Fujitsu TX150 S3 User Manual

Page 1
PRIMERGY
PRIMERGY TX150 S3 Server System
Options Guide
Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001155 Fax: (++49) 700 / 372 00000 U41604-Z156-1-76 Sprachen: En
Edition January 2005
Page 2
CommentsSuggestionsCorrections
The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our documentation to suit your individual needs.
Fax forms for sending us your comments are included in the back of the manual.
There you will also find the addresses of the relevant User Documentation Department.
Certified documentation according to DIN EN ISO 9001:2000
To ensure a consistently high quality standard and user-friendliness, this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001:2000.
cognitas. Gesellschaft für Technik-Dokumentation mbH www.cognitas.de
Copyright and Trademarks
Copyright © 2005 Fujitsu Siemens Computers GmbH.
All rights reserved. Delivery subject to availability; right of technical modifications reserved.
All hardware and software names used are trademarks of their respective manufacturers.
This manual is printed on paper treated with chlorine-free bleach.
Page 3
Introduction
Procedure
Safety notes
Preparation
Main memory
Accessible drives
Controller in the PCI slots
RemoteView components
External SCSI interface
Conversion standard PS to hot-plug PS
Continued
Page 4
Page 5
Converting from the floorstand model to the rack model
Completion
Appendix
Abbreviations, Related publications and Index
Page 6
Page 7

Contents

1Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.1 Overview of the documentation . . . . . . . . . . . . . . . . . . 1
1.2 Extensions and conversions . . . . . . . . . . . . . . . . . . . . 2
1.3 Notational conventions . . . . . . . . . . . . . . . . . . . . . . . 4
2 Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3 Safety notes . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4 Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
4.1 Floorstand model . . . . . . . . . . . . . . . . . . . . . . . . 13
4.1.1 Opening the server . . . . . . . . . . . . . . . . . . . . . . . 13
4.1.2 Removing the front cover . . . . . . . . . . . . . . . . . . . . 14
4.1.3 Removing the hard disk cover . . . . . . . . . . . . . . . . . . 15
4.2 Rack model . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
4.2.1 Opening the server . . . . . . . . . . . . . . . . . . . . . . . 16
4.2.2 Removing the rack front cover . . . . . . . . . . . . . . . . . . 19
5Main memory . . . . . . . . . . . . . . . . . . . . . . . . . . 21
5.1 Equipping rules . . . . . . . . . . . . . . . . . . . . . . . . . 21
5.2 Extending/replacing the main memory . . . . . . . . . . . . . 22
6 Accessible drives . . . . . . . . . . . . . . . . . . . . . . . 25
6.1 Installing an accessible 5.25-inch drive . . . . . . . . . . . . . 25
6.2 Installing the hard disks extension box . . . . . . . . . . . . . 29
7 Controller in the PCI slots . . . . . . . . . . . . . . . . . . . 31
7.1 Installing a controller . . . . . . . . . . . . . . . . . . . . . . . 32
7.2 PCI slot assembling . . . . . . . . . . . . . . . . . . . . . . . 34
8 RemoteView components . . . . . . . . . . . . . . . . . . . 35
8.1 RemoteView Service Board S2 LP . . . . . . . . . . . . . . . 35
9 External SCSI interface . . . . . . . . . . . . . . . . . . . . 39
9.1 Installing the external SCSI interface . . . . . . . . . . . . . . 39
10 Conversion standard PS to hot-plug PS . . . . . . . . . . . 41
11 Converting from the floorstand model to the rack model . . 53
12 Completion . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
12.1 Floorstand model . . . . . . . . . . . . . . . . . . . . . . . . 59
U41604-Z156-1-76 Options Guide
Page 8
Contents
12.1.1 Attaching the hard disk cover . . . . . . . . . . . . . . . . . . . 59
12.1.2 Attaching the front cover . . . . . . . . . . . . . . . . . . . . . 60
12.1.3 Closing the server . . . . . . . . . . . . . . . . . . . . . . . . . 61
12.2 Rack model . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
12.2.1 Attaching the rack front cover . . . . . . . . . . . . . . . . . . 62
12.2.2 Closing the server . . . . . . . . . . . . . . . . . . . . . . . . . 64
13 Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
13.1 Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
13.1.1 SCSI version . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
13.1.2 SATA version . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Related publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Options Guide U41604-Z156-1-76
Page 9

1 Introduction

The PRIMERGY TX150 S3 Server is an Intel-based server for medium-sized networks and large companies. The server is suitable for use as a file server as well as an application, information, or Internet server. It is available as a floor­stand or rack model. The floorstand model can be converted to a rack model using an optional conversion kit.

1.1 Overview of the documentation

I PRIMERGY manuals are available in PDF format on the ServerBooks CD
which is supplied in the ServerView Suite package for every server system.
These PDF files can also be downloaded free of charge from the Internet: at http://manuals.fujitsu-siemens.com you will find an overview page with the online documentation available on the Internet. You can go to the PRIMERGY Server documentation by clicking on “intel based Servers”.
Concept and target groups
This Options Guide shows you how you can expand and upgrade the server.
I The Operating Manual for the server describes how you install/remove
the hot-plug components.
The activities described in this manual may only be performed by technicians, service personnel or technical specialists.
Additional documentation about the server
The PRIMERGY TX150 S3 documentation comprises the following additional manuals:
– The “Security” manual (printed copy always supplied with the server, and
available as a PDF file on the ServerBooks CD supplied)
– The “Guarantee” manual (printed copy always supplied with the server, and
available as a PDF file on the ServerBooks CD supplied)
– The Operating Manual for the PRIMERGY TX150 S3 (PDF available on the
ServerBooks CD supplied)
U41604-Z156-1-76 Options Guide 1
Page 10

Extensions and conversions Introduction

– The Technical Manual for the system board D1979 (PDF available on the
ServerBooks CD supplied) – The “BIOS Setup” manual (PDF available on the ServerBooks CD supplied) – The “PRIMERGY ServerView Suite - ServerStart” manual (printed copy
always supplied with the server, and available as PDF file on the ServerBooks
CD supplied) – The “Global Array Manager Client Software User’s Guide” (PDF available on
the ServerBooks CD supplied) – The “Integrated Mirroring User’s Guide” (PDF available on the ServerBooks
CD supplied)
I You can order a supplementary ServerBooks CD by sending an e-mail to
the following address, quoting your server data:
Reklamat-PC-LOG@fujitsu-siemens.com
Further sources of information:
– Technical Manual on the relevant rack – Manual on the monitor – Manual on ServerView Server Management – Manual on the RemoteView Remote Test and Diagnostics System – Documentation on boards and drives – Documentation on your operating system – Information files on your operating system
(see also “Related publications” on page 79)
1.2 Extensions and conversions
Extension of the main memory
The four slots for the main memory are suitable for DDR1 333/400 MHz (unbuf­fered) SDRAM memory modules. The organization in two memory banks, 1 and 2, permits rapid memory access with two-way interleaving.
If the memory modules are populated in pairs, each pair must consist of identical memory modules (2-way interleaved mode).
Additional SATA hard disk drives
In the SATA version four bays are available for SATA hard disk drives.
2 Options Guide U41604-Z156-1-76
Page 11
Introduction Extensions and conversions
Additional accessible drives
Three 5.25-inch bays are available for accessible drives. The top side bay is already occupied by a CD/DVD ROM drive.
Hard disks extension box
In the SCSI version the two lower 5.25-inch bays for accessible drives can be used to integrate a hard disks extension box.
The hard disks extension box enables up to three additional HDD modules to be integrated. Each HDD module can accommodate a SCSI hard disk drive with an SCA (Single Connector Attachment) interface and a height of at most 1 inch. The connection to the SCSI backplane is made without cables via the SCA interface. This makes it simple to plug in or pull out the HDD modules. If the server has a RAID controller and the corresponding RAID configuration, defective HDD modules can also be replaced while the system is operating.
Additional controllers in the PCI slots
The system board offers six PCI slots: 2 x PCI-X (64 Bit / 66 MHz), 3 x PCI (32 Bit / 33 MHz) and 1 x PCI-Express x1 slot.
The PCI slot 2 is prepared for Zero Channel RAID (ZCR).
RemoteView Service Board S2 LP
The RemoteView Service Board S2 LP (RSB S2 LP) is a PCI board with a completely independent system, i.e. it has its own operating system with Web server and SNMP agents and can optionally be equipped with an external power supply. The RSB S2 LP permits remote diagnosis for system analysis, remote system configuration and remote restart even in the event of operating system failure or hardware faults. It has its own LAN connection and its own COM port. All the functions of the RSB S2 LP are thus available either via a LAN or modem.
External SCSI interface
If the internal hard disks are connected via a PCI RAID controller, one channel of the on-board controller can also be made available for connecting a peripheral cabinet SX10 via an external SCSI interface.
U41604-Z156-1-76 Options Guide 3
Page 12

