Grass Valley USA, LLC and its Grass Valley Affiliates
400 Providence Mine Road
Nevada City, CA 95945
United States
15655 SW Greystone Ct.
Beaverton, OR 97006
United States
4827 HG Breda
Salt Lake City, UT 84119
Including its implementation, meets the requirements of the standard:
ISO 9001:2008
Scope:
The design, manufacture and support of video and audio hardware and software
products and related systems.
This Certificate is valid until:June 14, 2015
This Certificate is valid as of:June 14, 2012
Certified for the first time:June 14, 2000
H. Pierre Sallé
President
DEKRA Certification, Inc
The method of operation for quality certification is defined in the DEKRA General Terms
And Conditions For Quality And Environmental Management Systems Certifications.
Integral publication of this certificate is allowed.
4377 County Line Road
Chalfont, PA 18914
Ph: (215)997-4519
Fax: (215)997-3809
ANAB
Headquarters:
Kapittelweg 10
The Nederlands
2300 So. Decker Lake Blvd.
United States
DEKRA Certification, Inc.
CRT 001 042108
Accredited By:
K2 Dyno S
Replay Controller
Installation & Service Manual
Software Version 3.0
071888500
DECEMBER 2012
Contacting Grass Valley
International
Support Centers
Local Support
Centers
(available
during normal
business hours)
France
24 x 7
Australia and New Zealand: +61 1300 721 495Central/South America: +55 11 5509 3443
Middle East: +971 4 299 64 40 Near East and Africa: +800 8080 2020 or +33 1 48 25 20 20
Europe
+800 8080 2020 or +33 1 48 25 20 20
Hong Kong, Taiwan, Korea, Macau: +852 2531 3058 Indian Subcontinent: +91 22 24933476
Index ......................................................................................................................59
K2 Dyno S Replay Controller 6Installation & Service Manual
4 December 2012
Safety Summaries
Read and follow the important safety information below, noting especially those
instructions related to risk of fire, electric shock or injury to persons. Additional specific
warnings not listed here may be found throughout the manual.
WARNING: Any instructions in this manual that require opening the equipment
cover or enclosure are for use by qualified service personnel only. To
reduce the risk of electric shock, do not perform any servicing other than
that contained in the operating instructions unless you are qualified to do
so.
Safety terms and symbols
Terms in this manual
Safety-related statements may appear in this manual in the following form:
WARNING: Warning statements identify conditions or practices that may result in
personal injury or loss of life.
CAUTION: Caution statements identify conditions or practices that may result in
damage to equipment or other property, or which may cause equipment
crucial to your business environment to become temporarily
non-operational.
Terms on the product
These terms may appear on the product:
DANGER — A personal injury hazard is immediately accessible as you read the marking.
WARNING — A personal injury hazard exists but is not immediately accessible as you read
the marking.
CAUTION — A hazard to property, product, and other equipment is present.
Symbols on the product
The following symbols may appear on the product:
Indicates that dangerous high voltage is present within the equipment enclosure
that may be of sufficient magnitude to constitute a risk of electric shock.
Indicates that user, operator or service technician should refer to product
manual(s) for important operating, maintenance, or service instructions.
This is a prompt to note fuse rating when replacing fuse(s). The fuse referenced
in the text must be replaced with one having the ratings indicated.
K2 Dyno S Replay Controller 7Installation & Service Manual
4 December 2012
Safety Summaries
Warnings
The following warning statements identify conditions or practices that can result in
personal injury or loss of life.
Dangerous voltage or current may be present — Disconnect power and remove battery (if
applicable) before removing protective panels, soldering, or replacing components.
Do not service alone — Do not internally service this product unless another person capable
of rendering first aid and resuscitation is present.
Remove jewelry — Prior to servicing, remove jewelry such as rings, watches, and other
metallic objects.
Identifies a protective grounding terminal which must be connected to earth
ground prior to making any other equipment connections.
Identifies an external protective grounding terminal which may be connected to
earth ground as a supplement to an internal grounding terminal.
Indicates that static sensitive components are present which may be damaged by
electrostatic discharge. Use anti-static procedures, equipment and surfaces
during servicing.
Avoid exposed circuitry — Do not touch exposed connections, components or circuitry
when power is present.
Use proper power cord — Use only the power cord supplied or specified for this product.
Ground product — Connect the grounding conductor of the power cord to earth ground.
Operate only with covers and enclosure panels in place — Do not operate this product when
covers or enclosure panels are removed.
Use correct fuse — Use only the fuse type and rating specified for this product.
Use only in dry environment — Do not operate in wet or damp conditions.
Use only in non-explosive environment — Do not operate this product in an explosive
atmosphere.
High leakage current may be present — Earth connection of product is essential before
connecting power.
Dual power supplies may be present — Be certain to plug each power supply cord into a
separate branch circuit employing a separate service ground. Disconnect both power supply
cords prior to servicing.
Double pole neutral fusing — Disconnect mains power prior to servicing.
Use proper lift points — Do not use door latches to lift or move equipment.
Avoid mechanical hazards — Allow all rotating devices to come to a stop before servicing.
Cautions
The following caution statements identify conditions or practices that can result in damage
to equipment or other property
K2 Dyno S Replay Controller 8Installation & Service Manual
4 December 2012
Safety Summaries
Use correct power source — Do not operate this product from a power source that applies
more than the voltage specified for the product.
Use correct voltage setting — If this product lacks auto-ranging power supplies, before
applying power ensure that the each power supply is set to match the power source.
Provide proper ventilation — To prevent product overheating, provide equipment
ventilation in accordance with installation instructions.
Use anti-static procedures — Static sensitive components are present which may be
damaged by electrostatic discharge. Use anti-static procedures, equipment and surfaces
during servicing.
Do not operate with suspected equipment failure — If you suspect product damage or
equipment failure, have the equipment inspected by qualified service personnel.
Ensure mains disconnect — If mains switch is not provided, the power cord(s) of this
equipment provide the means of disconnection. The socket outlet must be installed near the
equipment and must be easily accessible. Verify that all mains power is disconnected
before installing or removing power supplies and/or options.
Route cable properly — Route power cords and other cables so that they ar not likely to be
damaged. Properly support heavy cable bundles to avoid connector damage.
Use correct power supply cor ds — Power cords for this equipment, if provided, meet all
North American electrical codes. Operation of this equipment at voltages exceeding 130
VAC requires power supply cords which comply with NEMA configurations. International
power cords, if provided, have the approval of the country of use.
Use correct replacement battery — This product may contain batteries. To reduce the risk
of explosion, check polarity and replace only with the same or equivalent type
recommended by manufacturer. Dispose of used batteries according to the manufacturer’s
instructions.
Troubleshoot only to board level — Circuit boards in this product are densely populated
with surface mount technology (SMT) components and application specific integrated
circuits (ASICS). As a result, circuit board repair at the component level is very difficult in
the field, if not impossible. For warranty compliance, do not troubleshoot systems beyond
the board level.
K2 Dyno S Replay Controller 9Installation & Service Manual
4 December 2012
Safety Summaries
Sicherheit – Überblick
Lesen und befolgen Sie die wichtigen Sicherheitsinformationen dieses Abschnitts.
Beachten Sie insbesondere die Anweisungen bezüglich
Brand-, Stromschlag- und Verletzungsgefahren. Weitere spezifische, hier nicht aufgeführte
Warnungen finden Sie im gesamten Handbuch.
WARNUNG: Alle Anweisungen in diesem Handbuch, die das
Abnehmen der Geräteabdeckung oder des Gerätegehäuses erfordern,
dürfen nur von qualifiziertem Servicepersonal ausgeführt werden. Um
die Stromschlaggefahr zu verringern, führen Sie keine
Wartungsarbeiten außer den in den Bedienungsanleitungen genannten
Arbeiten aus, es sei denn, Sie besitzen die entsprechende
Qualifikationen für diese Arbeiten.
Sicherheit – Begriffe und Symbole
In diesem Handbuch verwendete Begriffe
Sicherheitsrelevante Hinweise können in diesem Handbuch in der folgenden Form
auftauchen:
WARNUNG: Warnungen weisen auf Situationen oder Vorgehensweisen hin,
die Verletzungs- oder Lebensgefahr bergen.
VORSICHT: Vorsichtshinweise weisen auf Situationen oder
Vorgehensweisen hin, die zu Schäden an Ausrüstungskomponenten oder
anderen Gegenständen oder zum zeitweisen Ausfall wichtiger Komponenten
in der Arbeitsumgebung führen können.
Hinweise am Produkt
Die folgenden Hinweise können sich am Produkt befinden:
GEFAHR – Wenn Sie diesen Begriff lesen, besteht ein unmittelbares Verletzungsrisiko.
WARNUNG – Wenn Sie diesen Begriff lesen, besteht ein mittelbares Verletzungsrisiko.
VORSICHT – Es besteht ein Risiko für Objekte in der Umgebung, den Mixer selbst oder
andere Ausrüstungskomponenten.
Symbole am Produkt
Die folgenden Symbole können sich am Produkt befinden:
Weist auf eine gefährliche Hochspannung im Gerätegehäuse hin, die stark genug
sein kann, um eine Stromschlaggefahr darzustellen.
