This equipment has been tested and found to comply with the limits for a CLASS A digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in
a commercial environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. Operation of this equipment
in a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at own expense.
EMS AND EMI COMPLIANCE STATEMENT
FOR EUROPEAN USERS
This equipment has been tested and passed with the requirements relating to
electromagnetic compatibility based on the standards EN 55022:2006/A1:2007 Class A,
EN61000-3-2:2006/A2:2009, EN 61000-3-3:2008 and EN55024:1998/A1:2001/A2:2003, IEC
61000-4-2:2008 series The equipment has also been tested and passed in accordance
with the European Standard EN55022 for the both Radiated and Conducted emissions
limits.
EZ PLUS SERIES
TO WHICH THIS DECLARATION RELATES
IS IN CONFORMITY WITH THE FOLLOWING STANDARDS
IEC 60950-1:2005(2nd Edition)+Am 1:2009, GB4943-2001 GB9254-2008(Class A)
GB17625.1-2003, EN 55022:2006/A1:2007 Class A, EN61000-3-2:2006/A2:2009, EN
61000-3-3:2008 and EN55024:1998/A1:2001/A2:2003, IEC 61000-4-2:2008 series, UL
60950-1, 1st Edition, 2007-10-31 CSA C22.2 No. 60950-1-03, 1st Edition, 2006-07, CFR 47,
Part 15
WARNING
This is a Class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures.
Label design software: QLabel-IV (for EZPL only)
Driver & DLL: Windows 2000, XP and Vista
1. Barcode printer
1-1. Box content
Please check that all of the following items are included with your printer:
Barcode printer
Power cord
USB cable
Label stock
Ribbon
Empty ribbon core
Quick reference guide
CD (with QLabel label software / user manual)
1-2. Specifications
EZ2000 Plus series
EZ-2000+/6000+ User’s Manua
1
Resident Fonts
Bitmap fonts: 6, 8, 10, 12, 14, 18, 24, 30, 16X26 and OCR A & B
Bitmap fonts 90°, 180°, 270° rotatable, single characters 90°, 180°, 270°
rotatable
Bitmap fonts 8 times expandable in horizontal and vertical directions
Scalable fonts 90°, 180°, 270° rotatable
Download Fonts
Bitmap fonts 90°, 180°, 270° rotatable, single characters 90°, 180°, 270°
rotatable
Asian fonts 90°, 180°, 270° rotatable and 8 times expandable in
horizontal and vertical directions
Scalable fonts 90°, 180°, 270° rotatable
Barcodes
1-D Bar codes:
Code 39, Code 93, Code 128 (subset A, B, C), UCC/EAN-128 K-Mart,
UCC/EAN-128, UPC A / E (add on 2 & 5), I 2 of 5, I 2 of 5 with Shipping
Bearer Bars, EAN 8 / 13 (add on 2 & 5), Codabar, Post NET, EAN 128, DUN
14, HIBC, MSI (1 Mod 10), Random Weight, Telepen, FIM, China Postal
Code, RPS 128 and GS1 DataBar
2-D Bar codes:
PDF417, Datamatrix code, MaxiCode, QR code and Micro QR code
Resident graphic file types are BMP and PCX, other graphic formats are
downloadable from the software
Interfaces
Serial port: RS-232 (DB-9)
USB port (default on)
CF Card socket
Ethernet 10/100Mbps print server (default off; disables USB when in use)
Control Panel
Backlit graphics LCD display: 128 x 64 dots or 4 lines x 16 characters
Three mono-color status-LEDs: Power on, Ribbon out, Media out
Control keys: FEED, PAUSE and CANCEL
Real Time Clock
Standard
Power
Auto Switching 100-240VAC, 50-60Hz
Environment
Operation temperature: 41°F to 104°F (5°C to 40°C)
Storage temperature: -4°F to 122°F (-20°C to 50°C)
Cutter Module
Internal Rewinder with Label Dispenser (peel)
Parallel port (Centronics 36-pin) and PS2 port
Applicator Interface (1 input, 3 outputs, power 500mA @ 5V)
802.11 b/g wireless print server (Default off; disables USB when in use.
Must remove Ethernet card to install)
External label roll holder for 10” (250 mm) O.D. label rolls
External label rewinder
*Specifications are subject to change without notice. All company and/or product names
are trademarks and/or registered trademarks of their respective owners.
** Minimum print height specification compliance can be dependent on non-standard
material variables such as label type, thickness, spacing, liner construction, etc.
