FUTABA T14SG, FX-22 Software Update Manual

Page 1
T14SG / FX-22 SOFTWARE UPDATE MANUAL
[Updating procedure]
1. SD card format
1. You will rst want to format your SD card to the 14SG/ FX-22. If you are using an existing SD card, any data previously saved to it will be deleted during the "format". We suggest you either save this data on your computer or purchase a new card.
T14SG:
SD card slot
① Push to open.
②Slide in the direction of the
arrow on the battery cover.
③ Battery cover will open downward. ④ SD card is inserted in a slot
*It is releasable if a card is pushed once again.
 by direction of a figure.
FX-22:
SD card slot
*Don't mistake the
both sides/ the
direction of
SD card.
① A side cover is opened.
② It inserts until it locks SD card into SD card slot.
*It is releasable if a card is pushed once again.
2. Preparing the software update card.
1. Please unzip the zipped le. The following les will be created.
・T14sgUpdate.exe
・T14sgUpdate.dat
・T14SG_UPDATE.dat
・T14SG_TS.bin
・T14SG_AP.bin
・T14SG_UPLD.bin
2. Insert the 'formatted" SD card into a card reader in your PC.
3. Please run "T14sgUpdate.exe".
3. Please select "YES" and touch “RTN”.
4. The following screen is displayed during formatting.
5. When the format is completed, the following screen is displayed.
4. Select the drive that your card reader is assigned to in your PC.
Update
5. After the Update files are copied to the SD card, the following screens are displayed.
Click the "End" button.
6. Turn off the power switch and remove the SD card from its slot.
- 1 -
Page 2
3. Update software of T14SG/FX-22
PROGRAM UPDATE
START : PUSH MON . 3SEC
PROGRAM UPDATE
PROGRAM UPDATE
COMPLETED
1. Please insert the SD card which includes the update le.
2. Push the HOME/EXIT button.
3. While still holding the HOME/EXIT button, power on the transmitter.
T14SG:
HOME/EXIT
button
FX-22:
HOME/EXIT
button
4. After a few seconds, the following screen is displayed.
U.MENU/MON.
button
U.MENU/MON.
button
5. Push the U.MENU/MON. button for three seconds. The software update will begin.
6. When the update is complete, the following screen is displayed. Turn o󱐯 the power switch.
7. Remove the SD card.
8. Please check the software version at INFO in SYSTEM menu.
UP LOADING
- 2 -
Page 3
T14SG/FX-22 Installing Speech Data Ver.2
INSTALLSOUND
START : PUSH MON . 3SEC
INSTALLSOUND
INSTALLSOUND
INSTALLSOUND
INSTALLSOUND
COMPLETED
Before installing the speech data, you will need to update your T14SG/FX-22 software to Version 2.0 or later. If the software version of T14SG /FX-22 is before Ver.2.0, the speech data can not be installed. Ver.4.x software of T14SG/FX-22 is not able to play the Ver.1 sound data. After updating to Ver.4.x , please install the Ver.2 sound data
to T14SG/FX-22. There are three language versions, English, German, and Japanese, in speech data. It is possible to install only one language. If you install a second language, it will override the rst one that you installed.
[Installing procedure]
1. Making of card for installing speech data
1. Please unzip the zipped le. The following les will be created.
English Version
・T14sgInstallSoundEng.exe
・T14sgUpdate.dat
・T14SG_INSTALL_SOUND.dat
・T14sgSpeechEng1.bin
・T14sgSpeechEng2.bin
・T14sgSpeechEng3.bin
German Version
・T14sgInstallSoundEng.exe
・T14sgUpdate.dat
・T14SG_INSTALL_SOUND.dat
・T14sgSpeechGer1.bin
・T14sgSpeechGer2.bin
・T14sgSpeechGer3.bin
Japanese Version
・T14sgInstallSoundEng.exe
・T14sgUpdate.dat
・T14SG_INSTALL_SOUND.dat
・T14sgSpeechJpn1.bin
・T14sgSpeechJpn2.bin
・T14sgSpeechJpn3.bin
2. Install speech data of T14SG/FX-22
1. Please insert the SD card which includes the installing speech data.
2. Push the HOME/EXIT button.
3. Still holding the HOME/EXIT button, power on the
transmitter.
