General ARH45L, ARH45LUAN, AOH45LJBYL Technical Manual

R410A
4 . DUCT TYPE :  AR 45LUAN
D2D_AR003E/03
2006.05.30
MODEL : AR 45LUAN / AO 45LJBYL
FEATURES
Installation styles
Embedded in Ceiling
Hanging from Ceiling
DUCT TYPE
AR45
Low static pressure mode function
1.Low static pressure mode 1 air volume at 85Pa (fan speed:high)
2.Normal Mode Air volume at 100Pa (fan speed:high)
When installed, normal middle static pressure mode, and low static pressure mode can be selected by switching over using DIP switch on the board in the control box. Therefore, these models can be op­erated under the wide range of conditions.
(230V)
/h)
3
Air volume (m
0 85 100
Static pressure (Pa)
1 2
DUCT TYPE
AR45
Slim & compact design
In the case of bottom suction type, as seen from lower rear part.
Control Box that has been convex shape is now united with main unit (DIP Switch is located on the internal substrate.)
One-touch operating and easy-to-install long-life filter (optional)
In addition to the slim height of 270 mm which is our sales point, further com­pactification is attained by reducing 65 mm from the width with the flanking control box embedded inside the chassis.
- (04 - 01) -
EASY MAINTENANCE
In the case of rear suction type, as seen from lower rear part.
Conventional model
1
3
4
New model
4
1
1.Control box
2.Fan casing
3.Fan
4.Motor
2
2
3
Bottom panel: 2 units
Large bottom panel: 1 unit
Structural improvement is attained by making the bottom panel two pieces, front and rear, and the internal fan casing is also made dismountable in two pieces namely, upper and lower ones.
DUCT TYPE
AR45
The motor and fan maintenance and dismounting can be made easily by removing the rear panel and lower part of the casing with the main chassis installed.
DUCT TYPE
AR45
- (04 - 02) -
4-2. REMOTE CONTROLLER
4-2-1. WIRED REMOTE CONTROLLER
FEATURES
Various timer setup (ON / OFF / WEEKLY) are possible. Equipped with weekly timer as standard function.
(2 times Start / Stop per day for a week)
SUMOTUWETH FR SA
7
3126 9
15 18 21
When setting up a timer, operation mode and a temperature setup can be changed.
When a failure occurs,the error code is displayed. (Maximum of 16) Error indication.(A maximum of 16 error histories are memorizable.) Up to 16 indoor units can be simultaneously controlled.
Anti freeze and energy saving operation are possible. Easy installation with a slim shape with no boldge in the back.
The room temperature can be controlled by being detected the temperature accurately with built-in thermo sensor.
High performance and compact size
Three functions are combined in
DUCT TYPE
AR45
Wired
remote
controller
Weekly
timer
Setback
timer
DUCT TYPE
AR45
Built-in timers
Setback timerWeekly timer
Possible to set ON/OFF time to operate twice each day of the week.
SUMOTUWETH FR SA
7
3126 9
15 18 21
Setup screen example (Set to Wednesday: 8:00 to 20:00.)
0 3 6 9 12 15 18 21 Time
Easy-to-understand time bar display
24°C
SUMOTUWETH FR SA
7
3126 9
15 1821
Screen after setup
At "Weekly timer" + "Set back timer" setup
24°C 28°C 24°C
0 3 6 9 12 15 18 21 Time
Timer area
Operation area
Possible to set temperature for two time spans and for each day of the week.
SUMOTUWETH FR SA
3126 9
15 18 21
Setup screen example (Set from Sunday to Saturday: 12:00 to 15:00, 28 °C.)
28°C
0 3 6 9 12 15 18 21 Time
24°C
28°C
Simple installationEasy-to-understand operation
Components are compatible with standard switch boxes. Flat back construction allows equipment to be installed wherever it is needed.
[
Variable timer control
]
The operation/display sections are zoned accord­ing to time and operation, enabling variable pro­gramming to match application.
- (04 - 03) -
European switch box
JIS box
FUNCTIONS
1
START/STOP button
Pressed to start and stop operation.
