THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE. READ,
UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS
CONTAINED IN THIS MANUAL.
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND
LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE
.
Information contained in this document is
known to be current and accurate at the time
of printing/creation. Unified Brands recommends referencing our product line websites,
unifiedbrands.net, for the most updated
product information and specifications.
OM-CC-E
IMPORT ANT — READ FIRST — IMPORTANT
WARNING:
CAUTION:SHIPPING STRAPS ARE UNDER TENSION AND CAN SNAP BACK WHEN CUT.
CAUTION:
CAUTION:
WARNING: TO AVOID DAMAGE OR INJURY, FOLLOW THE WIRING DIAGRAM EXACTLY WHEN
CAUTION:
WARNING:
WARNING:
IMPORTANT:
IMPORTANT:
WARNING:
THE UN IT MUST BE INSTALLED BY PERSONN EL QUALIFIED TO WORK WITH ELECTRICITY
AND PLUMBING. IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND/OR
DAMAGE TO THE EQU IPMENT. THE UNIT MUST BE INSTALLED IN A CCORDANCE WITH
APPLICABLE CODES.
DO NOT INSTALL THE UNIT IN ANY WAY WHICH WILL BLOCK THE RIGHT SIDE VENTS,
OR WI THIN 12 I NCH ES O F A H EAT SOURCE SUCH A S A BRAISIN G PAN , DEEP FRYER,
CHAR BROILER OR KETTLE.
LEVEL THE UNIT FRONT TO BACK, OR PITCH IT SLIGHTLY TO TH E REA R, TO A VOID
DRAINAGE PROBLEMS.
CONNECTING A UNIT.
DO NOT USE PLASTIC PIPE. DRAIN MUST BE RATED FOR BOILING WATER.
DO NOT CONNECT THE DRAIN DIRECTLY TO A BUILDING DRAIN.
BLOCKING THE DRAIN IS HAZARDOUS.
Improper drain connection will void warranty.
Do not al low any wat er traps in t he line. A t rap can cause pressure t o build up inside t he
cavit y during steaming, which will make the door gasket leak.
WHEN YOU OPEN THE DOOR, STAY AW AY FROM STEAM COMI NG OUT OF THE UNIT.
STEAM CAN CAUSE BURNS.
WARNING: BEFORE CLEANING THE OUTSIDE OF THE STEAMER, DISCONNECT THE ELECTRIC POWER
SUPPLY. KEEP WATER AND CLEANING SOLUTIONS OU T OF CON TROLS AN D ELECTRICAL
COMPONEN TS. NEVER HOSE OR STEAM CLEAN ANY PART OF THE UNIT.
WARNING:
WARNING:
WARNING:
WARNING: DO NOT PUT HANDS OR TOOLS INTO THE COOKING CHAMBER UNTIL THE FAN HAS
WARNING:
NOTICE:
NOTICE:
WARNING:
ALLOW COOKING CHAMBER TO COOL BEFORE CLEANING.
CAREFULLY READ THE WARNINGS AND FOLLOW THE DIRECTIONS ON THE LABEL OF EACH
CLEANING AGENT.
DELIMING AGENT MANUFACTURER.
DO NOT MIX DE-LIMING AGENTS (ACID) AND DE-GREASERS (ALKALI).
STOPPED TURNING.
DO NOT OPER ATE THE UNIT UNLESS THE R EMOVA BLE RIG HT SIDE PANEL H AS BEEN
RETURNED TO ITS PROPER LOCATION.
DO NOT USE A CLEANING OR DE-LIMING AGENT THAT CONTAINS ANY SULFAMIC ACID
OR ANY CHLORIDE, INCLUDING HYDROCHLORIC ACID. IF THE CHLORIDE CONTENT OF
ANY PRODUCT IS UNCLEAR, CONSULT THE MANUFACTURER.
DO NOT USE ANY DE-GREASER THAT CONTAINS POTASSIUM HYDROXIDE OR SODIUM
HYDROXIDE OR THAT IS ALKALINE.
USE OF ANY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY GROEN OR THEIR
AUTHORIZED DISTRIBUTOR VOIDS ALL WARRANTIES AND CAN RESULT IN BODILY INJURY
TO THE OPERATOR AND DAMAGE THE EQUIPMENT. SERVICE BY OTHER THAN FACTORYAUTHORIZED PERSONNEL WILL VOID ALL WARRANTIES.