Notational conventions Introduction

Conversion standard power supply to hot-plug power supply
The standard power supply can be replaced by a hot-plug power supply. The hot-plug power supply consists of two power supply modules.
If one power supply module fails, the other power supply module guarantees the unrestricted operation and the defective power supply module can be replaced be replaced while the system is operating (hot-plug).
Conversion of the floorstand model to a rack model
The floorstand model can optionally be converted so that the server can be integrated into the common rack systems.
1.3 Notational conventions
The following notational conventions are used in this manual:
Text in italics indicates commands, menu items or software programs. „Quotation marks“ indicate names of chapters and terms that are being
emphasized.
Ê describes activities that must be performed in the order
shown.
V CAUTION! pay particular attention to texts marked with this symbol.
Failure to observe this warning may endanger your life, destroy the system or lead to the loss of data.
I indicates additional information, notes and tips.
Table 1: Notational conventions
4 Options Guide U41604-Z156-1-76
Page 13
2Procedure
V CAUTION!
The actions described in these instructions should only be performed by technicians, service personnel or technical specialists. Equipment repairs should only be performed by authorized, qualified staff. Any unauthorized opening and improper repairs could expose the user to risks (electric shock, energy hazards, fire hazards) and could also damage the equipment. Please note that any unauthorized opening of the device will result in the invalidation of the warranty and exclusion from all liability.
Ê First of all please familiarize yourself with the safety instructions in the
section chapter “Safety notes” on page 7 et seqq. .
Ê Ensure that all required manuals (see “Additional documentation about the
server” on page 1) are available, printing out the PDF files if necessary. You will definitely need the Operating Manual for the server and the Technical Manual for the system board.
Ê Shut down the server correctly, switch it off, pull out the power plug(s), and
open the server as described in the chapter “Preparation” on page 13 et seqq. .
Ê Extend or upgrade your server as described in the relevant chapter.
I The Operating Manual for the server describes how you
install/remove the hot-plug components.
I Procedures which are identical for the floorstand and rack models are
only described for the floorstand model.
Ê Close the server, connect it to the power outlet, and switch it on as described
in the chapter “Completion” on page 59 et seqq. .
Ê Start the operating system and, if necessary, configure it as required (see
the Operating Manual).
U41604-Z156-1-76 Options Guide 5
Page 14
Page 15

3 Safety notes

I The following safety notes are also provided in the “Safety” manual.
This device complies with the relevant safety regulations for data processing equipment.
If you have any questions about where you can set up the device, contact your sales outlet or our customer service team.
V CAUTION!
The actions described in these instructions should only be performed by technicians, service personnel or technical specialists. Equipment repairs should only be performed by authorized, qualified staff. Any unauthorized openings and improper repairs could expose the user to risks (electric shock, energy hazards, fire hazards) and could also damage the equipment. Please note that any unauthorized openings of the device will result in the invalidation of the warranty and exclusion from all liability.
Before operating the device
V CAUTION!
During installation and before operating the device, observe the
instructions on environmental conditions for your device.
If the device is brought in from a cold environment, condensation may
form both inside and on the outside of the machine. Wait until the device has acclimatized to room temperature and is
absolutely dry before starting it up. Material damage may be caused to the device if this requirement is not observed.
Transport the device only in the original packaging or in packaging
that protects it from knocks and jolts.
U41604-Z156-1-76 Options Guide 7
Page 16
Safety notes
Installation and operation
V CAUTION!
If the rack model is integrated in an installation that receives power
from an industrial (public) power supply network with the IEC309 connector, the (public) power supply protection must comply with the requirements for the non-industrial (public) power supply networks for the type A connector.
The server automatically sets itself to a voltage in the range of
100 V to 240 V. Make sure that your local voltage is within this range.
This device has a specially approved power cable and must only be
connected to a grounded insulated socket.
Ensure that the power socket on the device or the grounded wall
outlet is freely accessible.
The ON/OFF button does not disconnect the device from the mains
voltage. To disconnect the line voltage completely, remove the power plug(s) from the grounded insulated socket(s).
V CAUTION!
Always connect the device and the attached peripherals to the same
power circuit. Otherwise you run the risk of losing data if, for example, the central processing unit is still running but the peripheral device (e.g. storage subsystem) has failed during a power outage.
Data cables to peripheral devices must be adequately shielded.
To the LAN wiring the requirements apply in accordance with the
standards EN 50173 and EN 50174-1/2. As minimum requirement the use of a protected LAN line of category 5 for 10/100 MBps Ethernet, and/or of category 5e for Gigabit Ethernet is considered. The requirements of the specification ISO/IEC 11801 are to be considered.
Route the cables in such a way that they do not form a potential
hazard (make sure no-one can trip over them) and that they cannot be damaged. When connecting up a device, refer to the relevant notes in this manual.
Never connect or disconnect data transmission lines during a storm
(lightning hazard).
8 Options Guide U41604-Z156-1-76
Page 17
In emergencies (e.g. damaged casing, controls or cables, penetration
of liquids or foreign matter), switch off the device immediately, remove the power plug and contact your sales outlet or customer service team.
Proper operation of the device (in accordance with IEC 60950/
EN 60950) is only ensured if the casing is completely assembled and the rear covers for the installation openings have been put in place (electric shock, cooling, fire protection, interference suppression).
Only install system expansions that satisfy the requirements and
rules governing safety and electromagnetic compatibility and relating to telecommunications terminal equipment. If you install other expan­sions, you may damage the system or violate the safety regulations and regulations governing RFI suppression. Information on which system expansions are suitable can be obtained from the customer service centre or your sales outlet.
V CAUTION!
The components or parts marked with a warning label (e.g. lightning
symbol) may only be opened, removed or exchanged by authorized, qualified personnel. The hot-plug power supply units are exceptions to this rule.
Safety notes
The warranty expires if the device is damaged during the installation
or replacement of system expansions.
You may only set those resolutions and refresh rates specified in the
„Technical data“ section of the monitor description. Otherwise, you may damage your monitor. If you are in any doubt, contact your sales outlet or customer service centre.
U41604-Z156-1-76 Options Guide 9
Page 18
Safety notes
Batteries
V CAUTION!
Incorrect replacement of batteries may lead to a risk of explosion. The
batteries may only be replaced with identical batteries or with a type recommended by the manufacturer (see the technical manual for the system board under “Related publications” on page 79).
Do not throw batteries into the trash can. They must be disposed of
in accordance with local regulations concerning special waste.
The battery must be disposed of in accordance with local regulations
concerning special waste.
Replace the lithium battery on the system board in accordance with
the instructions in the technical manual for the system board (see “Related publications” on page 79).
All batteries containing pollutants are marked with a symbol (a
crossed-out garbage can). In addition, the marking is provided with the chemical symbol of the heavy metal decisive for the classification as a pollutant:
Cd Cadmium Hg Mercury Pb Lead
10 Options Guide U41604-Z156-1-76
Page 19
Safety notes
Notes on handling CDs and CD-/DVD-ROM drives
V CAUTION!
Use only CDs in proper condition in the CD-/DVD-ROM drive of your
server to prevent data loss, damage to the device and injuries.
Therefore, check each CD for damage, cracks, breakage etc. before
inserting it in the drive. Please note that any additional labels applied may change the
mechanical properties of a CD and cause imbalance. Damaged and imbalanced CDs can break at high drive speeds (data
loss). Under certain conditions sharp-edged pieces of broken CDs can
penetrate the cover of the drive (damage to the device) and be thrown out of the device (danger of injury, particularly on uncovered body parts such as the face or neck).
I You protect the CD-/DVD-ROM drive and prevent mechanical damage,
as well as premature wearing of the CDs, by observing the following suggestions:
– Only insert the CDs in the drive when needed and remove them after
use. – Store the CDs in suitable sleeves. – Protect the CDs from exposure to heat and direct sunlight.
Note about the laser
The CD-/DVD-ROM drive
is classified for
laser class 1according to IEC 60825-1.
V CAUTION!
The CD-/DVD-ROM drive contains a laser diode (LED). Sometimes the LED produces a stronger laser beam than laser class 1. Direct view into this laser beam is dangerous.
Never remove parts of the CD-/DVD-ROM drive assembly!
U41604-Z156-1-76 Options Guide 11
Page 20
Safety notes
Modules with electrostatic-sensitive components:
Systems and components that might be damaged by electrostatic discharge (ESD) are marked with the following label:
Figure 1: ESD label
When you handle components fitted with ESDs, you must observe the following points under all circumstances:
Remove the power plug from the power socket before inserting or removing
components containing ESDs.
You must always discharge yourself of static charges (e.g. by touching a
grounded object) before working.
The equipment and tools you use must be free of static charges.
Only touch the components at the positions highlighted in green (touch
points).
Do not touch any exposed pins or conductors on a component.
Use a grounding cable designed for this purpose to connect yourself to the
system unit as you install components.
Place all components on a static-safe base.
I You will find a detailed description for handling ESD components in the
relevant European or international standards (DIN EN 61340-5-1, ANSI/ESD S20.20).
12 Options Guide U41604-Z156-1-76
Page 21

