69443-xxx Main PCBA.................................................................................................................................. 4
+48 Volt Power Supply.......................................................................................................... ........................ 4
+12 Volt Power Supply.......................................................................................................... ........................ 4
Power Connections........................................................................................................................................ 8
Data Link Technology used with LE200 Line Extenders............................................................... 24
T1/E1 Digital Link....................................................................................................................................... 24
Low Voltage Differential Signaling (LVDS) Data Link................................................................................ 24
Setting up th e Data Link(s)........................................................................................................................... 24
T1 Data Link Settings.......................................................................................................... ........................ 25
LVDS Data Link Settings.............................................................................................................................28
LVDS Port In dicators...................................................................................................................................28
Fiber Optic Modem Set-Up (Models LE200-FSR and LE200-FLR)..............................................29
Loopback Test Switch.................................................................................................................................. 30
Confidentiality Notice:This document c ont ains s ens it ive business and technical information w hic h is conf ident ial and propriet ary t o t he GAI - T ronic s
Corporation. The inform at ion c ont ained in t his docum ent is intended s olely for internal use by GAI-Tronics personnel, and is not to be disclosed in any form, in
whole or in part, directly or indirect ly , to any third part y.
ii
PUB.42004-701L2F
GAI-TRONICS® CORPORATION
A HUBBELL COMPANY
Model LE200 Series Wall-Mount
Page/Party
®
Line Exte nders
Confidentiality Notice
This manua l is provide d sole ly as an operatio nal, installation, and ma inte nance guide and conta ins
sensitive business and t e chnical informatio n tha t is confidentia l and pr opri et ary to GAI- Tronics. GAITronics retains all intellectual property and other rights in or to the information contained herein, and
such information may on ly be u sed in conn e ction with the operatio n of you r GAI-Tr onics p rodu c t or
system. This manu al may not be dis clos e d in any form, in whole or in pa rt, direct ly or i ndir ectly, to a ny
third pa r ty.
General Information
Product Overview
The Model LE200 Series Wall Mount Page/Party® Line Extenders are used in pairs to provide transparent
extension or expansion of both conventional and SmartSeries Page/Party
system by linking a local and distant Page/Party
field devices' line loading to be spread across multiple Page/Party
®
system cable. It can expa nd the system by allowing the
®
®
systems. It ca n extend the
system cables.
System Requirements and Limitations
Two electrically isolated Page/Party® or SmartSeries systems are required.
Features and Functions
The Model LE200 Series Page/Party® Line Extenders provide the following features between Page/Party®
system cables:
• Half-duplex page line audio transmission • A page line ground fault detected contact output
• A page line audio 600-ohm monitor output • One digital link using T1 or E1 technology
• A page line a udio detected contact output • Two digital links using LVDS technology
• Bi-directional page line 50 kHz VLC
transmission
• Bi-directional pa ge line Sma rtSeries FSK
transmission
• Unidirectional page line ground fault
transmission
• Bi-d irectional cont act c losure tr ansmission, for
five contact closure inputs
• Full du plex par ty line au dio trans mis sion, for all
five party lines
•Unidirectional party line off-hook transmission
GAI-Tronics Corporation 400 E. Wyomissing Av e. Mohnton, PA 19540 USA
610-777-1374 800-492-1212 Fax: 610-796-5954
ISIT WWW.GAI-TRONICS.COM FOR PRODUCT LITERATURE AND MANUALS
V
Pub. 42004-701L2F
M
ODEL LE200SERIES WALL-MOUNT PAGE/PARTY® LINE EXTENDERS PAGE 2 of 50
Figure 1. Model LE200 Outline Detail
Figure 2. Interior View of Components - Model LE200 (Enclosure shown open)
f:\standard ioms - current releas e\ 42004 ins t r. manuals\42004-701l2f.doc
04/09
Pub. 42004-701L2F
M
ODEL LE200SERIES WALL-MOUNT PAGE/PARTY® LINE EXTENDERS PAGE 3 of 50
Figure 3. Interior View of Components - Models LE200-FSR and LE200-FLR (Enclosure shown open)
f:\standard ioms - current releas e\ 42004 ins t r. manuals\42004-701l2f.doc
04/09
Pub. 42004-701L2F
M
ODEL LE200SERIES WALL-MOUNT PAGE/PARTY® LINE EXTENDERS PAGE 4 of 50
Subcomponent Descriptions
Enclosure
The Model LE200 Series enclosures contain:
• The 69441-xxx Audio Terminal PCBA as part of the 13118-011
• The 69442-xxx I/O Terminal PCBA as part of the 13118-012
• The 69443-xxx Main PCBA
• The +48 volt power supply
• A +12 volt power supply (Models LE200-FSR and LE200-FLR only)
• A fiber modem (Models LE200-FSR and LE200-FLR only)
• Grounding connections
• Input power terminals containing 15-amp circuit breakers
69441-xxx Audio Termin al PCBA
The 69441-xxx printed circuit board is used to terminate the page and party lines of the system cable.
