Fujitsu TX150 S4 User Manual

Page 1
PRIMERGY TX150 S4
System configurator and order-information guide
December 2005
Contents
Instructions Configuration diagram Configurator
0 System software I Basic unit II Processor III Memory IV Graphics V Accessible drives VI Hard disk drives VII SCSI Controller VIII Disk array IX Communication/Network X System management options XI Miscellaneous XII Country specific options
Change report
PRIMERGY Server
Page 2
System configurator and order-information guide
PRIMERGY TX150 S4 Status 25.11.2005
Instructions
This document contains basic product and configuration information that will enable you to configure your system via
PC-/ System-Architect.
Only these tools will ensure a fast and proper configuration of your PRIMERGY server or your complete
PRIMERGY Rack system.
You can configure your individual PRIMERGY server in order to adjust your specific requirements.
The System configurator is divided into several chapters that are identical to the current price list and PC-/ System-Architect
Please follow the lines. If there is a junction, you can choose which way or component you would like to take. Go through
the configurator by following the lines from the top to the bottom.
Section
In one chapter you can only select as many components (here 4x) as the arrow indicates.
Please note that there are information symbols which indicate necessary information.
Further information in the internet see:
http://www.primergy.com
(internet)
http://extranet.fujitsu-siemens.com/primergy
(extranet)
Prices and availability see price list and PC-/ System-Architect
Subject to change and errors excepted
X times
III
S26361-XXX-XXX S26361-XXX-XXX
Memory XXX MB Memory XXX MB
max. X times per system max. X times per system
Memory, example
There are X memory slots which can be equipped with XXX MB. It is permissible to make up to X passes through the memory upgrade options.
4x
Fujitsu Siemens Computers
Enterprise Products - PRIMERGY Server
2 of 18
Page 3
System configurator and order-information guide
PRIMERGY TX150 S4 Status 25.11.2005
Configuration diagram PRIMERGY TX150 S4
3 x 5.25"
Modul 3
Accessible drives ( V )
Modul 4
Memory ( III )
PCIe x 1
PCIe x 4 (x8 Slot)
(Slot for Zero-Channel Controller)
Key:
System unit ( I )
SIDE VIEW FRONT VIEW
Standard Power Supply
or PS (I) 5.25" x 1.6"
1. PSU 2. PSU
Redundant power supply option 5.25" x 1.6"
5.25" x 1.6" CD / DVD drive
Modul 1
Pentium 4
Bank 1Bank 2
Modul 2
Processor ( II )
Extension slots
SCSI Controller ( VII )
1 PCI-Bus
Disk array ( VIII ) Hard disk drives ( VI ) Communication/Network ( IX )
6.
PCI short (5V) 32-Bit / 33MHz
5.
PCI short (5V) 32-Bit / 33MHz
4.2.1. 7.
PCI-X 66 long (3,3V)
3.
PCI-X 66 long (3,3V)
PCI long (5V) 32-Bit / 33MHz
SCSI 1"
SCSI 1"
SCSI 1"
SCSI 1"
Included in basic unit Option
Fujitsu Siemens Computers
Enterprise Products - PRIMERGY Server
3 of 18
Page 4
System configurator and order-information guide
Start PRIMERGY TX150 S4
PRIMERGY TX150 S4 Status 25.11.2005
http://extranet.fujitsu-siemens.com/primecluster
http://vil.mch.fsc.net/vil/pc/vil/primergy/overview/prince/index_en.htm
for internal users:
http://vil.mch.fsc.net/vil/oec/special/primergy/index_en.htm
for partners:
http://vilpart.fujitsu-siemens.de/vil/oec/special/primergy/index_en.htm
SW Configurator IA32
with OEM-Software without OEM-Software
for PRIMERGY Server for PRIMERGY Server
VMware-Software software is not allowed,
- VCMS VirtualCenter Management Server apart from few VMware
- GSX Server and GSX Virtual Infrastructure Node add-ons
- P2V Assistant Enterprise Edition
For all SW products please refer to the corresponding software configurator accessible via the Extranet under Configuration & Tools, -All configurations, -Software, URL see below.