4 Preparation

V CAUTION!
Observe the safety instructions in the chapter “Safety notes” on page 7 et seqq. .

4.1 Floorstand model

4.1.1 Opening the server

Ê Terminate all applications and shut down the server correctly. Ê If your operating system has not switched off the sever, press the on/off
switch.
Ê Pull all power connectors out of the power outlets. Ê If required, remove the lock on the side cover.
1
4
3
2
Figure 2: Loosening the screws
Ê Unlock the server (1). Ê Loosen the two screws at the rear side (2). Ê Push back the left-hand side cover approxiate 2 cm (3). Ê Remove the left-hand side cover (4).
U41604-Z156-1-76 Options Guide 13
Page 22
Floorstand model Preparation

4.1.2 Removing the front cover

Remove the front cover when making the following extensions and upgrades: – Installing further accessible drives – Upgrading the floorstand model to a rack model
Ê Remove the hard disk cover as shown in figure 5 on page 15.
2
1
Figure 3: Removing the front cover
Ê Disengage the three tabs (1) on the left side one after the other and rotate
the front cover outward (2) about 2 cm.
2
1
Figure 4: Removing the front cover
Ê Press the two hooks (1) on the right side inward and pull out the front cover
frontward (2).
14 Options Guide U41604-Z156-1-76
Page 23
Preparation Floorstand model

4.1.3 Removing the hard disk cover

Remove the hard disk cover when making the following extensions and upgrades: – Installing further SATA hard disk drives
Ê Terminate all applications and shut down the server correctly. Ê If your operating system has not switched off the sever, press the on/off
switch.
2
1
4
3
Figure 5: Removing the hard disk cover
Ê Unlock the server (1) and remove the key. Ê Push the drive cover up as far as possible (2). Ê Remove the hard disk cover (3 + 4).
U41604-Z156-1-76 Options Guide 15
Page 24

Rack model Preparation

4.2 Rack model
Ê Terminate all applications and shut down the server correctly. Ê If your operating system has not switched off the server, press the on/off
button.
Ê Pull all power connectors out of the power outlets.

4.2.1 Opening the server

1
2
Figure 6: Loosening the knurled screws
Ê Loosen the four knurled screws (1) and pull the server as far as possible out
of the rack (2).
16 Options Guide U41604-Z156-1-76
Page 25
Preparation Rack model
2
1
Figure 7: Loosening the locking spring
Ê Press in the locking spring (1) on both sides and carefully pull the server
outward (2).
2
Figure 8: Removing the server from the rack cabinet
Ê Disconnect all cables on the rear of the server. Ê Remove the telescopic rails on the left and right side (three screws).
U41604-Z156-1-76 Options Guide 17
Page 26
Rack model Preparation
V CAUTION!
At least two people are needed to lift the server out of the rack cabinet.
Ê Lift the server out of the rails and place it on a table, for example.
3
1
Figure 9: Loosening the screws
Ê Unlock the top cover by removing the two screws at the rear side (1). Ê Push back the top cover approxiate 2 cm (2). Ê Remove the top cover (3).
2
2
18 Options Guide U41604-Z156-1-76
Page 27
Preparation Rack model

4.2.2 Removing the rack front cover

Remove the rack front cover when carrying out the following extension: – Installing further accessible drives
1
2
1
Figure 10: Removing the rack front cover
Ê Remove two screws on either side (1). Ê Remove the rack front cover to the front (2).
1
2
4
3
Figure 11: Removing the plastic front cover
Ê Disengage the three tabs (1) on the top side one after the other and pull out
the plastic front cover frontward (2) about 2 cm.
Ê Press the two hooks (3) on the bottom side downward and pull out the plastic
front cover frontward (4).
U41604-Z156-1-76 Options Guide 19
Page 28
Page 29
5Main memory
V CAUTION!
Observe the safety instructions in the chapter “Safety notes” on page 7 et seqq. .
The system board supports up to 4 Gbytes of main memory. Four slots (2 slots form a memory bank) are provided for the main memory. Each memory bank can be equipped with 256 Mbyte, 512 Mbyte or 1 Gbyte unbuffered DDR I memory modules.