Weist darauf hin, dass der Benutzer, Bediener oder Servicetechniker wichtige
Bedienungs-, Wartungs- oder Serviceanweisungen in den Produkthandbüchern
lesen sollte.
Dies ist eine Aufforderung, beim Wechsel von Sicherungen auf deren Nennwert
zu achten. Die im Text angegebene Sicherung muss durch eine Sicherung ersetzt
werden, die die angegebenen Nennwerte besitzt.
K2 Dyno S Replay Controller 10Installation & Service Manual
4 December 2012
Safety Summaries
Warnungen
Die folgenden Warnungen weisen auf Bedingungen oder Vorgehensweisen hin, die
Verletzungs- oder Lebensgefahr bergen:
Gefährliche Spannungen oder Ströme – Schalten Sie den Strom ab, und entfernen Sie ggf.
die Batterie, bevor sie Schutzabdeckungen abnehmen, löten oder Komponenten
austauschen.
Servicearbeiten nicht alleine ausführen – Führen Sie interne Servicearbeiten nur aus, wenn
eine weitere Person anwesend ist, die erste Hilfe leisten und Wiederbelebungsmaßnahmen
einleiten kann.
Weist auf eine Schutzerdungsklemme hin, die mit dem Erdungskontakt
verbunden werden muss, bevor weitere Ausrüstungskomponenten
angeschlossen werden.
Weist auf eine externe Schutzerdungsklemme hin, die als Ergänzung zu einem
internen Erdungskontakt an die Erde angeschlossen werden kann.
Weist darauf hin, dass es statisch empfindliche Komponenten gibt, die durch
eine elektrostatische Entladung beschädigt werden können. Verwenden Sie
antistatische Prozeduren, Ausrüstung und Oberflächen während der Wartung.
Schmuck abnehmen – Legen Sie vor Servicearbeiten Schmuck wie Ringe, Uhren und
andere metallische Objekte ab.
Keine offen liegenden Leiter berühren – Berühren Sie bei eingeschalteter Stromzufuhr keine
offen liegenden Leitungen, Komponenten oder Schaltungen.
Richtiges Netzkabel verwenden – Verwenden Sie nur das mitgelieferte Netzkabel oder ein
Netzkabel, das den Spezifikationen für dieses Produkt entspricht.
Gerät erden – Schließen Sie den Erdleiter des Netzkabels an den Erdungskontakt an.
Gerät nur mit angebrachten Abdeckungen u nd Gehäuseseiten betreiben – Schalten Sie
dieses Gerät nicht ein, wenn die Abdeckungen oder Gehäuseseiten entfernt wurden.
Richtige Sicherung verwenden – Verwenden Sie nur Sicherungen, deren Typ und Nennwert
den Spezifikationen für dieses Produkt entsprechen.
Gerät nur in trockener Umgebung verwenden – Betreiben Sie das Gerät nicht in nassen oder
feuchten Umgebungen.
Gerät nur verwenden, wenn keine Explosionsgefahr besteht – Verwenden Sie dieses Produkt
nur in Umgebungen, in denen keinerlei Explosionsgefahr besteht.
Hohe Kriechströme – Das Gerät muss vor dem Einschalten unbedingt geerdet werden.
Doppelte Spannungsversorgung kann vorhand en sein – Schließen Sie die beiden
Anschlußkabel an getrennte Strom kreise an. Vor Servicearbeiten sind beide Anschlußkabel
vom Netz zu trennen.
Zweipolige, neutrale Sicherung – Schalten Sie den Netzstrom ab, bevor Sie mit den
Servicearbeiten beginnen.
Fassen Sie das Gerät beim Transport richtig an – Halten Sie das Gerät beim Transport nicht
an Türen oder anderen beweglichen Teilen fest.
K2 Dyno S Replay Controller 11Installation & Service Manual
4 December 2012
Safety Summaries
Gefahr durch mechanische Teile – Warten Sie, bis der Lüfter vollständig zum Halt
gekommen ist, bevor Sie mit den Servicearbeiten beginnen.
Vorsicht
Die folgenden Vorsichtshinweise weisen auf Bedingungen oder Vorgehensweisen hin, die
zu Schäden an Ausrüstungskomponenten oder anderen Gegenständen führen können:
Gerät nicht öffnen – Durch das unbefugte Öffnen wird die Garantie ungültig.
Richtige Spannungsquelle verwenden – Betreiben Sie das Gerät nicht an einer
Spannungsquelle, die eine höhere Spannung liefert als in den Spezifikationen für dieses
Produkt angegeben.
Gerät ausreichend belüften – Um eine Überhitzung des Geräts zu vermeiden, müssen die
Ausrüstungskomponenten entsprechend den Installationsanweisungen belüftet werden.
Legen Sie kein Papier unter das Gerät. Es könnte die Belüftung behindern. Platzieren Sie
das Gerät auf einer ebenen Oberfläche.
Antistatische Vorkehrungen treffen – Es gibt statisch empfindliche Komponenten, die durch
eine elektrostatische Entladung beschädigt werden können. Verwenden Sie antistatische
Prozeduren, Ausrüstung und Oberflächen während der Wartung.
CF-Karte nicht mit einem PC verwenden – Die CF-Karte ist speziell formatiert. Die auf der
CF-Karte gespeicherte Software könnte gelöscht werden.
Gerät nicht bei eventuellem Ausrüstungsfehler betreiben – Wenn Sie einen Produktschaden
oder Ausrüstungsfehler vermuten, lassen Sie die Komponente von einem qualifizierten
Servicetechniker untersuchen.
Kabel richtig verlegen – Verlegen Sie Netzkabel und andere Kabel so, dass Sie nicht
beschädigt werden. Stützen Sie schwere Kabelbündel ordnungsgemäß ab, damit die
Anschlüsse nicht beschädigt werden.
Richtige Netzkabel verwenden – Wenn Netzkabel mitgeliefe rt wurden, erfüllen diese alle
nationalen elektrischen Normen. Der Betrieb dieses Geräts mit Spannungen über 130 V AC
erfordert Netzkabel, die NEMA-Konfigurationen entsprechen. Wenn internationale
Netzkabel mitgeliefert wurden, sind diese für das Verwendungsland zugelassen.
Richtige Ersatzbatterie verwenden – Dieses Gerät enthält eine Batterie. Um die
Explosionsgefahr zu verringern, prüfen Sie die Polarität und tauschen die Batterie nur
gegen eine Batterie desselben Typs oder eines gleichwertigen, vom Hersteller empfohlenen
Typs aus. Entsorgen Sie gebrauchte Batterien entsprechend den Anweisungen des
Batterieherstellers.
Das Gerät enthält keine Teile, die vom Benutzer gewartet werden können. Wenden Sie sich
bei Problemen bitte an den nächsten Händler.
K2 Dyno S Replay Controller 12Installation & Service Manual
4 December 2012
Safety Summaries
Consignes desécurité
Il est recommandé de lire, de bien comprendre et surtout de respecter les informations
relatives à la sécurité qui sont exposées ci-après, notamment les consignes destinées à
prévenir les risques d’incendie, les décharges électriques et les blessures aux personnes.
Les avertissements complémentaires, qui ne sont pas nécessairement repris ci-dessous,
mais présents dans toutes les sections du manuel, sont également à prendre en
considération.
AVERTISSEMENT: Toutes les instructions présentes dans ce manuel qui
concernent l’ouverture des capots ou des logements de cet équipement sont
destinées exclusivement à des membres qualifiés du personnel de
maintenance. Afin de diminuer les risques de décharges électriques, ne
procédez à aucune intervention d’entretien autre que celles contenues dans le
manuel de l’utilisateur, à moins que vous ne soyez habilité pour le faire.
Consignes et symboles de sécurité
Termes utilisés dans ce manuel
Les consignes de sécurité présentées dans ce manuel peuvent apparaître sous les formes
suivantes :
AVERTISSEMENT: Les avertissements signalent des conditions ou des
pratiques susceptibles d’occasionner des blessures graves, voire même fatales.
MISE EN GARDE: Les mises en garde signalent des conditions ou des
pratiques susceptibles d’occasionner un endommagement à l’équipement ou
aux installations, ou de rendre l’équipement temporairement non
opérationnel, ce qui peut porter préjudice à vos activités.
Signalétique apposée sur le produit
La signalétique suivante peut être apposée sur le produit :
DANGER — risque de danger imminent pour l’utilisateur.
AVERTISSEMENT — Risque de danger non imminent pour l’utilisateur.
MISE EN GARDE — Risque d’endommagement du produit, des installations ou des autres
équipements.
K2 Dyno S Replay Controller 13Installation & Service Manual
4 December 2012
Safety Summaries
Symboles apposés sur le produit
Les symboles suivants peut être apposés sur le produit :
Signale la présence d’une tension élevée et dangereuse dans le boîtier de
l’équipement ; cette tension peut être suffisante pour constituer un risque de
décharge électrique.
