1.Low static pressure mode 1 air volume at 85Pa (fan speed:high)
2.Normal Mode Air volume at 100Pa (fan speed:high)
When installed, normal middle static pressure mode, and low static
pressure mode can be selected by switching over using DIP switch
on the board in the control box. Therefore, these models can be operated under the wide range of conditions.
(230V)
/h)
3
Air volume (m
085 100
Static pressure (Pa)
12
DUCT TYPE
AR45
Slim & compact design
In the case of bottom suction type, as seen from lower rear part.
Control Box that has been convex shape
is now united with main unit (DIP Switch is
located on the internal substrate.)
One-touch operating and easy-to-install
long-life filter (optional)
In addition to the slim height of 270 mm which is our sales point, further compactification is attained by reducing 65 mm from the width with the flanking
control box embedded inside the chassis.
- (04 - 01) -
EASY MAINTENANCE
In the case of rear suction type, as seen from lower rear part.
Conventional model
1
3
4
New model
4
1
1.Control box
2.Fan casing
3.Fan
4.Motor
2
2
3
Bottom panel: 2 units
Large bottom panel: 1 unit
Structural improvement is attained by making the bottom panel two pieces, front and
rear, and the internal fan casing is also made dismountable in two pieces namely,
upper and lower ones.
DUCT TYPE
AR45
The motor and fan maintenance and dismounting can be made easily by removing
the rear panel and lower part of the casing with the main chassis installed.
DUCT TYPE
AR45
- (04 - 02) -
4-2. REMOTE CONTROLLER
4-2-1. WIRED REMOTE CONTROLLER
FEATURES
Various timer setup (ON / OFF / WEEKLY) are possible.
Equipped with weekly timer as standard function.
(2 times Start / Stop per day for a week)
SUMOTUWETH FR SA
7
3126 9
15 18 21
When setting up a timer, operation mode and a temperature
setup can be changed.
When a failure occurs,the error code is displayed. (Maximum of 16)
Error indication.(A maximum of 16 error histories are memorizable.)
Up to 16 indoor units can be simultaneously controlled.
Anti freeze and energy saving operation are possible.
Easy installation with a slim shape with no boldge in the back.
The room temperature can be controlled by being detected the temperature
accurately with built-in thermo sensor.
High performance and compact size
Three functions are combined in
DUCT TYPE
AR45
Wired
remote
controller
Weekly
timer
Setback
timer
DUCT TYPE
AR45
Built-in timers
Setback timerWeekly timer
Possible to set ON/OFF time to operate twice each day
of the week.
SUMOTUWETH FR SA
7
3126 9
15 18 21
Setup screen example
(Set to Wednesday: 8:00 to 20:00.)
0 3 6 9 12 15 18 21 Time
Easy-to-understand time bar display
24°C
SUMOTUWETH FR SA
7
3126 9
15 1821
Screen
after setup
At "Weekly timer" + "Set back timer" setup
24°C 28°C 24°C
0 3 6 9 12 15 18 21 Time
Timer
area
Operation
area
Possible to set temperature for two time spans and
for each day of the week.
SUMOTUWETH FR SA
3126 9
15 18 21
Setup screen example
(Set from Sunday to Saturday: 12:00 to 15:00, 28 °C.)
28°C
0 3 6 9 12 15 18 21 Time
24°C
28°C
Simple installationEasy-to-understand operation
Components are compatible with standard
switch boxes. Flat back construction allows
equipment to be installed wherever it is
needed.
[
Variable timer control
]
The operation/display sections are zoned according to time and operation, enabling variable programming to match application.
- (04 - 03) -
European
switch box
JIS box
FUNCTIONS
1
START/STOP button
Pressed to start and stop operation.
Display
2
7
8
9
10
SUMOTUWETH FR
369
CLOCK ADJUST
SET BACK
DELETESET
12 15 18 21
DAY
DAY OFF
SA
13
1
3
ENERGY
SAVE
THERMO
SENSOR
4
6
2
Set temperature button
Selects the setting temperature.
