Gossen Mavospot User Manual

Operating Instructions

MAVO-SPOT

With Measuring Angle 1 Degree For Measuring Luminance from the Distance Attachment for MAVO-MONITOR 15167 1/7-04
Lens with protective filter or close-up lens and stray light shield
Eye-piece with eye-cup
On/Off switch Battery check
Battery compartment 2
MAVO-SPOT
1 Applications........................................... 2
2 The functioning of the MAVO-SPOT... 2
2.1 Inserting the Battery................................ 2
2.2 Battery Check......................................... 2
3 Using the MAVO-SPOT........................ 2
3.1 Preparations........................................... 2
3.2 Measuring............................................... 2
4 Accessories........................................... 2
4.1 Standard equipment................................ 2
4.2 Optional accessories............................... 3
4.3 Calibration Certificate.............................. 3
5 Servicing and Repairs.......................... 3
Connection cable
6 Technical data....................................... 3
Declaration of conformity.................... 4
Warning: Do not aim the MAVO-SPOT at the sun. You would risk damaging your eye and also the light sensor
may be destroyed!!
GOSSEN Foto- und Lichtmesstechnik GmbH
1

1 Applications

The MAVO-SPOT attached to the measuring instrument MAVO-MONITOR provides high precision measurements with a measuring angle of 1 degree.
The combined set permits measuring the luminance, non- contact, at distances from 1 m to .The MAVO-SPOT is equipped with SLR (single lens reflex) optics having a viewing area of 15° and a clearly defined 1 degree measuring circle in the centre. Two close-up lenses available as optional accessories permit reducing the measuring distance down to 34 cm. The light sensor is color corrected, i.e. its spectral responsitivity is matched to the spectral photopic vision of the human eye (V λ ), acc. to DIN 5032, Part 7, Class B. The combined set is especially suited for measuring:
Monitors, while taking into account the ambient light, e.g. inspection and constancy tests at medical imaging systems, acc. to DIN 6868-57 and IEC 61223-2-5
(QS-RL dt. Nov. 20, 2003)
Lighting of streets, tunnels, airports
Lighting of sports areas
Light contrast at work stations ( Protection Laws and Regulations)
Lighting in museums
Projection screens (Checking the uniformity of illumination)

2 The Functioning of the MAVO-SPOT

2.1 Inserting the Battery

The battery compartment is located at the front of the grip of the unit. Slide the cover of the compartment downward, insert the battery and attach the connector clip to the new battery. Then insert battery in the compartment.
Attention: Only use new batteries or rechargeable accus according to IEC 6 LF 22.

2.2 Battery Control

When the instrument is switched on the green LED on the right of the ON/OFF switch lights up. When the battery is exhausted the red LED at the left of the ON/OFF switch will light up. You should then replace the battery immediately. A new alkaline-manganese battery will last for approx. 60 hours of continuous measurement operation.

3 Using the MAVO-SPOT

3.1 Prepairing the measurement

Screw the protective filter, supplied with the instrument, or one of the close-up lenses on the lens of the MAVO-SPOT. For For getting correct measurement values, either protective filter or one of the close-up lenses must be placed on the lens, but please note: one item only – either the filter or one of the lenses. Pull the stray light shield out. Use the attached cable to connect the MAVO-SPOT with the MAVO-MONITOR. Switch both units on and select a suitable measuring range.

3.2 Measuring

View through the eye-piece of the SLR viewfinder of the MAVO-SPOTand direct the measuring circle, you see in the viewfinder to the area to be measured. This area should be illuminated uniformly and be as large as possible as compared to the measuring circle. Press the key HOLD (Display Hold) at The MAVO-MONITOR and read the value measured.

4 Accessories

4.1 Standard equipment

Battery
Instruction Manual
Protective filter
GOSSEN Foto- und Lichtmesstechnik GmbH
2

4.2 Optional accessories

Close-up lenses: the MAVO-Spot with the protective filter (standard equipment) placed in front of the lens allows
measuring from distances from 1 m to . For shorter distances two close-up lenses are available.
Close-up lens 1 (Ordering No. M496G): Reduces the measuring distance down to approx. 51 cm to 1 m
Close-up lens 2 (Ordering No. M496G): Reduces the measuring distance down to approx. 34 to 51 cm
Attention: Take care that allways the protective filter or one of the close-up lenses must be placed in front of the lens, but one item only. Incorrect measurement values will result, if you attach more than the one filter or more than one close-up lens.
Transport Case (Ordering No. M495G): for storing and transporting the complete set of MAVO-SPOT plus MAVO-MONITOR and also the two close-up lenses, the USB cable and spare batteries.
4.3 Calibration Certificate (Optional)
Calibration reference: Scientific Standard Lamp, type Wi 41G of the PTB (Physikalische Technische Bundesanstalt Braunschweig – National Standard Institute of Germany). Depending on how the instrument is being used we recommend a recalibration interval between 12 and 18 months. For this purpose please contact our Calibration Service Department (telephone +49 911 8602 172).

