Gp batteries GPZA675 DATASHEET

Product Specifications Model No.:GPZA675
Document Number: ZA0004 Revision:02 Page 1 of 5
1. APPLICABILITY
This specification is applicable to GP Zinc Air GPZA675.
2.1 Type designation : PR44(IEC/JIS) / 7003ZD(ANSI)
2.2 Nominal voltage : 1.4V
2.3 Shape and dimension
2.4 Typical Capacity
2.5 Typical weight
2.6 Warranty period : 12 months
2.7 Date code : Unless otherwise specified, every battery will carry an expiry
: Refer to Drawing 1. : 620mAh (continuous discharge under 620 to 0.9V at 20°C
: 1.8g
date code for 36 months. (e.g. a battery manufactured on January 2009 will carry an expiry code of 01-12.)
3. APPEARANCE
There shall be no dirt, scratch or deformation detrimental to practical service in appearance.
4. CELL VOLTAGE
4.1 Test method l Method of sampling : MIL-STD-105E level II single sampling normal inspection.
Voltmeter : Digital Voltmeter (DVM) with the precision of 1mV (internal resistance
not less than 1 Megohm)
Test temperature
4.2 Off Load Voltage
At shipping 12 months after manufactured
*1.36V to 1.46V *1.36V to 1.46V
4.3 On Load Voltage
*Above 1.3V *Above 1.3V
Load resistance : 620 ± 0.5% (measure time : 0.8 seconds)
: 20±2°C
Initial 12 months after manufactured
*Take away the tape on battery and wait for 15 minutes before measure Voltage.
Product Specifications Model No.:GPZA675
Document Number: ZA0004 Revision:02 Page 2 of 5
5. SERVICE OUTPUT
5.1 Test method (1) The resistance of external discharge circuit shall be as specified plus or minus 0.5%. (2) The duration of discharge time periods shall be as specified plus or minus 1%. (3) Storage shall be at 20±2°C, 65±20%RH and discharge tests shall be at 20±2°C, 65±20%RH.
5.2 Service Life
Test Mode Application Initial
(Nominal)
Service
life at
20±2°C
M: minute H: hour EPV: end point voltage
*The initial discharge test shall commence within 30 days of manufacture. During this period, the cells shall be stored under room temperature conditions. (20±2°C and 65±20% relative humidity) **Take away the tape on battery and wait for 15 minutes before measure Service Life.
620continuous (EPV=0.9V)
Reference test 247H 225H 153H
Initial
(Minimum)
12 months storage at
20°C
(Nominal)
6. ELECTROLYTE LEAKAGE
6.1 Leakage on arrival at warehouse.
Leakage shall be checked with naked eye. No leakage shall be observed with the naked eye; and no bulging
exceeding the maximum dimensions shall result.
6.2 Leakage at room temperature
After storing for 12 months at 20 ±15°C, 65±20%RH, no leakage shall be observed with the naked eye; and no
bulging exceeding the maximum dimensions shall result.
6.3 Leakage at high temperature
Within thirty days of manufacture, the cell shall be stored for 30 days at 45±2°C and below 70% relative
humidity, no leakage shall be observed with the naked eye; and no bulging exceeding the maximum dimensions shall result.
6.4 Leakage of over discharge
After loading with 620 continuously down to 0.8V at 20±2°C, 65±20%RH, no leakage shall be observed with
the naked eye; and no bulging exceeding the maximum dimensions shall result.
Loading...