Microsoft - Software: **) OES/NetWare-Software ***) PRIMECLUSTER *)
- Small Business Server 2003 - NetWare - Clustering
- Windows Server 2003, - Load Balancing Web Edition (only English)
Standard Edition Enterprise Edition
- Additional loose Linux - Software: **) Client-Access-Licenses (CALs) - SUSE Linux Enterprise Server (not for Web Edition) - SUSE Professional Linux
- Red Hat Enterprise Linux
SCO - Software: **)
- SCO OpenServer
- SCO UnixWare
CITRIX-Software für Windows: W-MF
- Presentation Server LoadBalancing Additional User Licences
Later use of OEM operating system
Manageability Software: V**) Details eg. version numbers are published
- RemoteView Software in the separate SW-Configurator
- RemoteView Service Board
- RemoteDeploy
- Terminal Server Deploy
- vPMS 2005std
- Altiris Server Deployment
Backup-Software / Application-Software: U
- ARCserve
- openSM2
Various Software Configurators and release lists (OS-Matrix / System Management / Security) can be optain under the following adresses:
Continue with PRIMERGY HW configurator
*) Pay attention to the PRIMECLUSTER release and ordering information in the Extranet under
**) Pay attention to the release and ordering information in PRINCE -> Operating System
***) Supply over distribution or procurement from FSC VP BC Software
Enterprise Products - PRIMERGY Server
Fujitsu Siemens Computers
4 of 18
Page 5
System configurator and order-information guide
Start PRIMERGY TX150 S4
PRIMERGY TX150 S4 Status 25.11.2005
- SuSE Linux Enterprise Server
http://www.primecluster.com
for internal users:
http://vil.mch.fsc.net/vil/oec/special/primergy/index_en.htm
for partners:
http://vilpart.fujitsu-siemens.de/vil/oec/special/primergy/index_en.htm
SW Configurator EM64T
with OEM-Software without OEM-Software
for PRIMERGY Server for PRIMERGY Server
Later use of OEM operating system software is not allowed, apart from few VMware add-ons
For all SW products please refer to the corresponding software configurator accessible via the Extranet under Configuration & Tools, -All configurations, -Software, URL see below.
only - Windows Server 2003, only EM64T x64 Standard Edition EM64T - Red Hat Enterprise Linux
Microsoft - Software: W Linux - Software: L *) **)
x64 Enterprise Edition
- Additional loose Client-Access-Lizenzen (CALs)
Details eg. version numbers are published in the separate SW-Configurator
Manageability Software: V**)
- RemoteView Software
- RemoteView Service Board *) Pay attention to release information on datasheet under
- RemoteView Diagnosis
**) Pay attention to release and order information in PRINCE -> Operating System
http://vil.mch.fsc.net/vil/pc/vil/primergy/overview/prince/index_en.htm
***) Supply over distribution or procurement from FSC VP BC Software
Various Software Configurators and release lists (OS-Matrix / System Management / Security) can be optain under the following adresses:
Continue with PRIMERGY HW configurator
Enterprise Products - PRIMERGY Server
Fujitsu Siemens Computers
5 of 18
Page 6
System configurator and order-information guide
Start PRIMERGY TX150 S4
PRIMERGY TX150 S4 Status 25.11.2005
Cables included in basic unit
Connections
Cable
PRIMERGY TX150 S4
1.
IDE CD/DVD
¡¡¡
Key:¥68pins
2.
