©2012 General Electric Company. All rights reserved.
Features
Compliant to RoHS II EU “Directive 2011/65/EU (-Z versions)
Compliant to REACH Directive (EC) No 1907/2006
Ultra-wide Input Voltage Range, 18V
dc
to 75Vdc
No minimum load
High efficiency – 87.5% at full load (V
IN
=24 or 48Vdc)
Constant switching frequency
Low output ripple and noise
Small Size and low profile, follows industry standard 1x1
footprint
27.9mm x 24.4mm x 8.5mm (MAX)
(1.10 x 0.96 x 0.335 in)
Surface mount (SMT) or Through hole (TH)
Reflow process compliant, both SMT and TH versions
Positive Remote On/Off logic
Output overcurrent/voltage protection (hiccup)
Over-temperature protection
Output Voltage adjust: 90% to 110% of V
o,nom
Wide operating temperature range (-40°C to 85°C)
CAN/CSA† C22.2 No. 60950-1-07, 2nd Edition + A1:2011
(MOD), ANSI/UL# 60950-1-2011, December 19, 2011; DIN EN
60950-1 (VDE‡ 0805-1):2011-01 DIN EN 60950-1/A12 (VDE
0805-1/A12):2011-08 EN 60950-1:2006 + A11:2009 +
A1:2010 + A12:2011 IEC 60950-1:2005 (2nd Edition);
am1:2009
CE mark meets 2006/95/EC directive§
Meets the voltage and current requirements for ETSI 300-
132-2 and complies with and licensed for Basic insulation
rating per EN60950-1
2250 Vdc Isolation tested in compliance with IEEE 802.3¤
PoE standards
ISO** 9001 and ISO 14001 certified manufacturing facilities
Applications
Wireless Networks
Hybrid power architectures
Optical and Access Network Equipment
Enterprise Networks including Power over Ethernet (PoE)
Industrial markets
Options
Negative Remote On/Off logic
Surface Mount/Tape and Reel (-SR Suffix)
Description
The SHHD001A3B Hammerhead series power modules are isolated dc-dc converters that operate over an ultra-wide input voltage
range of 18 Vdc -75Vdc and provide a single precisely regulated output voltage at 12Vdc. This series is a low cost, smaller size
alternative to the existing LW/LAW/LC/SC/SW with enhanced performance parameters. The output is fully isolated from the input,
allowing versatile polarity configurations and grounding connections. The modules exhibit high efficiency of 87.5% typical at full
load. Built-in filtering for both input and output minimizes the need for external filtering. The module is fully self-protected with
output over-current and over-voltage, over-temperature and input under voltage shutdown control. Optional features include
negative or positive on/off logic and SMT connections.
* Trademark of General Electric Company
# UL is a registered trademark of Underwriters Laboratories, Inc.
†
CSA is a registered trademark of Canadian Standards Association.
‡
VDE is a trademark of Verband Deutscher Elektrotechniker e.V.
§ This product is intended for integration into end-user equipment . All of the required procedures of end-use equipment should be followed.
¤ IEEE and 802 are registered trademarks of the Institute of Electrical and Electronics Engineers, Incorporated.
** ISO is a registered trademark of the International Organization of Standards.
SHHD001A3B Hammerhead* Series; DC-DC Converter Power Modules
18-75Vdc Input; 12Vdc, 1.3A, 15W Output

SHHD001A3B Hammerhead Series; DC-DC Converter Power Modules
18-75Vdc Input; 12Vdc, 1.3A, 15W Output
©2012 General Electric Company. All rights reserved.
Input Voltage (Continuous)
Operating Ambient Temperature
(see Thermal Considerations section)
I/O Isolation Voltage (100% factory Hi-Pot tested)
VIN = 24Vdc, (IO = 0, module enabled)
VIN = 48Vdc, (IO = 0, module enabled)
(VIN = 24 to 48Vdc, module disabled)
Maximum Input Current (VIN=18Vdc, IO=I
O, max
)
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 12μH source impedance; VIN=0V to 75Vdc, IO= I
Omax
;
see Test configuration section)
Input Ripple Rejection (120Hz)
EMC, EN55022 See EMC Considerations section
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings
only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations
sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability.
* For higher altitude applications, contact your GE Sales Representative for alternative conditions of use.
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to being part of
complex power architecture. To preserve maximum flexibility, internal fusing is not included; however, to achieve maximum safety
and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating of 3A
(see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc input
current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data sheet for further information.