Godex is pleased to test non-standard materials for minimum height printing
capability.
EZ-2000+/6000+ User’s Manua
2
Model
EZ6200 Plus
EZ6300 Plus
Print Method
Thermal Transfer / Direct Thermal
Resolution
203 dpi (8 dot/mm)
300 dpi (12 dot/mm)
Print Speed
6 IPS (150 mm/s)
4 IPS (102 mm/s)
Print Width
6.61” (168 mm)
Print Length
Min. 0.16” (4 mm)**
Max. 118” (3000 mm)
Min. 0.16” (4 mm)**
Max. 54” (1371 mm)
Memory
4MB Flash (2MB for user storage) ; 16MB SDRAM
Sensor Type
Adjustable reflective sensor and transmissive sensor, left aligned
Media
Types: Continuous form, gap labels, black mark sensing, and punched
hole; label length set by auto sensing or programming
Length: 1471’ (450 m)
Width: 2.36” Min - 6.85” (60 mm - 174 mm) Max
Ribbon roll diameter.: 2.99“ (76 mm)
Core diameter: 1” (25.4 mm)
Auto ink inside and ink outside
Printer Language
EZPL (Firmware upgradable)
Software
Label design software: QLabel-IV (for EZPL only)
Driver & DLL: Windows 2000, XP and Vista
Resident Fonts
Bitmap fonts: 6, 8, 10, 12, 14, 18, 24, 30, 16X26 and OCR A & B
Bitmap fonts 90°, 180°, 270° rotatable, single characters 90°, 180°, 270°
rotatable
Bitmap fonts 8 times expandable in horizontal and vertical directions
Scalable fonts 90°, 180°, 270° rotatable
Download Fonts
Bitmap fonts 90°, 180°, 270° rotatable, single characters 90°, 180°, 270°
rotatable
Asian fonts 90°, 180°, 270° rotatable and 8 times expandable in
horizontal and vertical directions
Scalable fonts 90°, 180°, 270° rotatable
EZ-2000+/6000+ User’s Manua
3
Barcodes
1-D Bar codes:
Code 39, Code 93, Code 128 (subset A, B, C), UCC/EAN-128 K-Mart,
UCC/EAN-128, UPC A / E (add on 2 & 5), I 2 of 5, I 2 of 5 with Shipping
Bearer Bars, EAN 8 / 13 (add on 2 & 5), Codabar, Post NET, EAN 128, DUN
14, HIBC, MSI (1 Mod 10), Random Weight, Telepen, FIM, China Postal
Code, RPS 128 and GS1 DataBar
2-D Bar codes:
PDF417, Datamatrix code, MaxiCode, QR code and Micro QR code
Resident graphic file types are BMP and PCX, other graphic formats are
downloadable from the software
Interfaces
Serial port: RS-232 (DB-9)
USB port (default on)
CF Card socket
Ethernet 10/100Mbps print server (default off; disables USB when in use)
Control Panel
Backlit graphics LCD display: 128 x 64 dots or 4 lines x 16 characters
Three mono-color status-LEDs: Power on, Ribbon out, Media out
Control keys: FEED, PAUSE and CANCEL
Real Time Clock
Standard
Power
Auto Switching 100-240VAC, 50-60Hz
Environment
Operation temperature: 41°F to 104°F (5°C to 40°C)
Storage temperature: -4°F to 122°F (-20°C to 50°C)
Cutter Module
Internal Rewinder with Label Dispenser (peel)
Parallel port (Centronics 36-pin) and PS2 port
Applicator Interface (1 input, 3 outputs, power 500mA @ 5V)
802.11 b/g wireless print server (Default off; disables USB when in use.
Must remove Ethernet card to install)
External label roll holder for 10” (250 mm) O.D. label rolls
External label rewinder
*Specifications are subject to change without notice. All company and/or product names
are
trademarks and/or registered trademarks of their respective owners.
** Minimum print height specification compliance can be dependent on non-standard
material
variables such as label type, thickness, spacing, liner construction, etc. Godex is pleased to
test
non-standard materials for minimum height printing capability.