4. After a few seconds, the following screen is displayed.
5. Press the U.MENU/MON. button for three seconds. The speech data begins to install.
INSTALLING
2. Install the already formatted SD card into your PC's card reader.
3. Please run "T14sgInstallSound***.exe".
4. Select the drive that your card reader is assigned to in your PC. Click "OK".
Update
5. After the Update files are copied to the SD card, the following screens are displayed. Click the "End" button.
6. After about 16 seconds, uploading reaches the right of the progress bar, and then begins again after a pause.
7. The uploading may appear to progress slowly.
INSTALLING
8. The progress bar will again upload. This can take a few minutes.(About. 2 min.)
And, “COMPLETED” is displayed.
Please turn o󱐯 the power.
(Don't turn off the power before COMPLETED is
displayed.)
9. Please detach SD card.
10. Please check the language at TELEM.SET. menu in
LINKAGE menu.
- 3 -
Page 4
1M23N27917
(m/s)
Time (sec)
T14SG/FX-22 Software Update Changes
(Version 4.x)
This software update modies features found on the 14SG/FX-22. If you have questions about these updated directions, please consult your instruction manual or futaba-rc.com for further details. Refer to the original manual where applicable but replace the steps indicated below with these instructions.
1.Sound Data
The version of the sound data is Ver.2. Vario Melody of sink is improved. It is more continuously.
*Ver.4.x software of T14SG/FX-22 is not able to play the Ver.1 sound data. After
updating to Ver.4.x , please install the Ver.2 sound data to T14SG/FX-22.
The version of the sound data which has installed can be checked at TELEM.SET screen.
2.SOUND (Vario Melody Volume)
The Vario Melody volume is added. The Vario Melody Volume is added to adjust by the hardware. (stick, trim, lever, switch)
VARIO MELODY
This is the volume of Vario Melody only.
Setting range : 0 (silent) ~ 30 (maximum)
The hardware for the adjustment is selectable. Setting range : J1,J2,J3,J4,T1,T2,T3,T4,SA,SB,,SC,SD,SE,SF,
SG,SH,LS,LD,RD,RS,(SI,SJ) * ( ) is for FX-22 only. The operation mode of the adjustment hardware is selectable.
ATL+ : When the operation direction is right or down or C.W. , the volume is increased. ATL- : When the operation direction is right or down or C.W. , the volume is decreased. SYM. : The center position is minimum volume. The both end points are maximum
volume.
Vario Melody only
PHONE VOLUME is moved to page 2/2.
The hardware is selectable.
*These settings can be set each sensors.
Climb side value of RANGE
Climb side value of DEADBAND
Page 3/4 is added.
Current variometer value
Sink side value of RANGE
The changing point of climb and sink
Sink side value of DEADBAND
[The relation of Vario Melody settings]
Climb side
(Discontinuous sounds)
Fixed melody Variable melody Variable melodyNot sound Fixed melody
RANGE↑ RANGE↓DEADBAND↑ DEADBAND↓
DELAY
The output vario melody does not change during the delay time. In other words, this is a minimum time of Vario melody output.
Setting range : 0.0,0.5,1.0,1.5 sec
*This parameter is e󱐯ective to all variometers.
OFFSET
Sink side
(Continuous sounds)
Page 4/4 is added .
The minimum time of one Vario Melody output.
Vario Melody Volume
These parameters are same as VARIO MELODY phone volume in page 2/2 of SOUND screen.
The mode is selectable.
3.VARIOMETER (Vario Melody Setting)
Vario Melody Setting is added to the variometer of the Altitude Sensor and GPS sensor.
(SBS-01A, SBS-01G, GPS-F1675, VARIO-F1712, VARIO-F1672)
*At GPS-F1675, VARIO-F1712 and VARIO-F1672, the MODE1-MODE4 setting of
ACT/INH button has been deleted.
RANGE
This is the variable range of the Vario Melody.
↑ (Climb side) : When the variometer is greater than this value, Vario melody is not
Setting range : OFFSET value ~ +50m/s (SBS-01A, SBS-01G)
↓ (Sink side) : When the variometer is less than this value, Vario melody is not
Setting range : -50m/s ~ OFFSET value (SBS-01A, SBS-01G)
OFFSET
This is the changing point of climb and sink. When the variometer is greater than this value, Vario Melody is climb type. When the variometer is less than this value, Vario Melody is sink type.
Setting range : RANGE ↑ setting value ~ RANGE ↓ setting value
DEADBAND
Vario Melody is not output in this range. ↑ (Climb side) : When the variometer is less than this value, Vario melody is not
Setting range : 0m/s ~ +50m/s (SBS-01A, SBS-01G)
↓ (Sink side) : When the variometer is greater than this value, Vario melody is not
Setting range : -50m/s ~ 0m/s (SBS-01A, SBS-01G)
variable.