5.1 Equipping rules

DIMM 1A
DIMM 2A
DIMM 1B
DIMM 2B
Figure 12: Structure of the main memory in memory banks and memory modules
– Each memory bank is equipped with two memory modules with the same
capacity. Memory access takes place in 2-way interleaved mode.
– The memory module capacity can differ for the various memory banks: e.g.
memory bank 2A/2B can be equipped with two 512 Mbyte memory modules, and memory bank 1A/1B with two 1 Gbyte memory modules.
U41604-Z156-1-76 Options Guide 21
Page 30

Extending/replacing the main memory Main memory

The table below shows the order in which the memory banks must be equipped:
DIMM_1A DIMM_2A DIMM_1B DIMM_2B
single channel
dual channel equipped empty equipped empty
equipped empty empty empty
empty equipped empty empty empty empty equipped empty empty empty empty equipped
empty equipped empty equipped
equipped equipped equipped equipped
5.2 Extending/replacing the main memory
Ê Open the server as described in the chapter “Preparation” on page 13 et
seqq. .
1
Figure 13: Removing a memory module
2
1
Ê Press the holders on either side of the mounting location concerned outward
(1).
Ê If the mounting location was already equipped: pull the memory module out
of the mounting location (2).
22 Options Guide U41604-Z156-1-76
Page 31
Main memory Extending/replacing the main memory
2
2
Figure 14: Inserting a memory module
Ê Press the holders on either side of the mounting location concerned
outward.
Ê Insert the memory module in the mounting location (1) until the holders at
the sides engage (2).
Ê Close the server, connect it to the power outlet, and switch it on as described
in the chapter “Completion” on page 59 et seqq. .
U41604-Z156-1-76 Options Guide 23
Page 32
Page 33

6 Accessible drives

V CAUTION!
Observe the safety instructions in the chapter “Safety notes” on page 7 et seqq. .
Three 5.25-inch bays are available for accessible drives. The top side bay is already equipped with a CD/DVD-ROM drive. The two lower bays can also be used to install a hard disks extension box.

6.1 Installing an accessible 5.25-inch drive

The 5.25-inch drives available are magnetic tape drives, CD/DVD-ROM drives and CD/DVD-ROM burners. These drives can be installed in the two free 5.25­inch bays.
Ê Open the server and remove the front cover or rack front cover as described
in the chapter “Preparation” on page 13 et seqq. .
I New 5.25-inch drives are supplied without EasyClick rails. Before
installing a new drive you must therefore remove the EasyClick rails from the dummy cover and mount the EasyClick rails on the new drive.
1
1
2
1
Figure 15: Removing the dummy cover
Ê Press the two metal tongues of the EasyClick rails inward (1) until the locking
mechanism is released.
Ê Remove the dummy cover from the bay (2).
U41604-Z156-1-76 Options Guide 25
Page 34
Installing an accessible 5.25-inch drive Accessible drives
Ê Remove the EasyClick rails from the dummy cover by removing the four
screws on each side.
I Note that there are two M3 screws and two UNC screws on each side.
V CAUTION!
Keep the dummy cover for future use. If you remove the accessible drive again and do not replace it with a new one, the dummy cover must be reinstalled to comply with EMC regulations and to satisfy cooling require­ments and fire protection measures.
1
1
Figure 16: Attaching the EasyClick rails - DVD-ROM burner
Ê Screw the EasyClick rails onto either side of the new 5.25-inch drive using
two M3x4.5mm screws (1). Use the first hole in each upper row of holes as shown in the figure.
I Keep the remaining screws for future use. The different drives are
fastened using different screws. Starting on the next page, you will find figures which show the attaching of the EasyClick rails for magnetic tape drives.
Ê Push the new drive about halfway into the bay. Ê Connect the data cable to the accessible drive (see the cabling plans in the
Appendix).
Ê Connect the power cable to the accessible drive (see the cabling plans in the
Appendix).
Ê Push the drive fully into the bay until the EasyClick rails latch in place.
26 Options Guide U41604-Z156-1-76
Page 35
Accessible drives Installing an accessible 5.25-inch drive
Ê Attach the front cover or rack front cover, close the server, connect it to the
power outlet, and switch it on as described in the chapter “Completion” on page 59 et seqq. .
You will find in the following figures which holes and screws should be used for the magnetic tape dives.
Figure 17: Attaching the EasyClick rails - magnetic tape drive LTO Ultrium 1HH
Figure 18: Attaching the EasyClick rails - magnetic tape drive LTO Ultrium 2FH
U41604-Z156-1-76 Options Guide 27
Page 36
Installing an accessible 5.25-inch drive Accessible drives
Figure 19: Attaching the EasyClick rails - magnetic tape drive VXA-2
Figure 20: Attaching the EasyClick rails - magnetic tape drive DDS Gen5
28 Options Guide U41604-Z156-1-76
Page 37

Accessible drives Installing the hard disks extension box

6.2 Installing the hard disks extension box
In the SCSI version the two lower 5.25 inch bays for accessible drives can be used to install a HDD extension box. But it is required that the server is equipped with a 1- or 2-channel RAID controller.
I It is not allowed to operate the hard disks of the HDD extension box
together with the internal hard disks via one common SCSI line.
If the server has a RAID controller and a corresponding RAID configuration, defective hard disk modules can also be exchanged during operation.
Ê Open the server and remove the front cover or rack front cover as described
in the chapter “Preparation” on page 13 et seqq. .
I The hard disks extension box is supplied without EasyClick rails. You
need 8 M3 screws. Before installing a new hard disks extension box you must therefore remove the EasyClick rails from the two dummy covers and mount two of the four EasyClick rails on the hard disks extension box.
Ê Remove the dummy covers from the two lower 5.25-inch bays for accessible
drives: Ê Press the two metal tongues of the EasyClick rails inward (1) until the
locking mechanism is released.
Ê Remove the dummy cover from the bay.
Ê Remove the EasyClick rails from the two dummy covers by removing the four
screws on each side.
I Note that there are two M3 screws and two UNC screws on each side.
V CAUTION!
Keep the dummy covers for future use. If you remove the hard disks
extension box again and do not replace it with new drives, the dummy
covers must be reinstalled to comply with EMC regulations and to
satisfy cooling requirements and fire protection measures.
U41604-Z156-1-76 Options Guide 29
Page 38
Installing the hard disks extension box Accessible drives
Figure 21: Attaching the EasyClick rails
Ê Screw the EasyClick rails onto either side of the hard disks extension box
using four M3 screws for each rail. Use the holes marked above for this purpose.
Ê Push the hard disks extension box fully into the bay until the EasyClick rails
latch in place.
Ê Connect the power cable plug P2 to the hard disks extension box. Ê Connect the SCSI cable T26139-Y3927-V1 included in the conversion kit to
the SCSI connector on the HDD extension box.
Ê Connect the I
2
C cable (T26139-Y3718-V601) with the I²C bus connector of
the HDD extension box..
2
Ê Secure the I
C cable with a green clamp.
Ê Route the SCSI cable and connect it to the SCSI connector on the 1- or
2-channel RAID controller.
Ê Attach the front cover or rack front cover, close the server, connect it to the
power outlet, and switch it on as described in the chapter “Completion” on page 59 et seqq. .
30 Options Guide U41604-Z156-1-76
Page 39

