This document contains basic product and configuration information that will enable you
to configure your system.
Only these tools will ensure a fast and proper configuration of your PRIMERGY server or your complete
PRIMERGY Rack system.
You can configure your individual PRIMERGY servers in order to meet your specific requirements.
Please follow the lines. If there is a junction, you can choose which way or component
you would like to take.
Go through the configurator by following the lines from the top to the bottom.
Internal Bays 5inch3 (2 free bays) ( 1 (0 free bay) by applying Internal HDD Unit Bay Conversion kit (PG-BC103)
CD-ROMstandard (Max. 24 ATAPI
PCI Slots
RAID Controlle
SAS ControllerSAS x 8ports (Installed as standard) (with RAID1 function
Internal FDD3.5inch (1.44MB/720KB
Network Controller (onboard
InterfacesDisplay (Analog RGB), Serial Port x 2 (D-SUB 9pins), Parallel Port (optional, D-SUB 25pins)
Server Management Software
Remote Service function
Power supplyVoltage
Redundant Fanoptional (hot plug when Power Supply Conversion kit (PGBRSU104) is applied.
Dimensions (mm
WeightTower : 38kg (max.) / Rackmount: 40kg (max.
Environmental ConditionsTemperature10-35°C / Humidity 20-80% (non condensing )
OS Support *5Windows Server® 2003 R2, Standard Edition / Windows Server® 2003 R2, Standard Edition
ttached tool (Standard
1. Available memory capacity will be changed by the type of OS. Please find more details in Notes[Memory OS Compatibility List].
2. Resolution is determined by functions of the display monitor and OS.
3. HDD capacity is calculated according to the formulas 1GB=1000
4. Frequency will be changed by the spec of PCI card and number of cards mounted.
5. Drivers for Linux are not attached. Please download and use drivers of the following URL.
6. CPU Conversion kit: Xeon 5110(1.60GHz/4MB) -> Xeon X5355(2.66GHz/2x4MB) (PGBFU405) is available for upgrading to Quad-Core Intel® Xeon® X5355 2.66GHz.
7. CPU Conversion kit: Xeon 5110(1.60GHz/4MB) -> Xeon E5310(1.60GHz/2x4MB) (PGBFU403) is available for upgrading to Quad-Core Intel® Xeon® E5310 1.60GHz.
8. CPU Conversion kit: Xeon 5110(1.60GHz/4MB) -> Xeon 5160(3GHz/4MB) (PGBFU30T2) is available for upgrading to Dual-Core Intel® Xeon® 5160 3GHz.
9. CPU Conversion kit: Xeon 5110(1.60GHz/4MB) -> Xeon 5130(2GHz/4MB) (PGBFU30S2) is available for upgrading to Dual-Core Intel® Xeon® 5130 2GHz.
10. In case that SAS Controller installed as standard is used for RAID configuration, only 2 HDDs of same capacity and same rpm can be connected.
11. There are some notes for Windows 2003 SP2. Please refer to Notes of Support Matrix.
12. Regarding supported kernel versions of Linux, please refer to the following list.
13. Quad-Core Intel® Xeon® X5355 (2.66GHz) / E5310 (1.60GHz) are not included.
14. Total number of cores of CPU(s) should be four or more for using VM (Virtual Machine) function.
15. ServerStart doesn't support Linux.
. Noise level is 37dB. ( Noise level is 47dB when Power Supply Conversion kit (PGBRSU104) is applied.
*1. By applying Internal HDD Unit Bay Conversion kit (PG-BC103), 5 inch bay x 2 can be converted
to 3.5 inch bay x 2.
When Internal HDD Unit Bay Conversion kit (PG-BC103) is applied, Internal Backup Device
cannot be mounted on 5inch Bay.
*2. By applying Power Supply Conversion kit (PGBRSU104), non-redundant structure (Power Supply x1,
FAN x2) can be converted to redundant structure (Power Supply x2, FAN x6).
*3. Frequency will be changed by the spec of PCI card and number of cards mounted.