USE SAFETY GLASSES A ND R UBBER GLOVES AS RECOMMENDED BY
WARNING:
HIGH VOLTAGE EXISTS INSIDE CONTROL COMPARTMENTS. DISCONNECT FROM BRANCH
BEFORE SERVICING. FAILURE TO DO SO CAN RESULT IN SERIOUS INJURY OR DEATH.
UNDERWRITERS LABORATORIES, INC.
333 Pfingst en Road
Northbrook, Illinois 60062
KLENZADE SALES CENTER
ECOLAB, Inc.
370 Wabasha
St. Paul , Minnesota 55102
800 328-3663 or 612 293-2233
................................................
31
References
NATIONAL FIRE PROTECTION
ASSOCIATION
60 Battery March Park
Quincy, Massac husetts 02269
NFPA/70 The National Electrical Code
NATIONAL SANITATION FO UNDATION
3475 Pl y m outh Road
Ann Arbor, Michigan 48106
3
OM-CC-E
Equi p ment D escr i p ti o n
Your Groen Convection Combo™ has a stainless
steel cooking ch amber , a n a ir hea ting compa rtment
with electri c hea ting elements an d fan, a steam
generator with electric h eat ing elements, an d a
control compartment which houses other electrical
component s.
All m ajor compon ents of the Conv ection Combo™
are encased in a 16 gauge stainless st eel ca binet.
Glass fiber insulation, lines the cabinet at a thickness
of 1½ to 2 i nch es (4 to 5 cm ). A remov able drip tray
is locat ed benea th the door.
Door hinges are reversible so that doors ma y open
from t he left or r ight side. Operator controls are
located on the ri ght side of th e front panel.
Standard cont rols l et you to opera te the Con vection
Combo in a ny one of three cooking modes:
1. As a conv ection oven
2. As a self-contained, pressureless steamer
3.As a combination oven-steamer
Models CC10- E an d C C 20-E differ in cooking
chamber size and capacity:
CC10-E: 4 steam t able pans (12x20x2½”), or
7 half- size (13x18" ) U S bak ing pans
CC20-E: 10 steam t able pans (12x20x2½”), or
9 ful l-si ze (18x26") US baking pan s
The smaller Conv ection Combo™ is ava ilable as a
table- top unit (the single CC10-E ). These units a re
also supplied on a stain less steel stand as models
CC10-EF an d (2)CC 10-EF. The larger Con vection
Combo™ is alw a y s supplied with a stand as the
single CC20-EF or the double-stacked (2)CC 20-EF.
The Convection Combo™ Fam ily: 1. Model (2)CC20-EF (Full- sized double-stacked uni t on rigi d stand),
2. Model CC-20-EF ( Full-sized si ngle unit on a convenient stand), 3. Model (2)CC10-EF (Double-stacked,
stand- m ounted, half- pan C om bo, 4. Model CC10-EL singl e four inch l eg-mounted. (Also availabl e in
tabl etop (CC10-E) and stand-mounted (CC10-EF) versi ons.
4
Insp ecti o n an d U n p acki n g
OM-CC-E
Your Convection Combo™ will be completely
assembled in a hea vy shipping car ton or w ooden
crate, and attach ed to a skid. On receipt, inspect
the carton or crate carefully for exter ior damage.
CAUTION
SHIPPING ST RAPS ARE UNDER TENS ION AND
CAN SN AP BA CK WHEN CUT.
Carefully cut the straps around the carton and detach
the sides of the carton from the skid. Pull the carton
up off the unit. Be careful to avoid personal injury or
equipm e nt d amage from staples which might be left in
the carton w alls.
Water Conditioning
It is essential to supply the steam generator with
water that will n ot form scale. Even though the
steam gen erator is engineered to minimize sca le
formati on, scal e development depends on the
hardness of your water and the number of hours you
operate t he equ ipmen t.
In some areas, water is low enough in mi ner al
content to avoid scale formation. But most water
supplies are full of minera ls which form scale. It is
this scale which could lead to an early component
failure.
Your water utility can tell you about the minerals in
your wa ter. The water going to the steam gen era tor
should h a v e between 30 and 40 parts per million
(ppm) total dissol ved solids (TDS) a nd sh ould ha ve a
pH (acidity rating) of 7. 0 to 9.0. Please follow t hese
simple precautions:
Do notrel y on unproven water treat m ents
1.
which a re sold for scale prevention or scale
removal. They don’t always work. The best
way to preven t scale is to supply the purest
possible water (30 - 40 ppm TD S).
