Gaggenau VI424610 PRODUCT SPECIFICATIONS

VI 424 610
Stainless steel frame Width 15" (38 cm)
Installation accessories
In combination of several Vario cooktops or VL 414 downdraft, connecting strips must be used. Choose respective VA 420 strip from one of the below, depending on type of installation.
VA 420 010
Connection strip for surface-mount installation without appliance cover.
VA 420 011
Connection strip for surface-mount installation with appliance cover.
VA 420 000
Connection strip for flush installation without appliance cover.
VA 420 001
Connection strip for flush installation with appliance cover.
VA 440 010
Stainless steel cover with mounting strip
VA 450 400
Stainless steel adjustment strip, width 15". Necessary accessory in a combination of 15" Varios with at least one appliance cover to com­pensate for the appliance depth.
Optional accessories GP 900 001
Stainless steel frying pan Non-stick cooking, for ø 6" cooking zone.
GP 900 002
Stainless steel frying pan Non-stick coating, for ø 7" cooking zone.
GP 900 003
Stainless steel frying pan Non-stick coating, for ø 8" cooking zone.
Vario 400 series induction cooktop
VI 424
– 2 cooking zones with Power
boost function – Total output 3,600 W – Solid stainless steel control
knobs – Precision-crafted ⅛-inch
stainless steel frame – For surface-mount installation
with a visible edge or for flush
installation – Can be perfectly combined with
other Vario 400 series products
Cooking zones
One ø 8 ¼" induction cooking zone (2,200 W, 3,300 W with Power boost). One ø 5 " induction cooking zone (1,400 W, 1,800 W with Power boost).
Operation
Control knobs with illuminated ring, cooking zone and output level markings. Electronic control in 12 output levels.
Features
Cooking zone marking. Power boost function for each cooking zone (only one zone at a time can be operated with booster function) Pan detection. Short-term timer.
Safety
Individual residual heat indication. Safety lock.
Planning notes
Depending on the type of installation — surface-/ or flush-mounted, with or without cover — the specific location of the control knob positions may vary. When using the appliance cover VA 440 or adjustment strip VA 450 additional space for cut-out depth needs to be considered. In a combination of Vario cooktops with at least one appliance cover, the adjustment strip VA 450 is required. In a combination of several Vario 400 series cooktops a connection strip must be used. Depending on the type of installation — surface-/ or flush-mounted, with or without cover — the respective VA 420 connecting strip must be used. For flush installation the edge height in the cut-out needs to be at least ½" and for surface-mount ⅜" . Ensure a continuous cut surface of 90°. The weight capacity and stability, especially in case of thin countertops, must be supported using suitable substructures. Take the appliance weight and additional loads into account. Flush installation is possible in countertops made of stone, synthetics or solid wood. Heat resistance and watertight sealing of the edges must be observed. For other materials, please consult with your countertop manufacturer. The groove must be continuous and even, so that uniform placing of the appliance on the gasket is ensured. Do not use discontinuous lining.
The joint width may vary due to size tolerances of the combinations and of the countertop cut-out. If installing several Vario products in individual cut-outs allow for a minimum distance of 2" between the cooktops. Operates with magnetic (induction) iron pots and pans only. For an optimal heat distribution, the use of sandwich bottom cookware is recommended. Immersion depth 2 ⅝" – 2 ¾" depending on type of installation. Built-in control panel can be integrated in the bottom cabinet at drawer level. Front panel thickness " – 1". The adjacent drawing “Installation of the control knobs” must be observed if the panel is more than 1" thick (there must be a recess at the rear for proper control module installation). Appliance clicks into place when inserted into the countertop from above.
Please read additional planning notes on pages 72 – 79.
Rating
Total rating: 3.6 kW. Total Amps: 16. 208 / 220-240V / 60Hz Total connected load 3.6 kW. Plan for a 37" connecting cable without plug (hard wire required).