The 69441-xxx includes over voltage protection and line balance potentiometers for the page line and all
five party lines. Refer to Figure 5.
69442-xxx I/O Termin al PCBA
The 69442-xxx printed circuit boa r d is used to terminate the contact inputs and contact outputs. The
69442-xxx contains the relays for the contact outputs, and signal conditioning comp onents for the contact
inputs. Refer to Figure 5.
69443-xxx Main PCBA
The 69443-xxx printed circuit board contains the main logic of the Model LE200. Refer to Figure 4.
Fiber Optic Mod em Models
The Models LE200-FSR, LE200-FSR-E1, LE200-FLR and LE200-FLR-E1 include a third party fiber
modem that converts the copper T1 or E1 signals to fiber optic T1/E1 signals and vice ver sa .
• Model LE200 FSR (Multi-Mode Fiber, T1 signals)
• Model LE200 FLR (Single Mode Fiber, T1 signals)
• Model LE200-FSR-E1 (Multi-Mode Fiber, E1 signals)
• Model LE200-FLR-E1 (Single Mode Fiber, E1 signals)
+48 Volt Power Supply
The Model LE200 is powered by a +48 V power supply. A selector switch allows the power supply to
operate at either 115 V ac or 230 V ac.
+12 Volt Power Supply
The Model LE200-FSR/FLR contains a +12 V power supply for the fiber optic module. It has an
operation range from 90 V ac to 264 V ac.
f:\standard ioms - current releas e\ 42004 ins t r. manuals\42004-701l2f.doc
04/09
Pub. 42004-701L2F
M
ODEL LE200SERIES WALL-MOUNT PAGE/PARTY® LINE EXTENDERS PAGE 5 of 50
Figure 4. 69443-xxx Main PCBA
f:\standard ioms - current releas e\ 42004 ins t r. manuals\42004-701l2f.doc
04/09
Pub. 42004-701L2F
M
ODEL LE200SERIES WALL-MOUNT PAGE/PARTY® LINE EXTENDERS PAGE 6 of 50
f:\standard ioms - current releas e\ 42004 ins t r. manuals\42004-701l2f.doc
04/09
Pub. 42004-701L2F
M
ODEL LE200SERIES WALL-MOUNT PAGE/PARTY® LINE EXTENDERS PAGE 7 of 50
Installation
ATTENTION
Instal lation s ho uld be performed by qua l ified service perso nnel only in
accordance w it h the Na tional Electri cal Code or applicabl e local codes.
Mounting
1. Unlock the front door of the enclosure using a screwdriver by rotating the lock a quarter turn
counterc loc kwise, and open t he front d oor, which is hinged on the l e ft.
2. Disconnect the ribbon cables and the ground wire connections from the interior rear panel. Remove
the four bolts that hold the rear panel in place, and set this assemb ly and the bolts aside in a safe
location.
3. Position the enclosure on the mounting surface. The enclosure provides four 0.50-inch mounting
holes. Secure it with four 3/8-inch diameter bolts of the appropriate lengths for the mounting surface,
flat washers and nuts. To ensure proper sealing and enclosure protection rating, use the provided
sealing washers. Install the sealing washers inside the enclosure with the tapered cone against the
enclosure and then add the flat washer s. See Figure 6 for installation details.
4. Prepare the enclosure for cable entry. For example, if conduit is installed, create an access hole using
a metal hole punch that is equivalent in size to the conduit diameter.
5. Re-install the rear panel assembly using the four bolts removed previously. Re-attach the ribbon
cab le connectors and th e grou nd wires.
