0System software
IBasic unit
IIProcessor
IIIMemory
IV Graphics
VAccessible drives
VI Hard disk drives
VII SCSI Controller
VIII Disk array
IX Communication/Network
XSystem management options
XI Miscellaneous
XII Country specific options
Change report
PRIMERGY Server
Page 2
System configurator and order-information guide
PRIMERGY TX150 S4 Status 25.11.2005
Instructions
This document contains basic product and configuration information that will enable you to configure your system via
PC-/ System-Architect.
Only these tools will ensure a fast and proper configuration of your PRIMERGY server or your complete
PRIMERGY Rack system.
You can configure your individual PRIMERGY server in order to adjust your specific requirements.
The System configurator is divided into several chapters that are identical to the current price list and PC-/ System-Architect
Please follow the lines. If there is a junction, you can choose which way or component you would like to take. Go through
the configurator by following the lines from the top to the bottom.
Section
In one chapter you can only select as many components (here 4x) as the arrow indicates.
Please note that there are information symbols which indicate necessary information.
Further information in the internet see:
http://www.primergy.com
(internet)
http://extranet.fujitsu-siemens.com/primergy
(extranet)
Prices and availability see price list and PC-/ System-Architect
Subject to change and errors excepted
X times
III
S26361-XXX-XXXS26361-XXX-XXX
Memory XXX MBMemory XXX MB
max. X times per systemmax. X times per system
Memory, example
There are X memory slots which can be equipped with XXX MB.
It is permissible to make up to X passes through the memory upgrade options.
4x
Fujitsu Siemens Computers
Enterprise Products - PRIMERGY Server
2 of 18
Page 3
System configurator and order-information guide
PRIMERGY TX150 S4 Status 25.11.2005
Configuration diagram PRIMERGY TX150 S4
3 x 5.25"
Modul 3
Accessible drives ( V )
Modul 4
Memory ( III )
PCIe x 1
PCIe x 4 (x8 Slot)
(Slot for Zero-Channel Controller)
Key:
System unit ( I )
SIDE VIEWFRONT VIEW
Standard Power Supply
orPS (I) 5.25" x 1.6"
1. PSU 2. PSU
Redundant power supply option 5.25" x 1.6"
5.25" x 1.6" CD / DVD drive
Modul 1
Pentium 4
Bank 1Bank 2
Modul 2
Processor ( II )
Extension slots
SCSI Controller ( VII )
1 PCI-Bus
Disk array ( VIII ) Hard disk drives ( VI )
Communication/Network ( IX )
- VCMS VirtualCenter Management Serverapart from few VMware
- GSX Server and GSX Virtual Infrastructure Nodeadd-ons
- P2V Assistant Enterprise Edition
For all SW products please refer to the corresponding software configurator accessible via
the Extranet under Configuration & Tools, -All configurations, -Software, URL see below.
Microsoft - Software: **)OES/NetWare-Software ***)PRIMECLUSTER *)
- Small Business Server 2003- NetWare- Clustering
- Windows Server 2003,- Load Balancing
Web Edition (only English)
Standard Edition
Enterprise Edition
- Additional looseLinux - Software: **)
Client-Access-Licenses (CALs)- SUSE Linux Enterprise Server
(not for Web Edition)- SUSE Professional Linux
- Red Hat Enterprise Linux
SCO - Software: **)
- SCO OpenServer
- SCO UnixWare
CITRIX-Software für
Windows: W-MF
- Presentation Server
LoadBalancing
Additional User Licences
Later use of OEM operating system
Manageability Software: V**)Details eg. version numbers are published
- RemoteView Softwarein the separate SW-Configurator
- RemoteView Service Board
- RemoteDeploy
- Terminal Server Deploy
- vPMS 2005std
- Altiris Server Deployment
Backup-Software /
Application-Software: U
- ARCserve
- openSM2
Various Software Configurators and release lists (OS-Matrix / System Management / Security) can be optain under the following adresses:
Continue with PRIMERGY
HW configurator
*) Pay attention to the PRIMECLUSTER release and ordering information in the Extranet under
**) Pay attention to the release and ordering information in PRINCE -> Operating System
***) Supply over distribution or procurement from FSC VP BC Software
Later use of OEM operating system
software is not allowed,
apart from few VMware
add-ons
For all SW products please refer to the corresponding software configurator accessible via
the Extranet under Configuration & Tools, -All configurations, -Software, URL see below.