Signale que l’utilisateur, l’opérateur ou le technicien de maintenance doit faire
référence au(x) manuel(s) pour prendre connaissance des instructions
d’utilisation, de maintenance ou d’entretien.
Il s’agit d’une invite à prendre note du calibre du fusible lors du remplacement
de ce dernier. Le fusible auquel il est fait référence dans le texte doit être
remplacé par un fusible du même calibre.
Identifie une borne de protection de mise à la masse qui doit être raccordée
correctement avant de procéder au raccordement des autres équipements.
I dentifie une borne de protection de mise à la masse qui peut être connectée en
tant que borne de mise à la masse supplémentaire.
Signale la présence de composants sensibles à l’électricité statique et qui sont
susceptibles d’être endommagés par une décharge électrostatique. Utilisez des
procédures, des équipements et des surfaces antistatiques durant les
interventions d’entretien.
Avertissements
Les avertissements suivants signalent des conditions ou des pratiques susceptibles
d’occasionner des blessures graves, voire même fatales :
Présence possible de tensions ou de courants dangereux — Mettez hors tension,
débranchez et retirez la pile (le cas échéant) avant de déposer les couvercles de protection,
de défaire une soudure ou de remplacer des composants.
Ne procédez pas seul à une intervention d’entretien — Ne réalisez pas une intervention
d’entretien interne sur ce produit si une personne n’est pas présente pour fournir les
premiers soins en cas d’accident.
Retirez tous vos bijoux — Avant de procéder à une interven tion d’entretien, retirez tous vos
bijoux, notamment les bagues, la montre ou tout autre objet métallique.
Évitez tout contact avec les circuits exposés — Évitez tout contact avec les connexions, les
composants ou les circuits exposés s’ils sont sous tension.
Utilisez le cordon d’alimentation approprié — Utilisez exclusivement le cordon
d’alimentation fourni avec ce produit ou spécifié pour ce produit.
Raccordez le produit à la masse — Raccordez le conducteur de masse du cordon
d’alimentation à la borne de masse de la prise secteur.
Utilisez le produit lorsque les couvercles et les capots sont en place — N’utilisez pas ce
produit si les couvercles et les capots sont déposés.
Utilisez le bon fusible — Utilisez exclusivement un fusible du type et du calibre spécifiés
pour ce produit.
K2 Dyno S Replay Controller 14Installation & Service Manual
4 December 2012
Safety Summaries
Utilisez ce produit exclusivement dans un environnement sec — N’utilisez pas ce produit
dans un environnement humide.
Utilisez ce produit exclusivement dans un environnement non explosible — N’utilisez pas ce
produit dans un environnement dont l’atmosphère est explosible.
Présence possible de courants de fuite — Un raccordement à la masse est indispensable
avant la mise sous tension.
Deux alimentations peuvent être présentes dans l’équipement — Assurez vous que chaque
cordon d’alimentation est raccordé à des circuits de terre séparés. Débranchez les deux
cordons d’alimentation avant toute intervention.
Fusion neutre bipolaire — Débranchez l’alimentation principale avant de procéder à une
intervention d’entretien.
Utilisez les points de levage appropriés — Ne pas utiliser les verrous de la porte pour lever
ou déplacer l’équipement.
Évitez les dangers mécaniques — Laissez le ventilateur s’arrêter avant de procéder à une
intervention d’entretien.
Mises en garde
Les mises en garde suivantes signalent les conditions et les pratiques susceptibles
d’occasionner des endommagements à l’équipement et aux installations :
N’ouvrez pas l’appareil — Toute ouverture prohibée de l’appareil aura pour effet d’annuler
la garantie.
Utilisez la source d’alimentation adéquate — Ne branchez pas ce produit à une source
d’alimentation qui utilise une tension supérieure à la tension nominale spécifiée pour ce
produit.
Assurez une ventilation adéquate — Pour éviter toute surchauffe du produit, assurez une
ventilation de l’équipement conformément aux instructions d’installation. Ne déposez
aucun document sous l’appareil – ils peuvent gêner la ventilation. Placez l’appareil sur une
surface plane.
Utilisez des procédures antistatiques - Les composants sensibles à l’électricité statique
présents dans l’équipement sont susceptibles d’être endommagés par une décharge
électrostatique. Utilisez des procédures, des équipements et des surfaces antistatiques
durant les interventions d’entretien.
N’utilisez pas la carte CF avec un PC — La carte CF a été spécialement formatée. Le logiciel
enregistré sur la carte CF risque d’être effacé.
N’utilisez pas l’équipement si un dysfonctionnement est suspecté — Si vous suspectez un
dysfonctionnement du produit, faites inspecter celui-ci par un membre qualifié du
personnel d’entretien.
Acheminez les câbles correctement — Acheminez les câbles d’alimentation et les autres
câbles de manière à ce qu’ils ne risquent pas d’être endommagés. Supportez correctement
les enroulements de câbles afin de ne pas endommager les connecteurs.
Utilisez les cordons d’alimentation adéquats — Les cordons d’alimentation de cet
équipement, s’ils sont fournis, satisfont aux exigences de toutes les réglementations
régionales. L’utilisation de cet équipement à des tensions dépassant les 130 V en c.a.
K2 Dyno S Replay Controller 15Installation & Service Manual
4 December 2012
Safety Summaries
requiert des cordons d’alimentation qui satisfont aux exigences des configurations NEMA.
Les cordons internationaux, s’ils sont fournis, ont reçu l’approbation du pays dans lequel
l’équipement est utilisé.
Utilisez une pile de remplacement adéquate — Ce produit renferme une pile. Pour réduire le
risque d’explosion, vérifiez la polarité et ne remplacez la pile que par une pile du même
type, recommandée par le fabricant. Mettez les piles usagées au rebut conformément aux
instructions du fabricant des piles.
Cette unité ne contient aucune partie qui peut faire l’objet d’un entretien par l’utilisateur.
Si un problème survient, veuillez contacter votre distributeur local.
K2 Dyno S Replay Controller 16Installation & Service Manual
4 December 2012
Certifications and compliances
Canadian certified power cords
Canadian approval includes the products and power cords appropriate for use in the North
America power network. All other power cords supplied are approved for the country of
use.
FCC emission control
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the user will be required to correct
the interference at his own expense. Changes or modifications not expressly approved by
Grass Valley can affect emission compliance and could void the user’s authority to operate
this equipment.
Canadian EMC Notice of Compliance
This digital apparatus does not exceed the Class A limits for radio noise emissions from
digital apparatus set out in the Radio Interference Regulations of the Canadian Department
of Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites
applicables aux appareils numériques de la classe A préscrites dans le Règlement sur le
brouillage radioélectrique édicté par le ministère des Communications du Canada.
EN55103 1/2 Class A warning
This product has been evaluated for Electromagnetic Compatibility under the EN 55103-1/
2 standards for Emissions and Immunity and meets the requirements for E4 environment.
This product complies with Class A (E4 environment). In a domestic environment this
product may cause radio interference in which case the user may be required to take
adequate measures.
FCC emission limits
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesirable
operation.
Laser compliance
Laser safety requirements
This product may contain a Class 1 certified laser device. Operating this product outside
specifications or altering its original design may result in hazardous radiation exposure, and
may be considered an act of modifying or new manufacturing of a laser product under U.S.
regulations contained in 21CFR Chapter 1, subchapter J or CENELEC regulations in HD
K2 Dyno S Replay Controller 17Installation & Service Manual
4 December 2012
Certifications and compliances
482 S1. People performing such an act are required by law to recertify and reidentify this
product in accordance with provisions of 21CFR subchapter J for distribution within the
U.S.A., and in accordance with CENELEC HD 482 S1 for distribution within countries
using the IEC 825 standard.
Laser safety
Laser safety in the United States is regulated by the Center for Devices and Radiological
Health (CDRH). The laser safety regulations are published in the “Laser Product
Performance Standard,” Code of Federal Regulation (CFR), Title 21, Subchapter J.
The International Electrotechnical Commission (IEC) Standard 825, “Radiation of Laser
Products, Equipment Classification, Requirements and User’s Guide,” governs laser
products outside the United States. Europe and member nations of the European Free Trade
Association fall under the jurisdiction of the Comité Européen de Normalization
Electrotechnique (CENELEC).
Safety certification
This product has been evaluated and meets the following Safety Certification Standards:
StandardDesigned/tested for compliance with:
ANSI/UL 60950-1Safety of Information Technology Equipment, including
Electrical Business Equipment (Second edition 2007).
IEC 60950-1 with CB
cert.
CAN/CSA C22.2 No.
60950-1
BS EN 60950-1Safety of Information Technology Equipment, including
Safety of Information Technology Equipment, including
Electrical Business Equipment (Second edition, 2005).
Safety of Information Technology Equipment, including
Electrical Business Equipment (Second edition 2007).
Electrical Business Equipment 2006.
K2 Dyno S Replay Controller 18Installation & Service Manual
4 December 2012
ESD Protection
Electronics today are more susceptible to electrostatic discharge (ESD) damage than older
equipment. Damage to equipment can occur by ESD fields that are smaller than you can
feel. Implementing the information in this section will help you protect the investment that
you have made in purchasing Grass Valley equipment. This section contains Grass Valley’s
recommended ESD guidelines that should be followed when handling electrostatic
discharge sensitive (ESDS) items. These minimal recommendations are based on the
information in the
Requirements for Personnel” on page 20 is provided to assist you in selecting an
appropriate grounding method.
