Susanne Däschlein
Fujitsu Siemens Computers GmbH München
81730 München
e-mail: email: manuals@fujitsu-siemens.com
Tel.: (089) 61001155
Fax: (++49) 700 / 372 00000
U41604-Z156-1-76
Sprachen: En
Edition January 2005
Page 2
Comments… Suggestions… Corrections…
The User Documentation Department would like to
know your opinion of this manual. Your feedback helps
us optimize our documentation to suit your individual
needs.
Fax forms for sending us your comments are included in
the back of the manual.
There you will also find the addresses of the relevant
User Documentation Department.
Certified documentation
according to DIN EN ISO 9001:2000
To ensure a consistently high quality standard and
user-friendliness, this documentation was created to
meet the regulations of a quality management system
which complies with the requirements of the standard
DIN EN ISO 9001:2000.
cognitas. Gesellschaft für Technik-Dokumentation mbH
www.cognitas.de
The PRIMERGY TX150 S3 Server is an Intel-based server for medium-sized
networks and large companies. The server is suitable for use as a file server as
well as an application, information, or Internet server. It is available as a floorstand or rack model. The floorstand model can be converted to a rack model
using an optional conversion kit.
1.1Overview of the documentation
I PRIMERGY manuals are available in PDF format on the ServerBooks CD
which is supplied in the ServerView Suite package for every server
system.
These PDF files can also be downloaded free of charge from the
Internet: at http://manuals.fujitsu-siemens.com you will find an overview
page with the online documentation available on the Internet. You can go
to the PRIMERGY Server documentation by clicking on “intel based
Servers”.
Concept and target groups
This Options Guide shows you how you can expand and upgrade the server.
I The Operating Manual for the server describes how you install/remove
the hot-plug components.
The activities described in this manual may only be performed by technicians,
service personnel or technical specialists.
Additional documentation about the server
The PRIMERGY TX150 S3 documentation comprises the following additional
manuals:
– The “Security” manual (printed copy always supplied with the server, and
available as a PDF file on the ServerBooks CD supplied)
– The “Guarantee” manual (printed copy always supplied with the server, and
available as a PDF file on the ServerBooks CD supplied)
– The Operating Manual for the PRIMERGY TX150 S3 (PDF available on the
ServerBooks CD supplied)
U41604-Z156-1-76Options Guide1
Page 10
Extensions and conversionsIntroduction
– The Technical Manual for the system board D1979 (PDF available on the
ServerBooks CD supplied)
– The “BIOS Setup” manual (PDF available on the ServerBooks CD supplied)
– The “PRIMERGY ServerView Suite - ServerStart” manual (printed copy
always supplied with the server, and available as PDF file on the ServerBooks
CD supplied)
– The “Global Array Manager Client Software User’s Guide” (PDF available on
the ServerBooks CD supplied)
– The “Integrated Mirroring User’s Guide” (PDF available on the ServerBooks
CD supplied)
I You can order a supplementary ServerBooks CD by sending an e-mail to
the following address, quoting your server data:
Reklamat-PC-LOG@fujitsu-siemens.com
Further sources of information:
– Technical Manual on the relevant rack
– Manual on the monitor
– Manual on ServerView Server Management
– Manual on the RemoteView Remote Test and Diagnostics System
– Documentation on boards and drives
– Documentation on your operating system
– Information files on your operating system
(see also “Related publications” on page 79)
1.2Extensions and conversions
Extension of the main memory
The four slots for the main memory are suitable for DDR1 333/400 MHz (unbuffered) SDRAM memory modules. The organization in two memory banks, 1 and
2, permits rapid memory access with two-way interleaving.
If the memory modules are populated in pairs, each pair must consist of
identical memory modules (2-way interleaved mode).
Additional SATA hard disk drives
In the SATA version four bays are available for SATA hard disk drives.
2Options Guide U41604-Z156-1-76
Page 11
IntroductionExtensions and conversions
Additional accessible drives
Three 5.25-inch bays are available for accessible drives. The top side bay is
already occupied by a CD/DVD ROM drive.
Hard disks extension box
In the SCSI version the two lower 5.25-inch bays for accessible drives can be
used to integrate a hard disks extension box.