OFFSET value ~ +50.0m/s (GPS-F1675, VARIO-F1712) OFFSET value ~ +300.00m/s (VARIO-F1672)
variable.
-50.0m/s ~ OFFSET value (GPS-F1675, VARIO-F1712)
-300.00m/s ~ OFFSET value (VARIO-F1672)
output.
0.0m/s ~ +50.0m/s (GPS-F1675, VARIO-F1712)
0.00m/s ~ +300.00m/s (VARIO-F1672)
output.
-50.0m/s ~ 0.0m/s (GPS-F1675, VARIO-F1712)
-300.00m/s ~ 0.00m/s (VARIO-F1672)
[Vario Melody Delay]
Variometer(m/s)
Actually variometer
DELAY time
PHONE VOLUME
CTRL / DIR.
These parameters are same as VARIO MELODY phone volume in page 2/2 of SOUND screen.
These parameters are e󱐯ective to all variometers.
*The parameters in page 4/4 are common to all variometers.
Output Vario Melody
4.TELEM.SET. (Telemetry Alarm Duration and Repeat time)
The repeat time and duration time for the telemetry alarm (buzzer, vibration and speech) can be set.
REPEAT
It is a repeat time of an alarm output. Setting range : INH,1s ~ 240s
DURATION
It is an alarm output time. Setting range : 1s ~ 30s
*DURATION value has to be less than REPEAT value. *DURATION time is extended when the other alarm event occurs.
- 4 -- 3 -
Page 5
[ Duration and Repeat time for Telemetry Alarm ]
Page 2/2 is added.
DURATION is not didplayed when REPEAT is INH.
DURATION value have to be equal or less than REPEAT value.
6.S.BUS SERVO (SBD-1 CH setting)
CH setting of SBD-1 is available.
■ Please connect the SBD-1 and the battery to S.I/F port with 3 ways hub or Y harness.
* The battery is not necessary at FX-22. FX-22 outputs the voltage for SBD-1.
■ Please select S.BUS SERVO menu in SYSTEM menu.
■ Please move to page 3/3.
■ Please operate RECALL button. (RECALL is chosen. ⇒ RTN is pushed. ⇒ RTN is pushed for 1 second.) SBD-1 setting screen is shown.
Sensor A
Alarm
Sensor B
Alarm
Alarm output
(Buzzer, Vibration
, Speech)
DURATION time
ON
OFF
ON
OFF
ON
OFF
REPEAT time
When the new alarm event occurs, DURATION time is extended.
5.SENSOR (Apply to new ESC)
New Robbe's ESC which includes some sensors is applied.
Sensors : Current, Voltage, Current capacity, RPM and Temperature
The slot which can be registered : 8,9,10,11,16,17,18,19,24,25,26,27
Using slots : 5 slots
Please refer the instruction manual of T14SG / FX-22 for each setting.
【Setting range】 ↓ THRESHOLD ~ +150.0A 【Setting range】 -150.0A ~↑ THRESHOLD
1,2,3,
Time
WRITE operation is writing CH settings to SBD-1.
RECALL operation is reading CH settings from SBD-1.
■ Please set CH to each port of SBD-1. (SX1, SX2 and SX3)
* Setting range : CH1 ~ CH12,DG1,DG2
■ Please operate WRITE button. (WRITE is chosen. ⇒ RTN is pushed. ⇒ RTN is pushed for 1 second.)
■ The settings are changed.
■ When the WRITE operation is success, the message "COMPLETED" is shown.
■When the WRITE operation is failure, the message "FAILED" is shown.
(S.BUS CH setting)
CH setting of new Robbe's ESC is available.
■ Please connect the ESC to S.I/F port.
* At FX-22, DO NOT connect the ESC to S/I/F directly.Please use 3 ways hub without
battery line. Or, please use the switch for BEC output and turn o󱐯 the BEC output.
■ Please connect the battry to the ESC.
■ Please select SBUS SERVO menu in SYSTEM menu.
■ Please move to page 3/3.
■ Please operate RECALL button. (RECALL is chosen. ⇒ RTN is pushed. ⇒ RTN is pushed for 1 second.) CH setting screen is shown.
【Setting range】 ↓ THRESHOLD ~ 70.0V 【Setting range】 0.0V ~↑ THRESHOLD
【Setting range】 ↓ THRESHOLD ~ +32,000mAh 【Setting range】 -32,000mAh ~↑ THRESHOLD
【Setting range】 ↓ THRESHOLD ~ 150,000rpm 【Setting range】 0 rpm ~↑ THRESHOLD
【Setting range】 ↓ THRESHOLD ~ +100℃ 【Setting range】 -20℃~↑ THRESHOLD
WRITE operation is writing CH settings to ESC.