Backplane for 1x4
¥
68 or 50pins
SCSI hard disks
¥¥¥¥¡
IDE
incl. terminator
terminator
Section
I
Basic unit
System unit consisting of: * Housing including standard power supply (no redundancy) * Sliding screen with lock (only for floorstand version)
Systemboard with: * 7 PCI slots:
1x PCIe x 1 1x PCIe x 4 (x8 Slot) 1x PCI-X 66 long (3,3V) 1x PCI-X 66 (3,3V) ZCR Slot
1x long / 2x short 32Bit / 33MHz (5V) * 4 memory slots for up to 8GB (PC4200) registered DDR II RAM (ECC), max. 2GB modul per slot * 1 drive bay 3.5" occupied by 1 floppy disk 1.44MB 1" height (optional) * 3 Einbauplätze 5,25" für bedienbare Laufwerke * 4 bays 1" for hot plug SCSI HD) * ATI Range XL Graphic controller 8MB * Intel Broadcom (5721) 10/100/1000 Mb/s on-board * 1 x Fast-IDE (ATA) Controller on-board (for 1x 2 devices) * 1-channel Ultra 320 SCSI Controller LSI 1020A on-board
with HW RAID IME (IME = Integrated Mirroring Enhanced)
Options: * Hot plug PS or a second redundant hot plug PS version can be configured by ordering the appropriate upgrade option * LSI Zero Channel RAID option, simultaneous use of HD and Tape Drive possible
Cables:
1. IDE cable for CD/DVD
2. With SCSI variant wide LVD SCSI cable for connection of the HD backplane and two accessible drives
PS/2 mouse (only for floorstand version)
ServerStart packet incl. ServerBooks CD, ServerSupport CD and ServerView External Interfaces:
2x RS-232-C (serial, 9 pins) 1x Centronics (parallel, 25 pins, EPP/ECP compatible) 1x keyboard (PS/2) 1x mouse (PS/2) 1x VGA (15 pins) 1x USB 2.0 on front and 2x USB 2.0 on rearside 1x LAN RJ45
A
Fujitsu Siemens Computers
Enterprise Products - PRIMERGY Server
6 of 18
Page 7
System configurator and order-information guide
A
PRIMERGY TX150 S4 Status 25.11.2005
Floorstand version SCSI basic unit 19" Rack version SCSI basic unit (5 U)
Pentium 4 processor, memory Pentium 4 processor, memory
PD 820 2.8GHz/800MHz/2x1MB 512MB S26361-K999-V136 PD 820 2.8GHz/800MHz/2x1MB 512MB S26361-K999-V336 PD 820 2.8GHz/800MHz/2x1MB 1GB S26361-K999-V146 PD 820 2.8GHz/800MHz/2x1MB 1GB S26361-K999-V346 PD 820 2.8GHz/800MHz/2x1MB 2GB S26361-K999-V156 PD 820 2.8GHz/800MHz/2x1MB 2GB S26361-K999-V356
S26113-F483-E1 floorstand S26113-F483-E1
hot plug power supply upgrade option versions hot plug power supply upgrade option With this option the basic units contains A second, redundant With this option the basic units contains 1 hot plug power supply, 1 power power supply requires 1 hot plug power supply, 1 power backplane and 1 dummy cover an additional power backplane and 1 dummy cover replacing the standard power supply cord replacing the standard power supply (no redundancy !) (section XII) (no redundancy !) max. 1x per system max. 1x per system
S26113-F483-E11 S26113-F483-E11
2nd power supply module (PSU) 2nd power supply module (PSU) for redundancy for redundancy occupies one bay for occupies one bay for hot plug power supply hot plug power supply max. 1x per system max. 1x per system
B1 B2
For later conversion of basic units with standard power supply to hot plug power supply, the following kit is available:
1.) hot plug PS upgrade kit, incl. 2 PS module: S26113-F483-L1 Conversion standard into hot plug PS
2.) Supplementary power supply module S26113-F483-L11 for redundancy or repair
Fujitsu Siemens Computers
Enterprise Products - PRIMERGY Server
7 of 18
Page 8
System configurator and order-information guide
B1 B2
PRIMERGY TX150 S4 Status 25.11.2005
PRIMERGY Floorstand PRIMERGY Rack
PRIMECENTER- Rack
SNP:SY-F1647E301-P "rack-mounting ex factory" Installation ex works for one This service is to be ordered once server or subsystem per installable server/storage Hereby the rack will be delivered subsystem, in order to get the completely pre-mounted and server/storage subsystem all wired connections are tested mounted into the PRIMERGY racks.
With racks 12U, 24U, 38U: In case of the 46 U PRIMERGY rack, Systems and components this service has to be ordered, will be delivered installed in the rack to get the mounting kits and the With racks 46U: cables installed. Systems and components will be delivered separately To be ordered only together with a PRIMERGY­PRIMECENTER rack e.g.:SNP:SY-K614V10x-P S26361-K826-V10x
refer configurator PC-rack
max. 1x per System
For later conversion of TX150 base unit floorstand into base unit rack the following kit is availible
1.) Conversion TX150S4 base unit floorstand into base unit rack S26361-F2618-L240 rack mount kit has to be ordered separately
For (later) mounting in racks the following kits are available:
1.) PRIMERGY Classic-rack 42/23U adapter kit: S26361-F1331-L300 incl. cable carrier
2.) PRIMERGY DC- / PC- rack mounting kit: S26361-F2734-L32 incl. DC- PC- bracket, cable managment
3.) PRIMERGY mounting kit for server racks S26361-F2734-L32 conforming to EIA standards EIA-310-D for 19" racks.