The hard disks extension box enables up to three additional HDD modules to be
integrated. Each HDD module can accommodate a SCSI hard disk drive with
an SCA (Single Connector Attachment) interface and a height of at most 1 inch.
The connection to the SCSI backplane is made without cables via the SCA
interface. This makes it simple to plug in or pull out the HDD modules. If the
server has a RAID controller and the corresponding RAID configuration,
defective HDD modules can also be replaced while the system is operating.
Additional controllers in the PCI slots
The system board offers six PCI slots: 2 x PCI-X (64 Bit / 66 MHz), 3 x PCI (32
Bit / 33 MHz) and 1 x PCI-Express x1 slot.
The PCI slot 2 is prepared for Zero Channel RAID (ZCR).
RemoteView Service Board S2 LP
The RemoteView Service Board S2 LP (RSB S2 LP) is a PCI board with a
completely independent system, i.e. it has its own operating system with Web
server and SNMP agents and can optionally be equipped with an external
power supply. The RSB S2 LP permits remote diagnosis for system analysis,
remote system configuration and remote restart even in the event of operating
system failure or hardware faults. It has its own LAN connection and its own
COM port. All the functions of the RSB S2 LP are thus available either via a LAN
or modem.
External SCSI interface
If the internal hard disks are connected via a PCI RAID controller, one channel
of the on-board controller can also be made available for connecting a
peripheral cabinet SX10 via an external SCSI interface.
U41604-Z156-1-76Options Guide3
Page 12
Notational conventionsIntroduction
Conversion standard power supply to hot-plug power supply
The standard power supply can be replaced by a hot-plug power supply. The
hot-plug power supply consists of two power supply modules.
If one power supply module fails, the other power supply module guarantees the
unrestricted operation and the defective power supply module can be replaced
be replaced while the system is operating (hot-plug).
Conversion of the floorstand model to a rack model
The floorstand model can optionally be converted so that the server can be
integrated into the common rack systems.
1.3Notational conventions
The following notational conventions are used in this manual:
Text in italicsindicates commands, menu items or software programs.
„Quotation marks“indicate names of chapters and terms that are being
emphasized.
Êdescribes activities that must be performed in the order
shown.
V CAUTION!pay particular attention to texts marked with this symbol.
Failure to observe this warning may endanger your life,
destroy the system or lead to the loss of data.
Iindicates additional information, notes and tips.
Table 1: Notational conventions
4Options Guide U41604-Z156-1-76
Page 13
2Procedure
V CAUTION!
The actions described in these instructions should only be performed by
technicians, service personnel or technical specialists. Equipment
repairs should only be performed by authorized, qualified staff. Any
unauthorized opening and improper repairs could expose the user to
risks (electric shock, energy hazards, fire hazards) and could also
damage the equipment. Please note that any unauthorized opening of
the device will result in the invalidation of the warranty and exclusion from
all liability.
Ê First of all please familiarize yourself with the safety instructions in the
section chapter “Safety notes” on page 7 et seqq. .
Ê Ensure that all required manuals (see “Additional documentation about the
server” on page 1) are available, printing out the PDF files if necessary. You
will definitely need the Operating Manual for the server and the Technical
Manual for the system board.
Ê Shut down the server correctly, switch it off, pull out the power plug(s), and
open the server as described in the chapter “Preparation” on page 13 et
seqq. .
Ê Extend or upgrade your server as described in the relevant chapter.
I The Operating Manual for the server describes how you
install/remove the hot-plug components.
I Procedures which are identical for the floorstand and rack models are
only described for the floorstand model.
Ê Close the server, connect it to the power outlet, and switch it on as described
in the chapter “Completion” on page 59 et seqq. .
Ê Start the operating system and, if necessary, configure it as required (see
the Operating Manual).
U41604-Z156-1-76Options Guide5
Page 14
Page 15
3Safety notes
I The following safety notes are also provided in the “Safety” manual.
This device complies with the relevant safety regulations for data processing
equipment.
If you have any questions about where you can set up the device, contact your
sales outlet or our customer service team.
V CAUTION!