6. Pull the cables into the enclosure, and make connections per the wiring section.
7. Complete the installation by closing the front door and relocking the enclosure.
Figure 6. Mounting Details
f:\standard ioms - current releas e\ 42004 ins t r. manuals\42004-701l2f.doc
04/09
Pub. 42004-701L2F
M
ODEL LE200SERIES WALL-MOUNT PAGE/PARTY® LINE EXTENDERS PAGE 8 of 50
Wiring
The Model LE200 provides the interfaces for customer connections described below. All of the
terminations on the PCBAs support a wire size range of No. 24 AWG to 12 AWG.
Figure 7. Wiring Connections
Power Con nections
WARNING
The input voltage selector switch must be in the appropriate position before
power is ap plied to the Line Extender.
The Line Extender provides a double-pole circuit breaker for the input power. This input voltage may be
set to either 115 V ac at 50/60 Hz or 230 V a c at 50/60 Hz via an input selector switch, which is located
on the +48 V Power Supply.
A ground and spare terminal block are located next to the double-pole circuit breaker. The orange wire
found in GAI-Tronics system cab l e can b e terminated at t his spare terminal.
f:\standard ioms - current releas e\ 42004 ins t r. manuals\42004-701l2f.doc
04/09
Pub. 42004-701L2F
M
ODEL LE200SERIES WALL-MOUNT PAGE/PARTY® LINE EXTENDERS PAGE 9 of 50
Table 1. Data Link on 69443-xxx PCBA
Terminal Designator Description
P19-1 Data Link TX Ring
Da ta TRANSMIT wir e pair
P19-2 Data Link TX Tip
P19-3 Data Link RX Ring
Data RECEIVE wir e pair
P19-4 Data Link RX Tip
Table 2. Page Line Monitor Output on 69443-xxx PCBA
Terminal Designator Description
P16-1 PG MON L2 Page line monitor audio output (L2)
P16-2 - No connection
P16-3 PG MON L1 Page line monitor audio output (L1)
®
Table 3. Page/Party
System Cable Connection on 69441-xxx PCBA
Refer to Figure 2 on page 2 for location of the 69441-xxx PCBA.
Terminal Designator Description
P5-1/P8-1 PAGE L1
Pa ge line audio
P5-2/P8-2 PAGE L2
P5-3/P8-3 PL1 L1
Party Line 1 audio
P5-4/P8-4 PL1 L2
P5-5/P8-5 PL2 L1
Party Line 2 audio
P5-6/P8-6 PL2 L2
P5-7/P8-7 PL3 L1
Party Line 3 audio
P5-8/P8-8 PL3 L2
P5-9/P8-9 PL4 L1
Party Line 4 audio
P5-10/P8-10 PL4 L2
P5-11/P8-11 PL5 L1
Party Line 5 audio
P5-12/P8-12 PL5 L2
f:\standard ioms - current releas e\ 42004 ins t r. manuals\42004-701l2f.doc
04/09
Pub. 42004-701L2F
M
ODEL LE200SERIES WALL-MOUNT PAGE/PARTY® LINE EXTENDERS PAGE 10 of 50
Table 4. Auxiliary Inputs on 69442-xxx PCBA
Refer to Figure 2 on page 2 for location of the 69442-xxx PCBA.
Terminal Designator Description
TB8 Input 1 (+)
Auxiliary input contact 1
TB8 Input 1 (-)
TB8 Input 2 (+)
Auxiliary input contact 2
TB8 Input 2 (-)
TB8 Input 3 (+)
Auxiliary input contact 3
TB8 Input 3 (-)
TB9 Input 4 (+)
Auxiliary input contact 4
TB9 Input 4 (-)
TB9 Input 5 (+)
Auxiliary input contact 5
TB9 Input 5 (-)
Table 5. Page Line Audio Detector Output on 69442-xxx PCBA
f:\standard ioms - current releas e\ 42004 ins t r. manuals\42004-701l2f.doc
04/09
Pub. 42004-701L2F
M
ODEL LE200SERIES WALL-MOUNT PAGE/PARTY® LINE EXTENDERS PAGE 12 of 50
Fiber Optic Cable Connections
The Line Extender provides a pair of ST fiber optic connectors (one for the transmit fiber and one for the
receive fiber). Typical connections for this method are shown in Figure 9.
