Gorenje KGV 200-1, KGV 300-2, KGV 300-1 User Manual

Page 1
KGV 200 - 300
Page 2
29
Dear customer, thank you for purchasing our product.
PLEASE READ THE INSTRUCTIONS CAREFULLY PRIOR TO THE INSTALLATION AND FIRST USE OF THE WATER HEATER.
The hot water tank is designed in a manner which allows using the following heating sources, via heat exchanger:
central heating hot-water system
solar power
heating pump.
Electric
heater type R may be additionally installed on the flange 180mm, or electric heater type
SH to the connecting bushing G 6/4.
INSTALLATION
TECHNICAL CHARACTERISTICS
KGV 200-1 KGV 300-1 KGV 300-2 A 1150 1550 1550 B
560 740 740 C 380 560 560 D - - 930 E - - 360 F 1010 1410 1410
HV G 1 G 1 G 1
IM G 1 G 1 G 1 CV G 3/4 G 3/4 G 3/4 VM G 1 G 1 G 1 TV G 1 G 1 G 1
KGV 200-1 KGV 300-1 KGV 300-2 H1 300 480 480 H2 - - 300
h1 100 155 155 h2 - - 210
H1, H2 - Canal for palps h1, h2 - Position of palps
HV - Cold water inflow
(blue
rosette) IM - HE medium outlet (blue rosette) CV - Circulation conduit (blue rosette) VM - HE medium inflow (red rosette) TV - Cold water outflow (red rosette)
GB
Page 3
30
Type KGV 200-1 KGV 300-1 KGV 300-2 Volume [l] 200 285 280 Rated pressure [MPa ] 0,6 W
eight / Filled with water
[kg] 82 / 282 112 / 397
134 / 414 Anti-corrosion protection of tank Enameled/Mg Anode HE heated surface - lowe [m
2
] 0,85 1,45 1,45
HE heated surface - upper [m
2
] - - 0,90 HE volume - lower [l] 5,3 9,1 9,1 HE volume - upper [l] - - 5,7 insulation thickness [mm] 57 Degree of protection IP 21
HE - Heat exchanger
On the rear side of the hot water tank there are special channels (H1, H2) for mounting the feelers for regulation of the system connection of the hot water tank to other heating sources. Access to the channels is under the covering joint of the protective covering, approximately in the middle of the tank height.
Insert the feeler into the channel and fix it with the enclosed rubber tap. Recommended position (h1, h2) of the feeler is marked on the drawing:
- If the feeler is mounted higher than recommended, the thermostat will react too fast, the operating time of the circular pump will be shorter and the difference between the temperature in the hot water tank and heating media after the thermostat switch off will be higher. This means that the quantity of water in the hot water tank and its temperature will be lower,
- If the feeler is mounted lower than recommended, the operating time of the circular pump will be longer and the difference between the temperature in the hot water tank and heating media after the thermostat switch off will be lower. This means that the quantity of water in the hot water tank and its temperature will be little higher.
Thermometer
Heater SH
Heater R
GB
Page 4
31
CONNECTION TO THE WATER SUPPLY
For safety reasons the supply pipe must be fitted with a return safety valve that prevents the pressure in the tank from exceeding nominal pressure by more than 0.1 MPa. The heating of water in the heater causes the pressure in the tank to increase to the level set by the safety valve. As the water cannot return to the water supply system, this can result in dripping from the outflow of the safety valve. The drip can be piped into the drain by installing a catching unit just below the safety valve. The drainpipe fitted under the safety valve outflow must be piped down in a straight vertical line and located in an environment free from the onset of freezing conditions. In case the existing plumbing does not enable you to pipe the dripping water from the return safety valve into the drain, you can avoid the dripping by installing expansion tank on the inlet water pipe of the boiler. The volume of the expansion vessel shall be at least 3% of the volume of the hot water tank.
Key:
1. Return safety valve
2. Test valve
3. Non-return valve
4. Pressure-reducing valve
5. Stop valve
6. Test unit
7. Funnel outlet to the drain
8. Drain valve
H - Cold water T - Hot water
The water heater may be connected to the household water supply system without a pressure-reducing valve provided the supply mains pressure is less than 0.5 MPa. In case of the mains pressure exceeding 0.5 MPa, a pressure-reducing valve must be installed to ensure that the pressure on the supply side of the heater does not rise above the nominal value.
GB
Page 5
32
9
7
T
3
12
2
1T
1
6
7
10
5
4
3
2T
9
8
5
TV
4T
12 8
15
7
14 11 13
CONNECTION TO ALTERNATIVE SOURCES OF HEATING
The heaters enable the water for sanitary use to be heated by alternative sources of energy (e.g. central heating, solar power, …) by installing one or two heat exchangers. Additionally, a heating pump may also be fitted to the side flange of the tank. Options for connecting the water heater to various sources of heating are shown in the drawings below.
Connection to solar panels Connection to the central heating hot-water system
1. Water heater
2. Central heating hot-water system
3. Solar panel
4. Differential thermostat with sensors (T1, T2, T3, T4)
5. Bypass pump
6. Expansion tank
7. Non-return valve
8. Safety valve
9. Air relief valve
10. Fill/drain valve
11. Reduction valve
12. Drain valve
13. Stop valve
14. Test unit
15. Funnel outlet to the drain
4
8 11 13
3
9
T
5
T
8
12
7
10
6
2
1
1
7 14
15
1
1T
4
9
7
T
3
12
2
5
128715141113
Connection to solar panels and central heating hot-water system
GB
Page 6
33
OPERATION AND MAINTENANCE
The water heater is ready for use once it has been connected to water and other sources of heating. The usual main sources of heating of water for sanitary use are central heating or solar power; in this case any regulation of water heating is performed in the heating system.
Electric heater type R may be additionally installed on the flange 180mm, or electric heater type SH to the connecting bushing G 6/4, which are used for additional heating of water:
- If you need higher temperature of water than assured by other heating sources,
- If due to seasonal or other conditions there are no main heating sources.
In case of exposure to sub-zero temperatures, the water should be thoroughly drained from the heater before the onset of freezing conditions. Once
that
is done, open the hot water tap on one of the mixer taps connected to the water heater. The water from the water heater drains by way of the drain valve on the inlet pipe. External parts of the water heater may be cleaned with a mild detergent solution. Do not use solvents and abrasive cleaners. Regular preventive maintenance inspections ensure faultless performance and long life of your heater. The first of these inspections should be carriedout by an authorised maintenance service provider about two years from the date of installation in order to inspect the wear of the corrosion protection anode and to remove any limestone as required. Build-up of limestone is a product of quality, quantity and temperature of water flowing through the water heater. While inspecting the heater, the maintenance service provider will also recommend the date of the next inspection. Wear of the corrosion protection anode is carried out visually. Replacement is required when the inspection reveals that the anode diameter has been substantially reduced or worn all the way to the steel core. Tank warranty is subject to regular inspections of the protective anode.
In the event of the water heater breaking down, you are kindly requested to contact the authorised maintenance service provider located closest to you. Please do not attempt to repair the unit yourself.
GB
Page 7
06/2008
766383
Gorenje Tiki, d.o.o. SI-1521 Ljubljana Magistrova 1 Slovenija Telefon: +386 1 5005 600 Fax: +386 1 5005 702
382 012 722