The actions described in these instructions should only be performed by
technicians, service personnel or technical specialists. Equipment
repairs should only be performed by authorized, qualified staff. Any
unauthorized openings and improper repairs could expose the user to
risks (electric shock, energy hazards, fire hazards) and could also
damage the equipment. Please note that any unauthorized openings of
the device will result in the invalidation of the warranty and exclusion from
all liability.
Before operating the device
V CAUTION!
● During installation and before operating the device, observe the
instructions on environmental conditions for your device.
● If the device is brought in from a cold environment, condensation may
form both inside and on the outside of the machine.
Wait until the device has acclimatized to room temperature and is
absolutely dry before starting it up. Material damage may be caused
to the device if this requirement is not observed.
● Transport the device only in the original packaging or in packaging
that protects it from knocks and jolts.
U41604-Z156-1-76Options Guide7
Page 16
Safety notes
Installation and operation
V CAUTION!
● If the rack model is integrated in an installation that receives power
from an industrial (public) power supply network with the IEC309
connector, the (public) power supply protection must comply with the
requirements for the non-industrial (public) power supply networks for
the type A connector.
● The server automatically sets itself to a voltage in the range of
100 V to 240 V. Make sure that your local voltage is within this range.
● This device has a specially approved power cable and must only be
connected to a grounded insulated socket.
● Ensure that the power socket on the device or the grounded wall
outlet is freely accessible.
● The ON/OFF button does not disconnect the device from the mains
voltage. To disconnect the line voltage completely, remove the power
plug(s) from the grounded insulated socket(s).
V CAUTION!
● Always connect the device and the attached peripherals to the same
power circuit. Otherwise you run the risk of losing data if, for example,
the central processing unit is still running but the peripheral device
(e.g. storage subsystem) has failed during a power outage.
● Data cables to peripheral devices must be adequately shielded.
● To the LAN wiring the requirements apply in accordance with the
standards EN 50173 and EN 50174-1/2. As minimum requirement
the use of a protected LAN line of category 5 for 10/100 MBps
Ethernet, and/or of category 5e for Gigabit Ethernet is considered.
The requirements of the specification ISO/IEC 11801 are to be
considered.
● Route the cables in such a way that they do not form a potential
hazard (make sure no-one can trip over them) and that they cannot
be damaged. When connecting up a device, refer to the relevant
notes in this manual.
● Never connect or disconnect data transmission lines during a storm
(lightning hazard).
8Options Guide U41604-Z156-1-76
Page 17
● In emergencies (e.g. damaged casing, controls or cables, penetration
of liquids or foreign matter), switch off the device immediately, remove
the power plug and contact your sales outlet or customer service
team.
● Proper operation of the device (in accordance with IEC 60950/
EN 60950) is only ensured if the casing is completely assembled and
the rear covers for the installation openings have been put in place
(electric shock, cooling, fire protection, interference suppression).
● Only install system expansions that satisfy the requirements and
rules governing safety and electromagnetic compatibility and relating
to telecommunications terminal equipment. If you install other expansions, you may damage the system or violate the safety regulations
and regulations governing RFI suppression. Information on which
system expansions are suitable can be obtained from the customer
service centre or your sales outlet.
V CAUTION!
● The components or parts marked with a warning label (e.g. lightning
symbol) may only be opened, removed or exchanged by authorized,
qualified personnel. The hot-plug power supply units are exceptions
to this rule.
Safety notes
● The warranty expires if the device is damaged during the installation
or replacement of system expansions.
● You may only set those resolutions and refresh rates specified in the
„Technical data“ section of the monitor description. Otherwise, you
may damage your monitor. If you are in any doubt, contact your sales
outlet or customer service centre.
U41604-Z156-1-76Options Guide9
Page 18
Safety notes
Batteries
V CAUTION!
● Incorrect replacement of batteries may lead to a risk of explosion. The
batteries may only be replaced with identical batteries or with a type
recommended by the manufacturer (see the technical manual for the
system board under “Related publications” on page 79).
● Do not throw batteries into the trash can. They must be disposed of
in accordance with local regulations concerning special waste.
● The battery must be disposed of in accordance with local regulations
concerning special waste.