7 Controller in the PCI slots

V CAUTION!
Observe the safety instructions in the chapter “Safety notes” on page 7 et seqq. .
The system board offers six PCI slots: 2 x PCI-X (64 Bit / 66 MHz), 3 x PCI (32 Bit / 33 MHz) and 1 x PCI-Express x1 slot.
The PCI slot 2 is prepared for Zero Channel RAID (ZCR).
PCIe Slot 6
PCI Slot 5
PCI Slot 4
PCI Slot 3
PCI Slot 2
PCI Slot 1
Figure 22: Numbering of the PCI slots
PCI slot 64Bit/
32Bit
1 32 Bit 33 32-Bit PCI bus slot 2 64 Bit 66 64-Bit PCI X bus slot, prepared for ZCR 3 64 Bit 66 64-Bit PCI X bus slot 4 32 Bit 33 32-Bit PCI bus slot 5 32 Bit 33 32-Bit PCI bus slot 6 PCIe x1 bus slot
For more information see the Technical Manual of the system board D1979.
U41604-Z156-1-76 Options Guide 31
Frequency
in MHz
Description
Page 40

Installing a controller Controller in the PCI slots

7.1 Installing a controller
Ê Open the server as described in the chapter “Preparation” on page 13 et
seqq. .
3
1
2
Figure 23: Removing the rear cover
Ê Swing the locking swivel in the direction of the arrow (1). Ê Press onto the clip (2) and remove it. Ê Remove the PCI slot’s rear cover (3).
V CAUTION!
Keep the rear cover of the PCI slot for future use. If you remove the controller again and do not replace it with a new one, the rear cover must be reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire protection measures.
32 Options Guide U41604-Z156-1-76
Page 41
Controller in the PCI slots Installing a controller
a
2
1
4
Figure 24: Installing a controller
3
3
Ê Install the controller in the PCI slot and press it carefully into the associated
plug-in location on the system board (1) until it engages properly.
Ê Place the clip on the slot cover in such a way that the pin (a) fits into the hole
of the slot cover (2), and press the clip in the direction of the arrow (3) until it engages.
Ê Swing the locking swivel (4) in its locking position. Ê If required, connect the cables to the controller and other components. Ê Close the server, connect it to the power outlet, and switch it on as described
in the chapter “Completion” on page 59 et seqq. .
U41604-Z156-1-76 Options Guide 33
Page 42

PCI slot assembling Controller in the PCI slots

7.2 PCI slot assembling
Install first those controllers which request a defined slot. Then install the PCI­X controllers, then the PCI66 and at least the PCI33 controllers.
PCI bus type
1. Controller for defined slots
RemoteView service board S2 LP 33 1 1 2, 3
2. PCI-X controller
3. PCI 66 MHz controller
LSI MegaRaid Zero Channel 66 1 2 1, 3, 4, 5 LSI MegaRaid Two Channel 66 1 2, 3 1, 2, 4, 5 Emulex LP900SL 66 3 1, 3, 4 2 Qlogic QLA2200 66 3 1, 3, 4 2 Intel Pro 1000MT Dual Port 66 4 2, 3, 4, 5 Intel Pro 1000MT Server 66 4 2, 3, 4, 5
4. PCI 33 MHz controller
Promise TX150 SX4 33 1 2 Eicon Diehl Diva Bri-2M 33 2 5, 4, 3, 1 Eicon S94 33 2 5, 4, 3, 1 Madge MK4 33 4 5, 4, 3, 1 Intel Pro 1000MT Desktop 66 2 4, 5
Table 2: PCI slot assembling
QuantityPreferred
slot
Forbidden slot
34 Options Guide U41604-Z156-1-76
Page 43

8 RemoteView components

V CAUTION!
Observe the safety instructions in the chapter “Safety notes” on page 7 et seqq. .

8.1 RemoteView Service Board S2 LP

I How to configure the RSB S2 LP is described in detail in the User Guide
“RemoteView”.
The preferred mounting location for the RSB S2 is PCI slot 1. The RSB S2 LP is connected to the system board via a power and a data cable.
The RSB S2 LP kit contains an external power supply.
U41604-Z156-1-76 Options Guide 35
Page 44
RemoteView Service Board S2 LP RemoteView components
Ê Open the server as described in the chapter “Preparation” on page 13 et
seqq. .
1
2
Figure 25: Connecting cables to the RSB S2 LP
Ê Connect the power cable (1) and the data cable (2) to the RSB S2 LP. Ê Install the RSB S2 LP in PCI slot 1 as described in section “Installing a
controller” on page 32.
PCI Slot 1
BATTERY
12
Figure 26: Connecting cables to the system board
Ê Connect the data cable to the connector IPMB (1) and the power cable to the
connector RSB LP Power (2) on the system board.
36 Options Guide U41604-Z156-1-76
Page 45
RemoteView components RemoteView Service Board S2 LP
Adapter
RSB S2 LP
1
2
3
4
Externe Stromversorgung/ external power supply
Figure 27: Connecting external cables
1 connect to USB port of the server 2 connect to LAN port of the network 3 connect to VGA port of the server 4 connect to VGA port of the monitor
U41604-Z156-1-76 Options Guide 37
Page 46
RemoteView Service Board S2 LP RemoteView components
Ê Connect the external cables and the external power supply as shown in
figure 27 on page 37.
Ê Close the server, connect it to the power outlet, and switch it on as described
in the chapter “Completion” on page 59 et seqq. .
38 Options Guide U41604-Z156-1-76
Page 47

9 External SCSI interface

V CAUTION!
Observe the safety instructions in the chapter “Safety notes” on page 7 et seqq. .
If the internal hard disks are connected via a PCI RAID controller, one channel of the on-board controller can also be made available for connecting a periphe­ral cabinet SX10 via an external SCSI interface.