Recommended ESD Guidelines
Follow these guidelines when handling Grass Valley equipment:
• Only trained personnel that are connected to a grounding system should handle ESDS
items.
• Do not open any protective bag, box, or special shipping packaging until you have
been grounded.
Note: When a Personal Grounding strap is unavailable, as an absolute minimum,
touch a metal object that is touching the floor (for example, a table, frame, or
rack) to discharge any static energy before touching an ESDS item
“Sources of ESD and Risks” area. The information in “Grounding
• Open the anti-static packaging by slitting any existing adhesive tapes. Do not tear the
tapes off.
• Remove the ESDS item by holding it by its edges or by a metal panel.
• Do not touch the components of an ESDS item unless it is absolutely necessary to
configure or repair the item.
• Keep the ESDS work area clear of all nonessential items such as coffee cups, pens,
wrappers and personal items as these items can discharge static. If you need to set an
ESDS item down, place it on an anti-static mat or on the anti-static packaging.
Sources of ESD and Risks
The following information identifies possible sources of electrostatic discharge and can be
used to help establish an ESD policy.
Personnel
One of the largest sources of static is personnel. The static can be released from a person’s
clothing and shoes.
Environment
The environment includes the humidity and floors in a work area. The humidity level must
be controlled and should not be allowed to fluctuate over a broad range. Relative humidity
(RH) is a major part in determining the level of static that is being generated. For example,
at 10% - 20% RH a person walking across a carpeted floor can develop 35kV; yet when the
relative humidity is increased to 70% - 80%, the person can only generate 1.5kV.
K2 Dyno S Replay Controller 19Installation & Service Manual
4 December 2012
ESD Protection
Static is generated as personnel move (or as equipment is moved) across a floor’s surface.
Carpeted and waxed vinyl floors contribute to static build up.
Work Surfaces
Painted or vinyl-covered tables, chairs, conveyor belts, racks, carts, anodized surfaces,
Plexiglas covers, and shelving are all static generators.
Equipment
Any equipment commonly found in an ESD work area, such as solder guns, heat guns,
blowers, etc., should be grounded.
Materials
Plastic work holders, foam, plastic tote boxes, pens, packaging containers and other items
commonly found at workstations can generate static electricity.
Grounding Requirements for Personnel
The information in this section is provided to assist you in selecting a grounding method.
This information is taken from ANSI/ESD S20.20-2007 (Revision of ANSI/ESD
S20.20-1999).
Product Qualification
Personnel Grounding
Technical Requirement
Wrist Strap System*ANSI/ESD S1.1 (Section 5.11)< 3.5 x 107 ohm
Flooring / Footwear System –
Method 1
Flooring / Footwear System –
Method 2 (both required)
Product qualification is normally conducted during the initial selection of ESD control
products and materials. Any of the following methods can be used: product specification
review, independent laboratory evaluation, or internal laboratory evaluation.
Compliance Verification
Personnel Grounding
Technical Requirement
Wrist Strap System*ESD TR53 Wrist Strap Section< 3.5 x 107 ohm
Flooring / Footwear System –
Method 1
Flooring / Footwear System –
Method 2 (both required)
Test MethodRequired Limits
ANSI/ESD STM97.1< 3.5 x 107 ohm
ANSI/ESD STM97.1< 109 ohm
ANSI/ESD STM97.2< 100 V
Test MethodRequired Limits
ESD TR53 Flooring Section and
ESD TR53 Footwear Section
ESD TR53 Flooring Section and
ESD TR53 Footwear Section
< 3.5 x 107 ohm
< 1.0 x 109 ohm
* For situations where an ESD garment is used as part of the wrist strap grounding path, the
total system resistance, including the person, garment, and grounding cord, must be less
7
than 3.5 x 10
K2 Dyno S Replay Controller 20Installation & Service Manual
4 December 2012
ohm.
Chapter 1
Product description
About this manual
This Installation & Service manual provides procedures for installing and servicing the
Dyno S Replay Controller to the field-replaceable unit level. Use this manual to
K2
perform an initial installation, isolate problems to a board or module, and to make repairs
through module exchange.
Introduction
The K2 Dyno S Replay Controller is a compact slow-motion controller designed for sports
and other live event production. It features a touch-screen interface, and plays using
industry standard files. It connects to video server (K2 Summit Production Client, K2 Solo
Media Server, or K2 SAN) for media storage. The Dyno
environment using standard Gigabit Ethernet networks for file sharing.
The Dyno S Controller provides a variety of features including speed, editing, effects,
multi-user operation, an efficient user interface, and immediate content packaging.
Interface tools include thumbnail icons, status indicators, specialized windows, and
drag-and-drop operations for speedy and easy use.
Refer to the K2 Dyno S Replay Controller User Manual for descriptions of features,
controls, applications, and subsystems.
S Controller supports a networked
WARNING: The Dyno S Controller power standby switch does not turn off power to
the system. To turn power off the system must be disconnected from the
power source.
System overview
A Dyno S Controller can be shipped as part of a Dyno-Pack, that includes a K2 Summit as
part of the package, or it can be shipped stand alone for connection to a separately acquired
K2 Summit, Solo, or SAN system.
K2 Dyno S Replay Controller 21Installation & Service Manual
4 December 2012
Chapter 1 Product descriptionDyno-Pack System
K2 Summit 3G Client
K2 Dyno S Replay Controller
Ethernet
connection
Video/audio
monitoring
SDI in (A)
C1
SDI out (C)
SDI out (D)
C3
Record
Play
C4
SDI in (B)
C2
AppCenter Pro
on K2 Summit
Production Client
K2 Dyno S Replay
application
computer output
P1
PGM
P2
PVW
Dyno-Pack System
A Dyno-Pack system consists of a K2 Summit, a Dyno S Controller, video and audio
cabling and monitoring, and system communications interconnections
.
K2 Dyno S Replay Controller 22Installation & Service Manual
4 December 2012
Chapter 1 Product descriptionDyno S Controller and K2 Solo Media Server System
K2 Solo
K2 Dyno S Replay Controller
Ethernet
connection
Video/audio
monitoring
SDI in
C1
SDI out
C2
Record
Play
AppCenter Pro
on K2 Summit
Production Client
K2 Dyno S Replay
application
computer output
Dyno S Controller and K2 Solo Media Server System
A Dyno S Controller can also operate with the smaller K2 Solo Server. A typical
configuration has one channel input and one channel output.
K2 Summit/Solo system requirements
To support connection to a K2 Dyno S Replay Controller, your K2 Summit Production
Client or K2 Solo Media Server must meet requirements as follows. Refer to compatibility
information in release notes for complete and updated requirements.
• K2 Summit Production Client with internal storage, direct-connect storage, or shared
K2 SAN storage.
• All K2 Summit systems controlled by a Dyno S Controller on a K2 SAN must have
their timecode synchronized to house timecode
• Depending on media formats required, a K2 Summit Production Client must have
appropriate licenses and/or hardware installed.
• The version of K2 system software must be compatible with the version of Dyno S
Controller software. Refer to release notes.
• AppCenter Pro license is required. On K2 Solo Media Server, the license is standard.
On K2 Summit Production Client, the license must be installed, if not already present.
• If using ChannelFlex Suite features, the K2 Summit Production Client or K2 Solo
Media Server requirements are as follows:
• Compatible K2 system software
• AppCenter Elite license
• Super Slo-Mo also requires the HD license
K2 Dyno S Replay Controller 23Installation & Service Manual
4 December 2012
Chapter 1 Product descriptionDyno S Controller and K2 SAN System
K2 Summit 3G Client
K2 Summit 3G Client
K2 Dyno S Replay Controller
K2 Dyno S Replay Controller
AppCenter Pro
on K2 Summit
Production Client
K2 Summit 3G Client
K2 Dyno S Replay
application
computer output
K2 Dyno S Replay
application
computer output
Dyno S Controller and K2 SAN System
Dyno S Controllers can also operate with a K2 SAN system. A typical system is shown, but
many different configurations are possible.
K2 Dyno S Replay Controller 24Installation & Service Manual
4 December 2012
Chapter 1 Product descriptionDyno S Controller general specifications
Dyno S Controller general specifications
CharacteristicSpecification
Power100 - 240 VAC, 50 - 60 Hz, and 2.5A
DimensionsDimensions: length = 15.1 in. (383 mm);
width = 10.0 in. (254 mm); height = 6.4 in.(64 mm) (All approx.)
Weight4.75 kg (10.5 lbs.)
Temperature rangeOperating: 0°C to 40°C (32°F to 104°F); Storage: -20°C to 60°C
(-4°F to 140°F)
Humidity range10% to 90% (relative humidity)
Fuse (internal)1.1A 20V Self Resetting - This fuse is mounted on the CPU
Carrier board, on the 12V rail, and is intended to prevent over
current to the LCD Panel. While this fuse is installed, it is not
used with the currently approved LCD panel on the K2 Dyno S.