Display
2 7 8
9
10
SUMOTUWETH FR
369
CLOCK ADJUST
SET BACK
DELETE SET
12 15 18 21
DAY
DAY OFF
SA
13
1 3
ENERGY
SAVE
THERMO SENSOR
4
6
2
Set temperature button
Selects the setting temperature.
3
Master control button
Selects the operating mode(AUTO, HEAT, FAN, COOL, DRY).
4
Fan control button
Selects the fan speed (AUTO, LOW, MED, HIGH).
5
Energy save button
Turns the energy efficient mode on and off.
11
12
5
6
Thermo sensor
7
Timer mode (CLOCK ADJUST) button
Selects the timer mode (OFF TIMER, ON TIMER, WEEKLY TIMER) Set the current time.
8
Day (DAY OFF) button
Display panel
DUCT TYPE
AR45
14
15
1617 18
Temporarily cancels of one day timer.
9
Set back button
pressed select the set back timer.
10
Set time button
DUCT TYPE
AR45
Pessed to select the set back timer.
SUMOTUWETH FR
SA
11
Delete button
The schedule of a weekly timer is deleted.
369
12 15 18 21
1920
12
Set button
Sets the date, hour, minute and on-off time.
13
Operation lamp
Lights during operation and when the timer is on.
DIMENSION
[ Unit : mm ]
17
120
SUMOTUWETH FR
369
12 15 18 21
DAY
CLOCK ADJUST
DAY OFF
SET BACK
DELETE SET
Front View
120
SA
ENERGY
SAVE
THERMO SENSOR
SPECIFICATION
SIZE (H x W x D mm) 120 x 120 x 17
WEIGHT ( g ) 160
CABLE LENGTH ( m )
POWER ( V )
10
12
14
Timer and clock display
15
Operation mode display
16
Fan speed display
17
Central control display
18
Temperature display
19
Stand by display Indicates during the oil recovery and defrosting operation.
20
Energy save display
- (04 - 04) -
4-3. SPECIFICATIONS
AR 45LUAN
AO 45LJBYL
230V 50Hz
198-264V
Rows x Stages mm 4 x 14
Fin Pitch 1.4
Rows x Stages mm 2 x 60
Fin Pitch 1.3
FAN MOTOR THERMAL PROTECTOR
PCB FUSE
FAN MOTOR THERMAL PROTECTOR
PCB FUSE
9.52(3/8 inc.)
15.88(5/8 inc.)
Steel
Outer diameter 38.0
Inner diameter 36.0
AVAILABLE VOLTAGE RANGE
PIPE
MAX HEIGHT
CONNECTION METHOD
SIZE
mm
kg(lbs)
DIMENSIONS H × W × D NET
GROSS TYPE
OUTDOOR
CASING COLOR STARTING METHOD
Surface treatment
NET / GROSS
WEIGHT
mm
MAX LENGTH
REMOTE CONTROLLER
DRAIN PIPE MATERIAL
REFRIGERANT
SIZE
TYPE
OPERATION(OUTDOOR)
°C
REFRIGERANT OIL
kW
SAFETY DEVICES
OUTDOOR
AIR CIRCULATION INPUT POWER
TYPE
COMPRESSOR
HEAT EXCHANGER TYPE
MOISTURE REMOVAL
CURRENT
kW/kW
RECOMMENDED STATIC PRESSURE
FAN TYPE x Q'ty
A
STARTING CURRENT
INDOOR
m3/h
TYPE
MODEL NAME
OUTDOOR
POWER SOURCE
INDOOR
COOLING
HEATING
CAPACITY
RATED/MAX
RATED/MAX
FAN MOTOR OUTPUT
W
OUTDOOR
NOISE LEVEL (SOUND PRESSURE)
COOL/HEAT
Surface treatment
Coil
INDOOR
Coil
dB(A)
INDOOR
COOLING RATED/MAX 4.45/5.15
HEATING RATED/MAX 3.95/5.15
COOLING RATED/MAX 19.5/22.6
HEATING RATED/MAX 17.3/22.5
EER COOLING 2.81
COP HEATING 3.54
High 2290
Med 2150
Low 2000
INDOOR Sirocco x 2
OUTDOOR Propeller x 2
INDOOR 275
DUCT TYPE
AR45
OUTPUT W 2500
OUTDOOR 103 × 2
High 44.0/44.0