9.1 Installing the external SCSI interface

Ê Open the server as described in the chapter “Preparation” on page 13 et
seqq. .
Figure 28: External SCSI interface
Ê Remove the rear cover of PCI slot 7 and insert the slot cover of the external
SCSI interface in this slot as described in section “PCI slot assembling” on page 34.
Ê Attach the external SCSI interface’s connector to the SCSI channel of the
onboard SCSI controller on the system board (connector SCSI U320).
Ê Close the server, connect it to the power outlet, and switch it on as described
in the chapter “Completion” on page 59 et seqq. .
U41604-Z156-1-76 Options Guide 39
Page 48
Page 49
10 Conversion standard PS to hot-
plug PS
V CAUTION!
Observe the safety instructions in the chapter “Safety notes” on page 7 et seqq. .
The standard power supply can be replaced by a hot-plug power supply. The hot-plug power supply consists of up to two power supply modules. The upgrade kit contains only one power supply module (for power supply redundancy the second power supply module must be additionally ordered).
The upgrade kit for the hot-plug power supply consists of the following parts: – PS cage with Power backplane (incl. power cables) – locking rail – one power supply unit – dummy cover (if only one power supply module is installed, you have to
install the dummy cover in the second bay) – several screws – anti-tilt bracket
V CAUTION!
After installing the hot-plug power supply the SDR (sensor data record) data base must be updated. For this sequence you need a BIOS flash diskette. This diskette contains the newest BIOS version, the BMC firmware and the SDR data.
Ê Write a BIOS flash diskette by down loading the required data from
the software pool under
http://service.abg.fsc.net/support/softwareAssist.asp.
Ê Open the server as described in the chapter “Preparation” on page 13 et
seqq. . Ê Disconnect all power cables from the system board and the drives (see the
cabling plans in the Appendix).
U41604-Z156-1-76 Options Guide 41
Page 50
Conversion standard PS to hot-plug PS
1
Figure 29: Loosening the screws
1
Ê Remove the five screws (1) which attach the adapter plate of the standard
power supply to the housing.
2
Figure 30: Taking out the standard power supply
Ê Slide the standard power supply somewhat toward the inside (1) to detach it
from the brackets in the side cover and take it out toward the side (2).
42 Options Guide U41604-Z156-1-76
Page 51
Conversion standard PS to hot-plug PS
Figure 31: Installing the Power backplane in the PS cage
Ê Insert the Power backplane in the PS cage. Ê Push the Power backplane in direction of the arrows until the three bolts of
the PS cage engage. Ê Fasten the Power backplane with one knurled screw (see the circle).
U41604-Z156-1-76 Options Guide 43
Page 52
Conversion standard PS to hot-plug PS
Figure 32: Installing the PS cage
Ê Push the PS cage from inside into the bay. In the floorstand model the Power
backplane is positioned under the top cover, and in the rack model at the right-hand side cover (seen from front side).
V CAUTION!
Make sure that the two noses of the PS cage (see the arrows) engage in the housing. Ensure that no damage is caused to the cables.
44 Options Guide U41604-Z156-1-76
Page 53
Conversion standard PS to hot-plug PS
Figure 33: Fastening the PS cage in the housing
Ê Fasten the PS cage in the housing with one screw M3x4.5 mm (see the
circle).
U41604-Z156-1-76 Options Guide 45
Page 54
Conversion standard PS to hot-plug PS
Figure 34: Fastening the PS cage at the rear side
Ê Fix the locking rail with four screws (see the arrows) on the rear side of the
server..
Ê Fasten the PS cage with three screws M3x4.5 mm (see the circles) at the
rear side.
Ê Connect all power cables to the system board and the drives (see the cabling
plans in the Appendix).
46 Options Guide U41604-Z156-1-76
Page 55
Conversion standard PS to hot-plug PS
Figure 35: Inserting the power supply module
Ê Push the power supply module in the left side (floorstand model) or bottom
side (rack model) bay. Ê Lift the green handle somewhat upwards so that the forked levers (see the
arrows) can fit to the locking rail.
U41604-Z156-1-76 Options Guide 47
Page 56
Conversion standard PS to hot-plug PS
Figure 36: Locking the power supply module
Ê Push the green handle downward until the locking slide (see the arrow)
engages.
Ê Plug the power cord to the connector of the power supply module. Ê If you want to install a second power supply module, proceed in the same
way.
48 Options Guide U41604-Z156-1-76
Page 57
Conversion standard PS to hot-plug PS
Figure 37: Installing the dummy cover
Ê If you have not ordered a second power supply module, install the dummy
cover in the second bay:
Hook the top side of the dummy cover into the chassis, after this swivel the
dummy cover down and fasten it with one screw (see the arrow) to the
housing.
V CAUTION!
For floorstand models with hot-plug power supply the supplied anti-tilt bracket must be fitted at the rear of the server.
U41604-Z156-1-76 Options Guide 49
Page 58
Conversion standard PS to hot-plug PS
Mounting the anti-tilt bracket (only floorstand model)
Ê Attach the left-hand side cover as described in section “Closing the server”
on page 61.
1
1
Figure 38: Mounting the anti-tilt bracket
Ê Position the server on the anti-tilt bracket in the way that the rubber feet of
the server fit into the openings of the bracket (1).
50 Options Guide U41604-Z156-1-76
Page 59
Figure 39: Fastening the anti-tilt bracket
Conversion standard PS to hot-plug PS
Ê Fasten the anti-tilt bracket using the two knurled screws (1). Ê Close the server, connect it to the power outlet, and switch it on as described
in the chapter “Completion” on page 59 et seqq. .
V CAUTION!
After installing the hot-plug power supply the SDR (sensor data record) data base must be updated. For this sequence you need the BIOS flash diskette prepared before. This diskette contains the newest BIOS version, the BMC firmware and the SDR data.
I You will find the description of the indicators of the power supply module
in the Operating Manual for the PRIMERGY TX150 S3.
U41604-Z156-1-76 Options Guide 51
Page 60
Page 61
11 Converting from the floorstand
model to the rack model
V CAUTION!
Observe the safety instructions in the chapter “Safety notes” on page 7 et seqq. .
Ê Open the server and remove the front cover as described in the chapter
“Preparation” on page 13ff.
I The front cover is no longer required.
Figure 40: Removing the anti-tilt bracket
Ê If your server is equipped with an anti-tilt bracket, remove it:
Ê Remove the two knurled screws (1) and lift the server out of the anti-tilt
bracket.
U41604-Z156-1-76 Options Guide 53
Page 62
Converting from the floorstand model to the rack model
The right-hand side cover and the top cover build one part.
Figure 41: Removing the screws
Ê Remove the two screws at the rear side.
1
Figure 42: Removing the right-hand side cover
Ê Lift the hook up slightly using a screwdriver. Ê Push the right-hand side cover in the direction of the arrow. Ê Lift off the right-hand side cover.
I The right-hand side cover is no longer required.
54 Options Guide U41604-Z156-1-76
Page 63
Converting from the floorstand model to the rack model
Ê Lay the server on its right-hand side.
V CAUTION!
Get a second person to help you do this. The server can weigh up to 40 kg.
Figure 43: Removing the rubber feet
Ê Remove the two upper rubber feet (see the arrows) on the left side. Ê Remove the three screws (see the circles) and take out the rail with the two
lower rubber feet.
I The rubber feet and the rail are no longer required.
U41604-Z156-1-76 Options Guide 55
Page 64
Converting from the floorstand model to the rack model
The drive cage for the accessible drives is constructed in such a way that the accessible drives and the operating panel module can be taken out simply, tur­ned through 90° to the left, and then be reinstalled.
Ê Remove the dummy covers from the drive cage (figure 15 on page 25). Ê Unplug the cables from the system board or the accessible drives and
remove the drives from the drive cage.
Ê Pull the operating panel module forward out of its mounting location until you
can pull the the ribbon cable and the USB cable out of the operating panel module. Remove the two cables.
Ê Remove the operating panel module. Ê Turn the operating panel module through 90° to the left.
Figure 44: Installing the operating panel module
Ê Push the operating panel module halfway into the upper bay of the drive
cage.
Ê Connect the ribbon cable and the USB cable to the operating panel module. Ê Now push the operating panel module fully into the upper bay of the drive
cage.
Ê Turn the drives removed beforehand through 90° to the left. Ê Turn the dummy covers removed beforehand through 90° to the left. Ê Install the drives and empty covers in the drive cage. Ê Reestablish all connections to the drives.
56 Options Guide U41604-Z156-1-76
Page 65
Converting from the floorstand model to the rack model
Ê Attach the rack front cover, close the server, connect it to the power outlet,
and switch it on as described in the chapter “Completion” on page 59ff. To enable the rack model to be presented correctly in ServerView, proceed as
follows:
Ê Place the ServerStart CD-ROM in the drive. Ê Under the path \Tools\System Configuration start the SCU_Chassis
Model Conversion program and change the server type to "PRIMERGY
TX150S3 Rack".
U41604-Z156-1-76 Options Guide 57
Page 66
Page 67

12 Completion

V CAUTION!
Observe the safety instructions in the chapter “Safety notes” on page 7 et seqq. .