Write down the model number, serial number and
installation date and keep this information for future
reference. Space for these entries is provided at the
top of the Ser vice Log in the back of this manual.
CAUTION
THI S UNIT IS VERY HEAVY. YOU SHOULD GET
HELP AS NEEDED TO LIFT THIS WEIGHT
SAFELY.
When starting installation, lift the unit stra ight up off
the skid. Check pa cking materials to make sure
loose part s ar e not discarded w ith the material.
softener will provide longer generator life, higher
steam capacity, and reduce maintenance
requirements.
If you notice a slowdown in steam pr oduction,
3.
hav e the un it checked for scale build-up. H eav y
scale reduces the unit’s ability to boil water, and
can even cause hea ting elements in the steam
generator to overheat an d burn ou t.
MINIMIZE SCALE PROBLEMS, BY USING AND
MA INTAINING A SOFTENER , AND BY CLEANING
THE STEAM GENERATOR REGULARLY.
Groen Con vection C om bo™ ovens are also ava ilable
with an option for two separate water conn ections —
one for the stea m gener ator (soft water ), the other
for the spra y condenser (untreated wa ter). The
steam gen erator only uses 14 to 31% of a
combination oven’s water.
Since softener systems are typically sized by total
GPH (gallons per hour), the second connection could
reduce tr eat m ent requirements by u p to 80%,
resulting in significant sa v in gs.
2.If your water contains scale-forming minerals, as
most wa ter does, use a well -ma inta ined water
soften er. Wh ether an ex changeable soft ener
cartridge or a regener ating system is chosen, a
regular exchange schedule is essential.
Insta llin g a wa ter meter between the softener and
the steamer will provide an a ccurate gauge of water
use, and will help determine when to exchange
cartr idges or regenera te the softener. Using a water
5
OM-CC-E
Installation and Start-Up
WARNING
THE UNIT MUST BE INSTALLED BY PERSONNEL WHO ARE QUALIFIED TO WORK WITH ELECTRICITY AND
PLUM B ING. IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO T HE
EQUIPMENT. THE UNIT MUST BE INSTALLED IN A CCO RDA NCE WITH APPLICABLE CODES.
CAUTION
DO NOT INSTALL THE UNIT WITH THE RIGHT SIDE VENTS BLOCKED OR WITHIN 12 INCHES OF A HEAT
SOURCE (SUCH AS A BRAISING PAN, DEEP FRYER, CHAR BRO IL ER O R K ET TL E) . D O NO T INS T AL L T O
THE LEFT OF ANY O PEN-FLAME EQUI PMEN T.
TO AVOID DRAINAGE PROBLEMS, LEVEL THE UNIT FRONT TO BACK.
A.MODEL CC10-E
Terminal block
1. M ounting
d.
If you wish t o install a Con vection C om bo™ on
top of a nother, you shoul d obta in a double
stacked un it fr om the factory.
If the unit does not have a factory-installed stand,
the install er must pr ovide a table, stan d or
counter w hich is strong enough to support th e
unit. Use of casters is not recommended.
To avoid drainage problems, level the unit fron t
to rea r, or provide a slight pitch to the rear.
Bolt the unit to the table, stand or coun ter top,
using the mounting holes in its base.
2. Electrical Supply Connections
Panel Removal
a.
The right si de panel must be removed to gain
access to the w iring and control
compartment. Remove the two screws at
the bott om of t he panel . Slide the panel
toward the front of the unit, lift it and set it
aside.
Supply Vol tage
b.
The CC10-E must oper ate at th e rated
nameplate voltage, plus or minus 10%.
Phase Select Plug (Units manufactured
c.
before 1996)
Locate the phase select plug assem bly on
the wiring harn ess from the relay board.
This assembly is black, blue and red. Refer
to t he labels located below the mot or and
above the distri bution block for the correct
phase connection.
The terminal block for incom ing power is
located at t he back of t he control
compartment.
WARNING
WHEN CONNECTING FOR SINGLE PHASE
OP ERATI ON, D O NO T C ONNE C T ANY WI R E TO
LINE 3 (THE TERMINAL FARTHEST LEFT). THIS
WILL CAUSE A SHORT CIRCUIT.
The ground terminal is found on the relay
bracket below the terminal block. The
Convection C om bo™ m ust have a separate
ground wire for safe operatio n. The ground
wire must be at least 10 AWG (2.6 mm).
e. Supply Wire
The type of wir e needed is determined by
fin ding the operating voltage and phase from
the unit’s back data plate an d (on pre-1996
models) phase select connector. Re fer to
the “Elect rical Supply Connection” label on
the back of the unit for correct wire size and
insulation temperatu re rating.