3
Master control button
Selects the operating mode(AUTO, HEAT, FAN, COOL, DRY).
4
Fan control button
Selects the fan speed (AUTO, LOW, MED, HIGH).
5
Energy save button
Turns the energy efficient mode on and off.
11
12
5
6
Thermo sensor
7
Timer mode (CLOCK ADJUST) button
Selects the timer mode (OFF TIMER, ON TIMER, WEEKLY TIMER)
Set the current time.
8
Day (DAY OFF) button
Display panel
DUCT TYPE
AR45
14
15
1617 18
Temporarily cancels of one day timer.
9
Set back button
pressed select the set back timer.
10
Set time button
DUCT TYPE
AR45
Pessed to select the set back timer.
SUMOTUWETH FR
SA
11
Delete button
The schedule of a weekly timer is deleted.
369
12 15 18 21
1920
12
Set button
Sets the date, hour, minute and on-off time.
13
Operation lamp
Lights during operation and when the timer is on.
DIMENSION
[ Unit : mm ]
17
120
SUMOTUWETH FR
369
12 15 18 21
DAY
CLOCK ADJUST
DAY OFF
SET BACK
DELETESET
Front View
120
SA
ENERGY
SAVE
THERMO
SENSOR
SPECIFICATION
SIZE (H x W x D mm)120 x 120 x 17
WEIGHT( g )160
CABLE LENGTH( m )
POWER( V )
10
12
14
Timer and clock display
15
Operation mode display
16
Fan speed display
17
Central control display
18
Temperature display
19
Stand by display
Indicates during the oil recovery and defrosting operation.
20
Energy save display
- (04 - 04) -
4-3. SPECIFICATIONS
AR 45LUAN
AO 45LJBYL
230V 50Hz
198-264V
Rows x Stagesmm4 x 14
Fin Pitch1.4
Rows x Stagesmm2 x 60
Fin Pitch1.3
FAN MOTOR THERMAL PROTECTOR
PCB FUSE
FAN MOTOR THERMAL PROTECTOR
PCB FUSE
9.52(3/8 inc.)
15.88(5/8 inc.)
Steel
Outer diameter 38.0
Inner diameter 36.0
AVAILABLE VOLTAGE RANGE
PIPE
MAX HEIGHT
CONNECTION METHOD
SIZE
mm
kg(lbs)
DIMENSIONS
H × W × D
NET
GROSS
TYPE
OUTDOOR
CASING COLOR
STARTING METHOD
Surface treatment
NET /
GROSS
WEIGHT
mm
MAX LENGTH
REMOTE CONTROLLER
DRAIN PIPE
MATERIAL
REFRIGERANT
SIZE
TYPE
OPERATION(OUTDOOR)
°C
REFRIGERANT OIL
kW
SAFETY DEVICES
OUTDOOR
AIR
CIRCULATION
INPUT POWER
TYPE
COMPRESSOR
HEAT
EXCHANGER
TYPE
MOISTURE REMOVAL
CURRENT
kW/kW
RECOMMENDED STATIC PRESSURE
FAN TYPE x Q'ty
A
STARTING CURRENT
INDOOR
m3/h
TYPE
MODEL NAME
OUTDOOR
POWER SOURCE
INDOOR
COOLING
HEATING
CAPACITY
RATED/MAX
RATED/MAX
FAN MOTOR OUTPUT
W
OUTDOOR
NOISE LEVEL
(SOUND
PRESSURE)
COOL/HEAT
Surface treatment
Coil
INDOOR
Coil
dB(A)
INDOOR
COOLINGRATED/MAX4.45/5.15
HEATINGRATED/MAX3.95/5.15
COOLINGRATED/MAX19.5/22.6
HEATINGRATED/MAX17.3/22.5
EER COOLING2.81
COP HEATING3.54
High2290
Med2150
Low2000
INDOORSirocco x 2
OUTDOORPropeller x 2
INDOOR275
DUCT TYPE
AR45
OUTPUTW2500
OUTDOOR103 × 2
High44.0/44.0
Med42.0/42.0
Low40.0/40.0
DUCTED MODELS
REVERSE CYCLE TYPE
kW12.5/14.0
BTU/h42700/47800
kW14.0/17.0