SHHD001A3B Hammerhead Series; DC-DC Converter Power Modules
18-75Vdc Input; 12Vdc, 1.3A, 15W Output
©2012 General Electric Company. All rights reserved.
(VIN=24 to 48Vdc, IO=I
O, max
, TA=25°C)
(Over all operating input voltage, resistive load, and temperature
conditions until end of life)
Selected by external resistor
Line (VIN=V
IN, min
to V
IN, max
)
Load (IO=I
O, min
to I
O, max
)
Temperature (T
ref=TA, min
to T
A, max
)
Output Ripple and Noise on nominal output
Measured with 10uF Tantalum||1uF ceramic
(VIN=24 to 48Vdc, IO=80%I
RMS (5Hz to 20MHz bandwidth)
Peak-to-Peak (5Hz to 20MHz bandwidth)
Output Current Limit Inception (Hiccup Mode)
Output Short-Circuit Current
Efficiency
VIN=24-48Vdc, TA=25°C, IO=I
O, max
Switching Frequency (Fixed)
VIN=24 to 48Vdc and IO= I
O, max
(IO/t=0.1A/s, VIN=24 to 48Vdc, TA=25°C)
Load Change from IO= 50% to 75% or 25% to 50% of I
Settling Time (Vo<10% peak deviation)
Calculated Reliability based upon Telcordia SR-332 Issue 2: Method I Case 3
(VIN=48Vdc, IO=80%xI
O, max
, TA=40°C, airflow = 200 LFM, 90% confidence)
Electrical Specifications (continued)
Isolation Specifications
General Specifications

SHHD001A3B Hammerhead Series; DC-DC Converter Power Modules
18-75Vdc Input; 12Vdc, 1.3A, 15W Output
©2012 General Electric Company. All rights reserved.
Remote On/Off Signal Interface
(VIN=V
IN, min
to V
IN, max
; open collector or equivalent,
Negative Logic: device code suffix “1”
Logic Low = module On, Logic High = module Off
Positive Logic: No device code suffix required
Logic Low = module Off, Logic High = module On
Logic Low - Remote On/Off Current (V
Logic Low - On/Off Voltage
Logic High Voltage (I
on/off
= 0Adc)
Logic High maximum allowable leakage current
Turn-On Delay and Rise Times
(IO=80% of I
O, max
, TA=25°C)
Case 1: Input power is applied for at least 1second, and then the
On/Off input is set from OFF to ON (T
delay
= on/off pin transition until
VO = 10% of V
O, set
)
Case 2: On/Off input is set to Module ON, and then input power is
applied (T
delay
= VIN reaches V
IN, min
until VO = 10% of V
O,set
)
Output voltage Rise time (time for Vo to rise from 10%
of V
o,set
to 90% of V
o, set
)
(IO=80% of I
O, max
, VIN= 24 to 48Vdc, TA=25°C)
Output Overvoltage Protection
Input Undervoltage Lockout
Feature Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See
Feature Descriptions for additional information.

SHHD001A3B Hammerhead Series; DC-DC Converter Power Modules
18-75Vdc Input; 12Vdc, 1.3A, 15W Output
©2012 General Electric Company. All rights reserved.
Figure 1. Converter Efficiency versus Output Current.
Figure 2. Converter Input Current versus Input Voltage.
OUTPUT VOLTAGE
V
O
(V) (100mV/div)
OUTPUT CURRENT OUTPUT VOLTAGE
Io(A) (0.5A/div) V
O
(V) (100mV/div)
Figure 3. Typical output ripple and noise (Io = Io,max).
Figure 4. Transient Response to 0.1A/µS Dynamic Load
Change from 50% to 75% to 50% of full load, Vin=24V.
OUTPUT VOLTAGE On/Off VOLTAGE
V
O
(V) (5V/div) V
On/Off
(V) (2V/div)
OUTPUT VOLTAGE INPUT VOLTAGE
V
O
(V) (5V/div) V
IN
(V) (20V/div)
Figure 5.Typical Start-up Using Remote On/Off, negative
logic version shown (VIN = 24V or 48V, Io = I
o,max
).
Figure 6. Typical Start-up Using Input Voltage (VIN = 48V, Io =
Io,max).
Characteristic Curves
The following figures provide typical characteristics for the SHHD001A3 (12.0V, 1.3A) at 25oC. The figures are identical for either
positive or negative remote On/Off logic.