GE DPSR610GG, DBLR333GGCC, DRSR495GGWW, DWSR463GGWW, DBSR463GGWW Installation Instructions Manual

...
I
06
G
S
N
E
D
Installation Instructions
If you have any questions, call 1-800-GECARES (US) or 1-800-361-3400 (Canada)
or Visit our Web site at:
BEFORE YOU BEGIN
Read these instructions completely and
carefully.
IMPORTANT-
instructions for local inspector’s use.
IMPORTANT-
all governingcodes and ordinances.
Note to Installer - Be sure to leave
these instructions with the customer.
Note to Customer -
instructions with your Use and Care Book for future reference.
Before the old dryer is removed from service or discarded, remove the dryer door.
Inspect the dryer exhaust outlet and
straighten the outlet walls if they are bent.
Service information and the wiring dia-
gram are located in the control console.
Do not allow children on or in the appliance. Close supervision of child­ren is necessary when the appliance is used near children.
Install the dryer where the temp-
erature is above 50°F for satisfactory operation of the dryer control system.
Save these
Observe
Keep these
Gas Dryer
www. GEAppliances.com
WARNING
To reduce the risk of severe injury or death, follow all installation instructions.
Clothes dryer installation must be performed by a qualified installer.
Install the clothes dryer according to these instructions and in accordance with
local codes. In the absence of local codes, installation must comply with National Fuel Gas Code, ANSIZ223.1/NFPA 54 or the Canadian Natural Gas and Propane Installation Code, CSA B149.1.
California Safe Drinking Water and Toxic Enforcement Act
This act requires the governor of California to publish a list of substances known to the state to cause cancer, birth defects or other reproductive harm and requires businesses to warn customers of potential exposure to such substances. Gas appliances can cause minor exposure to four of these substances, namely benzene, carbon monoxide, formaldehyde and soot, caused primarily by the incomplete combustion of natural gas or LP fuels. Properly adjusted dryers will minimize incomplete combustion. Exposure to these substances can be minimized further by properly venting the dryer to the outdoors.
This dryer must be exhausted to the outdoors.
Use only 4” rigid metal ducting for exhausting the clothes dryer to the outdoors.
DO NOT install a clothes dryer with flexible plastic ducting materials. If flexible
metal (semi-rigid or foil-type) duct is installed, it must be UL-listed and installed in accordance with the instructions found in "Connecting The Dryer To House Vent" on page 6 of this manual. Flexible ducting materials are known to collapse, be easily crushed, and trap lint. These conditions will obstruct dryer airflow and increase the risk of fire. Do not install or store this appliance in any location where it could be exposed to
water and or weather. Save these instructions. (Installers: Be sure to leave these instructions with the
customer).
In the state of Massachusetts, installation must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by the state.
RISK OF FIRE
C
E
D
R
E
I
T
F
I
TOOLS YOU
WILL NEED
(x2)
10" ADJUSTABLE WRENCHES
KIT WX08X10077 (INCLUDES 2 ELBOWS)
8" PIPE WRENCH
SLIP JOINT PLIERS
New Dryer (see section 1).
Step 3 Check and Insure the Existing External Exhaust is
Clean (see section 1) and Meets Attached Installation
Specifications (see section 6). Step 4 Remove the Foam Shipping Pads (see section 1). Step 5 Move the Dryer to the Desired Location. Step 6 Level Your Dryer (see section 8). Step 7 Connect the Gas Supply (see section 3) and check
for leaks (see section 4).
FLAT BLADE SCREWDRIVER
LEVEL
4" DIA. METAL DUCT
(RECOMMENDED)
4" DIA. FLEXIBLE METAL (SEMI-RIGID)
UL LISTED TRANSITION DUCT
(IF NEEDED)
4" DIA. FLEXIBLE METAL (FOIL TYPE)
UL LISTED TRANSITION DUCT
(IF NEEDED.)
MATERIALS YOU WILL NEED
4" DIAM METAL ELBOW
4" DUCT CLAMPS
OR
4" SPRING CLAMPS
Step 8 Connect the External Exhaust (see section 7). Step 9 Connect the Power Supply (see section 5). Step 10 Check the Operation of the Power Supply, Gas
Connections, and Venting.
Step 11 Place the Owners Manual and the Installation
Instructions in a Location Where They Will Be Noticed By the Owner.
For Alcove or Closet Installation see section 9. For Bathroom or Bedroom Installation see section 10. For Mobile or Manufactured Home see section 11.
