Gree G17-135PACSW, G17-12PACSW, G17-12PACSH User Manual

4.3 (3)

Owner’s

Manual

Portable Room

Air Conditioner

G17-12PACSW

G17-12PACSH

G17-135PACSW With Heat Pump

Write the model and serial numbers below for your records:

Model #

Serial #

Date Purchased

Please read the entire manual carefully to ensure proper operation of the product.

To find an electronic version of this manual, please visit www.greeproducts.com

Phone: 1-866-658-0466

Email: customerservice@greeproducts.com

TABLE OF CONTENTS

 

PAGE

IMPORTANT SAFETY INSTRUCTIONS

............................................................................................... 3-4

INSTALLATION...................................................................................................................................

5-16

OPERATING INSTRUCTIONS..........................................................................................................

17-20

CLEANING & MAINTENANCE..........................................................................................................

21-24

BEFORE YOU CALL........................................................................................................................

25-27

WARRANTY..........................................................................................................................................

28

NOTICE:

This picture is for reference only. Please refer to the actual product for the appearance.

2

SAFETY INFORMATION

SYMBOL INDICATES A HAZARDOUS SITUATION WHICH IF NOT AVOIDED COULD RESULT IN SERIOUS INJURY OR DEATH.

Please read and understand this entire manual before attempting to assemble, operate or install your air conditioner. Use this unit only as instructed in this manual. While this manual covers a wide variety of troubleshooting, the instructions are not meant to cover every situation that may occur. Caution and common sense are to be practiced when installing, operating or maintaining your unit.

WARNING

Use caution when unpacking and installing. Fins may be sharp and could harm you.

Do not stop the unit by pulling out the power plug. This may cause electric shock or fire.

Replace immediately any part that has become frayed or damaged. Do not use a cord that shows damage or cracks along the length or at the connector. A damaged power cord should be replaced with a new cord obtained from the

manufacturer. Please contact Customer Service for replacement options.

Do not modify power cord length or share an outlet with another appliance. This may cause electric shock or fire.

Always use a dedicated power circuit. The voltage on the outlet should match the voltage rating on the rating plate.

The power cord is equipped with a 3-prong grounding plug which can only be used with a standard 3-prong wall outlet to minimize the possibility of electric shock hazard. Where

a 2-prong outlet is encountered, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet.

Do not use the outlet if it is loose or damaged. It may cause electric shock.

Do not open the unit during operation. It may cause electric shock.

Keep away from heating appliances, flammable gas, or combustibles such as gasoline, benzene, thinner, etc.

Ventilate room before operating air conditioner if there is a gas leak from another appliance.

Never use an extension cord, surge protector, or multi-outlet adapter with this unit.

Plug in power cord properly. Always unplug your air conditioner by pulling on the power plug. Grip plug firmly and unplug to remove.

Do not disassemble or modify the unit.

Do not operate with wet hands.

Do not clean with water that may run inside the units electrical parts. This may cause failure of the machine or electric shock.

Do not place obstacles around air-inlets or inside of air-outlet.

Switch off the unit and unplug the unit before cleaning.

To prevent injury, when the air filter needs to be removed, do not touch the metal parts of the unit.

Only clean outside of the unit, use only a mild detergent.

Always insert the filters securely. Clean the filter once every two weeks.

Do not place heavy objects on the power cord. Ensure that the power cord is not compressed.

Turn off the main power switch when not using the unit for a long period of time.

All air conditioners contain refrigerants which, under federal law, must be removed prior to disposal. If you are getting rid of an old product with refrigerants, check with the company handling disposal about what to do.

These R410A air conditioning systems require contractors and technicians to use tools, equipment and safety standards approved for use with this refrigerant.

3

SAFETY INFORMATION

Electrical Information

The power cord with this air conditioner contains a current detection device designed to reduce the risk of fire. Please refer to the section “operation of current device” for details. In the event that the power cord is damaged, it cannot be repaired. It must be replaced with a power cord from the product manufacturer.

Do not under any circumstances cut, remove, or bypass the grounding prong

Power Cord with 3-Prong Grounding Plug and Current Detection Device.

The power cord is equipped with a 3-Prong Grounding Plug which can only be used with a standard 3-prong wall outlet to minimize the possibility of electric shock hazard. Where a

2-prong outlet is encountered, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet.

Do not use a power cord that shows damage or cracks along the length or at the connector. A damaged power cord should be replaced with a new cord obtained from the manufacturer. Please contact Customer Service for replacement options.

Do not modify power cord length or share an outlet with another appliance. This may cause electric shock or fire.

Always use a dedicated power circuit. The voltage on the outlet should match the voltage rating on the rating plate.

Do not use the outlet if it is loose or damaged. It may cause electric shock.

Never use an extension cord, surge protector, or multi-outlet adapter with this unit.

Operation of Current Device

The power cord contains a current device that senses damage to the power cord. To test your power cord, do the following:

1.Plug in the Air Conditioner.

2.The power cord has TWO buttons on the 3-Prong Grounding Plug. Press the TEST button. You will notice a click as the RESET button pops out.

3.Press the RESET button, and you will hear a click as the button engages.

4.The power cord is now supplying electricity to the unit. (On some products this is also indicated by a light on the 3-Prong Grounding Plug).

NOTE:

Do not use the power cord to turn the unit on or off.