5 Servicing and Repairs

No special maintenance is required, if the MAVO-SPOT is handled correctly. Keep the outside surfaces clean. Use a slightly dampened cloth for cleaning. Do not use cleansers, abrasives or solvents. Should the instrument nevertheless not work to your satisfaction or if you will require repeated calibration with Test Certificate, please send the MAVO-SPOT to:
GOSSEN Foto- und Lichtmesstechnik GmbH Thomas-Mann-Strasse 16 – 20 D – 90471 Nürnberg

6 Technical data Light Sensor Silicon photo diode with V(λ) filter acc. To DIN 5032 Part 7 (CIE 69) Measuring Angle ε1/10 = 1° Measuring Range 0,01 cd/m2 to 20 000 cd/m2, Measurung Accuracy the same as indicated for the MAVO-MONITOR

Power Supply 9 V IEC 6 F 22 battery, Accu IEC 6 LF
Battery life approx. 60 hours of continuous measuring
Cable Lentgh approx. 1 m Dimensions 200 x 90 x 55 mm Weight 375 g (without battery) Electromagnetic Compatibility (EMC)
The MAVO-SPOT fully meets the Specifications 89/336/EWG dt. Jan. 01, 1996
GOSSEN Foto- und Lichtmesstechnik GmbH
3

DECLARATION OF CONFORMITY

EG - KONFORMITÄTSERKLÄRUNG
Dokument-Nr./ Document.No.: 104/2004 Hersteller/ Manufacturer: GOSSEN Foto- und Lichtmesstechnik GmbH
Anschrift / Address: Thomas-Mann-Str.16-20
Produktbezeichnung/ Product name: Leuchtdichtevorsatz zur Distanzmessung Typ / Type: MAVO-SPOT
Bestell-Nr / Order No: M494G Das bezeichnete Produkt stimmt mit den Vorschriften folgender Europäischer Richtlinien überein, nachgewiesen durch die vollständige Einhaltung folgender Normen:
The above mentioned product has been manufactured according to the regulations of the following European directives proven through complete compliance with the following standards: Nr. / No. Richtlinie Directive 73/23/EWG
73/23/EEC
EN/Norm/Standard IEC/Deutsche Norm VDE-Klassifikation/Classification EN 61010-1 : 1993 EN 61557-3 : 1997
Nr. / No. Richtlinie Directive 89/336/EWG 89/336/EEC
Fachgrundform / Generic Standard: EN 61326 : 2002 Nürnberg, den 03. Januar 2002
___________________________________________________ _____________________________________
Ort, Datum / Place, date: Vorsitzender der Geschäftsführung
Diese Erklärung bescheinigt die Übereinstimmung mit den genannten Richtlinien, This declaration certifies compliance with the above mentioned beinhaltet jedoch keine Zusicherung von Eigenschaften. Die Sicherheitshinweise directives but does not include a property assurance. The safety der mitgelieferten Produktdokumentationen sind zu beachten. notes given in the product documentations which are part of the supply, must be observed.
Elektrische Betriebsmittel zur Verwendung innerhalb bestimmter Spannungsgrenzen
- Niederspannungsrichtlinie –Anbringung der CE-Kennzeichnung : 2003
IEC 61010-1 : 1992 IEC 61557-3 : 1997
Elektromagnetische Verträglichkeit
- EMV - Richtlinie
90471 Nürnberg
For Measuring Luminance from the Distance
Electrical equipment for use within certain voltage limits
- Low Voltage Directive ­Attachment of CE mark : 2003
VDE 0411-1 : 1994 VDE 0413-3 : 1997
Electromagnetic compatibility
-EMC directive
Gossen Foto- und Lichtmesstechnik GmbH is also a leading provider for other interesting light measuring instrumemts:
-MAVOLUX 5032 C USB: Digital precision instrument for measuring the illuminance in lx or fc, classified acc. to DIN 5032, Part 7 and CIE 69 in Class C. Ideally suited for use in industry, trade, institutes and inspection authorities, also for very high light intensities.
-MAVOLUX 5032 B USB: Digital precision instrument for measuring the illumenance in lx or fc, classified acc. to DIN 5032, Part 7 and CIE 69 in Class B. Especially wide measuring range and high sensitivity for inspection and certification, suited for checking emergency lighting, but also for very high light intensities.
-MAVO-MAX: For monitoring the ambient light in the surroundings of monitors according to the IEC 61223-2-5 (QS-RL dt. 20/11/2003). The use of the MAVO-MAX allows extending the required repeat test intervalls of the „veil luminance“ and the „maximum contrast“ at medical imaging displays – to six month.
Printed in Germany – Subject to change witout notice
GOSSEN Foto- und Lichtmesstechnik GmbH Thomas-Mann-Str.16-20 90471 Nürnberg Phone : +49 911 8602-181 Fax: : +49 911 8602-142 e-mail: info@gossen-photo.de
GOSSEN Foto- und Lichtmesstechnik GmbH
4