When Internal HDD Unit Bay Conversion kit (PGBC103) is applied. ( HDD x 2ports )
Internal Backup Device cannot be mounted
because 5inch Bay x 2 is used by HDDs.
Bay 8
Bay 7
SAS
Hard Disk 3.5inch Bay (hot plug)
Standard Drive Cage ( HDD x 6ports )
Bay 6
SAS
Bay 5
Bay 4
SAS
Bay 3
Bay 2
SAS
Bay 1
*Components installed as standard configuration marked in grey.
Mountable I/O Options
Mount
Priority
SAS Controller
(8ports)
High
SAS RAID Ctrl
Eth. Ctrl 1000-BASE-T Cu
Eth. Ctrl 1x1Gbit PCI
1000-BASE-T
Eth. Ctrl 1000-BASE-SX
Fibre LC
Eth. Ctrl 2x1Gbit PCI-X
1000-BASE-T
RAID Ctrl 2-Channel 128MB
w/ BBU
Low
Fibre Channel Controller
High
Eth. Ctrl 2x1Gbit PCI-E
1000-BASE-T
Eth. Ctrl 1x1Gbit PCI-E
1000-BASE-T
Low
Eth. Ctrl 1x1Gbit PCI-E
1000BASE-SX
Mountable CardsBus
-PCI-X/64bit#
PG-140F /
PGB140F
PG-140G /
PGB140G
PG-1892 /
PGB1892
PG-1853 /
PGB1853
PG-1882PCI-X/64bit
PG-1863PCI-X/64bit-[1][2]-PG-142E3 /
PGB142E3
PG-1281 /
PGB1281
PG-FC202 /
PGBFC202
PG-2861 /
PGB2861
PG-289 /
PGB289
PG-288
PCI-X/64bit
PCI-X/64bit-[1]---
PCI-X/64bit-
PCI/32bit
PCI/64bit-
PCI/64bitPCI Express
(x4)
PCI Express
(x4)
PCI Express
(x1)
PCI Express
(x4)
1012345
PCI-XPCI ExpressPCI
64bit/
100MHz
3.3V
-
-
-
---[1][2]
---[1]
---[1]
--[1][2]
PCI Slot
64bit/
100MHz *1
-
[1]-
[1][2]-
[1][2]
[2][1]--
[2][1]--SCSI Ctrl U160
-
x8
lanex4lane
Full Height
x8 socket
---
---
-
32bit/
33MHz
5.0V
-
-
[3][1][2]--
[3]-
-
[3]2
[3]2
[3]
[3]
-
[2]
-
[2]2
-PCI Express Card
-PCI Express Card
Max No.
of Mount
1
1
2
2
2
2
2
2
2
1
2
3
Remarks
Standard, Internal array1
Internal arraySAS RAID Ctrl
Internal array
* No AFT/ALB Support
External array
Internal/External SCSI
Controller
PCI Express Card
PCI Express Card
* [n] : Installation Priority
* # : standard
* - : cannot be installed
*1.Frequency will be changed by the spec of PCI card and number of cards mounted.
Page 6
Slot
PRIMERGY TX200 S3
Connection Table
Form factor conversion
(Tower to Rackmount)
CPU
Rack Conversion kit for TX200 S3
(Tower to Rackmount (4U))
PG-R1CK20
PGBR1CK20 (for CTO)
CPU
Max: 2 CPUProcessor Xeon X5355 2.66GHz/2x4MB
PG-FG405
PGBFG405 (for CTO)
*. This option is available when CPU Conversion Kit:
Xeon 5110(1.60GHz/4MB) -> Xeon X5355(2.66GHz/2x4MB) (PGBFU405) is applied.
Processor Xeon E5310 1.60GHz/2x4MB
PG-FG403
PGBFG403 (for CTO)
*. This option is available when CPU Conversion Kit:
Xeon 5110(1.60GHz/4MB) -> Xeon E5310(1.60GHz/2x4MB) (PGBFU403) is applied.
Processor Xeon 5160 3GHz/4MB
PG-FG30T
PGBFG30T (for CTO)
*. This option is available when CPU Conversion Kit:
Xeon 5110(1.60GHz/4MB) -> Xeon 5160(3GHz/4MB) (PGBFU30T2) is applied.