50 Vario cooktops
90°
1
/
8
"
(3.5
-0.5
)
R
1
/
8
" (3)
R
3
/
16 "
(5
+1
)
39" (1.0 m)
min. 1
3
/
8
" (35)
min. 4
1
/
4
" (109)
max. 6
1
/
2
" (166)
min. 2"
(50)
dia. 2
1
/
8
" (60)
dia. 1
3
/
8
" (35)
14
15
/
(380)
20
1
/
" (520)
*21
1
/
" (*535)
19
3
/
±1
/
" (492
±2
)
*20
1
/
+1
/
" (*515
+2
)
20
11
/
+1
/
" (526
+2
)
*21
1
/
+1
/
" (*541
+2
)
14
3
/
±1
/
(360
±2
)
15
3
/
+1
/
(386
+2
)
**2
3
/
" (70)
1
/
(3)
3
9
/
(90)
8
15
/
(227)
2
13
/
(72)
11"
(280)
3"
(76)
Surface-mount Installation Flush-mount Installation
Control knob installation, surface-mounted installation
Control knob installation, flush-mounted installation
Longitudinal section
Cross-section
153/16"+1/16"
1
5
**2
/
8
39" (1.0 m)
3
1
/ 8 " (35)
min. 2" (50)
1
min. 4
max. 6 3 / 8 " (162)
/ 8 " (3)
" (67)
/ 8 " (105)
15
14
/ 16 "
(380)
20 *21
19 *20
9
3
/ 16 " (90)
3
14
/ 16 "
(360
1
2
/
1
/
3
/ 8 "
1
/
±1
/ 16 "
±2
)
" (520)
16
4 "
" (*535)
±1
/ 16 " (492
+1
16
/
" (*515
dia. 1 3 / 8 " (35)
dia. 2
2
±2)
+2
1
/ 8 " (60)
13
/ 16 "
(72)
)
1
R
15
8
/ 16 "
(227)
11"
(280)
/ 8 " ( 3)
90°
3"
(76)
4
16 "
16 "
2
16
16 "
16 "
16 "
16 "
8 "
16 "
8 "
4 "
16
16
16 " 4 "
16
16
16 "
* with appliance cover or adjustment strip. See separate planning notes on page 77.
** 3 ⁹⁄₁₆"(90) in the area of the wire connection (rear, right).
Installation of the control knob; surface-mount installation
1
min.
3
/16" (5)
5
/ 8 "-1"
(16-26)
3
4
/ 8 "-6
/ 8 "
(105-162)
ø 13/8" (35) ø 13/8" (35)
3
min.
/16" (5)
1
3
/ 8 "x12
(80x310)
3
/ 16 "
1
4
/ 8 "-6
(105-162)
D =1" (26)
D > 1" (26)
3
/ 8 "
* with appliance cover or adjustment strip. See separate planning notes on page 77.
** 3 ¹¹⁄₁₆"(93) in the area of the wire connection (rear, right).
Installation of the control knob; flush-mount installation
1
min.
3
/16" (5)
5
/ 8 "-1"
(16-26)
1
4
/ 4 "-6
/ 2 "
(109-166)
ø 13/8" (35) ø 13/8" (35)
3
min.
/16" (5)
1
3
/ 8 "x12 (80x310)
3
/ 16 "
1
4
/ 4 "-6
(109-166)
D =1" (26)
D > 1" (26)
1
/ 2 "
View from above
(386+2)
3
14
/16"±1/16"
±2
(360
11
/16"+1/16"
20
+2
)
(526
1
/4"+1/16"
*21
(*541
* with appliance cover or adjustment strip (observe front and rear
asymmetrical assembly. See separate notes “assembly with appliance cover/adjustment strip” on page 77).
3
+2
19
/8"±1/16"
)
±2
)
(492
1
/4"+1/16"
*20
+2
)
(*515
R
(R 3)
1
/8"
R 3/16"
)
(R 5
+1
)
Numbers indicated inside parenthesis ( ) = mm
Longitudinal section
1
/8"
+1
)
(3
1
/2"
(13)
Cross-section
1
/8"
(3+1)
11
/16"
(17)
When installing with appliance cover or adjustment strip, pay attention to the deeper cut-out and the front and rear groove width.
15
/16"
14
(380)
3
/16"±1/16"
14
±2
)
(360
3
15
/16"+1/16"
+2
)
(386
1
/2"
20
(520)
3
19
/8"±1/16"
±2
)
(492
2011/16"+1/16"
+2
)
(526
11
/16"
(17)
(3
1
(3+1)
1
/8"
1
/2"
(13)
/8"
fill with
silicone
+1
)
1
-0.5
/8" (3.5
)
fill with
silicone
1
-0.5
/8" (3.5
)
Vario cooktops 51
Loading...