MODEL “PG-BDL-CL”
SERIES FILTER HOOD
GENERAL SPECIFICATIONS
Furnish Gaylord Exhaust Hood Model “PG-_____-BDL-CL-_____” as
shown on plans and in accordance with the following specifications:
GENERAL: Each exhaust hood shall be designed specifically for the
cooking equipment being covered.
The exhaust hood shall include a stationary grease collecting gutter at
the bottom of the grease extraction device, sloped to a drain at one end
to a removable stainless steel grease cup. The sloped gutter shall be
concealed by an apron which extends the full length of the hood.
Continuous front and rear brackets shall be provided to facilitate
hanging from the overhead building structure. Each exhaust hood shall
contain one or more stainless steel baffle filters. Filters shall be self
draining, UL classified and mounted no less than a 45° angle from
horizontal.
o Fuse Link Activated Fire Damper (Series Prefix PG) The exhaust
hood shall include a fire damper located at the exhaust duct collar. The
damper shall be activated by fuse link(s), and upon activation, the
damper shall close, and act as a fire barrier to prevent flame from
entering the duct system. The damper shall be manually reset without
the use of tools and without opening or removing access panels. The
exhaust hood shall be UL listed under the category “Exhaust Hood with
Exhaust Damper.”
o Exhaust Hood without Fire Damper (Optional - Series Prefix
PG-ND) The exhaust hood shall be UL listed under the category
“Exhaust Hood without Exhaust Damper.”
CONSTRUCTION: The ventilator shall be of all stainless steel construction, not less than 18 gauge, type 300 series. All exposed surfaces
shall be a number 4 finish. The use of aluminized steel, galvanized steel,
or 430 stainless steel is not acceptable.
LIGHT FIXTURES: The exhaust hood shall be equipped with o 100
watt surface mounted incandescent, o 150 watt recessed incandescent, o recessed fluorescent, light fixtures. Light fixtures shall be
factory pre-wired to a single connection point. Exhaust hoods built in
multiple sections shall be furnished with coiled flex conduit for interconnecting sections, in the field by others.
ACCEPTANCE & APPROVALS: The exhaust hood shall be UL, CUL
and NSF listed. The exhaust hood shall comply with all requirements of
NFPA-96, IMC, UMC, BOCA, and SBCCI model codes.
ITEM NO. _______________
APPLICATION
Used for cafeteria lines or single island arrangements when covering
light, medium or heavy duty cooking equipment. (Note 400 CFM/Lineal
Ft. maximum exhaust volume). Not to be used over gas or solid fuel
char broilers.
FEATURES
• UL, CUL and NSF Listed
• “Super Capture”TM Lip - Enhances Capture
and Reduces Exhaust Volume
• Complies With The IMC, UMC, BOCA and
SBCCI Mechanical Codes
• Complies With All Requirements of NFPA-96
OPTIONAL ACCESSORIES
• Decorative Facings and Trim
• Built-in Light & Fan Switch
• Built-in Fire Extinguishing Systems
DESCRIPTION
The Gaylord “PG” series exhaust hood is an economy hood that
maintains the “standards” in materials, construction and quality found
in all Gaylord Water-Wash and Non Water-Wash high efficiency
extractor ventilators. The “PG” series hood uses stainless steel baffle
filters as a standard. A fuse link activated fire damper is standard, or
the hood may be provided without a fire damper.
The “PG” series has been tested to UL standard 710 and is listed either
under the category “Exhaust Hood with Exhaust Damper” or “Exhaust
Hood without Exhaust Damper.”
OPTIONAL EQUIPMENT
1. Exhaust Fans, Supply Fans, & Roof Top Units
2. Fire Extinguishing Systems
3. Utility Distribution Systems
4. Pollution Control Systems
GAYLORD INDUSTRIES
10900 S.W. AVERY STREET • TUALATIN, OREGON 97062 U.S.A.
PHONE: 800-547-9696 • FAX: 503-692-6048 • email: info@gaylordusa.com
www.gaylordusa.com
MODEL “PG - ____ -BDL - CL - ____”
ND
DEPTH
OF
VENTILATOR
For exact model designation add appropriate suffixes.
Example: “PG-BDL-CL-54”
ITEM NO. ______________________ EST. WT. _________________________
LENGTH _____________ WIDTH ______________ HEIGHT ______________
EXHAUST - CFM ________________ DUCT SIZE ____________ S.P. ______
LIGHTS VOLTAGE
qq
100W SURFACE INCANDESCENT
q
qq
qq
150W RECESSED INCANDESCENT
q
qq
q q
RECESSED FLUORESCENT
q
q q
q q
120 VOLTS
q
q q
q q
220/240 VOLTS
q
q q
The manufacturer reserves the right to
modify the materials and specifications resulting from a continuing program of product improvement or the
availability of new materials
TYPICAL SECTION VIEW
ENGINEERING DATA
Mechanical Requirements
Model PG-BDL-CL Series may be used on light and medium duty equipment
only (400 CFM per lineal ft.). Refer to the Master Engineering Data Sheet
in the Engineering Data section of the Gaylord catalog for the charts on
determining exhaust volume, duct sizes, and static pressure.
Electrical
A Gaylord stop/start switch, Model C-150, may be provided as an option for
each exhaust fan. Lights to be on separate circuit, 120 volt standard, 220/
240 volt optional.
Form No. PG-BDL-CL 0307 / 30722 © Copyright 2007, Gaylord Industries Litho USA
Ventilator Lengths
Maximum unit length 16'-0". For greater lengths, join two or more sections
together. Check to ensure that there is adequate access into building and
kitchen area.
Note: Ventilators manufactured outside North America; maximum unit length
*
10'-0".
Hanging Weight
Ventilator Width 48" 54" 60"
Wt. / Lineal ft. Lbs. 70 75 80