● Replace the lithium battery on the system board in accordance with
the instructions in the technical manual for the system board (see
“Related publications” on page 79).
● All batteries containing pollutants are marked with a symbol (a
crossed-out garbage can). In addition, the marking is provided with
the chemical symbol of the heavy metal decisive for the classification
as a pollutant:
Cd Cadmium
Hg Mercury
Pb Lead
10Options Guide U41604-Z156-1-76
Page 19
Safety notes
Notes on handling CDs and CD-/DVD-ROM drives
V CAUTION!
● Use only CDs in proper condition in the CD-/DVD-ROM drive of your
server to prevent data loss, damage to the device and injuries.
● Therefore, check each CD for damage, cracks, breakage etc. before
inserting it in the drive.
Please note that any additional labels applied may change the
mechanical properties of a CD and cause imbalance.
Damaged and imbalanced CDs can break at high drive speeds (data
loss).
Under certain conditions sharp-edged pieces of broken CDs can
penetrate the cover of the drive (damage to the device) and be thrown
out of the device (danger of injury, particularly on uncovered body
parts such as the face or neck).
I You protect the CD-/DVD-ROM drive and prevent mechanical damage,
as well as premature wearing of the CDs, by observing the following
suggestions:
– Only insert the CDs in the drive when needed and remove them after
use.
– Store the CDs in suitable sleeves.
– Protect the CDs from exposure to heat and direct sunlight.
Note about the laser
The CD-/DVD-ROM drive
is classified for
laser class 1according to IEC 60825-1.
V CAUTION!
The CD-/DVD-ROM drive contains a laser diode (LED). Sometimes the
LED produces a stronger laser beam than laser class 1. Direct view into
this laser beam is dangerous.
Never remove parts of the CD-/DVD-ROM drive assembly!
U41604-Z156-1-76Options Guide11
Page 20
Safety notes
Modules with electrostatic-sensitive components:
Systems and components that might be damaged by electrostatic discharge
(ESD) are marked with the following label:
Figure 1: ESD label
When you handle components fitted with ESDs, you must observe the following
points under all circumstances:
● Remove the power plug from the power socket before inserting or removing
components containing ESDs.
● You must always discharge yourself of static charges (e.g. by touching a
grounded object) before working.
● The equipment and tools you use must be free of static charges.
● Only touch the components at the positions highlighted in green (touch
points).
● Do not touch any exposed pins or conductors on a component.
● Use a grounding cable designed for this purpose to connect yourself to the
system unit as you install components.
● Place all components on a static-safe base.
I You will find a detailed description for handling ESD components in the
relevant European or international standards (DIN EN 61340-5-1,
ANSI/ESD S20.20).
12Options Guide U41604-Z156-1-76
Page 21
4Preparation
V CAUTION!
Observe the safety instructions in the chapter “Safety notes” on page 7
et seqq. .
4.1Floorstand model
4.1.1Opening the server
Ê Terminate all applications and shut down the server correctly.
Ê If your operating system has not switched off the sever, press the on/off
switch.
Ê Pull all power connectors out of the power outlets.
Ê If required, remove the lock on the side cover.
1
4
3
2
Figure 2: Loosening the screws
Ê Unlock the server (1).
Ê Loosen the two screws at the rear side (2).
Ê Push back the left-hand side cover approxiate 2 cm (3).
Ê Remove the left-hand side cover (4).
U41604-Z156-1-76Options Guide13
Page 22
Floorstand modelPreparation
4.1.2Removing the front cover
Remove the front cover when making the following extensions and upgrades:
– Installing further accessible drives
– Upgrading the floorstand model to a rack model
Ê Remove the hard disk cover as shown in figure 5 on page 15.
2
1
Figure 3: Removing the front cover
Ê Disengage the three tabs (1) on the left side one after the other and rotate
the front cover outward (2) about 2 cm.
2
1
Figure 4: Removing the front cover
Ê Press the two hooks (1) on the right side inward and pull out the front cover
frontward (2).
14Options Guide U41604-Z156-1-76
Page 23
PreparationFloorstand model
4.1.3Removing the hard disk cover
Remove the hard disk cover when making the following extensions and
upgrades:
– Installing further SATA hard disk drives
Ê Terminate all applications and shut down the server correctly.