only - Windows Server 2003,only
EM64T x64 Standard EditionEM64T - Red Hat Enterprise Linux
Microsoft - Software: WLinux - Software: L *) **)
x64 Enterprise Edition
- Additional loose
Client-Access-Lizenzen (CALs)
Details eg. version numbers are published
in the separate SW-Configurator
Manageability Software: V**)
- RemoteView Software
- RemoteView Service Board*) Pay attention to release information on datasheet under
- RemoteView Diagnosis
**) Pay attention to release and order information in PRINCE -> Operating System
***) Supply over distribution or procurement from FSC VP BC Software
Various Software Configurators and release lists (OS-Matrix / System Management / Security) can be optain under the following adresses:
Continue with PRIMERGY
HW configurator
Enterprise Products - PRIMERGY Server
Fujitsu Siemens Computers
5 of 18
Page 6
System configurator and order-information guide
Start PRIMERGY TX150 S4
PRIMERGY TX150 S4 Status 25.11.2005
Cables included in basic unit
Connections
Cable
PRIMERGY TX150 S4
1.
IDE CD/DVD
¡¡¡
Key:¥68pins
2.
Backplane for 1x4
¥
68 or 50pins
SCSI hard disks
¥¥¥¥¡
IDE
incl. terminator
terminator
Section
I
Basic unit
System unit consisting of:
* Housing including standard power supply (no redundancy)
* Sliding screen with lock (only for floorstand version)
Systemboard with:
* 7 PCI slots:
1x PCIe x 1
1x PCIe x 4 (x8 Slot)
1x PCI-X 66 long (3,3V)
1x PCI-X 66 (3,3V) ZCR Slot
1x long / 2x short 32Bit / 33MHz (5V)
* 4 memory slots for up to 8GB (PC4200) registered DDR II RAM (ECC), max. 2GB modul per slot
* 1 drive bay 3.5" occupied by 1 floppy disk 1.44MB 1" height (optional)
* 3 Einbauplätze 5,25" für bedienbare Laufwerke
* 4 bays 1" for hot plug SCSI HD)
* ATI Range XL Graphic controller 8MB
* Intel Broadcom (5721) 10/100/1000 Mb/s on-board
* 1 x Fast-IDE (ATA) Controller on-board (for 1x 2 devices)
* 1-channel Ultra 320 SCSI Controller LSI 1020A on-board
with HW RAID IME (IME = Integrated Mirroring Enhanced)
Options:
* Hot plug PS or a second redundant hot plug PS version can be configured by ordering the
appropriate upgrade option
* LSI Zero Channel RAID option, simultaneous use of HD and Tape Drive possible
Cables:
1. IDE cable for CD/DVD
2. With SCSI variant wide LVD SCSI cable for connection of the HD backplane and two
accessible drives
PS/2 mouse (only for floorstand version)
ServerStart packet incl. ServerBooks CD, ServerSupport CD and ServerView
External Interfaces:
2x RS-232-C (serial, 9 pins)
1x Centronics (parallel, 25 pins, EPP/ECP compatible)
1x keyboard (PS/2)
1x mouse (PS/2)
1x VGA (15 pins)
1x USB 2.0 on front and 2x USB 2.0 on rearside
1x LAN RJ45
A
Fujitsu Siemens Computers
Enterprise Products - PRIMERGY Server
6 of 18
Page 7
System configurator and order-information guide
A
PRIMERGY TX150 S4 Status 25.11.2005
Floorstand version SCSI basic unit19" Rack version SCSI basic unit (5 U)
hot plug power supply upgrade optionversionshot plug power supply upgrade option
With this option the basic units containsA second, redundantWith this option the basic units contains
1 hot plug power supply, 1 power power supply requires1 hot plug power supply, 1 power
backplane and 1 dummy coveran additional power backplane and 1 dummy cover
replacing the standard power supplycordreplacing the standard power supply
(no redundancy !)(section XII)(no redundancy !)