12.1 Floorstand model

12.1.1 Attaching the hard disk cover
After you have installed further SATA hard disk drives, reattach the hard disk cover.
1
Figure 45: Attaching the hard disk cover
Ê Push the drive cover up as far as possible (1). Ê Reinsert the hard disk cover (2 + 3). Ê Insert the key. Ê Lock the server. Ê Press the on/off key to start up the server.
U41604-Z156-1-76 Options Guide 59
2
3
Page 68
Floorstand model Completion
12.1.2 Attaching the front cover
After you have installed further accessible drives, reattach the front cover.
2
1
3
Figure 46: Attaching the front cover
Ê Press the two hooks (1) on the right side in the recesses of the housing. Ê Press the front cover onto the housing (2) until the three tabs on the left side
engage (3).
Ê Attach the hard disk cover as shown in figure 45 on page 59.
60 Options Guide U41604-Z156-1-76
Page 69
Completion Floorstand model
12.1.3 Closing the server
1
2
Figure 47: Attaching the left-hand side cover
Ê Position the left-hand side cover in such a way that it protrudes approxiate
2 cm at the rear (1). Shut the left-hand side cover. Ê Push the left-hand side cover all the way forward (2).
1
Figure 48: Fastening the left-hand side cover
Ê Fasten the left-hand side cover with two screws (1). Ê Insert the key. Ê Lock the server. Ê Connect all power plugs to the power outlets. Ê Press the on/off key to start up the server.
U41604-Z156-1-76 Options Guide 61
Page 70

Rack model Completion

12.2 Rack model
12.2.1 Attaching the rack front cover
Reattach the rack front cover after implementing the following extensions: – Installation of further accessible drives – Conversion of the floorstand model to a rack model
3
2
1
Figure 49: Attaching the plastic front cover
Ê Press the two hooks (1) on the bottom side in the recesses of the housing. Ê Press the plastic front cover onto the housing (2) until the three tabs on the
top side engage (3).
62 Options Guide U41604-Z156-1-76
Page 71
Completion Rack model
2
1
2
Figure 50: Attaching the rack front cover
Ê Attach the rack front cover from the front (1). Ê Attach the rack front cover using two screws on each side (2).
U41604-Z156-1-76 Options Guide 63
Page 72
Rack model Completion
12.2.2 Closing the server
1
2
2
3
Figure 51: Attaching the top cover
Ê Position the top cover in such a way that it protrudes approxiate 2 cm at the
rear (1).
Ê Push the top cover all the way forward (2). Ê Fasten the top cover with two screws (3).
64 Options Guide U41604-Z156-1-76
Page 73
Completion Rack model
If you have not removed the server from the rack cabinet, please skip this page.
V CAUTION!
At least two people are required to install the server in the rack cabinet. Do not use the handles on the rack front cover to lift the server into the rack.
Ê Lower the server from above onto the extended telescopic rails.
2
Figure 52: Installing the server in a rack cabinet
Ê Screw the telescopic rails onto the left-hand side (one screw) and right-hand
side (two screws) of the server. Ê Reconnect all the cables you disconnected beforehand on the rear of the
server. Ê Press in the locking spring on both sides and push the server as far as it will
go into the rack.
U41604-Z156-1-76 Options Guide 65
Page 74
Rack model Completion
1
Figure 53: Fastening the server in the rack cabinet
Ê Fasten the server in the rack using the four knurled screws (1). Ê Connect all power plugs to the power outlets. Ê Press the on/off key to start up the server.
66 Options Guide U41604-Z156-1-76
Page 75

13 Appendix

13.1 Cabling

I The Pn numbers of the power cables are identical for the standard and
the redundant power supply. You will not find a special drawing for the power supply cabling.
13.1.1 SCSI version
1-channel SCSI version with onboard SCSI controller
In the basic version the tape drives and the four internal hard disk drives are connected to the onboard SCSI controller via one SCSI cable.
1-channel SCSI version with additional SCSI RAID controller
A SCSI RAID controller is installed into a PCI slot and connected with the four internal hard disk drives.
In this case, the connection to the onboard SCSI controller must be changed to the RAID controller. The accessible drives must be unplugged from this SCSI cable.
After this the accessible drives can be connected to the onboard SCSI controller via an additional SCSI cable.
Supplementary channels of the RAID controller are available for external hard disk drive systems.
U41604-Z156-1-76 Options Guide 67
Page 76
Cabling Appendix
SCSI
device
SCSI
device
P3
P5
Floppy
Floppy
IDTEMP
Y1248-V8
1" HDD
SCSI HD ID3
SCSI HD ID2
X6
P6
SCSI HD ID1
X7
SCSI HD ID0
X5
SCSI backplane
1-channel
Intrusion sw.
Intrusion sw.
CD/DVD
P4
Operating panel
USB
Y3904-V1
Y3912-V1
P2
Y1737-V111
P8
P1
Power supply
P9
Figure 54: Cabling 1-channel SCSI version with onboard SCSI controller
Y3736-V1
Y3785-V301
Y3718-V508
System
fan
Power
SCSI
IDE/FD
Y3728-V1
Legend:
Data
Cable prefix: T26139-
68 Options Guide U41604-Z156-1-76
Page 77
Appendix Cabling
P3
Floppy
SCSI
device
Floppy
P5
IDTEMP
free
Y1248-V8
P9
1" HDD
SCSI HD ID3
SCSI HD ID2
X6
P6
Intrusion sw.
Y3736-V1
Y3859-V11
SCS HD ID1
X7
Intrusion sw.
Y3718-V508
SCSI HD ID0
X5
Y3785-V301
Y2361-V102
SCSI backplane
1-channel
SCSI RAID
controller
SCSI
device
CD/DVD
Operating panel
P4
USB
Y3904-V1
Y3912-V1
P2
Y1737-V111
P8
P1
System
fan
Power
SCSI
IDE/FD
Power supply
Legend:
Y3728-V1
Data
Cable prefix: T26139-
Figure 55: Cabling 1-channel SCSI version with additional SCSI RAID controller
U41604-Z156-1-76 Options Guide 69
Page 78
Cabling Appendix
Hard disk
extension
CD/DVD
Operating panel
P4
USB
Y3904-V1
Y3912-V1
Y1737-V111
P8
box
P2
P3
Y3927-V1
RAID
P1
Floppy
Floppy
P5
IDTEMP
Y1248-V8
controller
P9
1" HDD
SCSI HD ID3
SCSI HD ID2
X6
P6
SCSI HD ID1
X7
Y3785-V301
Y3718-V508
SCSI HD ID0
X5
SCSI backplane
1-channel
Intrusion sw.
Intrusion sw.
Y3736-V1
System
fan
Power
SCSI
IDE/FD
Power supply
Y3728-V1
Data
Legend:
Figure 56: Cabling hard disk extension box
70 Options Guide U41604-Z156-1-76
Cable prefix: T26139-
Page 79
Appendix Cabling
13.1.2 SATA version
SCSI
SCSI
CD/DVD
P2
P4
Operating panel
USB
Y3904-V1
Y3912-V1
device
device
P3
P5
Floppy
Floppy
IDTEMP
1" HDD
SATA HD 3
SATA HD 2
SATA HD 1
SATA HD 0
X6
X4
X9
X8
P6
free
X2
X10
SATA backplane
X11
Y1737-V111
P8
P1
Power supply
Y1248-V8
P9
Figure 57: Cabling with additional SATA controller
4 x Y3928-V101
Intrusion sw.
Intrusion sw.
4 2 1 3
SATA controller
Y3895-V11
SCSI RAID
controller
Y3736-V1
Y3718-V508
Y2361-V102
System
fan
Power
SCSI
IDE/FD
Data
Legend:
Y3728-V1
Cable prefix: T26139-
U41604-Z156-1-76 Options Guide 71
Page 80
Page 81