Always make sure the RESET button is pushed in for correct operation.

The power cord must be replaced if it fails to reset when either the TEST button is pushed, or it cannot be reset. Please contact Customer Service.

If the power cord is damaged, then it cannot be repaired. It MUST be replaced with a new power

cord.  Please contact Customer Service.

4

INSTALLATION INSTRUCTIONS

Before You Begin

CAUTION

When handling the unit be careful to avoid cuts from any sharp metal edges and the aluminum fins on the front / rear coils.

IMPORTANT: Save these instructions for future reference.

Product failure due to any improper installation is not covered under the One Year Limited Warranty.

IMPORTANT: You MUST use the parts provided for installation as well as proper installation procedures as described in this manual when installing this Portable Air Conditioner.

WARNING

Observe all electrical governing codes and ordinances.

Do not use damaged or non-standard power cords.

Use caution during installation and maintenance.

Use proper operation to prevent electric shock, casualty and other accidents.

Proper installation is the responsibility of the installer. If not installed properly the warranty is void.

All parts described must be used with no substitutions.

Selection of Installation Location

Installing the unit in the following places can be dangerous and may cause malfunction:

1.Areas with strong heat sources, vapors, flammable or explosive gas, sulfated gas or volatile objects spread in the air.

2.Near high-frequency devices such as welding machines, medical equipment, etc.

Requirements for Electric Connection

Follow the Electric Safety Information when installing the unit.

According to your local safety regulations, use a qualified power circuit.

Do not plug into an outlet if it is loose or damaged. It may cause electric shock.

Please make sure the power supply complies with the requirement of air conditioner. Unstable power supply or wrong wiring may lead to electric shock, hazard or malfunction. Note: Electricity requirements are 115V (60 Hz).

Do not connect to the power outlet before finishing installation.

Please make sure the outlet is always grounded effectively, otherwise it may cause electric shock. The grounding resistance should comply with national electric safety regulations.

5

INSTALLATION INSTRUCTIONS

Where to Install the Unit

• Ensure there is no obstruction near the air-inlet or air-outlet.

• This unit is for indoor use only.

• This unit must be positioned so that the plug is accessible.

• Reserved space around the air conditioner should be at least 12" (30 cm), see image.

• Place air conditioner on a level and flat surface for operation

12"

(30 cm)

 

and avoid inclining or tipping the unit.

 

 

 

 

 

This unit is equipped with casters.

 

 

 

 

 

 

 

 

Do not place unit on an elevated surface.

 

 

 

 

cm) (30 12"

12" (30 cm)

NOTE:

The description for below installation is for the standard vertical double hung / horizontal sliding window.

If you need to install the air conditioner in an over sized window, you may need to use the Extension Panel and Adjustment Panel. Please refer to requirement of window size for details and Installation Instructions.

All parts must be secured to firm wood, masonry, or metal.

The electrical outlet must be within reach of the power cord.

NOTICE:

This picture is for reference only. Please refer to the actual product for the appearance.

6

INSTALLATION INSTRUCTIONS

Unit Overview

1

 

 

 

 

1

Control Display

 

 

2

 

2

Horizontal Louver

 

 

 

 

 

 

3

 

 

Adjustment

 

 

 

 

Vertical Louver

 

 

 

 

3

 

 

 

 

 

Adjustment

 

 

 

 

4

Caster

 

 

 

 

5

Power Cord

 

 

 

 

 

Storage Hook

 

 

 

 

6

Filter Cover

 

 

4

 

7

Air-inlet

 

 

 

 

 

 

 

 

 

8

Exhaust Hose

 

 

 

 

 

Connection

 

 

11

 

9

Exhaust Hose

 

 

 

 

10

Exhaust Nozzle

 

 

 

 

11

Remote Control

 

 

 

 

 

Storage Pocket

10

9

8

6

12

Drainage Port

 

 

 

 

 

 

7

 

 

5

12

NOTICE:

This picture is for reference only. Please refer to the actual product for the appearance.

7

Gree G17-135PACSW, G17-12PACSW, G17-12PACSH User Manual

INSTALLATION INSTRUCTIONS

Parts and Tools Needed

Parts

Exhaust Hose

Exhaust Hose

Exhaust Nozzle Top

Exhaust Nozzle

Cord Hook (2)

Connection

Bottom

 

 

 

 

(May Be Pre-Assembled)

Pipe Clip

Screw (12)

Drainage Pipe

Rubber Plug

Pipe Hook (2)

Window panel

Exhaust cover

Debris Guard

Rain Guard (2)

Extension panel

Adjustment panel

Bracket

Foam Seal

(May Be Pre-Assembled)

 

 

 

 

Foam with Adhesive (2)

Drain Connector (1)

Remote Control

AAA Battery (2)

Owner's Manual

 

Tools

Phillips Head Screwdriver

Flathead Screwdriver

Saw

Tape Measure

Scissors

Pencil

8

INSTALLATION INSTRUCTIONS

Cord Hook Installation

1

Cord Hook

Screw

Install the Cord Hooks at the back of the unit with 2 screws. The top Cord Hook should face upward, and the bottom Cord Hook should face downward.

2

Wind the power cord around the Cord Hooks.

Note: Do not plug this unit in until exhaust hose is properly installed

NOTICE:

This picture is for reference only. Please refer to the actual product for the appearance.

9

Loading...
+ 20 hidden pages