max. 1x per systemmax. 1x per system
S26113-F483-E11S26113-F483-E11
2nd power supply module (PSU)2nd power supply module (PSU)
for redundancyfor redundancy
occupies one bay foroccupies one bay for
hot plug power supplyhot plug power supply
max. 1x per systemmax. 1x per system
B1B2
For later conversion of basic units with standard power supply
to hot plug power supply, the following kit is available:
1.) hot plug PS upgrade kit, incl. 2 PS module:S26113-F483-L1
Conversion standard into hot plug PS
2.) Supplementary power supply moduleS26113-F483-L11
for redundancy or repair
Fujitsu Siemens Computers
Enterprise Products - PRIMERGY Server
7 of 18
Page 8
System configurator and order-information guide
B1B2
PRIMERGY TX150 S4 Status 25.11.2005
PRIMERGY FloorstandPRIMERGY Rack
PRIMECENTER- Rack
SNP:SY-F1647E301-P"rack-mounting ex factory"
Installation ex works for oneThis service is to be ordered once
server or subsystemper installable server/storage
Hereby the rack will be delivered subsystem, in order to get the
completely pre-mounted andserver/storage subsystem
all wired connections are testedmounted into the PRIMERGY racks.
With racks 12U, 24U, 38U:In case of the 46 U PRIMERGY rack,
Systems and components this service has to be ordered,
will be delivered installed in the rackto get the mounting kits and the
With racks 46U:cables installed.
Systems and components
will be delivered separately
To be ordered only together with
a PRIMERGYPRIMECENTER rack
e.g.:SNP:SY-K614V10x-P
S26361-K826-V10x
refer configurator PC-rack
max. 1x per System
For later conversion of TX150 base unit floorstand into base unit rack the following kit is availible
1.) Conversion TX150S4 base unit floorstand into base unit rackS26361-F2618-L240
rack mount kit has to be ordered separately
For (later) mounting in racks the following kits are available:
DDR2 533/PC2-4200 ub ECCDDR2 533/PC2-4200 ub ECCDDR2 533/PC2-4200 ub ECC
consisting of one moduleconsisting of one moduleconsisting of one module
occupies one bankoccupies one bankoccupies one bank
max. 3x per systemmax. 3x per systemmax. 3x per system
IV
Processor
Memory
There are 2 memory banks with 2 DIMM slots each.
Single channel memory configuration allow maximum flexibility:
Additional memory can be configured as single memory modules.
Dual channel memory configurations for maximum performance:
For optimum performance memory has to be configured in pairs of memory modules with identical size.
Graphics
ATI Rage XL (8MB)
D
Fujitsu Siemens Computers
Enterprise Products - PRIMERGY Server
9 of 18
Page 10
System configurator and order-information guide
D
PRIMERGY TX150 S4 Status 25.11.2005
Section
SNP:SY-F2234E1-AS26361-F3148-E1
DVD-ROM ATAPIDVD-RW 16x super multi drive
2x
incl. description (Ger/US)only W2K, W3K and Linux
1.6 x 5.25", anthracite bezel1.6 x 5.25", anthracite bezel
max. 2x per systemmax. 1x per system
V
S26361-F2575-E1
Floppy disk drive 1"
Connector: 26pin
incl. description (Ger/US)
1" * 3.5", anthracite bezel
max. 1x per system
Accessible drives
all formats, DUAL/DL, DVD-RAM
There are 3x 5.25" bays for accessible drives:
- 1x 5.25" bay is occupied by a DVD-/CD- respectively a CD-RW drive
- 2 x 5.25" bays remaining, can be occupied by 2x accessible drives
Setup TX150 S4 by ServerStart is supported with following configurations:
no DVD, no CD:
remote installation only ( PXE service & DHCP server required)
built in CD/DVD:
UNC Network share reachable or USB Floppy or MemoryBird connected
One of the following USB devices must be used for integrating the drivers during installation
process if no automized (e.g. Serverstart / Altiris / RIS / ADS / …) installation is done:
1) FDD USB (external): external USB FDD (USB cable included)
2) USB Memorybird: Memorybird 256 MB S26391-F6046-L256
Memorybird 1GB
S26391-F264-L226
S26391-F6046-L24
S26361-F3157-E3
Tape drive LTO2HH Ultrium
200GB, 24MB/s, U160 SCSI
Connector: HD68
without cable
incl. description (Ger/US)
data and cleaning cartridge
without cable
incl. description (Ger/US)
data and cleaning catridge
1.6 x 5.25", anthracite bezel
max. 2x per system
S26361-F2848-E3
Tape drive DDS Gen5
S26361-F2848-E31 (only for OBDR)
DDS-G5 for One buttom dis. recov.
