![](/html/02/0223/022362c1ec2fb7db4aa28d848437f0875053b8ae0cb1636eff5dc626790fe0b6/bg1.png)
10 Pan Capacity
Stainless Steel
Pressureless Steamer
With Electric
Pressure Boiler
In Cabinet Base
HyPlus Pressureless Steamer Model HY-10SE
Description
Steamer is a Groen HyPlus™ stainless steel twin cavity 10 pan pressureless steamer, with cabinet mounted
(specify 24, 36, or 48 KW) electric steam boiler.
Construction
Steamer cavities and cabinet base are all stainless steel
construction. Steamer unit has a unitized body, with
removable right side panel providing access to internal
components. Steamer doors are all stainless steel with
strong continuous hinge and are field reversible for left
or right swing. Doors are insulated and provided with a
one piece, replaceable seal. Easy open handle and latch
provides positive lock and seal when door is pushed or
slammed shut.
Hidden magnetic door switch cuts power to blower and
steam flow to that cavity, when the door is opened. Pan
support racks are polished stainless steel and removable
for easy cleaning. Wide drip sink with condensate drain is
positioned under cavity doors.
Cabinet base has a stainless steel frame with all stainless
steel top deck, with hinged front access panel and removable side and rear panels standard. Front and rear legs
have adjustable bullet feet.
Finish
Cabinet exterior including doors are finished to a #3 uniform finish. Cavity interiors are polished stainless steel.
Control panel face plates are smudge resistant polyester
film, ensuring maximum ease in cleaning and maintaining
a brilliant finish.
Controls
Steamer cavity controls are mounted on the front panel
for easy replacement or repair and include separate
ON-OFF/60 minute timer control with constant steam
setting, for each cavity. Electric boiler is provided with a
power-ON switch, RESET light, start switch, low water
sensor, pop safety valve, water level sight glass and outside cabinet mounted pressure gauge.
Performance Features
Unit will shut off if water level is low or unit builds too
much pressure. When power switch is turned “off”, the
boiler automatically drains to reduce sediment build-up,
after water has cooled to 130°F. Each steamer cavity has
a powerful side mounted blower, which increases steam
velocity and provides efficient steam distribution throughout cavity and between loaded pans.
Cabinet Base Steam Source
Unit has an electric heated cabinet mounted pressure
boiler to provide atmospheric steam to each chamber
at a temperature of approximately 212°F. Boiler is constructed for 15 PSI maximum, 24KW model delivers 2.2
boiler horsepower, the 36KW model delivers 3.5 boiler
horsepower and the 48 KW model delivers 4.7 boiler
horsepower.
Pan Capacity
Pan Size Per Cavity Total
12 x 20 x 1” 10 20
12 x 20 x 2 1/2” 5 10
12 x 20 x 4” 3 6
Installation
Specify 208, 240 or 480 Volt, 3 phase, 60 cycle electrical
service. Unit requires 1/2” NPT cold water supply line and
1 1/4” NPT free venting drain.
Steam Source For Adjacent Equipment
A 1/2” NPT power take-off valve is standard on all 36 and
48KW units. To ensure proper performance, boiler must be
properly sized to meet boiler horsepower requirements of
steamer cavities and additional equipment. Appropriate
steam traps and piping must be professionally installed.
Water Supply Requirements
All water boiler systems are subject to contamination and
failure due to mineral content found in most water supplies.
To minimize service problems, a water treatment (softening) system is recommended when water quality is found to
exceed limits stated below and in operator manual.
Recommended MINIMUM water quality standards are: Total
dissolved solids (TDS) content should not exceed 30 parts
per million; and the water pH should be 7.0 to 9.0.
Options/Accessories
Flanged mounting feet
Second water connection for condensate spray
Origin of Manufacture
Steamer is designed and manufactured in the United
States.
Short Form
Unit is a Groen HyPlus
pressureless steamer with
electric heated pressure boiler
mounted in a cabinet base.
All stainless steel construction,
with two independent steamer
chambers each with powerful
blower to circulate steam
within cavity and individual
60 minute timer with constant
steam setting. Doors are
insulated, field reversible with
easy open latch and hidden
magnetic door switch. Drip
sink with condensate drain
is provided under cavity
doors. Five (2 1/2” deep) pan
capacity per chamber. Cabinet
base has stainless steel frame,
all stainless steel exterior
with front access panel and
adjustable bullet feet. Boiler
is constructed for 15 PSI
maximum, with choice of
24, 36 or 48KW power input.
Power takeoff to divert steam
to adjacent equipment is
standard on all 36 and 48KW
units. Unit comes standard
with automatic boiler drain.
See other side for water,
drain and electric connections
required. Made in USA.
Applications
Pasta
Rice
Vegetables (Fresh & Frozen)
Seafood (Fresh & Frozen)
Poultry
Potatoes
Eggs
Meats
Reheat Cook-Chill &
Prepared Foods
1055 Mendell Davis Drive, Jackson, MS 39272
888-994-7636, unifiedbrands.net
Please reference our website for the most
updated product information and specifications.
Groen HyPlus
162020A
Released 04/12
![](/html/02/0223/022362c1ec2fb7db4aa28d848437f0875053b8ae0cb1636eff5dc626790fe0b6/bg2.png)
Model HY-10SE
162023A
1055 Mendell Davis Drive, Jackson, MS 39272, 888-994-7636, unifiedbrands.net
© 2009 Unified Brands. All Rights Reserved. Unified Brands is a wholly-owned subsidiary of
Dover Corporation.