Charge:85mA x 16hrs at 20°C
(with Sleeve)
Overcharge
Range
: Rechargeable Nickel Metal
Hydride Cylindrical Cell
= 10.5mm
H = 44.5mm
Recommended discharge current
85 to 2550mA
: 1.2V
Rated: 850mAh
Typical:900mAh
When discharged at 170mA to
1.0V at 20℃
: 85mA for 16 hrs at 20℃
: 80% of rated capacity after cell storage
at 20℃ for 12 months
When discharged at 170mA to 1.0V at
20℃
425mA to 850mA (0.5 to 1C)
charge termination control
recommended control parameters:
-V
DT/dt :
TCO :
Timer : 105% nominal input
: >500 cycles (IEC standard)
: 85mA maximum current for 1 year.
No conspicuous deformation and/or
leakage
: 14.5g
Average 40m upon fully charged
(Max. 60m) at 1000Hz
: 1.5V at 85mA charging
Standard Charge : 0 to 45℃
Fast Charging : 10 to 45℃
Discharge : -20 to 50℃
Storage : -20 to 35℃
: 0-5mV
0.8℃/min (0.5 to 0.9C)
0.8 - 1℃/min (1C)
45 - 50℃
(for ref. only)
Model No
Low Rate Discharge
1.5
1.4
1.3
1.2
1.1
1
Voltage (V)
0.9
0.8
0.7
High Rate Discharge
1.5
1.4
1.3
1.2
1.1
1
Voltage (V)
0.9
0.8
0.7
425mA
0 2 4 6 8 10 12 14
2550mA
0 10 20 30 40 50 60 70
170mA
Discharge Time (Hrs)
Charge: 85mA x 16hrs at 20°C
(3C)
1700mA
(2C)
Discharge Time (Mins)
85mA
850mA
(1C)
www.gpbatteries.com
Manufacturer reserves the right to alter or amend the design, model and specification without prior notice.
Copyright@GPI International Ltd. – All rights reserved
The information (subject to change without prior notice) contained in this
document is for reference only and should not be used as a basis for product
guarantee or warranty. For applications other than those described here,
please consult your nearest GP Sales and Marketing Office or Distributors.
TRS0340 rev.18