Ê If your operating system has not switched off the sever, press the on/off
switch.
2
1
4
3
Figure 5: Removing the hard disk cover
Ê Unlock the server (1) and remove the key.
Ê Push the drive cover up as far as possible (2).
Ê Remove the hard disk cover (3 + 4).
U41604-Z156-1-76Options Guide15
Page 24
Rack modelPreparation
4.2Rack model
Ê Terminate all applications and shut down the server correctly.
Ê If your operating system has not switched off the server, press the on/off
button.
Ê Pull all power connectors out of the power outlets.
4.2.1Opening the server
1
2
Figure 6: Loosening the knurled screws
Ê Loosen the four knurled screws (1) and pull the server as far as possible out
of the rack (2).
16Options Guide U41604-Z156-1-76
Page 25
PreparationRack model
2
1
Figure 7: Loosening the locking spring
Ê Press in the locking spring (1) on both sides and carefully pull the server
outward (2).
2
Figure 8: Removing the server from the rack cabinet
Ê Disconnect all cables on the rear of the server.
Ê Remove the telescopic rails on the left and right side (three screws).
U41604-Z156-1-76Options Guide17
Page 26
Rack modelPreparation
V CAUTION!
At least two people are needed to lift the server out of the rack cabinet.
Ê Lift the server out of the rails and place it on a table, for example.
3
1
Figure 9: Loosening the screws
Ê Unlock the top cover by removing the two screws at the rear side (1).
Ê Push back the top cover approxiate 2 cm (2).
Ê Remove the top cover (3).
2
2
18Options Guide U41604-Z156-1-76
Page 27
PreparationRack model
4.2.2Removing the rack front cover
Remove the rack front cover when carrying out the following extension:
– Installing further accessible drives
1
2
1
Figure 10: Removing the rack front cover
Ê Remove two screws on either side (1).
Ê Remove the rack front cover to the front (2).
1
2
4
3
Figure 11: Removing the plastic front cover
Ê Disengage the three tabs (1) on the top side one after the other and pull out
the plastic front cover frontward (2) about 2 cm.
Ê Press the two hooks (3) on the bottom side downward and pull out the plastic
front cover frontward (4).
U41604-Z156-1-76Options Guide19
Page 28
Page 29
5Main memory
V CAUTION!
Observe the safety instructions in the chapter “Safety notes” on page 7
et seqq. .
The system board supports up to 4 Gbytes of main memory. Four slots (2 slots
form a memory bank) are provided for the main memory. Each memory bank
can be equipped with 256 Mbyte, 512 Mbyte or 1 Gbyte unbuffered DDR I
memory modules.
5.1Equipping rules
DIMM 1A
DIMM 2A
DIMM 1B
DIMM 2B
Figure 12: Structure of the main memory in memory banks and memory modules
– Each memory bank is equipped with two memory modules with the same
capacity. Memory access takes place in 2-way interleaved mode.
– The memory module capacity can differ for the various memory banks: e.g.
memory bank 2A/2B can be equipped with two 512 Mbyte memory modules,
and memory bank 1A/1B with two 1 Gbyte memory modules.
U41604-Z156-1-76Options Guide21
Page 30
Extending/replacing the main memoryMain memory
The table below shows the order in which the memory banks must be equipped:
Ê Open the server as described in the chapter “Preparation” on page 13 et
seqq. .
1
Figure 13: Removing a memory module
2
1
Ê Press the holders on either side of the mounting location concerned outward
(1).
Ê If the mounting location was already equipped: pull the memory module out
of the mounting location (2).
22Options Guide U41604-Z156-1-76
Page 31
Main memoryExtending/replacing the main memory
2
2
Figure 14: Inserting a memory module
Ê Press the holders on either side of the mounting location concerned
outward.
Ê Insert the memory module in the mounting location (1) until the holders at
the sides engage (2).
Ê Close the server, connect it to the power outlet, and switch it on as described
in the chapter “Completion” on page 59 et seqq. .
