GE
Transportation
Its track-proven technology and years of reliability have made
the GE Vital Logic Controller a rail industry leader in solid state
interlocking control in North America.
The multi-purpose VHLC provides control of power switch
machines and DC lighting of signal lamps. It offers a direct
interface to Electro Code track circuits and the DC track relays
for the plant tracks and provides internal code emulation of
most code system protocols.
The VHLC replaces most vital and non-vital relays at an
interlocking. Its software package, Logic Station (ACE), allows
signal design engineers to program vital signal logic for the
VHLC using relay logic diagrams.
The basic VHLC system consists of the chassis, power supply,
Vital Logic Processor, Auxiliary Communication Processor, and
Site Specific Module. Various configurations for different code
system emulations are available.
Vital Logic Controller VHLC
A Leader in Interlocking Control
VHLC Components
Serial Interface Modules
Specifications
The VHLC chassis has positions for up to
12 modules. Of these 12 slots, 9 can be
configured with various combinations of
input/output modules as required for a
specific application. Vital serial links allow
up to 3 separate VHLC chassis to be
connected together providing additional
expansion.
Vital Logic Processor (VLP)*
Auxiliary Communications Processor (ACP)*
Site Specific Module (SSM)*
+5 Volt Power Supply*
Coded Circuit Interface (CCI)
Allows interface to one or two Electro
Code track interface chassis (8 track
circuits) and provides 16 coded outputs
to drive cab signal converters.
Vital Signal Driver (VSD)
Provides 16 outputs for DC control of
signal lamps. Hot and cold lamp
filament tests allow detection of
burned-out signal lamps.
Vital General Purpose Input/Output (VGPIO)
Contains 8 vital inputs and 8 vital
outputs.
Various serial interface modules provide
communications capability with carrier,
modems, data radio and wire line.
RS-232 Serial Interface
Dual Port RS-232 Module
RS-422/485 Module
HLC Modem Module
DC Code Line Interface Module
Current Loop Adapter Module
Accessories
Electro Code Track Interface
The Electro Code track interface
chassis receives, monitors, and
transmits track signals. It can hold
four Electro Code track interface
circuits. Each VHLC chassis can
interface with two of these chassis
providing eight Electro Code track
circuits.
The following circuit modules are
available:
Track Filter Module (9H)
Regulated Track
Converter Module (2R)
Track Receiver Module (7K)
Line Modules (2L, 7L, and 9L)
Filter Module (214)
Cab Signal Filter Module (CSF-XX-TC)
Electrical
Voltage: 10 to 16 VDC
Operating Temperature
Minimum: -40ºF (-40°C)
Maximum: +158ºF (+70°C)
Relative Humidity
95%, non-condensing
Dimensions
Height: 13 in (330.2 mm)
Width: 19 in (483.0 mm)
Depth: 14 in (355.6 mm)
Weight
33 pounds (15.0 kg)
Visit us online at
www.getransportation.com
16 Vital General Purpose Input (16VGPI)
Contains 16 vital inputs.
8 Vital General Purpose Input (8VGPI)
Contains 8 vital inputs.
Non-vital Input/Output (NVIO)
Contains 16 nonvital inputs and 16
non-vital bipolar outputs.
32 Non-vital Input (32NVI)
Contains 32 non-vital inputs.
*Required for each VHLC Chassis
doc20032-C