The specified w ire m ust be used to com ply
with U nderwr iters Laboratories and National
Elect ric Code requirements.
The knockout hole i s sized for a ¾ inch (19
mm) conduit fitting.
6
CC10-E ELECTRICAL SUPPLY CO NNECTION
(Al l w ires copper only.
Reference: National Electri cal Code)
4. Drain Co nnectio n
CC10-E Without Drai n Tank (tabletop model)
a.
OM-CC-E
Volt agePhaseWire SizeInsul ation
20816AWG (4.1m m )75
20818AWG (3.3m m )90
20838AWG (3.3m m )75
24018AWG (3.3m m )75
24038AWG (3.3m m )75
Branch Circuit Protection
f.
o
C
o
C
o
C
o
C
o
C
Groen strong ly recommends tha t each
Convection Co mbo™ have its own branch
cir cuit protecti on. A double sta cked u nit should
have separat e protection for the upper and
lower steamer-ovens.
CURRENT DEMAND
VoltageCurrentPower
1 Phase3 Ph., per Line
20844.7 A27.5 A9.3 KW
24038.8 A24.1 A9.3 KW
Each current-carrying conductor must have
overcurrent protect ion. Refer to the label on
the back of the unit for pr oper w ire size an d
type. Watertight connections are required.
3. Water Supply Connection
A check val ve (back siph onage devi ce) mu st be
installed in th e incoming cold water line in keeping
with local plum bing codes. Wat er li ne pressur e
should be between 30 and 60 PSI ( 210 and 410
kPa). A pressure regulator is requir ed above 60
PSI (410 kPa).
A ¾ inch (19 mm) N H (gar den hose ty pe)
connector is required t o connect t he water supply
to t he wat er inlet valve. The w ater feed line
diameter ma y not be less that ½ inch (13 mm) .
Use a washer (or if necessary, tw o washers) in the
hose connection. Do not allow the connection to
have any leak, no matter how small.
A 1½ inch (4 cm) hose ma y be attached to the
provided dr ain elbow wit h a cla m p. Do not use
plastic pipe. The drain must withstand boiling
water.
WARNING:
DO NO T C O NNECT THE DRAIN DI RE CT LY TO A
BUILDING DRAIN.
There mu st be a free air gap between the end
of th e hose and t he building drain. The free air
gap shou ld be as close as possible t o th e unit’s
drain. There must also be no other elbows or
other restrictions between the unit drain and the
two inch free air gap.
CAUTION
DO NOT USE PL AST IC PIPE. DRAIN MUST BE
RATED FOR BOILING WATER.
WARNING
BLOCKING THE DRAIN IS HAZARDOUS.
Install the drain line with a constant downward
pitch.
IMPORTA NT: Do not allow any water traps in the
li ne. A trap can cause pressure to build up inside
the cavi ty during st eam ing, which will make the
door gasket leak.
NOTE: Improper drain connection will void the w a r ra n ty .
b. CC10-E With Drain Tank
A 1½ inch (4 cm) ID hose may be atta ched to
the supplied dr ain elbow wit h a cla m p. The
hose may be connected directly to a building
drain since the drain tank has an air vent, which
elim inates th e need for a fr ee air gap at the
building drain. Do not block the air vent in any
way. Do not attach anything to the vent tu be or
reduce it s size .
Do NO T use plastic pipe i n the drain line,
because the drain must withstand boiling w a ter.
If you r CC10-E is equipped with the optional split
water su pply, the supply for each steam gen era tor
must be able to fill the generator with 1½ gallons
(5.7 liters) or water in 1½ minutes. The make-up
water rate is 0.06 gall ons per min ute (0.2 lit ers per
minute). Condensate spray water rate is 0.34
gallons per minute (1.3 l iters per minute) at 30 PSI
(210 kPa).
7
Drain Tank
Tabletop Model
OM-CC-E
Proper Drain Line Connections
8
B.MODEL CC20-E
Mounting
1.
If you wish t o install one Con vection C om bo™
above another , obtain a double-stacked unit from
the fact ory.
CAUTION
DO NOT INS T AL L A CC 20 -E IN AN Y L O CATI ON
WHERE RIGHT SIDE VENTS ARE BLOCKED, OR
WIT HIN 12 INC HE S O F A HEAT S OURCE SUCH
AS A BRAISING PAN, DEEP FRYER, CHAR
BROI LER OR KETTLE.