4
EZ-2000+/6000+ User’s Manua
Handshaking
:
DSTB is sent to the printer, BUSY to the host computer
Interface
cable
:
Parallel cable compatible with IBM computers
Pinout
/Strobe
Data 0-7
/Acknowledge
Busy
/Paper empty
/Select
/Auto-Linefeed
N/C
Signal Gnd
Chassis Gnd
+5V, max 500mA
Signal Gnd
/Initialize
/Error
Signal Ground
N/C
/Select-in
Baud rate 9600, no parity, 8 data bits, 1 stop bit, XON/XOFF protocol
and RTS/CTS
DB9 socket
DB9 plug
---
1 1
+5V, max 500mA
RXD
2 2
TXD
TXD
3 3
RXD
DTR
4 4
N/C
GND
5 5
GND
DSR
6 6
RTS
RTS
7 7
CTS
CTS
8 8
RTS
RI
9 9
N/C
Computer
Printer
1-3. Interfaces Parallel port
Serial port
RS232 housing (9-pin to 9-pin)
【
Note】 The total current to the parallel and serial ports may not exceed 500 mA.
5
EZ-2000+/6000+ User’s Manua
Connector type
:
Type B
Pin No.
1 2 3
4
Function
VBUS
D-
D+
GND
Pin No.
1 2 3 4 5 6 Function
DATA
N/C
GND
VCC
CLOCK
N/C
Printer
Keyboard
DATA
1 1
DATA
N/C
2 2
N/C
GND
3 3
GND
VCC
4 4
VCC
CLOCK
5 5
CLOCK
N/C
6 6
N/C
UART1 wafer
Ethernet module
N.C
1 1
N.C
TXD
2 2
RXD
RXD
3 3
TXD
CTS
4 4
RTS
GND
5 5
GND
RTS
6 6
CTS
E_MD
7 7
E_MD
RTS
8 8
CTS
E_RST
9 9
E_RST
+5V
10 10
+5V
GND
11 11
GND
+5V
12 12
+5V
UART2 wafer
Add-on module
N.C
1 1
N.C
TXD
2 2
RXD
RXD
3 3
TXD
CTS
4 4
RTS
GND
5 5
GND
RTS
6 6
CTS
N.C
7 7
N.C
RTS
8 8
CTS
N.C
9 9
N.C
+5V
10 10
+5V
GND
11 11
GND
+5V
12 12
+5V
USB port
PS/2 port
PS/2 computer-to-printer interface
Internal interface
EZ-2000+/6000+ User’s Manua
6
Applicator wafer
Applicator module
+5V
1 1
+5V
+24V
2 2
+24V
Printing (out)
3 3
Printing
Print error (out)
4 4
Print error
Printed (out)
5 5
Printed
Print (in)
6 6
Print
GND
7 7
GND
N.C
8 8
GND
9 9
N.C
10 10
EZ-2000+/6000+ User’s Manua
7
4
3
1
2
1.
Operator panel with LCD display
2.
Lower cover plate
3.
Viewing window
4.
Printer cover
1
2
11
6
8
10
12
3
4
5
9
7
1.
Feed slot for continuous labels
2.
CF card slot
3.
Parallel port (optional)
4.
WLAN antenna interface (optional)
5. N
Ethernet port
6.
Serial port (DB-9)
7.
PS/2 port (optional)
8.
Applicator interface (optional)
9.
USB port
10.
On/Off switch
11.
Power jack
12.
Feed slot for continuous labels
1-4. Getting to know your printer
External view
EZ-2000+/6000+ User’s Manua
8
1
2
3
4
5
6
7
12
11
10
9
8
1.
Ribbon rewind hub
2.
Ribbon supply hub
3.
Print mechanism
4.
Platen roller
5.
Tear-off plate
6.
Release lever for print head
7.
Adjustment wheel for sensor
8.
Paper guide
9.
Label tension guide
10.
Label supply hub
11.
Label roll guide
12.
Release catch
1
1.
Movable sensor
Internal view
EZ-2000+/6000+ User’s Manua
9
Thermal transfer
printing (TTP)
Requires a ribbon for transferring a printed image to a medium.
Direct thermal
printing (DTP)
Does not require a ribbon, only thermal paper.
1. Place the printer on a
flat surface and open
the printer cover.
2. Pull out the print
head release lever as
shown in the
illustration (1) and
turn it anticlockwise
to a top right position
(2).
2
1
3. Pull the release catch
for the label roll guide
to the right as shown
by the blue arrow 1.
4. Now slide the label
roll guide forward
and fold it up as
shown by the blue
arrow 2.
2
1
2. Printer setup
This printer supports the following printing methods:
Please check which printing method you are using and alter the settings accordingly in
the printer driver, printer menu, and/or software.
2-1. Loading the label roll
10
EZ-2000+/6000+ User’s Manua
5. Place the label roll on
the label supply hub,
pushing it right up to
the printer housing.