C
Fujitsu Siemens Computers
Enterprise Products - PRIMERGY Server
8 of 18
Page 9
System configurator and order-information guide
C
PRIMERGY TX150 S4 Status 25.11.2005
Section
Section
Section
II
III
S26361-F3000-E513 S26361-F3000-E514 S26361-F3000-E515
Main memory 512MB Main memory 1GB Main memory 2GB
3x
DDR2 533/PC2-4200 ub ECC DDR2 533/PC2-4200 ub ECC DDR2 533/PC2-4200 ub ECC consisting of one module consisting of one module consisting of one module occupies one bank occupies one bank occupies one bank max. 3x per system max. 3x per system max. 3x per system
IV
Processor
Memory
There are 2 memory banks with 2 DIMM slots each.
Single channel memory configuration allow maximum flexibility:
Additional memory can be configured as single memory modules.
Dual channel memory configurations for maximum performance:
For optimum performance memory has to be configured in pairs of memory modules with identical size.
Graphics
ATI Rage XL (8MB)
D
Fujitsu Siemens Computers
Enterprise Products - PRIMERGY Server
9 of 18
Page 10
System configurator and order-information guide
D
PRIMERGY TX150 S4 Status 25.11.2005
Section
SNP:SY-F2234E1-A S26361-F3148-E1
DVD-ROM ATAPI DVD-RW 16x super multi drive
2x
incl. description (Ger/US) only W2K, W3K and Linux
1.6 x 5.25", anthracite bezel 1.6 x 5.25", anthracite bezel max. 2x per system max. 1x per system
V
S26361-F2575-E1
Floppy disk drive 1" Connector: 26pin incl. description (Ger/US) 1" * 3.5", anthracite bezel max. 1x per system
Accessible drives
all formats, DUAL/DL, DVD-RAM
There are 3x 5.25" bays for accessible drives:
- 1x 5.25" bay is occupied by a DVD-/CD- respectively a CD-RW drive
- 2 x 5.25" bays remaining, can be occupied by 2x accessible drives
Setup TX150 S4 by ServerStart is supported with following configurations:
no DVD, no CD:
remote installation only ( PXE service & DHCP server required)
built in CD/DVD:
UNC Network share reachable or USB Floppy or MemoryBird connected
One of the following USB devices must be used for integrating the drivers during installation process if no automized (e.g. Serverstart / Altiris / RIS / ADS / …) installation is done:
1) FDD USB (external): external USB FDD (USB cable included)
2) USB Memorybird: Memorybird 256 MB S26391-F6046-L256 Memorybird 1GB
S26391-F264-L226
S26391-F6046-L24
S26361-F3157-E3
Tape drive LTO2HH Ultrium 200GB, 24MB/s, U160 SCSI Connector: HD68 without cable incl. description (Ger/US) data and cleaning cartridge
1.6 * 5.25", anthracite bezel max. 1x per system
S26361-F2849-E3
Tape drive VXA-2 80GB, 6MB/s, U2W SCSI Connector: HD68
2x
without cable incl. description (Ger/US) data and cleaning catridge
1.6 x 5.25", anthracite bezel max. 2x per system
S26361-F2848-E3
Tape drive DDS Gen5 S26361-F2848-E31 (only for OBDR) DDS-G5 for One buttom dis. recov. 36GB, 3MB/s, U2W SCSI Connector: HD68 without cable incl. description (Ger/US) data and cleaning catridge
1.6 x 5.25", anthracite bezel max. 2x per system
E
Fujitsu Siemens Computers
Enterprise Products - PRIMERGY Server
10 of 18
Page 11
System configurator and order-information guide
E
PRIMERGY TX150 S4 Status 25.11.2005
S26361-F2814-E6 Backup drive and hard disk should run on separate channels 68-Pin Kit for accessible drives Cable with Terminator To connect acc. drives to separate SCSI controller max. 1x per system
If internal HDD's are connected at the RAID controller (not IME/ZCR), then for internal accessible drives the cable S26361-F2814-E6 must be ordered additionally!
