Gai-tronics DEX-203, DEX-103 User Manual

Pub.: 42004-692L2C
GAI-TRONICS® CORPORATION
A HUBBELL COMPANY
Model DEX-103 and DE X-203
T ABLE OF C ONTENTS
Confidentiality Notice.....................................................................................................................1
General Information.......................................................................................................................1
Product Overview...................................................................................................................................1
System Requirements and Limitations.................................................................................................1
Features and Functions..........................................................................................................................2
Available Models.....................................................................................................................................2
Description of Major Components........................................................................................................2
Installation ......................................................................................................................................3
General Information............................................................................................................................... 3
Mounting..................................................................................................................................................5
Conduit Installation................................................................................................................................5
Field Wire Installation............................................................................................................................6
Power........................................................................................................................................................7
Model DEX-203 ...................................................................................................................................................7
Model DEX-103 ...................................................................................................................................................7
Auxiliary Devices....................................................................................................................................8
System Interconnection..........................................................................................................................9
Operation.......................................................................................................................................10
Intercom Communication Modes........................................................................................................10
Volume Control ..................................................................................................................................................11
Paging .................................................................................................................................................................11
Alarms and Music...............................................................................................................................................11
Maintenance..................................................................................................................................12
General Information............................................................................................................................. 12
Troubleshooting....................................................................................................................................12
Specifications ................................................................................................................................13
GAI-Tronics Corporation 400 E. Wyomissing Ave. Mohnton, PA 19540 USA
610-777-1374 800-492-1212 Fax: 610-796-5954
V
ISIT WWW.GAI-TRONICS.COM FOR PRODUCT LITERATURE AND MANUALS
Pub. 42004-692L2C
GAI-TRONICS® CORPORATION
A HUBBELL COMPANY
Model DEX-103 and DE X-203

Confidential ity Notice

This manual is provided solely as an operational, installation, and maintenance guide and contains sensitive business and technical information that is confidential and proprietary to GAI-Tronics. GAI­Tronics retains all intellectual property and other rights in or to the information contained herein, and such information may only be used in connection with the operation of your GAI-Tronics product or system. This manual may not be disclosed in any form, in whole or in part, directly or indirectly, to any third party.

General Information

Product Overview

The Driller’s Intercom is a communications system designed to serve the needs of oil and gas industry on oil drilling platforms, especially in hazardous areas. It provides all-call, group call, and point to point communications, and is available in digital and analog versions.
The enclosure is rated IP56, and is factory sealed to ensure explosion-proof integrity.

System Requirements and Limitations

Each Driller’s Intercom system requires a Central Switch to operate. The Central Switch must be located in a non-hazardous area. The configuration parameters for all components of the system are set in the Central configuration.
Each central switch can manage up to 16 digital or analog subscribers, and can be expanded to 32 subscribers. Central switches can be linked or a larger switch can be used for increased system size. By combining central switches, the system is easily expanded at any time.
All stations must be connected in a star configuration to the Central Switch, but power to the stations can be daisy-chained. Please refer to the “Installation” section for the power cable and system cable distance limitations.
Additional features and functions (not detailed in this manual) are available. Refer to the Central Switch manual or contact a GAI-Tronics Corporation representative for more details.
Figure 1. Driller’s Intercom with Keypad
GAI-Tronics Corporation 400 E. Wyomissing Ave. Mohnton, PA 19540 USA
610-777-1374 800-492-1212 Fax: 610-796-5954
V
ISIT WWW.GAI-TRONICS.COM FOR PRODUCT LITERATURE AND MANUALS
Pub.: 42004-692L2C
ODEL DEX-103 AND DEX-203 DRILLERS INTERCOM STATIONS Page 2 of 13
M

Features and Functions

120-240 V ac and 24 V dc models • Factory sealed
IP56 rated enclosure Suitable for Zone 1 & 2 Hazardous Areas
18-watt speaker amplifier • Suitable for high noise areas
Speaker volume control Hands-free duplex and simplex communication
Beacon control All-call and group paging
Footswitch input Broadcast of alarm and music signals
Call status indicator Master/slave and point-to-point communications
CE Mark System upgrade and expansion capability
ATEX 94/9/EC

Available Models

DEX-103 DEX-203
Digital Driller’s Intercom Station 24 V dc (ATEX)
Digital Driller’s Intercom Station 120-240 V ac (ATEX)

Description of Major Components

The Driller’s Intercom stations consist of a factory-sealed enclosure (top) and a termination enclosure (bottom). Refer to Figure 1 for details. The factory-sealed configuration eliminates the need for external seals on this unit; however, additional seals may be required on auxiliary devices.
The audio, control, and power components for this assembly are contained in the factory-sealed enclosure. The front panel of the factory-sealed enclosure contains the user interface components (microphone, status LED, and keypad [digital models only]).
All system terminations (power, speaker, system, footswitch, and beacon) are to be made in the termination enclosure.
This station requires an external speaker (sold separately) to operate. Also, a customer-supplied beacon (digital models only) and footswitch can be added to this unit for visual status indication and talk/listen control.
CAUTION
Use only suitably listed components for the hazardous area.
f:\standard ioms - current release\42004 instr. manuals\42004-692l2c.doc 11/10
Pub.: 42004-692L2C
ODEL DEX-103 AND DEX-203 DRILLERS INTERCOM STATIONS Page 3 of 13
M

Installation

General Information

WARNING
Always remove power to this station and any associated equipment before
beginning any installation.
Install equipment without modification and according to all applicable local and national electrical codes.
CAUTION
The factory-sealed section of this station is only to be opened for maintenance or repair by factory authorized personnel. Refer to the “Maintenance” section for more details.
WARNING
After installing station and before applying power, verify that the bolts on the factory-sealed section of the station are set at 30 ft-lbs.
This station has a highly sensitive microphone that allows the user to communicate at a distance from the station. This station also contains a high gain amplifier that enables operation in high noise environments.
To prevent feedback problems in the system, the ambient noise levels, volume settings, and station placement must be taken into consideration. In most cases, stations can be mounted perpendicular to the same surface and be placed 150 feet apart. This minimum spacing requirement between stations can be reduced under the following conditions:
the stations are installed in a high noise environment;
they are configured for simplex mode (depressing T button);
they contain speaker L-pads;
they are placed in separate rooms.
f:\standard ioms - current release\42004 instr. manuals\42004-692l2c.doc 11/10
Pub.: 42004-692L2C
ODEL DEX-103 AND DEX-203 DRILLERS INTERCOM STATIONS Page 4 of 13
M
Figure 2. Driller’s Intercom Outline
f:\standard ioms - current release\42004 instr. manuals\42004-692l2c.doc 11/10
Loading...
+ 10 hidden pages