K2 Dyno S Replay Controller 25Installation & Service Manual
4 December 2012
Chapter 1 Product descriptionDyno S Controller general specifications
K2 Dyno S Replay Controller 26Installation & Service Manual
4 December 2012
Chapter 2
Dyno S Controller Installation
This section explains installation of the K2 Dyno S Replay Controller, which operates in
conjunction with a K2 system. Refer to the separate K2 documentation set for specific
installation information about the K2 Summit, K2 Solo, or K2 SAN.
Unpack and check Dyno S Controller contents
Find the following items in the packaging for the Dyno S Controller.
ItemDescription
K2 Dyno S Replay Controller
Power Cord
Recovery Flash Drive (stored on rear panel) which contains:
-Software and disk images.
-Dyno S Documentation
Keyboard and Mouse
DisplayPort to DVI Adapter (passive)
Licenses and Warranties
NOTE: Do not lose the Recovery Flash Drive. It contains the recovery disk image for
this specific K2 Dyno
S system.
K2 Dyno S Replay Controller 27Installation & Service Manual
4 December 2012
Chapter 2 Dyno S Controller InstallationGather additional items
Power Cord
Power
Standby
Ethernet
(control)
Keyboard
Mouse
8681_02
Stereo
Audio Out
(1/8 in.)
DisplayPort
(use adapter if connecting
to a DVI or VGA monitor)
Gather additional items
To complete a typical K2 Dyno S Replay System, as referenced in this Quick Start Guide,
you must provide the following items:
• Two computer monitors (1280 x 1024 x 32 or greater) and cables. The Summit has a
VGA connector, and the Dyno has DisplayPort connectors.
• Ethernet cables, either crossover or straight-through.
• USB keyboard and mouse, for use with Summit.
• Video monitors and cables, or if equipped with the App Center Pro license the Summit
computer monitor can be used to monitor video in and out.
• Audio monitoring (headphones or speakers).
System cabling
Cable Dyno S Controller
Make Dyno S Controller cable connections as illustrated.
The Ethernet connection between the K2 Summit Client and the Dyno S Controller can be
via direct connect cable or via an Ethernet switch.
K2 Dyno S Replay Controller 28Installation & Service Manual
4 December 2012
Chapter 2 Dyno S Controller InstallationCable K2 Summit 3G Client
Channels (C1, C2, C3, C4) are bi-directional
Use C1 as record
channel. Connect
C1 SDI in 1
Use C2 as record
channel. Connect
C2 SDI in 1
Use C3 as play
channel. Connect
C3 SDI out 1
Use C4 as play
channel. Connect
C4 SDI out 1
Power
cord
Power
cord
Reference
Loop
AES audio
(1 for each
channel)
Keyboard
and mouse
(2 USB)
VGA
monitor
Ethernet control
connection
Optional:
Ethernet media
(FTP) connection
Power
cord
Keyboard
and mouse
VGA
monitor
Ethernet
control
connection
Optional:
Ethernet
media (FTP)
connection
Channels (C1, C2) are bi-directional
Use C1 as record
channel. Connect
SDI in
Use C2 as
play channel.
Connect SDI out
AES
audio
Cable K2 Summit 3G Client
For a K2 Summit Client system, a typical basic installation can use the cable connections
as illustrated.
NOTE: For Ethernet control, use the lower left port (as viewed from the rear).
If a ChannelFlex option is present, additional cabling options are available.
For complete cabling instructions, refer to the K2 System Guide.
Cable K2 Solo
A K2 Solo system is essentially half of a K2 Summit, with two bidirectional channels. A
typical installation for use with a Dyno S Controller are illustrated.
If a ChannelFlex option is present, additional cabling options are available.
For complete cabling instructions, refer to the K2 System Guide.
NOTE: For Ethernet control, use the lower left port (as viewed from the rear).
SDI IN2 SDI IN3SDI IN1 SDI IN2 SDI IN3
SDI IN1SDI OUT1 SDI OUT2
AES AUDIORS422
C1
LTC I /O
USB/1394
100-240 V4-2A,
60-50Hz
SDI OUT1 SDI OUT2
AES AUDIORS422
100BT/1000BT
VGA
GPI
LTC I /O
C2
REF. LOOP THROUGH
K2 Dyno S Replay Controller 29Installation & Service Manual
4 December 2012
Chapter 2 Dyno S Controller InstallationChannelFlex option
SDI IN1SDI OUT1 SDI OUT2
LTC I/O
AES AUDIORS422
SDI IN2 SDI IN3
Phase 1Phase 2Phase 3
Super Slo-Mo Recorder
SDI IN1SDI OUT1 SDI OUT2
LTC I/O
AES AUDIORS422
SDI IN2 SDI IN3
Video 1Video 2
Multi-Cam Recorder
SDI IN1SDI OUT1 SDI OUT2
LTC I/O
AES AUDIORS422
SDI IN2 SDI IN3
Video or
Left eye
Key or
Right eye
3D/Video + Key Recorder
SDI IN1SDIOUT1 SDI OUT2
LTC I/O
AES AUDIORS422
SDI IN2 SDI IN3
Video or
Left eye
Key or
Right eye
3D/Video + Key Player
ChannelFlex option
A variety of cabling options are available when ChannelFlex is available.
For complete cabling instructions, refer to the K2 System Guide.
Software installation
Dyno S Controllers are shipped from the factory with the current software version installed.
No software installation is required. However, the version of software running on the
S Controller must be compatible with the software running on the K2 system it will
Dyno
connect to.
For version compatibility information, and for Dyno S Controller software update
procedures, refer to the appropriate version of the K2 Dyno Controller Release Notes.
System startup
Start up K2 system
1. Press the Standby button on the K2 frame to activate the unit.
2. Power up the computer monitor connected to the K2 system.
3. Log on to the K2 system with the default Windows administrator account:
• Username: Administrator
• Password: adminGV! (The password is case sensitive)
K2 Dyno S Replay Controller 30Installation & Service Manual
4 December 2012
4. At first startup, End User License Agreements appear on the K2 system screen.
Accept the agreements to continue.
The Power LED goes on and stays on. The Service LED stays off. Startup processes
complete in approximately two minutes and the K2 system is ready for connection and
operation.
Chapter 2 Dyno S Controller InstallationStart up Dyno S Controller
Start up Dyno S Controller
1. Press the Standby button on the rear of the Dyno S Controller to activate the unit.
Press
Standby
8681_04
2. Power up the computer monitor connected to the Dyno S Controller. The Dyno S
Controller does not require a login, and by default will boot to the Dyno UI screen.
If the network configuration is correct, you can follow the standard startup procedures to
connect to the K2 system.
3. Select a Server on the list, or touch Add Server and type the name of the Server.
4. Select Connect or Reconnect.
Default IP Network Configuration
The K2 Dyno S Replay Controller IP network addressing is configured differently,
depending on whether it ships stand alone, or ships paired with a K2 Summit as a
Dyno-Pack.
Stand alone
A stand alone Dyno S Controller is configured by default to use DHCP. This permits
automatic connection to a network that is running a DHCP network address server.
Dyno-Pack Default IP Addresses
A Dyno-Pack, consisting of a Dyno S Controller paired with a K2 Summit (3G)/Solo(3G),
ships with static IP network addressing
DeviceDefault Static IP AddressSubnet
Dyno S Controller
K2 Summit
Configure to facility network
The Dyno-Pack default IP addresses will work if the K2 Summit and Dyno S Controller
operate on an isolated network. These values will probably need to be changed to be
compatible with your facility’s existing network.
192.168.40.155 255.255.255.0
192.168.40.156255.255.255.0
Use standard Windows operating system procedures on both the K2 Summit and the
S Controller to configure each with a static IP address on the same subnet. You can
Dyno
also configure a host name if desired.
K2 Dyno S Replay Controller 31Installation & Service Manual
4 December 2012
Chapter 2 Dyno S Controller InstallationLAN connector indicator codes
Green/Yellow/Orange
Green
LAN connector indicator codes
The motherboard of the Dyno S Controller has two RJ-45 LAN connectors that include
integrated status LEDs. The LEDs are oriented as follows:
Configure K2 system channels
The K2 system channels may need to be configured for your required formats and
resolutions. This example uses a four channel K2 Summit.
1. If necessary, open AppCenter, either by clicking on its icon on the desktop or selecting
the application in the Windows Start menu.
2. Logon to the AppCenter application with the administrator account. If a licensing
message appears, refer to K2 Release Notes.
The default K2 administrator account is the same as the Windows logon:
• Username: Administrator
• Password: adminGV! (The password is case sensitive)
3. Click System / Configuration.The Configuration System pane appears.
The Configuration menus have tabs, scrollbars, dropdown lists, and buttons that are
used to navigate to and choose various settings (video input format, video output
format, audio, etc.). For this initial setting four Player Recorder channels will be
configured.
K2 Dyno S Replay Controller 32Installation & Service Manual
4 December 2012
Chapter 2 Dyno S Controller InstallationMonitor K2 system video channels
4. Click Channel, select the C1 tab, ensure the Player/Recorder type is selected, and then
scroll down and make video and audio settings as appropriate for your input and
output.