Processor Xeon 5130 2GHz/4MB
PG-FG30S
PGBFG30S (for CTO)
*. This option is available when CPU Conversion Kit:
Xeon 5110(1.60GHz/4MB) -> Xeon 5130(2GHz/4MB) (PGBFU30S2) is applied.
Processor Xeon 5110 1.60GHz/4MB
PG-FG30R
PGBFG30R (for CTO)
*. This option is available when the processor of the base unit
is Processor Xeon 5110(1.60GHz/4MB).
*CPU Conversion Kit (available only as a Configure To Order (CTO) option; no separate shipment is possible)
TypeProduct ID
CPU Conversion Kit:
Xeon 5110(1.60GHz/4MB)Convert the CPU installed as standard in the base unit to the other.
-> Xeon X5355(2.66GHz/2x4MB)(Note: This option can be ordered only as coupled with the base unit.
(for CTO)A separate shipment is not possible.)
CPU Conversion Kit:Dual-Core Intel® Xeon® 5110(1.60GHz/4MB) -> Quad-Core Intel® Xeon® E5310(1.60GHz/2x4MB)
Xeon 5110(1.60GHz/4MB)Convert the CPU installed as standard in the base unit to the other.
-> Xeon E5310(1.60GHz/2x4MB)(Note: This option can be ordered only as coupled with the base unit.
(for CTO)A separate shipment is not possible.)
CPU Conversion Kit:Dual-Core Intel® Xeon® 5110(1.60GHz/4MB) -> Dual-Core Intel® Xeon 5160(3GHz/4MB)
Xeon 5110(1.60GHz/4MB)Convert the CPU installed as standard in the base unit to the other.
-> Xeon 5160(3GHz/4MB)(Note: This option can be ordered only as coupled with the base unit.
(for CTO)A separate shipment is not possible.)
CPU Conversion Kit:Dual-Core Intel® Xeon® 5110(1.60GHz/4MB) -> Dual-Core Intel® Xeon® Xeon 5130(2GHz/4MB)
Xeon 5110(1.60GHz/4MB)Convert the CPU installed as standard in the base unit to the other.
-> Xeon 5130(2GHz/4MB)(Note: This option can be ordered only as coupled with the base unit.
(for CTO)A separate shipment is not possible.)
1. Memory is installed by pairs of FB-DIMMs of the same capacity. Installation of one FB-DIMM or a mixed -capacity pair is impossible.
2. The memory capacities of the slots should be in ascending order in the following sequence:
DIMM slots 1A,1B (Bank 1) -> DIMM slots 2A,2B (Bank 2) -> DIMM slots 3A,3B (Bank 3)
(Available Memory Area)
Windows® 2000 Server (SP4)
Windows® 2000 Advanced
Server (SP4)
Others
Max: 16GBMemory Module-1GB (512MB FB-DIMM x 2)
PG-RM1CE
Standard Memory Module: 1GB (512MB FB-DIMM x 2)
Memory Module-2GB (1GB FB-DIMM x 2)
PG-RM2CE
Memory Module-4GB (2GB FB-DIMM x 2)
PG-RM4CE
Memory Module-8GB (4GB FB-DIMM x 2)
PG-RM8CE
Memory Module Conversion kit (for CTO)
Memory Module Conversion kit-2GB (1GB FB-DIMM x 2)
1GB -> 2GBPGBRU2CE (for CTO)
Memory Module Conversion kit-4GB (2GB FB-DIMM x 2)
Mounted Memory
~3.0GB
4.0GB
~7.0GB
8.0GB
~16.0GB
1GB -> 4GBPGBRU4CE (for CTO)
Available Memory Area
Same as the size of mounted memory
Size of Mounted Memory minus "1.0GB"
Same as the size of mounted memory
Size of Mounted Memory minus "1.0GB"
Same as the size of mounted memory
*. Spare Memory function
In the case of using Spare Memory function, same DIMMs of two or more banks are required to be installed.
Available memory capacity is "installed memory" minus "capacity of Spare Memory ( 1 Bank )".
