SEE THE COMPLETE PICTURE.
UNCOMPROMISED FIELD OF VIEW.
THOUGHTFULLY BUILT AROUND
AN UNCOMPROMISED MAGNET.
That’s just one of the things our customers are saying when they see a clinical
image from our Discovery MR750w wide bore system for the first time. It’s the
highest praise we could ask for, recognizing a fundamental philosophy that has
motivated us to continue to build great MR technology for over 30 years. This
philosophy is responsible for how we design and build every component of the
Discovery MR750w to work together in harmony so you can see a complete
picture of your patients. Without compromise.
It all starts with the magnet. When it comes to delivering on the promise of 3.0T
image quality, while enhancing the openness and patient experience, no other
MR component has greater impact than the magnet. The Discovery MR750w
system features a compact, lightweight , superconducting magnet designed to
provide excellent homogeneity and ensure uniform signal and fat-suppression
over a large, uncompromised imaging volume. This system’s magnet also
supports a large 50 x 50 x 50 cm field of view (FOV), which may reduce exam
times since fewer acquisitions are required to cover large anatomy.
With the powerful 3.0T magnet as its foundation, the Discovery MR750w
provides a robust combination of technologies for an uncompromised field
of view.
See for yourself how we put it all together.
Remarkable. What great coverage and image quality.
“
GRADIENT TECHNOLOGY
RF TRANSMIT AND RECEIVE
MAGNETIC FIELD HOMOGENEITY
HIGH PERFORMANCE
GRADIENTS.
REDEFINING SPEED, ACCURACY AND REPRODUCIBILITY.
Dual Echo Liver Assessment
When test driving a car, do you measure the performance of the engine simply
based on horsepower? Of course not. You measure it by how fast you can get
from the dealership to the highway and how well it handles along the way.
So why not apply that same logic to MR?
In fact, that’s how technologists do it today. When setting up a scan, they
don’t select the gradient amplitude and slew rate. They select scan parameters,
such as the sequence TR and TE, to generate the required clinical image contrast.
While the Discovery MR750w gradient system achieves high temporal
resolution and helps you drive the high patient throughput you desire,
it’s about more than just speed. The accuracy and linearity of the gradients
are required to support a true, uncompromised 50 x 50 x 50 cm field of view
and high resolution off of isocenter.
This high standard of gradient performance can be found on every
Discovery MR750w.
3D Gradwarp
The robust gradients of the Discovery
MR750w allow you to capture the first
out-of-phase TE at 1.1 ms consistently
with excellent resolution.
Reduce image distortion by
correcting for gradient field
non-linearities in all three
directions, leading to more
spatial accuracy in the
resulting image.