Med 42.0/42.0
Low 40.0/40.0
DUCTED MODELS
REVERSE CYCLE TYPE
kW 12.5/14.0
BTU/h 42700/47800
kW 14.0/17.0
BTU/h 47800/61500
A 15
l/h (pints/h) 4.0(8.5)
6600
Pa 30 to 150
52.0/53.0
DC SCROLL(INVERTER)
Inverter Method
Plate fin coil
Hydrophilic coating
DUCT TYPE
AR45
Coil Dimensions mm 294 x 1000 x 53.2
Plate fin coil
Corrosion resistant coating
Coil Dimensions mm 1260 x 900 x 36.38
INDOOR
OUTDOOR
INDOOR Galvanized steel sheet
OUTDOOR Beige(10YR7.5/1.0NN)
INDOOR 270 x 1135 x 700
OUTDOOR 1290 x 900 x 330
INDOOR 300 x 1300 x 790
OUTDOOR 1430 x 1050 x 445
INDOOR 45/52(99/115)
OUTDOOR 105/112(231/247)
FLARE
LIQUID
GAS
m 70(chargeless:20m)
m 30
R410A
CHARGE kg 3.4
Synthetic (POE oil)
COOLING -15 to 43
HEATING -15 to 24
WIRED(AR-3TA1)
Note: Specifications are based on the following conditions. Cooling: Indoor temperature of 27 °CDB / 19 °CWB,and outdoor temperature of 35 °CDB/24 °CWB. Heating: Indoor temperature of 20 °CDB / 15 °CWB,and outdoor temperature of 7 °CDB/6 °CWB. Standard static pressure : 30Pa Pipe length : 7.5 m, Height difference : 0 m.(Outdoor unit - Indoor unit)
mm
- (04 - 05) -
4-4. DIMENSIONS
4-4-1. OUTDOOR UNIT
MODEL : AO 45L
(Unit : mm)
Top view
900
1290
DUCT TYPE
AR45
21
77 31
12330
DUCT TYPE
AR45
Front view
370
Drain cap mounting places
Drain cap mounting place
Bottom view
MOUNTING POSITION
When there are obstacles at the back or front side.
When there are obstacles at the back and front sides.
9
Air flow
Side view
4-Ø12mm hole
When there are obstacles at the back, side(s), and top.
400
151
170
196
99
When there are obstacles at the back side with the installation of more than one unit.
100 mm
or more
600 mm
or more
100 mm or more
100 to 300 mm *
* If the space is larger than that is stated, the condition
will be the same as that there are no obstacles.
25
0
(
Se
m
m
r
v
or
i
c
e
mor
s
pac
e
e
)
- (04 - 06) -
600 to 1000 mm
300 mm or more
250 mm or more
250 mm or more
300 mm or more
4-4-2. INDOOR UNIT
MODEL :
AR 45L
(Unit : mm)
Front view
DUCT TYPE
DUCT TYPE
AR45
AR45
Side view (L)
Top view
Side view (R)
Rear view
Refrigerant piping flare connection (Gas) Refrigerant piping flare connection (Liquid) Drain piping connection (Drain pipe : I.D. 36 O.D. 38) Drain piping connection with cap. Knock out hole for fresh air.
- (04 - 07) -
MOUNTING POSITION
300mm
or more
150mm or more
MAINTENANCE HOLE
It shall be possible to install and remove the control box.
DUCT TYPE
AR45
When using a square duct
It shall be possible to install and remove the control box, fan units and filter.
(Unit : mm)
DUCT TYPE
AR45
- (04 - 08) -
4-5. REFRIGERANT CIRCUIT
MODELS : AR 45L / AO 45L
DUCT TYPE
DUCT TYPE
AR45
AR45
- (04 - 09) -
4-6. WIRING DIAGRAMS
4-6-1. OUTDOOR UNIT
MODEL : AO 45L
DUCT TYPE
DUCT TYPE
AR45
AR45
- (04 - 10) -