36GB, 3MB/s, U2W SCSI
Connector: HD68
without cable
incl. description (Ger/US)
data and cleaning catridge
1.6 x 5.25", anthracite bezel
max. 2x per system
E
Fujitsu Siemens Computers
Enterprise Products - PRIMERGY Server
10 of 18
Page 11
System configurator and order-information guide
E
PRIMERGY TX150 S4 Status 25.11.2005
S26361-F2814-E6Backup drive and hard disk should run on separate channels
68-Pin Kit for accessible drives
Cable with Terminator
To connect acc. drives to
separate SCSI controller
max. 1x per system
If internal HDD's are connected at the RAID controller
(not IME/ZCR), then for internal accessible drives
the cable S26361-F2814-E6 must be ordered additionally!
Hard disk 73GB in 1" carrierHard disk 146GB in 1" carrierHard disk 300GB in 1" carrier
10000rpm,<5,5ms, 8MB Cache10000rpm,<5,5ms, 8MB Cache10000rpm,<5,5ms, 8MB Cache
Interface: Wide SCA (80-pins) Interface: Wide SCA (80-pins)
hot plug/hot replace trayhot plug/hot replace tray
occupies 1" bayoccupies 1" bay
SCSI/ RAID controller necessarySCSI/ RAID controller necessary
max. 4x per systemmax. 4x per system
F
Fujitsu Siemens Computers
Enterprise Products - PRIMERGY Server
11 of 18
Page 12
System configurator and order-information guide
F
PRIMERGY TX150 S4 Status 25.11.2005
LSI Integrated Mirroring Enhanced (IME) is a RAID 1 implementation (no RAID 0 support). It can be operated also with an odd
Section
VII
SCSI-Controller
All internal cables and adapters are included within the basic units and components respectively
Cabeling priorities:
internal HDs are cabled according to following priorities.
(Prio 1 - 3 ):
1.) For a configuration without any Disk Array Controller and without zero channel RAID
the onboard U320 Controller is connected to the internal HDs.
2.) For a configuration with a 2-channel Disk Array controller (without zero-channel RAID)
One channel will be connected with the internal hard disks.
The second channel is externally available.
internal backup devices are cabled according to following priorities.
(Prio 1 - 2 ):
1) For a configuration without additional SCSI controller
the onboard U320 controller is connected to internal backup devices
2) For a configuration with Adaptec SCSI Card 29160 S26361-F2399-E2
(without SCSI 160 controller S26361-F2644-E11)
this controller is connected to internal backup devices
A. on-board SCSI-controller for accessible drives and SCSI-HDs
1-channel Ultra 320 SCSI on-board controller; included as standard.
Example for IME with 3 data devices:
number of hard disks (max. one RAID 1 Set). There are, depending on system, up to 6 hard disks, including a hot spare disk,
possible. Supportet are only the operating systems Windows2000/2003 as well as SuSE and RedHat Linux.
All internal cables and adapters for the basic unit and for components are included.
1x per TX150S4
T26139-Y3849-L1
External on-board SCSI Interfaceconnection of the on-board SCSI controller
Cable and externaland the 29160.
connector interface (HD68)Cable sold separately not mounted in factory.
occupies one connection panelUse this cable only if on-board controller is not
max. 1x per system for ext.used otherwise (eg. S26361-F2814-E6)
G
Only SX10 Backup is released for the external
Fujitsu Siemens Computers
Enterprise Products - PRIMERGY Server
12 of 18
Page 13
System configurator and order-information guide
G
PRIMERGY TX150 S4 Status 25.11.2005
B. SCSI controller for internal backup drives
S26361-F2399-E2
SCSI 160 Controller
Adaptec SCSI Card 29160
1 channel: LVD + Fast/ Ultra (decoupl.)