5. Repeat the above step for tabs C2, C3, and C4 so that all four channels are set to
Player/Recorder with appropriate settings.
6. Click OK to exit the Configuration menu.
Selecting which channels will be used for recording and playback is accomplished when a
Dyno session is created.
If using ChannelFlex™ features, refer to the K2 AppCenter User Manual.
Monitor K2 system video channels
Record and playback video can be viewed on the K2 Summit computer monitor, or can be
viewed using external video monitors.
K2 system computer display monitoring
On the VGA monitor connected to the K2 Summit Client, you can monitor fou r video
channels. This requires an AppCenter Pro or Elite license. Switching between views can be
accomplished in two ways.
K2 Dyno S Replay Controller 33Installation & Service Manual
4 December 2012
Chapter 2 Dyno S Controller InstallationExternal video monitors
• In AppCenter, click View/Video Monitor to display multi-view video.
• Alternatively, at any time you can double-click on a monitor area in the multi-view or
control screen to switch between views.
External video monitors
Using a facility routing system or video DAs, route duplicates of the K2 Summit video
inputs and outputs to external monitors.
K2 Dyno S Replay Controller 34Installation & Service Manual
4 December 2012
Chapter 3
Service procedures
Initial troubleshooting
If you think there is something wrong with your K2 Dyno S Replay Controller, perform the
following initial troubleshooting steps:
1. Check configurations
• Many times what appears to be a K2 Dyno S Replay Controller fault is actually an
easy-to-fix configuration problem. Check settings in the K2 Summit Production
Client Configuration Manager and the Dyno Replay application Config tab and
verify that the system is configured as you expect.
2. Check software versions.
• The K2 server and Dyno controller must be running compatible software versions.
Confirm that the software versions match those indicated in the Release Notes.
3. Check connections and external equipment
• Loose or improperly connected cables are the most likely source of problems for
the system. A quick check of all the cable connections can easily solve these
problems. Refer to the troubleshooting topic
page 39 if you suspect a failure in a connected device.
“Checking external equipment” on
4. Isolate functional problems. See “Isolating functional problems” on page 35
5. Run hardware diagnostics. See “Hardware diagnostics” on page 37
Isolating functional problems
If you have a problem with a particular function but you are not sure of the source of a
problem, do the following:
1. Verify that you can view functions on the following components. Connect or power up
as appropriate:
• The Dyno controller control panel (buttons, T-bar lever, jog knob)
• The Dyno controller integrated touch screen
• The external computer display connected to the Dyno controller
• The computer display connected to the K2 Summit Production Client.
2. Compare functions between components. Determine if the problem appears on some
components but not other components.
K2 Dyno S Replay Controller 35Installation & Service Manual
4 December 2012
Chapter 3 Service proceduresAbout Dyno Controller modes
3. Use the following table to isolate the problem.
If the problem appears on these components…It indicates the cause and corrective actions are as follows:
Dyno
Panel
xFaulty control panel. Replace control panel UI board.
xxFaulty software. Reimage Dyno.
xxxFaulty software or motherboard. Reimage Dyno. If problem
xxxxFaulty network connection or video/audio feed. Check
Dyno Touch
Screen
xFaulty software or LCD touch screen. Reimage Dyno. If
xFaulty computer display connection or monitor. Check
Dyno Ext.
Display 2
xAn active DisplayPort adapter is required when using two
Summit
Display
remains, replace motherboard.
network and video/audio source.
problem remains, replace LCD screen
connections and monitor. If using a DVI or VGA monitor,
check DisplayPort adapter.
External displays. Two passive adapters (like the one
provided) will not work. Use a passive and active DisplayPort
adapter, or two active DisplayPort adapters.
The Dyno Controller operates in the following modes:
• Dyno mode – The Dyno application is automatically launched at startup.
• Maintenance mode – The Dyno application is closed and the Windows operating
system desktop is available for system tasks such as network configuration, software
update, and determining Windows Operating System version.
By default, the K2 Dyno Replay Controller is in the Dyno mode. You must manually put
the unit in the maintenance mode, which requires a restart.
Access maintenance mode
1. Touch the HOME or CONFIG tab on the touchscreen to access one of these screens.
2. Press the Dyno Controller SHIFT button and then touch Exit on the touchscreen.
3. Touch the Shutdown Mode button to select Maintenance.
K2 Dyno S Replay Controller 36Installation & Service Manual
4 December 2012
Chapter 3 Service proceduresLaunch Dyno application from maintenance mode
4. Touch Restart to go to the Windows OS desktop.
Launch Dyno application from maintenance mode
When in maintenance mode, you can relaunch the Dyno application by double touching the
Dyno Replay Controller icon on the desktop.
Hardware diagnostics
The K2 Dyno S Replay Controller has a built-in hardware diagnostics tool available for
testing hardware.
To run the hardware diagnostics, you need to start up the K2 Dyno S Replay Controller in
Maintenance mode. With the K2 Dyno S Replay Controller diagnostics, you can check if
the hardware is operating normally as to whether:
• the buttons are illuminated in corresponding colors
• the T-Bar position information is correct
• the hardware responds to the JOG operations properly
• the touch panel detects correct positions
1. While in a regular Dyno software session, touch Config | Exit and select the option for
Maintenance mode.
The Windows desktop displays.
K2 Dyno S Replay Controller 37Installation & Service Manual
4 December 2012
Chapter 3 Service proceduresSystem startup, shutdown problems
2. Go to Windows Start and select Dyno Diagnostic Tool (S). The Diagnostics
screen appears.
3. Perform hardware operation checks.
NOTE: Any changes made in the diagnostics, such as button brightness changes, will
be disabled when you exit the diagnostics.Changes, such as brightness
changes and lever position adjustments, must be made in a calibration.
4. When finished, click the Exit button at the lower right side.
5. When you exit the diagnostics, you are returned to the Windows desktop. To re-start
the Dyno software, click on the Dyno icon on the desktop.
System startup, shutdown problems
Windows startup
After the BIOS startup processes complete the Windows operating system starts up.
Normally the Windows operating system completes its processes automatically without the
need to press keys or respond to messages.
If the Windows startup screen does not proceed automatically or if a message appears that
requires your input, it indicates a problem at the operating system level. If the problem
cannot be corrected with a supported procedure (such as networking), the Windows
operating system is not operating as it should. To correct problems of this nature, restore
the system drive image. Refer to
“Using recovery disk images” on page 40.
K2 Dyno S Replay Controller 38Installation & Service Manual
4 December 2012
Chapter 3 Service proceduresSystem shutdown
System shutdown
If the K2 Dyno S Replay Controller is inoperable due to a software error it can affect the
operation of the standby button. If pressing the power button does not shut down the K2
Dyno S Replay Controller, press and hold the button for eight seconds. This forces the K2
Dyno S Replay Controller to execute a hard power down. If that doesn’t work, disconnect
the power cable.
Checking external equipment
This section provides troubleshooting procedures for external devices that connect to the
K2 Dyno S Replay Controller. Before using these procedures, first check connections, as
“Check connections and external equipment” on page 35.
in
Keyboard and mouse problems
The keyboard and mouse are detected during BIOS startup. There should be a very brief
message displayed indicating detection of input devices connected to USB ports
ProblemPossible CausesCorrective Actions
The K2 Dyno S Replay
Controller does not respond
correctly when one or more of
the keys on the keyboard are
pressed or the mouse is used.
The keyboard or mouse is faulty.Replace the keyboard or mouse.
K2 Dyno S Replay Controller
system settings have been
tampered with.
Restore default settings by
restoring the system drive image
from a recent backup image.
Checking Dyno components
LCD touch screen problems
ProblemPossible CausesCorrective Actions
Screen turns on, but nothing
from K2 Dyno S Replay
Controller is displayed
K2 Dyno S Replay Controller
system settings have been
tampered with.
Internal connector or LCD touch
screen is faulty.
Restore default settings by
restoring the system drive image
from a recent backup image.
Replace Top Assembly.
K2 Dyno S Replay Controller 39Installation & Service Manual
4 December 2012
Chapter 3 Service proceduresThermal problems
Thermal problems
ProblemPossible CausesCorrective Actions
The fans are noisy or otherwise
run erratically. The K2 Dyno S
Replay Controller overheats.
This can be accompanied by a
message indicating a
temperature or fan problem.
Airflow is blocked.Ensure adequate airflow around
the K2 Dyno S Replay
Controller.
A fan is not operating correctly. Listen/look at the chassis fan and
the power supply fan to verify
proper operation. If the fans are
not operating correctly, replace
the fan or power supply.
Power supply problems
ProblemPossible CausesCorrective Actions
The K2 Dyno S Replay
Controller will not power on or
power fails while the unit is in
operation. This can be
accompanied by a message
indicating a power supply
problem prior to the failure.
The power source is faulty.Make sure your power source is
reliable.
The power cord is faulty.Try another power cord.
The unit is too hot. The built-in
overtemperature protection can
shut down the power supply.
The power supply is faulty.Replace the power supply
Check for thermal problems.