Page 8
PRIMERGY TX200 S3
Connecting Internal HDD and Internal Backup Devices
If you would like to order internal HDDs and internal backup devices, please order optional cards/cables according to the following table.
Type of HDD connection
Connection
Standard Drive Cage
(6bays)
SAS /
RAID
RAID
(''1) USB Backup Devices: PG-DT504
(''2) SCSI Wide Backup Devices: PG-LT302/PG-LT201/PGBLT201C1/PG-LT102
(''3) If you order internal backup devices by CTO, SCSI cable is attached with backup devices.
Internal HDD
PCI Bus
When Internal HDD Unit Bay
Conversion kit (PG-BC103) is
applied. (+2bays)
Standard Drive Cage
(6bays)
When Internal HDD Unit Bay
Conversion kit (PG-BC103) is
applied. (+2bays)
SAS / RAID Configuration
Drive Cage
SAS Controller (standard)
*. In case that SAS Controller installed as standard
is used for RAID configuration, only 2 HDDs of same
capacity and same rpm can be connected.
SAS Controller (standard)
*. Only SAS Configuration is supported.
SAS RAID Ctrl (PG-140F/PG-140G)
( SAS Controller (standard) )
SAS RAID Ctrl (PG-140F/PG-140G)
( SAS Controller (standard) )
SAS ControllerPG-HDB75A
( installed as standard )PGBHDB75A (for CTO)
*. In case that SAS Controller installed
as standard is used for RAID configuration,HDD SAS 15k 147GB hot plug 3.5inch
only 2 HDDs of same capacity and sameInternal HDD Unit BayPG-HDB45A
rpm can be connected.Conversion kitPGBHDB45A (for CTO)
*. RAID1 configuration can be set.PG-BC103
*. Hot spare disk cannot be set.
RAID Configuration
*. When Internal HDD Unit Bay Conversion kit
SAS RAID Ctrl (PG-BC103) is applied, up to 8 Internal HDDs
(without BBU) can be mounted but internal backup devices
PG-140F cannot be mounted on 5inch Bays.
PGB140F (for CTO)
*. RAID 0/1/5/1+0 configuration can be set.
To set RAID configuration, two or more HDDs
which are same capacity and same rpm
should be connected to SAS Controller
installed as standard.
SAS RAID Ctrl
(with BBU)
PG-140G
PGB140G (for CTO)
HDD SAS 15k 300GB hot plug 3.5inch
PG-HDB35A
PGBHDB35A (for CTO)
*. RAID 0/1/5/1+0 configuration can be set.
To set RAID configuration, two or more HDDs
which are same capacity and same rpm
should be connected to SAS Controller
installed as standard.
Page 9
PRIMERGY TX200 S3
Internal backup device
PCI Bus
SCSI Ctrl U160 by CTO and can be connected to multiple backup devices.w/ SCSI Cable
PG-1281*. One internal backup device can be ordered by CTO.PGBLT302C (for CTO)
PGB1281 (for CTO)*. One internal backup device can
*. In case that internal backup device is ordered by CTO,
SCSI Ctrl U160 (PGB1281) should be ordered too.
*. One internal backup device can be ordered by CTO.
*. When internal HDD Unit Bay Coversion kit (PG-BC103) is applied,w/ SCSI Cable
internal backup devices can not be mounted on 5 inch bays.PGBLT102C (for CTO)
Internal backup device (USB)
USB Interface
(internal)
*. One internal backup device(USB) can be ordered by CTO. be mounted.
*. When internal HDD Unit Bay Coversion kit (PG-BC103) is applied,
internal backup devices can not be mounted on 5 inch bays.
( In case that internal backup device is ordered by CTO. )
*. One SCSI cable is attached with backup device orderedTape Drv LTO3 Ultrium3/Ultrium2 400GB
( In case that internal backup device is ordered without CTO. )
SCSI Cable 1.7mPGBLT201C1 (for CTO)
PG-CBLS025*. One internal backup device can
*. One SCSI cable can be connected to multiple backup devices. be ordered by CTO.