Section
VI
S26361-F3121-E173 S26361-F3121-E114 S26361-F3121-E130
Hard disk 73GB in 1" carrier Hard disk 146GB in 1" carrier Hard disk 300GB in 1" carrier 10000rpm,<5,5ms, 8MB Cache 10000rpm,<5,5ms, 8MB Cache 10000rpm,<5,5ms, 8MB Cache
Ultra 320 SCSI (320MB/s) Ultra 320 SCSI (320MB/s) Ultra 320 SCSI (320MB/s)
Interface: Wide SCA (80-pins) Interface: Wide SCA (80-pins) Interface: Wide SCA (80-pins) hot plug/hot replace tray hot plug/hot replace tray hot plug/hot replace tray occupies 1" bay occupies 1" bay occupies 1" bay SCSI/RAID controller necessary SCSI/RAID controller necessary SCSI/RAID controller necessary
Hard Disk Drives
4x max. 4x per system max. 4x per system max. 4x per system
S26361-F3121-E573 S26361-F3121-E514
Hard disk 73GB in 1" carrier Hard disk 146GB in 1" carrier
15.000rpm,<4ms, 8MB Cache 15.000rpm,<4ms, 8MB Cache
Ultra 320 SCSI (320MB/s) Ultra 320 SCSI (320MB/s)
Interface: Wide SCA (80-pins) Interface: Wide SCA (80-pins) hot plug/hot replace tray hot plug/hot replace tray occupies 1" bay occupies 1" bay SCSI/ RAID controller necessary SCSI/ RAID controller necessary max. 4x per system max. 4x per system
F
Fujitsu Siemens Computers
Enterprise Products - PRIMERGY Server
11 of 18
Page 12
System configurator and order-information guide
F
PRIMERGY TX150 S4 Status 25.11.2005
LSI Integrated Mirroring Enhanced (IME) is a RAID 1 implementation (no RAID 0 support). It can be operated also with an odd
Section
VII
SCSI-Controller
All internal cables and adapters are included within the basic units and components respectively
Cabeling priorities:
internal HDs are cabled according to following priorities. (Prio 1 - 3 ):
1.) For a configuration without any Disk Array Controller and without zero channel RAID
the onboard U320 Controller is connected to the internal HDs.
2.) For a configuration with a 2-channel Disk Array controller (without zero-channel RAID)
One channel will be connected with the internal hard disks. The second channel is externally available.
internal backup devices are cabled according to following priorities. (Prio 1 - 2 ):
1) For a configuration without additional SCSI controller
the onboard U320 controller is connected to internal backup devices
2) For a configuration with Adaptec SCSI Card 29160 S26361-F2399-E2 (without SCSI 160 controller S26361-F2644-E11)
this controller is connected to internal backup devices
A. on-board SCSI-controller for accessible drives and SCSI-HDs
1-channel Ultra 320 SCSI on-board controller; included as standard.
Example for IME with 3 data devices:
number of hard disks (max. one RAID 1 Set). There are, depending on system, up to 6 hard disks, including a hot spare disk, possible. Supportet are only the operating systems Windows2000/2003 as well as SuSE and RedHat Linux.
All internal cables and adapters for the basic unit and for components are included.