BTU/h47800/61500
A15
l/h (pints/h)4.0(8.5)
6600
Pa30 to 150
52.0/53.0
DC SCROLL(INVERTER)
Inverter Method
Plate fin coil
Hydrophilic coating
DUCT TYPE
AR45
Coil Dimensionsmm294 x 1000 x 53.2
Plate fin coil
Corrosion resistant coating
Coil Dimensionsmm1260 x 900 x 36.38
INDOOR
OUTDOOR
INDOORGalvanized steel sheet
OUTDOORBeige(10YR7.5/1.0NN)
INDOOR270 x 1135 x 700
OUTDOOR1290 x 900 x 330
INDOOR300 x 1300 x 790
OUTDOOR1430 x 1050 x 445
INDOOR45/52(99/115)
OUTDOOR105/112(231/247)
FLARE
LIQUID
GAS
m70(chargeless:20m)
m30
R410A
CHARGEkg3.4
Synthetic (POE oil)
COOLING-15 to 43
HEATING-15 to 24
WIRED(AR-3TA1)
Note:Specifications are based on the following conditions.
Cooling:Indoor temperature of 27 °CDB / 19 °CWB,and outdoor temperature of 35 °CDB/24 °CWB.
Heating:Indoor temperature of 20 °CDB / 15 °CWB,and outdoor temperature of 7 °CDB/6 °CWB.
Standard static pressure : 30Pa
Pipe length : 7.5 m, Height difference : 0 m.(Outdoor unit - Indoor unit)
mm
- (04 - 05) -
4-4. DIMENSIONS
4-4-1. OUTDOOR UNIT
MODEL : AO 45L
(Unit : mm)
Top view
900
1290
DUCT TYPE
AR45
21
7731
12330
DUCT TYPE
AR45
Front view
370
Drain cap
mounting places
Drain cap
mounting place
Bottom view
MOUNTING POSITION
When there are
obstacles at the
back or front side.
When there are obstacles
at the back and front sides.
9
Air flow
Side view
4-Ø12mm hole
When there are obstacles at
the back, side(s), and top.
400
151
170
196
99
When there are obstacles
at the back side with the
installation of more than
one unit.
100 mm
or more
600 mm
or more
100 mm
or more
100 to 300 mm *
* If the space is larger than that is stated, the condition
will be the same as that there are no obstacles.
25
0
(
Se
m
m
r
v
or
i
c
e
mor
s
pac
e
e
)
- (04 - 06) -
600 to 1000 mm
300 mm
or more
250 mm
or more
250 mm
or more
300 mm
or more
4-4-2. INDOOR UNIT
MODEL :
AR45L
(Unit : mm)
Front view
DUCT TYPE
DUCT TYPE
AR45
AR45
Side view (L)
Top view
Side view (R)
Rear view
Refrigerant piping flare connection (Gas)
Refrigerant piping flare connection (Liquid)
Drain piping connection (Drain pipe : I.D. 36 O.D. 38)
Drain piping connection with cap.
Knock out hole for fresh air.
- (04 - 07) -
MOUNTING POSITION
300mm
or more
150mm
or more
MAINTENANCE HOLE
It shall be possible to install and remove
the control box.
DUCT TYPE
AR45
When using a square duct
It shall be possible to install and remove
the control box, fan units and filter.
(Unit : mm)
DUCT TYPE
AR45
- (04 - 08) -
4-5. REFRIGERANT CIRCUIT
MODELS : AR 45L / AO 45L
DUCT TYPE
DUCT TYPE
AR45
AR45
- (04 - 09) -
4-6. WIRING DIAGRAMS
4-6-1. OUTDOOR UNIT
MODEL : AO45L
DUCT TYPE
DUCT TYPE
AR45
AR45
- (04 - 10) -