RECALL operation is reading CH settings from ESC.
■ Please set CH.
* Setting range : CH1 ~ CH12,DG1,DG2 (ESC does not work in DG1 and DG2.)
■ Please operate WRITE button. (WRITE is chosen. ⇒ RTN is pushed. ⇒ RTN is pushed for 1 second.)
■ The settings are changed.
■ When the WRITE operation is success, the message "COMPLETED" is shown.
■When the WRITE operation is failure, the message "FAILED" is shown.
7.S.BUS SERVO (OLP setting)
When the servo type is OLP mode, the torque and time for OLP can be set. When the load is greater than this setting torque and continues over this setting time, OLP works.
Trq
This is the torque for working OLP.
Setting range : 10% ~ 100% (100% is the maximum torque of the servo which you
are setting.)
TIME
This is the time for working OLP.
Setting range : 0.2,0.5,1,2,3,4,5,6,7,8,9,10,15,20,25,30 sec
When TYPE is set to OLP at page 2/3, OLP trq and time is shown at page 3/3.
*If the setting of OLP torque and time is decreased, it is easier to work OLP.
Then, please be careful not to work OLP at usual operation.
This is the torque for working OLP.
This is the time for working OLP.
- 5 -
Page 6
*S3171SB・S9071SB・S9072SB・S9074SB・S9075SB can not be set to OLP.
J2 J3
These servos apply to NORMAL mode and RETRACTABLE mode only.
8.MODEL TYPE (Addition of MULTIROTOR)
MUTIROTOR type is added to MODEL TYPE.
■ When a model type is MULTIROTOR, an icon for exclusive use is displayed on HOME screen.
■ When a model type is MULTIROTOR, the LINKAGE menu is below. (It is FASSTest 14CH mode. It di󱐯ers at other mode.) Please refer FUNCTION OF LINKAGE MENU in the instruction manual of T14SG/ FX-22 for each function.
*STK ALARM is an addtional function for all model types.
■ The default settings of TRAINER at MULTIROTOR are below. It is easy to set TRAINER, when the student radio is used for camera gimbal control.
*Please do not use REVERSE, END POINT and any other Mixers at student
transmitter.
9.GYRO (Corresponding model type : AIRPLANE / GLIDER
and MULTIROTOR)
The ne tuning hardware setting is added to GYRO for AIRPLANE and GLIDER.
Setting range :
GY type : Setting rate ± 20% (The actual rate has not to be greater than 100%.) NORM type : Setting rate ± 10.0% (The actual rate has not to be greater than 100%.)
This is an actual rate. It is not greater than 100%.
■ When a model type is MULTIROTOR, the MODEL menu is below. Please refer FUNCTION OF MODEL MENU in the instruction manual of T14SG/FX-22 for each function.
*GYRO menu is same as GYRO for the
airplane.
*THR CURVE menu is same as THR
CURVE for the airplane.
■ The default setting of CH and functions are below;
■ The functions which can be set are below.
FUNCTION
Normal Short
AILERON AIL ELEVATOR ELE THROTTLE THR
RUDDER RUD
GYRO GYR GYRO2 GYR2 GYRO3 GYR3
CAM TILT TILT
CAMERA PAN PAN
CAMERA REC REC
MODE MODE AUXILIARY6 AUX6 AUXILIARY5 AUX5 AUXILIARY4 AUX4 AUXILIARY3 AUX3 AUXILIARY2 AUX2 AUXILIARY1 AUX1
*CAM TILT, CAMERA PAN, CAMERA REC and MODE which are added for MULTIROTOR
do not have any special functions. They are same as AUXILIARY functons.
The hardware is selectable.
10.STICK ALARM (Corresponding model type : All Model Types)
An alarm (single beep) can be sounded at the specied stick position.
■ Alarm function ON/OFF can be set by switch.
ON/OFF switch is selectable.
Stick is selectable. (J1, J2, J3, J4) The default setting : Mode 1 → J2  Mode 2 → J3
100%
The stick position for an alarm
Current stick position
J1 J4 0%
0%
11.TIMER (ST1 and ST2 speech function)
Speech function is added to TIMER (ST1 and ST2). When mode is UP timer or DOWN timer, the speech outputs is avalable. It is phone output only.
↑ mode
The voice outputs each minute of the time elapsed from timer start.
Ex. one minute, ・・・ two minutes, ・・・
It outputs voice 20 seconds before reaching to the target time.