Abbreviations

AC
Alternating Current
ANSI
American National Standard Institut
ASR&R
Automatic Server Reconfiguration and Restart
BIOS
Basic Input-Output System
BMC
Baseboard Management Controller
CC
Cache Coherency
CD
Compact Disk
CD-ROM
Compact Disk-Read Only Memory
CHS
Cylinder Head Sector
CMOS
Complementary Metal Oxide Semiconductor
COM
Communication
CPU
Central Processing Unit
DC
Direct Current
DIMM
Dual Inline Memory Module
U41604-Z156-1-76 Options Guide 73
Page 82
Abbreviations
DIP
Dual Inline Package
DMA
Direct Memory Access
DMI
Desktop Management Interface
ECC
Errror Checking and Correcting
ECP
Extended Capabilities Port
EEPROM
Electrically Erasable Programmable Read-Only Memory
EMC
ElectroMagnetic Compatibility)
EMP
Emergency Management Port
EPP
Enhanced Parallel Port
ESD
ElectroStatic Discharge
FPC
Front Panel Controller
FRU
Field Replaceable Unit
FSB
Front Side Bus
GAM
Global Array Manager
GUI
Graphical User Interface
74 Options Guide U41604-Z156-1-76
Page 83
HDD
Hard Disk Drive
HSC
Hot-Swap Controller
I²C
Inter-Integrated Circuit
I/O
Input/Output
ICM
Intelligent Chassis Management
ID
Identification
IDE
Intergrated Drive Electronics
IOOP
Intetelligent Organization of PCI
Abbreviations
IRQ
Interrupt Request Line
LAN
Local Area Network
LBA
Logical Block Address
LCD
Liquid Crystal Display
LUN
Logical Unit Number
LV D
Low-Voltage Differential SCSI
MMF
Multi Mode Faser
U41604-Z156-1-76 Options Guide 75
Page 84
Abbreviations
MRL
Manually Retention Latch
NMI
Non Maskable Interrupt
NVRAM
Non Volatile Random Access Memory
OS
Operating System
PCI
Peripheral Component Interconnect
PDA
Prefailure Detection and Analysing
POST
Power ON Self Test
RAID
Redundant Arrays of Independent Disks
RAM
Random Access Memory
ROM
Read-Only Memory
RSB
Remote Service Board
RTC
Real Time Clock
RTDS
Remote Test- und Diagnose-System
SAF-TE
SCSI Accessed Fault-Tolerance Enclosures
SBE
Single Bit Error
76 Options Guide U41604-Z156-1-76
Page 85
SCA
Single Connector Attachment
SCSI
Small Computer System Interface
SDDC
Single Device Data Correction
SDR
Sensor Data Record
SDRAM
Synchronous Dynamic Random Access Memory
SEL
System Event Log
SMI
System Management Interrupt
SSU
System Setup Utility
Abbreviations
SVGA
Super Video Graphics Adapter
USB
Universal Serial Bus
VGA
Video Graphics Adapter
U41604-Z156-1-76 Options Guide 77
Page 86
Page 87

Related publications

PRIMERGY manuals are available as PDF file on the ServerBooks CD. The ServerBooks CD is part of the ServerView Suite delivered with each server system.
The actual version of the necessary manuals can be downloaded free of charge from the Internet. The overview page showing the online documentation available in the Internet can be found via the URL: http://manuals.fujitsu-siemens.com (choose: intel based servers/PRIMERGY ServerBooks).
[1] Safety [2] Warranty [3] PRIMECENTER Rack
Technical Manual
[4] DataCenter Rack
Technical Manual
[5] 19 inch rack
Technical Manual
[6] PRIMERGY ServerView Suite
ServerStart
[7] ServerView
Server Management
User Manual
[8] ServerView Extension
ServerView Extension for HP OpenView NNM
[9] ServerView/Plus for Tivoli
[10] RemoteView
User Manual
[11] PRIMERGY TX150 S3
Operating Manual
[12] System Board D1979
Technical Manual
[13] BIOS-Setup
Reference Manual
U41604-Z156-1-76 Options Guide 79
Page 88
Related Publications
[14] Integrated Mirroring
User’s Guide
[15] Global Array Manager Client Software
User’s Guide
[16] Configurator
For partners and distributors only: http://extranet.fujitsu-siemens.com/cafe/products/primergy
80 Options Guide U41604-Z156-1-76
Page 89

Index

A
accessible drives 3, 25
C
controller 3, 32 conversion of floorstand module to
rack model 4 conversion standard power supply to
hot-plug power supply 4 Conversion standard PS to hot-plug
PS 41
E
ESD (devices sensitive to electrostatic
discharge) 12 external SCSI interface 3, 39
F
floorstand to rack model
conversion 53 front cover 14, 60
H
hard disk cover 15, 59 hard disks extension box 3, 29
I
information material 2
R
rack front cover 19, 62 RemoteView Service Board S2 LP 3,
35
S
SATA hard disk drives 2
T
target group 1
L
light-emitting diode (LED) 11 lithium battery 10
M
main memory 2, 21 meaning
of the symbols 4
N
notational conventions 4 note about the laser 11
U41604-Z156-1-76 Options Guide 81
Page 90
Page 91
Fujitsu Siemens Computers GmbH User Documentation 81730 München Germany
Fax: (++49) 700 / 372 00000
email: manuals@fujitsu-siemens.com http://manuals.fujitsu-siemens.com
Submitted by
Comments
Suggestions
Corrections
Comments on PRIMERGY TX150 S3
Server System
U41604-Z156-1-76
Page 92
Page 93
Fujitsu Siemens Computers GmbH User Documentation 81730 München Germany
Fax: (++49) 700 / 372 00000
email: manuals@fujitsu-siemens.com http://manuals.fujitsu-siemens.com
Submitted by
Comments
Suggestions
Corrections
Comments on PRIMERGY TX150 S3
Server System
U41604-Z156-1-76
Page 94
Page 95
Information on this document
On April 1, 2009, Fujitsu became the sole owner of Fujitsu Siemens Compu­ters. This new subsidiary of Fujitsu has been renamed Fujitsu Technology So­lutions.
This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed.
Please note that all company references and copyrights in this document have been legally transferred to Fujitsu Technology Solutions.
Contact and support addresses will now be offered by Fujitsu Technology So­lutions and have the format …@ts.fujitsu.com.
The Internet pages of Fujitsu Technology Solutions are available at
http://ts.fujitsu.com/...
and the user documentation at http://manuals.ts.fujitsu.com. Copyright Fujitsu Technology Solutions, 2009
Hinweise zum vorliegenden Dokument
Zum 1. April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu übergegangen. Diese neue Tochtergesellschaft von Fujitsu trägt seit­dem den Namen Fujitsu Technology Solutions.
Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor längerer Zeit freigegebene oder nicht mehr im Vertrieb befindliche Produktversion.
Bitte beachten Sie, dass alle Firmenbezüge und Copyrights im vorliegenden Dokument rechtlich auf Fujitsu Technology Solutions übergegangen sind.
Kontakt- und Supportadressen werden nun von Fujitsu Technology Solutions angeboten und haben die Form …@ts.fujitsu.com.
Die Internetseiten von Fujitsu Technology Solutions finden Sie unter
http://de.ts.fujitsu.com/..., und unter http://manuals.ts.fujitsu.com finden Sie die