Figure 8. Fiber Optic Transceiver
Figure 9. Typical Fiber Optic Data Link Connection
f:\standard ioms - current releas e\ 42004 ins t r. manuals\42004-701l2f.doc
04/09
Pub. 42004-701L2F
M
ODEL LE200SERIES WALL-MOUNT PAGE/PARTY® LINE EXTENDERS PAGE 13 of 50
Operation
The Model LE200 Page/Party® Line Extender r equires no user interface after successful installation and
testing.
Description of F eatures
Page Line Audio Transmission
A pair of Model LE200s provides page line audio transmission between two Page/Party® system cables.
This transmiss ion is half-dupl ex oper atio n.
Half-Dupl ex Operation
When the Model LE200 detects a peak audio level equal or above a Peak Voltage Level Detection
Threshold
Time.
until it is continuously below the Peak Voltage Level Detection Threshold for the Transmission Direction
Hold Time. The DIP s w itch, SW2, loc ate d on the Main P C boar d select s Peak Voltage Level Detecti o n
Threshold and Transmission Direction Hold Time. Refer to Table 8 and Table 9 for switch setting
options.
, it immediately switches audio “on” in that direction for the Transmission Direction Hold
Audi o f rom the other direct ion is muted and ignored during that time. Audio is not switched “of f”
Training the Echo Cancellation
Overview
Line echo (also known as electric or hybrid echo) is created by the electrical circuitry connected to a twowire (full duplex) audio system. Echo is inherent in all full-duplex audio systems and is affected by the
audio line length and line impedance mismatches. The presence of audible echoes results in undesirable
audio qua lity. This kind of qual ity degradati on is inhere nt in t h e netw ork equip me nt an d e nd-u ser phone
devices.
To minimize echo, the Model LE200 performs an echo cancellation training sequence on party lines 1
through 5 . The echo ca ncellatio n training tak es approxi mate ly 15 seconds and is perf ormed aut omatically
one minute after power is applied to the LE200. This delay allows all power levels to stabilize prior to
perfor mi ng ech o c ancellation tra i ning. Echo cancellat i on can be manu all y initiated as described below.
OTE: Signal impulses are transmitted onto the audio lines during the echo cancellation training
N
sequence. Handset stations that are in use on a party line will hear the signa ls in the handset receiver. For
troubleshooting purposes, the one-minute delay may be disabled by closing DIP switch SW6-1.
Manual In itiation of E cho Cancelin g
Press and release push button PB1 on the main PC board three times. The push button must be pr essed
for at lea st one quarter second and no more than two seconds each time. The timing requirement is meant
to prevent accidental requests. If an error is made with the push-button timing, the sequence must be
repeated from the beginning.
The main board LEDs will indicate the progress of the echo canceling sequence. One column of LEDs
turns on after each push button press or release until the sequence is started. Once the sequence is started,
those LED s rema in on, and a c ountd own timer is disp layed on th e rema ining L EDs. The LED s return t o
normal op eration after the echo c ancellat ion training seque nce is complete.
f:\standard ioms - current releas e\ 42004 ins t r. manuals\42004-701l2f.doc
04/09
Pub. 42004-701L2F
M
ODEL LE200SERIES WALL-MOUNT PAGE/PARTY® LINE EXTENDERS PAGE 14 of 50
Table 8. Transmission Direction Hold Time on 69443-xxx PCBA
SW2-5 SW2-6 Transmission Direction Hold Time
Open (up)* Open (up)* 1280 milliseconds
Closed (down) Open (up) 640 milliseconds
Open (up) Closed (down) 160 milliseconds
Closed (down) Closed (down) 40 milliseconds
NOTE: Changes to this parameter take effect without cyc ling power.
Table 9. Peak Voltage Level Detection Threshold on 69443-xxx PCBA
SW2-7 Peak Voltage Level Detection Threshold
Open (up)* -12 dB relative to nominal
Closed (down) -24 dB relative to nominal
NOTE: Changes to this parameter take effect without cyc ling power.
Table 10. Echo Cancellation Power-On Delay Setting on 69443-xxx PCBA
SW6-1 Echo Cancellation Power-On Delay
Open* One minute
Closed No delay
NOTES: 1. Changes to this parameter take effect when cycling power.
2. *Indicates default position.
f:\standard ioms - current releas e\ 42004 ins t r. manuals\42004-701l2f.doc
04/09
Loading...
+ 37 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.