Ex. twenty seconds
It is counted down by voice from 10 seconds before reaching to the
target time.
Ex. ten, nine, eight ・・・ three, two, one
↓ mode
The voice outputs each minute of the time remaining up to the alarm time.
Ex. ・・・ ten minutes, ・・・ nine minutes, ・・・
It outputs voice every 10 seconds from 50 seconds before reaching to
the target time.
Ex. fty seconds, ・・・ forty seconds, ・・・
It is counted down by voice from 10 seconds before reaching to the
target time.
Ex. ten, nine, eight ・・・ three, two, one
*The voice alarm of timer is delayed from the actual time. *During logging telemetry data, the voice alarm is delayed more. *The priority of the timer speech is higher than the telemetry speech. Then,
- 6 -
100%
Page 7
the telemetry speech is stopped and the timer speech is outputted, when the telemetry speech is outputted.
*Usually, the priority of the speech of ST1 is higher than ST2. However, the
timer which has started 10 seconds countdown is given the priority. However, the timer which has started 10 seconds countdown is given the priority.
*The telemetry speech can not be outputted during 10 seconds countdown.
12.DG1,DG2 at FASSTest 14CH mode
When R7008SB can be set to Mode C or Mode D, and it is FASSTest 14CH mode, DG1 is output from CH13 (CH5 port) and DG2 is output from CH14 (CH6 port).
*Regarding R7008SB operation mode, please refer the instruction of T14SG/
FX-22 and R7008SB.
*It is FASSTest 14CH mode only that DG1 and DG2 are output from CH13 and
CH14.
R7008SB CH Mode table
Output
connector
8/SB 8 S.BUS 16 S.BUS
Mode A
1 ~ 8CH 1 1 1 9 9 2 2 2 10 10 3 3 3 11 11 4 4 4 12 12 5 5 5 13 13 6 6 6 14 14
7/B 7 7 15 15
Channel
ModeBCHModeC
9 ~ 16CH
ModeD
9 ~ 15CH
DG1 is output from CH13 (CH5 port)
DG2 is output from CH14 (CH6 port)
You can display any items on the telemetry screen up to 16 items at FASSTest 14CH mode. The benefit of expansion of a character will be obtained by choosing the display items 1 and 2.
Ex. 1 item is displayed Ex. 2 items are displayed
Ex. 4-16 items are displayed
TELEMETRY MONITOR set up
① The HOME/EXIT button is pushed from HOME screen and TELEMETRY
MONITOR is called.
② Move the cursor to the "RECEIVER" or "SENSOR" (SBS-XXX etc.) and
touch the RTN button.
13.TELEMETRY DATA LOG (icon)
The card icon indicates that the telemetry data logging function works at HOME screen and TELEM.MONI screen.
Logging data is stop.
Logging data is stop.
Logging data is running.
Logging data is running.
14.TELEM.MONI (The extension of the number of telemetry data which is shown)
The number of telemetry data which is displayed to TELEM.MONI screen is extended. It is 16 items (4 pages) maximum. The page number is memorised automatically. Then, TELEM.MONI screen shows the page which was shown at last time.
*The page is memorised even if the power is turned o󱐯.
It pushes from
HOME screen.
If a cursor is moved to items (Rx- BATT, EXT-VOL, TEMP. etc.) and RTN is touched, the alarm setting screen of the item will be displayed.
③ You will use the "Display" function to choose how many sensors are
shown on your Telemetry monitor.
[ Display position ]
1
1
2
1 3 2 4
④ If you want to show two sensors on your Telemetry screen, select 2 in
"Display". Then move down to the Sensor to select which other item is shown.
When using a sensor that has two or more functions, you will want to scroll to select which will be displayed. (ALTITUDE,VARIO, etc.)
To TELEMETRY MONITOR
⑤ If you want to show three sensors on your Telemetry screen,
select 3 in "Display". Then move down to the Sensor to select which other item is shown.
⑥ To SENSOR " ----------" selection will reduce a display item.
©Copyright 2014. No part of this manual may be reproduced in any form without prior permission. The contents of this manual are subject to change without prior notice. While this manual has
been carefully written, there may be inadvertent errors or omissions. Please contact our service center if you feel that any corrections or clarications should be made.
FUTABA CORPORATION Phone: +81 475 32 6982, Facsimile: +81 475 32 6983
1080 Yabutsuka, Chosei-mura, Chosei-gun, Chiba 299-4395, Japan
©FUTABA CORPORATION 2014, 5 (1)
-7 -
Loading...