LVD connect. for HD, without cable
Fast/Ultra connect. for acc. drives
64/66 PCI, min 180 mm
int: Fast 50-pin or Ultra HD68
+ LVD HD68; ext: HD68(LVD)
SW:
max. 1x per system
S26361-F2814-E6
68-Pin Kit for accessible drives
Cable with Terminator
To connect acc. drives to
separate SCSI controller
max. 1x per system
C. SCSI controller for external drives and peripheral devices
Section
max. 4x
S26361-F2399-E1
SCSI U160 controller
Adaptec SCSI Card 29160
1 channel: LVD + Fast/ Ultra (decoupl.)
LVD connect. for HD, without cable
Fast/Ultra connect. for acc. drives
64/66 PCI, min 180 mm
int: Fast 50 pol oder Ultra HD68
+ LVD HD68; ext: HD68(LVD)
SW:
max. 1x per system
VIII
D. LSI - Controller
1-channel Ultra 320 SCSI on-board controller with LSI Integrated Mirroring (IME)
Standard SCSI-cabling of a PRIMERGY TX150 S4 basic unit with on-board controller
Ultra 320 SCSI controller is connected to the internal hard disks and internal backup devices,
if no additional HD/backup device controllers are configured.
1x per PRIMERGY TX150 S4
S26361-F3085-E128
0-channel RAID controller
LSI
320-0x
128MB SDRAM ECC Cache
BBU optional
in combination with on-board
U320 SCSI controllerblue marked bay.
without cable
64Bit/133MHz PCI-X controller
3.3V power supply & signalingthe IME function is no longer
max. 1x per system
Disk Array
D. zero-channel RAID controller (320-0x) for internal Disk Array
and additional RAID controllers for internal / external Disk Array
Zero channel RAID controller
LSI must be installed in the
With zero channel RAID controller
available.
Only SX10 Backup is for external
connection at the SCSI controller.
S26361-F3085-E10
Cache Battery Backup Unit
to be
continued
on next page
max. 1x pro Controller
H
Fujitsu Siemens Computers
Enterprise Products - PRIMERGY Server
13 of 18
Page 14
System configurator and order-information guide
H
PRIMERGY TX150 S4 Status 25.11.2005
continued
on previousE. 2-Kanal Ultra 320 SCSI Controller für Disk Array
The fitting connection cables can be found in the configurator
of the external storage system and / or rack.
S26361-F2814-E6 Backup drive and HDD should run on separate channels.
68-Pin Kit for accessible drives
Cable with Terminator
To connect acc. drives to
separate SCSI controller
max. 1x per system
If internal HDD's are connected at the RAID controller
(not IME/ZCR), then for internal accessible drives
the cable S26361-F2814-E6 must be ordered additionally!
I
Fujitsu Siemens Computers
Enterprise Products - PRIMERGY Server
14 of 18
Page 15
System configurator and order-information guide
I
PRIMERGY TX150 S4 Status 25.11.2005
4x
Section
IX
Gigabit Ethernet Contr. on-boardThe Intel LAN controllers 1000MT can be used
Broadcomwith the on-board controller in Teaming Mode
ext: for RJ 45-connector
SW: AFT, VLAN, Fast Channel
S26361-F3053-E1S26361-F3142-E1
Gigabit Ethernet Contr. 1000TXGigabit Ethernet Contr. 1000TX
Eth. Ctrl 1x1Gbit PCI-X Pro/1000MT Cu Eth. Ctrl 1x1Gbit PCI32 PRO/1000GT Cu
Intel PRO/1000 MT Server AdapterIntel Pro/1000 GT Adapter
Adapter Teaming Support
PCI-X (PCI64/133), min 165 mmext: for RJ45-plug, Cat 5
ext: for RJ45-plug, Cat 5
connection with Cat 5 cablingSW: VLAN, Fast & Gbit Etherchannel
SW: VLAN, Fast & Gbit Etherchannel
max. 4x per system
S26361-F3011-E1
Gigabit Ethernet Contr dual 1000TX
Intel Pro/1000MT dual Server Adapter
Adapter Teaming Support
PCI-X (PCI64/133), min 163 mm
ext: for RJ45-plug, Cat 5
connection with Cat 5 cabling
SW: VLAN, Fast Etherchannel
max. 2x per system
Communication / Network
PCI 32 (33/66MHz),