DO NOT INSTALL THE UNIT TO THE LEFT OF
ANY OPEN FLAME EQU IPMENT.
OM-CC-E
breaker or 10 AWG ( 2.6 mm) for a 40 to 60
amp brea ker.
d. Supply Wire
The type of wir e needed is determined by
fin ding the operating voltage and phase from
the unit’s back data plate and phase select
conn ector. Refer to the “Electrical Supply
Connection” label on the back of the unit for
correct wire size and insulation temperature
rating.
The specified w ire m ust be used to com ply
with U nderwr iters Laboratories and National
Elect ric Code requirements.
To avoid drainage problems, level the unit fron tto-rear , or provide a slight pitch to the rear.
WARNING
THE UNIT MUST BE INSTALLED BY
PERSONNEL QUALIFIED TO WORK WITH
ELECTRICITY AND PLUMBING. IMPROPER
INSTALLATION CAN CAUSE INJURY TO
PERSONNEL AND/OR DAMAGE TO
EQUIPMENT.
CAUTION
INSTALLATION MUST BE IN ACCORDANCE
WITH ALL APPLICABLE CODES.
Elect ri cal Supply Connections
2.
a.Panel Removal
The right si de panel must be removed to gain
access to the w iring and control
compartment. Remove the screw a t th e
back of the panel. Sli de th e panel toward
the front of the u n it, lift it and set it a side.
b. Supply Voltage
The CC20-E must oper ate at th e rated
nameplate voltage, plus or minus 10%.
c. Termi nal block
The terminal block for incom ing power is
located at t he back of t he control
compartment.
The knockout hole i s sized for a one in ch
(25.4 mm) conduit fitting.
CC20-E ELECTRICAL SUPPLY CO NNECTION
(Al l w ires copper only.
Reference: National Electri cal Code)
o
Voltage
2084 AWG (5.2 m m )6 AWG (4.1 m m )
2404 AWG (5.2 m m )6 AWG (4.1 m m )
4808 AWG (3.3 m m )8 AWG (3.3 m m )
e. Branch Circuit Protection
Voltage
Size for 75
(THWN)
Groen strong ly recommends tha t each
Convection Co mbo™ have its own branch
cir cuit protecti on. A double stacked unit
should have separate protecti on for the
upper and lower steam er-ovens.
CURRENT DEMAND
20865.4 A21 KW
24056.7 A21 KW
48028.3 A21 KW
Each current-carrying conductor must have
overcurrent protect ion. Refer to the label on
the back of the unit for pr oper w ire size an d
type. Watertight connections are required.
C
Current per l ine
(Three Phase)
Size for 90oC (THHN)
Power
The ground termina l is fou nd below the
ter m inal block. The Convection Combo™
must h ave a separate ground wir e for safe
operati on. The ground wire must be at least
8 AWG (3.3 m m ) for a 100 am p circuit
W ater Supply Connect ion
3.
A check val ve (back siph onage devi ce) mu st be
installed in th e incoming cold water line in
keeping with local plumbing codes. Water line
pressure should be between 30 and 60 PSI (210
9
OM-CC-E
and 410 kP a). A pressure regu lator i s requ ired
above 60 PSI (410 kPa ).
A ¾ inch (19 mm) N H (gar den hose ty pe)
connector is required t o connect t he water supply
to t he wat er inlet valve. The w ater feed line
diameter ma y not be less that ½ inch (13 mm) .
Use a washer (or if necessary, tw o washers) in
the hose connection. Do not allow the
connection to have any leak, no matter how
small.
Drain Connect ion
4.
CAUTION
DO NOT USE PLAST IC PIPE. DRAIN MUST BE
RATED FOR BOILING WATER.
WARNING
BLOCKING THE DRAIN IS HAZARDOUS.
IMPORTA NT: Do not allow any water traps in the
li ne. A trap can cause pressure to build up
insi de the cavity during steam ing, which will
make the door gasket leak.
NOTE: Improper drain connection will void the
warranty.
CC20-E With Drain Tank
A two inch (51 cm) ID hose may be attached to
the supplied dr ain elbow wit h a cla m p. Th e hose
may be connected dir ectly to a building drain
since the drain tank has an air vent, which
elim inates th e need for a fr ee air gap at the
building drain.
Do not block th e air vent in an y w a y . Do not
attach anythin g to the vent or reduce its size.
Do NO T use plastic pipe i n the drain line,
because the drain must withstand boiling w a ter.
10