as possible to the unit drain. There must also be no other elbows or other restrictions between the unit drain and the two inch free air gap.
CAUTION DO NOT USE PLASTIC PIPE. DRAIN MUST BE RATED FOR VERY HOT WATER.
OM/SM-HY-3E & HY-5E(CE)
Install the drain line with a constant downward pitch.
IMPORTANT: Do not allow water traps in the line. A trap can cause pressure build-up in the cavity, which may cause the door gasket to leak.
9
OM/SM-HY-3E & HY-5E(CE)
Operation
WARNING ANY POTENTIAL USER OF THE EQUIPMENT SHOULD BE TRAINED IN SAFE AND CORRECT OPERATING PROCEDURES.
A. Controls
Operator controls are on the front right of the unit. The control panel has the following touch pads and indicator lights. (Your controls may have either words or the symbols shown below):
The ON/OFF touch pad gets the HyPerSteam ready for use, or shuts it off.
The READY indicator light shows that the steam generator is at standby temperature and the cavity is hot enough to begin steaming.
The CLEANING indicator lights when the unit is operating in the cleaning mode.
The SERVICE indicator light shows when the water level probes have stopped working, and need to be cleaned (normally an indication of lime deposits).
When one probe is not working, the SERVICE light flashes briefly every few seconds. When both probes fail, the light will flash continuously and the beeper will sound.
The HI TEMP indicator light comes on when the steam generator is too hot.
The unit will automatically shut off, and cannot be turned on again until it has been serviced.
The TIMING indicator light stays on when the timer is running.
2 When a cook time is set, the unit steams until
the timer reaches OFF. The steaming stops, a red light comes on and a beeper sounds.
3 With the timer turned to the ON position, the unit
steams continuously. The green light stays lit. The steamer will not time down.
B. Operating Procedure
1. Press the ON switch/pad for the steamer. The steam generator will fill, and heat until the READY light comes on. (About 10 minutes.)
2. Load food into pans in uniform layers. Pans should be filled to about the same levels, and be even on top. The maximum allowable weight of food is 9.8 Kilograms (21.6 lbs.) Per pan.
3. Open the door and slide the pans onto the supports. If you will only be steaming one pan, put it in the middle position.
4. Close the door. With the READY indicator lit, take one of the following steps:
! If you want to steam the food for a certain
length of time, set the timer for that period. The timer will automatically run the steamer for the set time and then turn it off. A red light will come on and a beeper will sound. Steam production stops.
! To steam continuously, turn the timer to the
manual ON position. A green light will come on. The unit will continue steaming until you stop it by turning the timer to OFF. When steaming continuously YOU MUST CONTROL STEAMING TIME.
The CLEAN touch pad is used to start the automatic 50 minute cleaning cycle.
The timer is used in three ways:
1 In the OFF position the steam generator stays
at a low boil or “holding” temperature.
WARNING WHEN YOU OPEN THE DOOR, STAY AWAY FROM THE STEAM COMING OUT OF THE UNIT. THE STEAM CAN CAUSE BURNS.
10
OM/SM-HY-3E & HY-5E(CE)
5. Ope n the door. Remove the pans from the steamer, using hot pads or oven mitts to protect your hands from the hot pans.
6. To shut down the unit, press the ON switch/pad to OFF. The steam generator will automatically drain.
11
OM/SM-HY-3E & HY-5E(CE)
Cleaning
To keep your HY-3E or HY-5E Steamer in proper working condition, use the following procedure to clean the unit. This regular cleaning will reduce the effort required to clean the steam generator and cavity.
A. Suggested Tools
1. Mild detergent
2. Stainless steel exterior cleaner such as Zepper®
3. Steam generator de-liming agent, such as Groen Delimer Descaler, Lime-Away® or an equivalent. A liquid de-liming agent will be easier to use than crystals or powders. See the warning about chlorides, below
4. De-greaser, such as EncompasS®, Malone 34®, Puritan Puribrute®, or Con-Lie®
5. Cloth or sponge
6. Plastic wool or a brush with soft bristles
7. Spray bottle
8. Measuring cup
9. Nylon pad
10. Towels
11. Plastic disposable gloves
12. Funnel
B. Procedure
1. Exterior Cleaning
a. Prepare a warm solution of the mild
detergent as instructed by the supplier. Wet a cloth with this solution and wring it out. Use the moist cloth to clean the outside of the unit. Do not allow freely running liquid to touch the controls, the control panel, any electrical part, or any open louver.
WARNING DISCONNECT THE POWER SUPPLY BEFORE CLEANING THE OUTSIDE OF THE STEAMER. KEEP WATER AND CLEANING SOLUTIONS OUT OF CONTROLS AND ELECTRICAL COMPONENTS. NEVER HOSE OR STEAM CLEAN ANY PART OF THE UNIT.
DON’T MIX DE-LIMING AGENTS (ACID) WITH DE-GREASERS (ALKALI) ANYWHERE IN THE UNIT
AVOID CONTACT WITH ANY CLEANERS, DE-LIMING AGENT OR DE­GREASER AS RECOMMENDED BY THE SUPPLIER. MANY ARE HARMFUL. READ THE WARNINGS AND FOLLOW THE DIRECTIONS!
EVEN WHEN THE UNIT HAS BEEN SHUT OFF, DON’T PUT HANDS OR TOOLS INTO THE COOKING CHAMBER UNTIL THE FAN HAS STOPPED TURNING.
DON’T OPERATE THE UNIT UNLESS THE REMOVABLE PARTITION HAS BEEN PUT BACK IN ITS PROPER LOCATION.
b. To remove material which may be stuck to the
unit, use plastic wool, a fiber brush, or a plastic or rubber scraper with a detergent solution.
c. Stainless steel surfaces may be polished with a
recognized stainless steel cleaner such as Zepper®.
IMPORTANT DO NOT USE ANY METAL MATERIAL (SUCH AS METAL SPONGES) OR METAL IMPLEMENTS (SUCH AS A SPOON, SCRAPER OR WIRE BRUSH) THAT MIGHT SCRATCH ANY STAINLESS STEEL SURFACE. SCRATCHES MAKE THE SURFACE HARD TO CLEAN AND PROVIDE PLACES FOR BACTERIA TO GROW. DO NOT USE STEEL WOOL, WHICH MAY LEAVE PARTICLES IMBEDDED IN THE SURFACE WHICH COULD EVENTUALLY CAUSE CORROSION AND PITTING.
DON’T USE ANY CLEANING OR DE­LIMING AGENT THAT CONTAINS ANY SULFAMIC AGENT OR ANY CHLORIDE, INCLUDING HYDROCHLORIC ACID (HCl). TO CHECK FOR CHLORIDE CONTENT SEE ANY MATERIAL SAFETY DATA SHEETS PROVIDED BY THE CLEANING AGENT MANUFACTURER.
12