connection with Cat 5 cabling
max. 4x per system
S26361-F1809-E2
ISDN SO Controller PCI
Eicon Diva Server BRI-2M 2.0
Incl. SO-connector
occu. short PCI slot min. 170 mm
SO-Interface
max. 2x per system
J
Fujitsu Siemens Computers
Enterprise Products - PRIMERGY Server
15 of 18
Page 16
System configurator and order-information guide
J
PRIMERGY TX150 S4 Status 25.11.2005
Section
Section
X
S26361-F2425-E103
RSB S2 LP 3HU
RemoteView Service Board S2
Low Profile Version with 3 U bracket
for one standard PCI-slot
incl. cables and RV SW
max. 1x per system
S26361-F2425-E305
RSB S2 LP external power supply
RemoteView Service Board S2
low profile external power supply
including power cable
with Euro- and Euro socket connector
XI
System management options
Miscellaneous
S26361-F1652-L4
Modem external 56kbps (V.90)
MultiTech
MT5643ZBA-Global
international approval
incl. 2m Telephon cord RJ11/RJ11
Adapter Plug RJ11/TAE
Serial Interface cable DB25m / DB9f
AC-Adapter w. German Power Cord
occupies one COM port
max. 1x per system
In connection with rack configurations
the install variant of the modem
(S26361-F1652-E4) has to be ordered
(see rack configurator)
T26139-Y1740-E10D, A, B, F, NL, FIN, S, N, E, P, RUS, TR&Canada. Power cords are shipped in a rack
XII
Country specific / rack specific options
A country specific power cord has to be ordered for all floorstand versions:
- once per basic unit and an additional second cable
- if an second hot plug, redundant power supply modul is ordered.
required for rack versions, except for USA
max. T26139-Y1742-E10USA, Canadaversion with inlet connector for non-heating
2 xT26139-Y1743-E10Switzerlandapparatus. (1x with Standard PSU,
T26139-Y1744-E10UK, Ireland2x with hot plug upgrade)
T26139-Y1745-E10Italy
T26139-Y1746-E10DenmarkT26139-Y1742-E10USA, Canada
T26139-Y3850-E10No power cord as order optionFor shipments to USA&Canada, you have to order
Attention: For connection of a monitor
to the system an additional country
specific power cord has to be
ordered as option.
Power cord for optional monitor connection for the following countries:
1.8m, grey
one power cord (1,8m, grey) per power supply.
T26139-Y1740-L10D, A, B, F, NL, FIN, N, S, E, P, RUS, TR
T26139-Y1742-L10USA, Canada
T26139-Y1743-L10Switzerland
T26139-Y1744-L10UK, IR
T26139-Y1745-L10Italy
T26139-Y1746-L10Denmark
Powercord 3-way splitter 1M to 3F
0.78m, grey
T26139-Y3692-L1
Adapter for the connection of up to 3 PS-modules or up to
2 PS-modules and one monitor to the mains connection.
Both, standard and hot plug power supplies, are supported.
Other options and Peripherals
For other options refer to the section "Product-specific options
These options are supplied loose with the shipment.
For suitable peripherals for this product refer to the section "Peripherals/communication".
Option for Floorstand
keyboards for floorstand versions for following countries:
S26381-K397-E110USA / international
S26381-K397-E120Germany
S26381-K397-E140France
S26381-K397-E155Sweden / Finland
S26381-K397-E165United Kingdom
S26381-K397-E180Spain
S26381-K397-E185Italy
End PRIMERGY TX150 S4
Fujitsu Siemens Computers
Enterprise Products - PRIMERGY Server
17 of 18
Page 18
System configurator and order-information guide
PRIMERGY TX150 S4 Status 25.11.2005
Cange Report
Date
Order number
Changes
2005-11-23 S26361-F1809-E2ISDN SO Controller PCI Eicon Diva Server BRI-2M 2.0 - now available
2005-03-31First release
Fujitsu Siemens Computers
Enterprise Products - PRIMERGY Server
18 of 18
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.