1x per TX150S4
T26139-Y3849-L1
External on-board SCSI Interface connection of the on-board SCSI controller Cable and external and the 29160. connector interface (HD68) Cable sold separately not mounted in factory. occupies one connection panel Use this cable only if on-board controller is not max. 1x per system for ext. used otherwise (eg. S26361-F2814-E6)
G
Only SX10 Backup is released for the external
Fujitsu Siemens Computers
Enterprise Products - PRIMERGY Server
12 of 18
Page 13
System configurator and order-information guide
G
PRIMERGY TX150 S4 Status 25.11.2005
B. SCSI controller for internal backup drives
S26361-F2399-E2
SCSI 160 Controller Adaptec SCSI Card 29160 1 channel: LVD + Fast/ Ultra (decoupl.) LVD connect. for HD, without cable Fast/Ultra connect. for acc. drives 64/66 PCI, min 180 mm int: Fast 50-pin or Ultra HD68 + LVD HD68; ext: HD68(LVD) SW: max. 1x per system
S26361-F2814-E6
68-Pin Kit for accessible drives Cable with Terminator To connect acc. drives to separate SCSI controller max. 1x per system
C. SCSI controller for external drives and peripheral devices
Section
max. 4x
S26361-F2399-E1
SCSI U160 controller Adaptec SCSI Card 29160 1 channel: LVD + Fast/ Ultra (decoupl.) LVD connect. for HD, without cable Fast/Ultra connect. for acc. drives 64/66 PCI, min 180 mm int: Fast 50 pol oder Ultra HD68 + LVD HD68; ext: HD68(LVD) SW: max. 1x per system
VIII
D. LSI - Controller
1-channel Ultra 320 SCSI on-board controller with LSI Integrated Mirroring (IME) Standard SCSI-cabling of a PRIMERGY TX150 S4 basic unit with on-board controller
Ultra 320 SCSI controller is connected to the internal hard disks and internal backup devices, if no additional HD/backup device controllers are configured. 1x per PRIMERGY TX150 S4
S26361-F3085-E128
0-channel RAID controller LSI 320-0x 128MB SDRAM ECC Cache BBU optional in combination with on-board U320 SCSI controller blue marked bay. without cable 64Bit/133MHz PCI-X controller
3.3V power supply & signaling the IME function is no longer max. 1x per system
Disk Array
D. zero-channel RAID controller (320-0x) for internal Disk Array and additional RAID controllers for internal / external Disk Array
Zero channel RAID controller LSI must be installed in the
With zero channel RAID controller
available.
Only SX10 Backup is for external connection at the SCSI controller.
S26361-F3085-E10
Cache Battery Backup Unit
to be continued on next page
max. 1x pro Controller
H
Fujitsu Siemens Computers
Enterprise Products - PRIMERGY Server
13 of 18
Page 14
System configurator and order-information guide
H
PRIMERGY TX150 S4 Status 25.11.2005
continued on previous E. 2-Kanal Ultra 320 SCSI Controller für Disk Array
page
1x
S26361-F3090-E256
2-channel RAID Controller U320 LSI 320-2x 256MB SDRAM ECC Cache default with TBBU plug: internal 2x HD68; external: 2x VHDCI without cable 64/133 PCI-X controller, 180mm
3.3V and 5V tolerant signaling max. 1x per system
The fitting connection cables can be found in the configurator of the external storage system and / or rack.
S26361-F2814-E6 Backup drive and HDD should run on separate channels. 68-Pin Kit for accessible drives Cable with Terminator To connect acc. drives to separate SCSI controller max. 1x per system
If internal HDD's are connected at the RAID controller (not IME/ZCR), then for internal accessible drives the cable S26361-F2814-E6 must be ordered additionally!
I
Fujitsu Siemens Computers
Enterprise Products - PRIMERGY Server
14 of 18
Page 15
System configurator and order-information guide
I
PRIMERGY TX150 S4 Status 25.11.2005
4x
Section
IX
Gigabit Ethernet Contr. on-board The Intel LAN controllers 1000MT can be used Broadcom with the on-board controller in Teaming Mode ext: for RJ 45-connector SW: AFT, VLAN, Fast Channel
S26361-F3053-E1 S26361-F3142-E1
Gigabit Ethernet Contr. 1000TX Gigabit Ethernet Contr. 1000TX Eth. Ctrl 1x1Gbit PCI-X Pro/1000MT Cu Eth. Ctrl 1x1Gbit PCI32 PRO/1000GT Cu Intel PRO/1000 MT Server Adapter Intel Pro/1000 GT Adapter Adapter Teaming Support PCI-X (PCI64/133), min 165 mm ext: for RJ45-plug, Cat 5 ext: for RJ45-plug, Cat 5 connection with Cat 5 cabling SW: VLAN, Fast & Gbit Etherchannel SW: VLAN, Fast & Gbit Etherchannel max. 4x per system