EXHAUST HOOD
(x2)
DUCT TAPE
(x2)
FLEXIBLE GAS LINE CONNECTOR
PIPE
COMPOUND
FOR LEAK DETECTION
SAFETY GLASSES
SOAP SOLUTION
GLOVES
Installation Instructions
WARNING
DRYER GAS SUPPLY CONNECTION
2"
2-5/8"
3/8" NPT MALE THREAD GAS SUPPLY
NOTE: Add to vertical dimension the distance between cabinet bottom to floor.
GAS SUPPLY
A 1/8-in.National Pipe Taper thread plugged tapping, accessible for test gauge connection, must be installed immediately upstream of the gas supply connection to the dryer. Contact your local gas utility should you have questions on the installation of the plugged tapping. Supply line is to be 1
You must use with this dryer a flexible metal connector
/2-in. rigid pipe and equipped with an accessible shut-off within 6 ft. of, and in the same room with the dryer.
••Use pipe thread sealer compound or Teflon tape
appropriate for natural or LP gas.
listed connector ANSI Z21.24 / CSA 6.10. The length of the connect shall not exceed 3 ft.
Minimum Clearance Other Than Alcove or Closet Installation
Minimum clearance to combustible surfaces and for air opening are: 0 in. clearance both sides and 1 in. rear. Consideration must be given to provide adequate clearance for proper operation and service.
1 PREPARING FOR INSTALLATION OF NEW DRYER
TIP: Install your dryer before installing your washer. This will allow better access when installing dryer exhaust.
DISCONNECTING GAS
TURN GAS SHUT-OFF VALVE TO THE OFF POSITION.
DISCONNECT AND DISCARD OLD FLEXIBLE GAS CONNECTOR AND OLD TRANSITION DUCTING MATERIAL. REPLACE WITH NEW CSA(AGA) APPROVED FLEXIBLE GAS LINE CONNECTOR AND UL APPROVED TRANSITION DUCT.
WARNING - NEVER REUSE OLD FLEXIBLE CONNECTORS.
The use of old flexible connectors can cause leaks and personal injury. Always use new flexible connectors when installing gas appliances.
2 GAS REQUIREMENTS
Installation must conform to local codes and ordinances, or in their absence, the NATIONAL FUEL GAS CODE, ANSI Z223.
This gas dryer is equipped with a Valve & Burner Assem­bly for use only with natural gas. Using conversion kit WE2 5X0217, your local service organization can convert this dryer for use with propane (LP) gas. ALL CONVER­SIONS MUS T BE M A DE BY PR OPER LY TRA INED AND QUALIFIED PERSONNEL A ND IN ACCOR­DANCE WITH LOCAL CODES AND ORDINANCE REQUIREMENTS.
The dryer must be disconnected from the gas supply piping system during any pressure testing of that system at a test pressure in excess of 0.5 PSI (3.4 KPa).
The dryer must be isolated from the gas supply piping system by closing the equipment shut-off valve during any pressure testing of the gas supply piping of test pressure equal to or less than 0.5 PSI (3.4 KPa).
REMOVING LINT FROM WALL
EXHAUST OPENING
Remove and discard existing plastic or metal foil
transition duct and replace with UL listed transition duct.
WALL
INTERNAL DUCT OPENING
CHECK THAT EXHAUST HOOD DAMPER OPENS AND CLOSES FREELY.
TILT THE DRYER SIDEWAYS AND REMOVE THE FOAM SHIPPING PADS BY PULLING AT THE SIDES AND BREAKING THEM AWAY FROM THE DRYER LEGS. BE SURE TO REMOVE ALL OF THE FOAM PIECES AROUND THE LEGS.
••Connect flexible metal connector to dryer and gas supply.
Open shut-off valve.
2
3
4 LEAK TEST
Installation Instructions
3 RECONNECTING GAS
Listed connector ANSI Z21.24 / CSA 6.10
FLARE
Note: The connector and fittings are designed for use only on the original installation and are not to be reused for another appliance or at another location. Keep flare end of adaptor free of grease, oil and thread sealant.
Caution: Use adapters as shown. Connector nuts must not
be connected directly to pipe threads.
NPT
3/8" NPT
1/8" NPT PIPE PLUG FOR CHECKING GAS INLET PRESSURE
PIPE SIZE
PIPE SIZE AT LEAST 1/2"
TIGHTEN ALL CONNECTIONS USING TWO ADJUSTABLE WRENCHES.
DO NOT OVERTORQUE GAS CONNECTIONS!
TIGHTEN THE FLEXIBLE GAS LINE USING TWO ADJUSTABLE WRENCHES.
Loading...