U41604-Z156-1-76Options Guide23
Page 32
Page 33
6Accessible drives
V CAUTION!
Observe the safety instructions in the chapter “Safety notes” on page 7
et seqq. .
Three 5.25-inch bays are available for accessible drives. The top side bay is
already equipped with a CD/DVD-ROM drive. The two lower bays can also be
used to install a hard disks extension box.
6.1Installing an accessible 5.25-inch drive
The 5.25-inch drives available are magnetic tape drives, CD/DVD-ROM drives
and CD/DVD-ROM burners. These drives can be installed in the two free 5.25inch bays.
Ê Open the server and remove the front cover or rack front cover as described
in the chapter “Preparation” on page 13 et seqq. .
I New 5.25-inch drives are supplied without EasyClick rails. Before
installing a new drive you must therefore remove the EasyClick rails from
the dummy cover and mount the EasyClick rails on the new drive.
1
1
2
1
Figure 15: Removing the dummy cover
Ê Press the two metal tongues of the EasyClick rails inward (1) until the locking
mechanism is released.
Ê Remove the dummy cover from the bay (2).
U41604-Z156-1-76Options Guide25
Page 34
Installing an accessible 5.25-inch driveAccessible drives
Ê Remove the EasyClick rails from the dummy cover by removing the four
screws on each side.
I Note that there are two M3 screws and two UNC screws on each side.
V CAUTION!
Keep the dummy cover for future use. If you remove the accessible drive
again and do not replace it with a new one, the dummy cover must be
reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire protection measures.
1
1
Figure 16: Attaching the EasyClick rails - DVD-ROM burner
Ê Screw the EasyClick rails onto either side of the new 5.25-inch drive using
two M3x4.5mm screws (1).
Use the first hole in each upper row of holes as shown in the figure.
I Keep the remaining screws for future use. The different drives are
fastened using different screws. Starting on the next page, you will
find figures which show the attaching of the EasyClick rails for
magnetic tape drives.
Ê Push the new drive about halfway into the bay.
Ê Connect the data cable to the accessible drive (see the cabling plans in the
Appendix).
Ê Connect the power cable to the accessible drive (see the cabling plans in the
Appendix).
Ê Push the drive fully into the bay until the EasyClick rails latch in place.
26Options Guide U41604-Z156-1-76
Page 35
Accessible drivesInstalling an accessible 5.25-inch drive
Ê Attach the front cover or rack front cover, close the server, connect it to the
power outlet, and switch it on as described in the chapter “Completion” on
page 59 et seqq. .
You will find in the following figures which holes and screws should be used for
the magnetic tape dives.
Figure 17: Attaching the EasyClick rails - magnetic tape drive LTO Ultrium 1HH
Figure 18: Attaching the EasyClick rails - magnetic tape drive LTO Ultrium 2FH
U41604-Z156-1-76Options Guide27
Page 36
Installing an accessible 5.25-inch driveAccessible drives
Figure 19: Attaching the EasyClick rails - magnetic tape drive VXA-2
Figure 20: Attaching the EasyClick rails - magnetic tape drive DDS Gen5
28Options Guide U41604-Z156-1-76
Page 37
Accessible drivesInstalling the hard disks extension box
6.2Installing the hard disks extension box
In the SCSI version the two lower 5.25 inch bays for accessible drives can be
used to install a HDD extension box. But it is required that the server is equipped
with a 1- or 2-channel RAID controller.
I It is not allowed to operate the hard disks of the HDD extension box
together with the internal hard disks via one common SCSI line.
If the server has a RAID controller and a corresponding RAID configuration,
defective hard disk modules can also be exchanged during operation.
Ê Open the server and remove the front cover or rack front cover as described
in the chapter “Preparation” on page 13 et seqq. .
I The hard disks extension box is supplied without EasyClick rails. You
need 8 M3 screws. Before installing a new hard disks extension box you
must therefore remove the EasyClick rails from the two dummy covers
and mount two of the four EasyClick rails on the hard disks extension
box.
Ê Remove the dummy covers from the two lower 5.25-inch bays for accessible
drives:
Ê Press the two metal tongues of the EasyClick rails inward (1) until the
locking mechanism is released.