S26361-F3011-E1
Gigabit Ethernet Contr dual 1000TX Intel Pro/1000MT dual Server Adapter Adapter Teaming Support PCI-X (PCI64/133), min 163 mm ext: for RJ45-plug, Cat 5 connection with Cat 5 cabling SW: VLAN, Fast Etherchannel max. 2x per system
Communication / Network
PCI 32 (33/66MHz),
connection with Cat 5 cabling
max. 4x per system
S26361-F1809-E2
ISDN SO Controller PCI Eicon Diva Server BRI-2M 2.0 Incl. SO-connector occu. short PCI slot min. 170 mm SO-Interface max. 2x per system
J
Fujitsu Siemens Computers
Enterprise Products - PRIMERGY Server
15 of 18
Page 16
System configurator and order-information guide
J
PRIMERGY TX150 S4 Status 25.11.2005
Section
Section
X
S26361-F2425-E103 RSB S2 LP 3HU
RemoteView Service Board S2 Low Profile Version with 3 U bracket for one standard PCI-slot incl. cables and RV SW max. 1x per system
S26361-F2425-E305 RSB S2 LP external power supply
RemoteView Service Board S2 low profile external power supply including power cable with Euro- and Euro socket connector
XI
System management options
Miscellaneous
S26361-F1652-L4
Modem external 56kbps (V.90) MultiTech MT5643ZBA-Global international approval incl. 2m Telephon cord RJ11/RJ11 Adapter Plug RJ11/TAE Serial Interface cable DB25m / DB9f AC-Adapter w. German Power Cord occupies one COM port max. 1x per system
In connection with rack configurations the install variant of the modem (S26361-F1652-E4) has to be ordered (see rack configurator)
K
Fujitsu Siemens Computers
Enterprise Products - PRIMERGY Server
16 of 18
Page 17
System configurator and order-information guide
K
PRIMERGY TX150 S4 Status 25.11.2005
Section
PRIMERGY TX150 S4 Floorstand PRIMERGY TX150 S4 Rack
Power cord for following countries:
1,8 m, grey Country specific power cords are not
T26139-Y1740-E10 D, A, B, F, NL, FIN, S, N, E, P, RUS, TR &Canada. Power cords are shipped in a rack
XII
Country specific / rack specific options
A country specific power cord has to be ordered for all floorstand versions:
- once per basic unit and an additional second cable
- if an second hot plug, redundant power supply modul is ordered.
required for rack versions, except for USA
max. T26139-Y1742-E10 USA, Canada version with inlet connector for non-heating 2 x T26139-Y1743-E10 Switzerland apparatus. (1x with Standard PSU,
T26139-Y1744-E10 UK, Ireland 2x with hot plug upgrade) T26139-Y1745-E10 Italy T26139-Y1746-E10 Denmark T26139-Y1742-E10 USA, Canada T26139-Y3850-E10 No power cord as order option For shipments to USA&Canada, you have to order
Attention: For connection of a monitor to the system an additional country specific power cord has to be ordered as option.
Power cord for optional monitor connection for the following countries:
1.8m, grey
one power cord (1,8m, grey) per power supply.
T26139-Y1740-L10 D, A, B, F, NL, FIN, N, S, E, P, RUS, TR T26139-Y1742-L10 USA, Canada T26139-Y1743-L10 Switzerland T26139-Y1744-L10 UK, IR T26139-Y1745-L10 Italy T26139-Y1746-L10 Denmark
Powercord 3-way splitter 1M to 3F
0.78m, grey T26139-Y3692-L1 Adapter for the connection of up to 3 PS-modules or up to 2 PS-modules and one monitor to the mains connection. Both, standard and hot plug power supplies, are supported.
Other options and Peripherals
For other options refer to the section "Product-specific options These options are supplied loose with the shipment. For suitable peripherals for this product refer to the section "Peripherals/communication".
Option for Floorstand
keyboards for floorstand versions for following countries:
S26381-K397-E110 USA / international S26381-K397-E120 Germany S26381-K397-E140 France S26381-K397-E155 Sweden / Finland S26381-K397-E165 United Kingdom S26381-K397-E180 Spain S26381-K397-E185 Italy
End PRIMERGY TX150 S4
Fujitsu Siemens Computers
Enterprise Products - PRIMERGY Server
17 of 18
Page 18
System configurator and order-information guide
PRIMERGY TX150 S4 Status 25.11.2005
Cange Report
Date
Order number
Changes
2005-11-23 S26361-F1809-E2 ISDN SO Controller PCI Eicon Diva Server BRI-2M 2.0 - now available 2005-03-31 First release
Fujitsu Siemens Computers
Enterprise Products - PRIMERGY Server
18 of 18
Loading...