Cool the K2 Dyno S Replay
Controller.
Using recovery disk images
About the recovery disk image process
You can create a disk image of the K2 Dyno S Replay Controller system drive and restore
from the image. This simplifies the process of rebuilding a system in a disaster-recovery
scenario.
NOTE: This process is not intended as a means to backup and restore media.
When you receive your K2 Dyno S Replay Controller new from the factory, you a receive
a system-specific disk image for that particular K2 Dyno S Replay Controller. This factory
image is stored on a bootable USB Recovery Flash Drive. Also on the Recovery Flash
Drive is the Acronis True Image software necessary to create and restore a disk image.
After your K2 Dyno S Replay Controller is installed, configured, and running in your
system environment, you should create new recovery disk images to capture settings
changed from default. These “first birthday” images are the baseline recovery image for the
K2 Dyno S Replay Controller in its life in your facility. There is enough disk space on the
Recovery Flash Drive to store the first birthday image along with the factory image.
You should likewise create a new recovery disk image after completing any process that
changes system software or data, such as a software upgrade. In this way you retain the
ability to restore your K2 Dyno S Replay Controller to a recent “last known good” state.
K2 Dyno S Replay Controller 40Installation & Service Manual
4 December 2012
Chapter 3 Service proceduresCreating a recovery disk image
NOTE: The recovery disk image process is an “off-line” process. Do not attempt this
process while media access is underway.
The recovery disk image process that you should follow is summarized in the following
steps.
At the K2 Dyno S Replay Controller first birthday…
1. Boot from the Recovery Flash Drive.
2. Create a recovery disk image for the K2 Dyno S Replay Controller.
At milestones, such as software upgrades…
1. Boot from the Recovery Flash Drive.
2. Create a recovery disk image for the K2 Dyno S Replay Controller.
3. Copy the disk image to another location, such as a network drive.
If you need to restore the K2 Dyno S Replay Controller…
1. Boot from the Recovery Flash Drive.
2. Read the disk image from the Recovery Flash Drive or from the location that you
stored the disk image.
Use the following procedures to implement the recovery disk image process as necessary.
Creating a recovery disk image
Do the following at the local K2 Dyno S Replay Controller to create a disk image:
1. Make sure that media access is stopped.
2. If you have not already done so, connect keyboard, monitor, and mouse to the K2
Dyno S Replay Controller.
3. Insert the Recovery Flash Drive into a USB port and restart the machine.
The machine boots from the Flash drive. The Acronis True Image program loads.
4. In the Acronis True Image main window, click Backup.
The Create Backup Wizard opens.
5. On the Welcome page, click Next.
The Partitions Selection page opens.
6. Select the (C:) partition and then click Next.
If a “…choose full backup mode…” message appears, click OK.
The Backup Archive Location page opens.
7. In the tree view select Removable Drive (A:) as the location to which you are writing
the disk image.
8. Enter the name of the image file you are creating. Create the file name using the K2
Dyno S Replay Controller hostname and the date. Name the file with the .tib
extension. For example, if the hostname is Dyno1, in the File name fi eld yo u wo uld
have
E:\Dyno1_20091027.tib. Click Next.
K2 Dyno S Replay Controller 41Installation & Service Manual
4 December 2012
Chapter 3 Service proceduresRestoring from a system-specific recovery disk image
The Select Backup Mode page opens.
9. Select Create a new full backup archive. Click Next.
The Backup Creation Options page opens.
10.Do not change any settings on this page. Click Next.
The Archive Comment page opens.
11. If desired, enter image comments, such as the date, time, and software versions
contained on the image you are creating. Click
The “…ready to proceed…” page opens.
12.Verify that you are creating an image from the C: drive and writing to the A:\ drive.
Proceed.
Click
If a “…insert next volume…” message appears, click OK.
The Operation Progress page opens and displays progress.
13. When a “Backup archive creation has been successfully completed” message
appears, click
14.Click Operations | Exit to exit the Acronis True Image program.
The K2 Dyno S Replay Controller restarts automatically.
OK.
Next.
15.Remove the Recovery Flash Drive while the K2 Dyno S Replay Controller is shutting
down.
Restoring from a system-specific recovery disk image
Use this procedure to access an image created from a specific system and restore that image
to the same specific system from which it was created. This can be the factory image stored
on the bootable USB Recovery Flash Drive or an image you created to capture settings
changed from default.
Before restoring from a recovery disk image, make sure that the K2 Dyno S Replay
Controller has access to the image from which you are restoring. You can restore from an
image on the Recovery Flash Drive, from a network connected drive, or from another
connected USB drive.
1. Make sure that media access is stopped.
2. If you have not already done so, connect keyboard, monitor, and mouse to the K2
Dyno S Replay Controller.
3. Insert the Recovery Flash Drive in a USB port and restart the machine. If there is a
problem restarting, hold the standby button down for eight seconds to force a hard
shutdown. Then press the standby button again to startup.
The machine boots from the Flash drive. The Acronis True Image program loads.
4. In the Acronis True Image main window, click Recovery.
The Restore Data Wizard opens.
5. On the Welcome page, click Next.
The Archive Selection page opens.
6. In the tree view do one of the following:
K2 Dyno S Replay Controller 42Installation & Service Manual
4 December 2012
Chapter 3 Service proceduresRestoring from a generic recovery disk image
• Expand the node for Removable Drive (A:). This is the Recovery Flash Drive. Select
the image file. The file for the image supplied by the Grass Valley factory is named
with the serial number of the K2 Dyno S Replay Controller.
• Navigate to the location of the image file from which you are restoring.
An image file has a .tib file name extension.
7. Click Next:
The Restoration Type Selection page opens.
8. Select Restore disks or partitions and then click Next.
The Partition or Disk to Restore page opens.
9. Select FAT32 (C:) and then click Next.
The Restored Partition Location page opens.
10.Select FAT32 (C:) and then click Next.
The Restored Partition Type page opens.
11. Leave the selection at Active and then click Next.
The Restored Partition File System page opens.
12.Select FAT32 and then click Next.
The Restored Partition Size page opens.
13.Leave settings at their defaults. The size reported in the upper pane is the size
detected of the actual C: partition. This should be the same as that reported in the
Partition size field in the middle of the page. Free space before and Free space after
should both be reported at 0 bytes. Click
The Next Selection page opens.
14.Select No, I do not and then click Next.
The Restoration Options page opens.
15.Do not change any settings on this page. Click Next.
16.Click Proceed.
The Operation Progress page opens and displays progress.
17. When a “The data was successfully restored” message appears, click OK.
18.Click Operations | Exit to exit the Acronis True Image program.
The K2 Dyno S Replay Controller restarts automatically.
19.Remove the Recovery Flash Drive while the K2 Dyno S Replay Controller is shutting
down.
Next.
Restoring from a generic recovery disk image
Use this procedure to restore from a generic baseline image that does not apply to any
specific system. Use this procedure only as directed by release notes or by Grass Valley
support.
1. Perform step 1 on page 42 through step 19 above to restore the K2 Dyno S Replay
Controller to a generic image.
K2 Dyno S Replay Controller 43Installation & Service Manual
4 December 2012
Chapter 3 Service proceduresReplacing a K2 Dyno S Replay Controller
2. When restart completes, you are prompted to rename the computer. Enter a name for
the K2 Dyno Replay Controller and click
The name assigned by default by the factory is the serial number of the unit.
3. Set NIC names as follows:
- Set rear panel Ethernet port 1 to GB1
- Set rear panel Ethernet port 2 to GB2
4. Install Dyno Client software as instructed in release notes.
When installing software, if prompted to enter the serial number, leave the serial
number field blank. Do not enter the serial number.
Next.
Replacing a K2 Dyno S Replay Controller
To correct some system faults Grass Valley Support sends you a replacement K2 Dyno S
Replay Controller. Contact Grass Valley Support if you think you need a replacement K2
Dyno S Replay Controller.
K2 Dyno S Replay Controller 44Installation & Service Manual
4 December 2012
Chapter 4
Dyno S Controller FRUs
Field Replaceable Units (FRUs) are modular hardware components that can be serviced
without disturbing other components in the system. The following topics show how to
disassemble K2 Dyno S Replay Controller FRUs. Unless otherwise documented,
re-assembly is the reverse.
WARNING: The K2 Dyno S Replay Controller power standby switch does not turn off
power to the system. To turn power off the system must be disconnected
from the power source.
WARNING: To avoid serious injury from high currents, turn off the K2 Dyno S
Replay Controller and disconnect AC power before opening the top cover
or removing any internal parts.
CAUTION: This system contains board-level components that must be protected from
static discharge and physical shock. Wear a wrist strap grounded through
one of the system's ESD Ground jacks when handling system components.
NOTE: Only Grass Valley components are supported. Do not attempt to use
components procured from a different source.
NOTE: Do not discard any hardware unless specifically instructed to do so.
K2 Dyno S Replay Controller 45Installation & Service Manual
4 December 2012
Chapter 4 Dyno S Controller FRUsFRU locations
FRU locations
The following illustration shows the location of Field Replaceable Units (FRUs) and other
components in the K2 Dyno S Replay Controller.