(Do not apply too
much pressure to
avoid damaging the
label stock.)
6. Fold the label roll
guide back down
and push it against
the label roll.
【
Note】
When moving the label roll
guide, hold it only by the
end that is attached to
the bracket, not by its top.
7. Load the label roll
into the printer as
shown in the
illustration. Pass it
through the printer as
indicated by the blue
arrows.
8. Pass the label stock
through the sensor
and up to the tear-off
plate.
【
Note】
Remember to set the
movable sensor to gap,
black mark, or tag hole by
changing the position of
the sensor with the
adjustment wheel.
1
2
3
EZ-2000+/6000+ User’s Manua
11
9. The labels pass
between the wall of
the printer housing
and the adjustable
paper guide.
【
Note】
Pass the labels through the
printer as shown in the
illustration.
10. Return the print head
release lever to its
original position.
11. Then close the printer
cover.
EZ-2000+/6000+ User’s Manua
12
1. Place the printer
on a flat surface
and open the
printer cover.
2. Pull out the print
head release
lever as shown in
the illustration (1)
and turn it
anticlockwise to a
top right position
(2).
2
1
3. Place a new
ribbon on the
ribbon supply
hub. Then place
an empty ribbon
core on the
ribbon rewind
hub.
4. The two
illustrations on the
right show you
how to install the
ribbon
depending on
the ribbon type
(ink side in or out).
Ink side out
Ink side in
5. Pass the ribbon
under the print
head and back
up on the other
side. Attach it to
the empty ribbon
core.
【
Note】
Do not pass the
ribbon under the
sensor.
2-2. Loading the ribbon
EZ-2000+/6000+ User’s Manua
13
2-3. Connecting the printer to the host computer
1. Please make sure that the printer is switched off.
2. Connect the power cord to the AC adapter and connect the adapter to the
printer.
3. Connect the USB cable to the printer and host computer.
4. Switch on the printer. The operator panel should now light up.
EZ-2000+/6000+ User’s Manua
14
1. Insert the product CD in the
CD/DVD drive of the host
computer and open the
"Windows Drivers" folder on
the CD.
2. Select the icon for the
driver file and click it to
start the installation.
3. Follow the instructions on
the screen. The Driver
Wizard guides you through
the installation procedure.
4. Select "Install printer
drivers".
5. Specify your printer model.
2-4. Installing the driver
EZ-2000+/6000+ User’s Manua
15
6. Specify the port used to
connect the printer to the
host computer.
7. Enter a printer name and
assign the appropriate
rights.
8. Once the installation is
complete, a summary of
the printer settings is
displayed.
9. Check whether the printer
settings are correct and
click "Finish" to start
copying the driver files.
10. Wait until copying is
complete, then finish the
installation.
11. Once the driver installation
is complete, the new
printer should be visible in
the "Printers and Faxes"
folder.
EZ-2000+/6000+ User’s Manua
16
Function buttons
FEED
PAUSE
CANCEL
LED indicators
POWER
The POWER (Ready) LED
lights up when the printer
has started up and is
ready to print.
RIBBON
Ribbon status indicator
MEDIA
Media status indicator
3. Operator panel
3-1. Operator panel – introduction
3-2. Function buttons – introduction
FEED button
When you press the FEED button, the printer moves the label to the defined stop
position. If you are using continuous labels, pressing the FEED button will move label
stock until you release the button again. If you are using individual labels, pressing
the FEED button will move only one label. If the label does not stop at the correct
position, you need to run the auto-detection function on the label stock (see
Section 3-6).
PAUSE button
Pressing the PAUSE button while the printer is in standby mode will set the printer to
pause mode. The message "Pause" is shown on the LCD display. In this mode, the
printer can receive commands, but it can only process them when it is reset to
standby mode. Pressing the PAUSE button again will reset the printer to standby
mode.
Pressing the PAUSE button during printing will interrupt printing. When the PAUSE
button is pressed again, the printer resumes printing. Example: While a 10-label print
job is running, you press the PAUSE button to pause the printer. Two of the labels
have been printed. To resume printing and print the remaining eight labels, you
press the PAUSE button again.
CANCEL button
Pressing the CANCEL button during printing cancels a print job. The message "Print
job cancelled" is shown on the LCD display. The current print job is cancelled.
Example: While a 10-label print job is running, you press the CANCEL button. Two of
the labels have been printed. The print job is cancelled and the remaining eight
labels are not printed.
EZ-2000+/6000+ User’s Manua
17
Loading...
+ 46 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.