![](/html/87/87a2/87a2d056e6e78c499913a96f1a37af5622ddf7988e29edb9731170b39178d9c4/bg1.png)
CAPKOLD® COOK-CHILL SYSTEMS
PROJECT NAME:
LOCATION:
ITEM NO:
COMPRESSED AIR SYSTEM MODEL CKAC
CapKold® air compressor, designed to provide sufficient volume of clean, high pressure compressed air at 90
PSIG, necessary for all air powered or air activated equipment and components in the CapKold® Cook-Chill
Production Kitchen.
AVAILABLE MODELS:
CKAC-3-6H (3HP, 60 Gal. Horizontal Tank)
CKAC5-8H (5HP, 80 Gal. Horizontal Tank)
CKAC7.5-12H (7.5HP, 120 Gal. Horizontal Tank)
CKAC10-12H (10HP, 120 Gal. Horizontal Tank)
CKAC15-12H (15HP, 120 Gal. Horizontal Tank)
AIR COMPRESSOR SIZING GUIDE:
Review proposed equipment package and note those
components that utilize compressed air. Multiply flow
rate by the number of units, then total the far right
column for maximum SCFM total required.
AIR COMPRESSOR MODEL GUIDE:
To ensure sufficient compressed air volume, specify a
compressor with a CFM delivery rate equal to or
higher than the total cfm required for all system
components and applications listed above.
AIR COMPRESSOR CONSTRUCTION
(ALL MODELS):
• Splash lubricated reciprocating compressor with
cast iron cylinders and heads
• Alloy steel, self-cleaning reed valves
• NEMA rated electric motor with enclosed, hinged
belt guard
• Air intake filter/silencer
QTY:
MODEL NO:
AIA NO:
SIS NO:
CKAC Compressed Air System.
OPTIONS/ACCESSORIES:
Vertical air receiver tank, refrig-
erated air dryer would ship
loose and mount separately.
NOTES:
• If CKPF/3 Pump/Fill (with clipper) and additional
Model CVE or CVW vacuum clipper will not be used
simultaneously, 8 SCFM may be deducted from
total air
• If multiple kettles with air valves are specified,
typically only one will require air during product
transfer using the CKPF/3 Pump/Fill
• Vertical Tank models can be specified in installations
where available space in utility room is limited.
Vertical and horizontal tank units of the same size
have similar performance
CONTROL SYSTEMS:
• Automatic start-stop operation
• 0-200 PSIG air pressure gauge on tank
• Manual drain tank
• Refrigerated air dryer
• Automatic tank drains
• Vibration isolators
• Mounted and wired magnetic starters
• Low Oil Monitor
• Air cooled after-cooler (mounted)
ORIGIN OF MANUFACTURE: Designed and
manufactured in the United States.
CapKold Accessories
CKAC 160676 RevA
Revised 10/13
![](/html/87/87a2/87a2d056e6e78c499913a96f1a37af5622ddf7988e29edb9731170b39178d9c4/bg2.png)
UTILITY CONNECTIONS (ALL MODELS)
PHY
WITH STARTER, DISCONNECT, AIR DRYER, FILTERS
AND REGULATOR
160677 REV A
CK
IW2
CA
C
IW
IW1
EP
IW
EP
TOP VIEW
IW2
AIR FILTERS ARE SUPPLIED AND INSTALLED
IW2
B
IW
CA
CA
IW1
A
SICAL DIMENSIONS
MODEL
CKAC3-6H
CKAC5-8H
CKAC7.5-12H
CKAC10-12H
CKAC15-12H 100-1/2"
SYMBOL
DESCRIPTION
CONNECTION
MODEL
CKAC3-8H
CKAC5-8H
CKAC7.5-12H
CKAC10-12H
CKAC15-12H
A
70" 50"
77"
100-1/2"
100-1/2"
B
50"
50"
55"
55"
CA IW
COMPRESSED
AIR
OUTLET
3/4" NPT
COMPRESSED
AIR @
175 PSI
9.7 CFM
16.5 CFM
22.9 CFM
34.8 CFM
49 CFM
31-1/2"
31-1/2"
28-1/4"
28-1/4"
HP
3
5
7.5
10
15
INSTALL OUTDOORS OR IN A FREEING AMBIENT ENIRONMENT OR A LOCATION THAT ECEEDS 100 F.
FRONT VIEW
C
27"
AUTOMATIC
ELECTRICAL
208, 230/460/3/60
12 A, 11 A, 6 A
20 A, 19 A, 11 A
29 A, 26 A, 15 A
36 A, 32 A, 18 A
48 A, 44 A, 22 A
RECOMMENDED CLEARANCES
FRONT
48"
48"
48"
48"
48"
DRAIN
RIGHT
LEFT
12" 12" 12"
12"
12"
12"
12"
12" 12"
12"
12" 12" 12"
IW1IW2
MANUAL
TANK
DRAIN
REFRIGERATED
DRYER
TANK
1/4" HOSE3/8" NPT1/4" NPT
WEIGHT (lbs.)
SHIPPING
580
630
920
990
1080
SIDE VIEW
REAR
12"
12"
EP
POWER
SUPPLY
3/4"
1055 Mendell Davis Drive, Jackson, MS 39272, 888-994-7636, unifiedbrands.net
© 2013 Unified Brands. All Rights Reserved. Unified Brands is a wholly-owned subsidiary of Dover Corporation.