Top cover plastic
Top assembly
(includes UI card,
Jog knob and
T-bar assemblies)
UI card
Fan assembly
Chassis base
Power supply
T-bar lever
assembly
Jog knob
top
Jog knob
bearing
Jog knob
base
8702_01
Jog knob
assembly
K2 Dyno S Replay Controller 46Installation & Service Manual
4 December 2012
Chapter 4 Dyno S Controller FRUsFRU functional descriptions
FRU functional descriptions
Base chassis
The base chassis includes the K2 Dyno S Replay Controller product serial number, and so
cannot be replaced as a FRU. For some serious system faults or for mechanical damage, the
entire K2 Dyno S Replay Controller can be replaced.
Plastic cover
The plastic top cover provides the finished work surface with access holes for controls.
Top assembly
This assembly provides the front control panel user interface for the K2 Dyno S Replay
Controller, including the following functionality:
• LCD touch screen and controller
• CPU/Carrier
The following components, included in the Top assembly FRU, can also be replaced
separately:
• UI card
• Jog knob
•T-bar lever
Motherboard
The motherboard hosts the CPU and other components that provide the basic computer
functionality for the controller. It has rear panel connectors as follows:
• 2 Giga-bit Ethernet
• 2 USB 3.0/2.0 ports
• 4 USB 2.0 ports, and
• 2 DisplayPorts
• 1 stereo headphone jack (1/8 in.)
UI card
The UI card contains backlit, tri-color, momentary contact tactile buttons.
Jog knob assembly
The jog knob is 60mm, weighted, and rubber encased with tactile relief. This assembly
includes several parts, including the encoder bearing.
T-bar lever assembly
The T-bar level assembly is the complete mechanism which includes the front panel T-bar
lever and the unit in which it is housed.
K2 Dyno S Replay Controller 47Installation & Service Manual
4 December 2012
Chapter 4 Dyno S Controller FRUsFan
8702_05
A
B
C
D
E
F
Only remove D, E, and F
if the encoder will also be
removed.
Fan
The fan provides cooling for the K2 Dyno S Replay Controller chassis. The fan is installed
in the rear of the chassis and is temperature controlled.
Power supply
The K2 Dyno S Replay Controller power supply has protection for over voltage, over
current, over temperature, and short circuits.
Jog knob maintenance
The K2 Dyno S Replay Controller jog knob and bearings can be removed from the top
without opening the chassis. Servicing the jog knob’s internal encoder requires opening the
chassis.
Jog knob and bearing assembly removal
1. Loosen set screw. Use 2mm Allen wrench.
2. Lift off jog knob.
3. Disassemble washer and bearing components as shown.
K2 Dyno S Replay Controller 48Installation & Service Manual
4 December 2012
Chapter 4 Dyno S Controller FRUsJob knob replacement
Bearing assembly components are listed below in the correct stacking order.
IdentifierComponentNotes
AJog knob
BSmall washer
CBearing
DNutRemoving D, E, and F will
EToothed washer
FLarge wa sher
cause the encoder to loosen
and possibly fall into the
chassis.
4. Store all the components in a container to ensure parts are not misplaced.
Job knob replacement
When replacing the job knob, replace washers and bearings in the correct stacking order,
then align the knob’s set screw with the flat surface on the shaft.
Jog knob encoder removal
1. Remove jog knob and bearing assembly (see “Jog knob and bearing assembly removal”
on page 48).
2. Open chassis so the top is upside-down on the padded work surface (see “Open
chassis” on page 51).
WARNING: To avoid serious injury from high currents, turn off the K2 Dyno S
Replay Controller and disconnect AC power before opening the top cover
or removing any internal parts.
3. Identify the red encoder wire orientation, and then disconnect the cable from encoder.
8702_06
K2 Dyno S Replay Controller 49Installation & Service Manual
4 December 2012
Chapter 4 Dyno S Controller FRUsT-bar lever maintenance
4. Remove 4 locking hex nuts, using a 1/4 in. wrench, and lift the encoder out of the top
of the chassis.
T-bar lever maintenance
The K2 Dyno S Replay Controller T-bar handle can be removed from the top without
opening the chassis. Servicing the T-bar lever’s internal assembly requires opening the
chassis.
T-bar lever handle removal
1. Unscrew the small half of the handle. It turns counter-clockwise if installed on the right
(as facing the front of the panel), and clockwise if installed on the left. Only one side
can be unscrewed.
8702_07
2. Remove the exposed hex head screw. Use 1.5mm Allen wrench.
3. Lift the larger half of the handle off the arm.
NOTE: The Allen screw threads into the arm, not into the other half of the handle.
4. Place the two halves of the handle and the Allen screw into a container to ensure parts
are not misplaced.
T-bar lever assembly removal
1. Remove T-bar lever handle (see “T-bar lever handle removal” on page 50).
K2 Dyno S Replay Controller 50Installation & Service Manual
4 December 2012
Chapter 4 Dyno S Controller FRUsOpen chassis
8702_08
2. Open chassis so the top is upside-down on the padded work surface (see “Open
chassis” on page 51).
WARNING: To avoid serious injury from high currents, turn off the K2 Dyno S
Replay Controller and disconnect AC power before opening the top cover
or removing any internal parts.
3. Remove cable from T-bar assembly.
4. Remove 4 locking hex nuts, using a 1/4 in. wrench, and lift out the T-bar assembly.
Open chassis
The K2 Dyno S Replay Controller chassis can be opened to access internal hardware.
WARNING: To avoid serious injury from high currents, turn off the K2 Dyno S
Replay Controller and disconnect AC power before opening the top cover
or removing any internal parts.
1. Turn off the unit and unplug the unit’s AC power cord.
2. Place padding or a cloth onto the work surface to protect the top surface of the unit.
K2 Dyno S Replay Controller 51Installation & Service Manual
4 December 2012
Chapter 4 Dyno S Controller FRUsOpen chassis
8702_03
3. Remove 14 bottom and rear screws, using a T15 Torx.
8702_02
4. Lift and turn over the chassis base.
K2 Dyno S Replay Controller 52Installation & Service Manual
4 December 2012
Chapter 4 Dyno S Controller FRUsClose chassis
Close chassis
When replacing the top, install the two center top (A) and two center side (B) screws first,
and then replace the remaining screws in any order.
A
B
B
A
8702_04
Fan removal
1. Open chassis so the top is upside-down on the padded work surface (see “Open chassis”
on page 51).
WARNING: To avoid serious injury from high currents, turn off the K2 Dyno S
Replay Controller and disconnect AC power before opening the top cover
or removing any internal parts.
K2 Dyno S Replay Controller 53Installation & Service Manual
4 December 2012
Chapter 4 Dyno S Controller FRUsFan removal
8702_09
2. Disconnect fan cable from inside the top of the chassis, cutting tie wraps as needed.
3. Remove the 4 screws (#2 Phillips) and the fan screen from the outside rear of the
chassis bottom.
8702_10
4. Remove fan from inside chassis.
K2 Dyno S Replay Controller 54Installation & Service Manual
4 December 2012
Chapter 4 Dyno S Controller FRUsPower supply removal
Power supply removal
1. Open chassis (see “Open chassis” on page 51).
WARNING: To avoid serious injury from high currents, turn off the K2 Dyno S
Replay Controller and disconnect AC power before opening the top cover
or removing any internal parts.
2. Disconnect 3 power cables from the power supply.
8702_11
3. Remove 4 screws, using a T15 Torx, and then lift out the power supply.
UI board removal
1. Open chassis so the top is upside-down on the padded work surface (see “Open chassis”
on page 51).
WARNING: To avoid serious injury from high currents, turn off the K2 Dyno S
Replay Controller and disconnect AC power before opening the top cover
or removing any internal parts.
2. Disconnect the UI board power cable (A) and T-bar assembly cable (B) from the UI
K2 Dyno S Replay Controller 55Installation & Service Manual
4 December 2012
Chapter 4 Dyno S Controller FRUsUI board removal
8702_12
board.
A
8702_12
B
C
3. Identify the orientation of the red wire on the jog knob encoder cable (C), and then
disconnect the cable from the UI board.
4. Remove 13 screws, using a T15 Torx, and then lift the UI board out of the chassis top.
K2 Dyno S Replay Controller 56Installation & Service Manual
4 December 2012
Chapter 4 Dyno S Controller FRUsPlastic cover removal
8702_14
Plastic cover removal
1. Remove jog knob and bearing assembly and T-Bar handle (see individual instructions).
2. Open chassis so the top is upside-down on the padded work surface (see “Open
chassis” on page 51).
WARNING: To avoid serious injury from high currents, turn off the K2 Dyno S
Replay Controller and disconnect AC power before opening the top cover
or removing any internal parts.
3. Remove 8 screws, using a T15 Torx.
4. Lift the top assembly out of the plastic top.
K2 Dyno S Replay Controller 57Installation & Service Manual
4 December 2012
Chapter 4 Dyno S Controller FRUsPlastic cover removal
K2 Dyno S Replay Controller 58Installation & Service Manual
4 December 2012