Ê Remove the dummy cover from the bay.
Ê Remove the EasyClick rails from the two dummy covers by removing the four
screws on each side.
I Note that there are two M3 screws and two UNC screws on each side.
V CAUTION!
Keep the dummy covers for future use. If you remove the hard disks
extension box again and do not replace it with new drives, the dummy
covers must be reinstalled to comply with EMC regulations and to
satisfy cooling requirements and fire protection measures.
U41604-Z156-1-76Options Guide29
Page 38
Installing the hard disks extension boxAccessible drives
Figure 21: Attaching the EasyClick rails
Ê Screw the EasyClick rails onto either side of the hard disks extension box
using four M3 screws for each rail. Use the holes marked above for this
purpose.
Ê Push the hard disks extension box fully into the bay until the EasyClick rails
latch in place.
Ê Connect the power cable plug P2 to the hard disks extension box.
Ê Connect the SCSI cable T26139-Y3927-V1 included in the conversion kit to
the SCSI connector on the HDD extension box.
Ê Connect the I
2
C cable (T26139-Y3718-V601) with the I²C bus connector of
the HDD extension box..
2
Ê Secure the I
C cable with a green clamp.
Ê Route the SCSI cable and connect it to the SCSI connector on the 1- or
2-channel RAID controller.
Ê Attach the front cover or rack front cover, close the server, connect it to the
power outlet, and switch it on as described in the chapter “Completion” on
page 59 et seqq. .
30Options Guide U41604-Z156-1-76
Page 39
7Controller in the PCI slots
V CAUTION!
Observe the safety instructions in the chapter “Safety notes” on page 7
et seqq. .
The system board offers six PCI slots: 2 x PCI-X (64 Bit / 66 MHz), 3 x PCI (32
Bit / 33 MHz) and 1 x PCI-Express x1 slot.
The PCI slot 2 is prepared for Zero Channel RAID (ZCR).
PCIe Slot 6
PCI Slot 5
PCI Slot 4
PCI Slot 3
PCI Slot 2
PCI Slot 1
Figure 22: Numbering of the PCI slots
PCI slot64Bit/
32Bit
132 Bit3332-Bit PCI bus slot
264 Bit6664-Bit PCI X bus slot, prepared for ZCR
364 Bit6664-Bit PCI X bus slot
432 Bit3332-Bit PCI bus slot
532 Bit3332-Bit PCI bus slot
6PCIe x1 bus slot
For more information see the Technical Manual of the system board D1979.
U41604-Z156-1-76Options Guide31
Frequency
in MHz
Description
Page 40
Installing a controllerController in the PCI slots
7.1Installing a controller
Ê Open the server as described in the chapter “Preparation” on page 13 et
seqq. .
3
1
2
Figure 23: Removing the rear cover
Ê Swing the locking swivel in the direction of the arrow (1).
Ê Press onto the clip (2) and remove it.
Ê Remove the PCI slot’s rear cover (3).
V CAUTION!
Keep the rear cover of the PCI slot for future use. If you remove the
controller again and do not replace it with a new one, the rear cover
must be reinstalled to comply with EMC regulations and to satisfy
cooling requirements and fire protection measures.
32Options Guide U41604-Z156-1-76
Page 41
Controller in the PCI slotsInstalling a controller
a
2
1
4
Figure 24: Installing a controller
3
3
Ê Install the controller in the PCI slot and press it carefully into the associated
plug-in location on the system board (1) until it engages properly.
Ê Place the clip on the slot cover in such a way that the pin (a) fits into the hole
of the slot cover (2), and press the clip in the direction of the arrow (3) until
it engages.
Ê Swing the locking swivel (4) in its locking position.
Ê If required, connect the cables to the controller and other components.
Ê Close the server, connect it to the power outlet, and switch it on as described
in the chapter “Completion” on page 59 et seqq. .
U41604-Z156-1-76Options Guide33
Page 42
PCI slot assemblingController in the PCI slots
7.2PCI slot assembling
Install first those controllers which request a defined slot. Then install the PCIX controllers, then the PCI66 and at least the PCI33 controllers.
PCI
bus
type
1. Controller for defined slots
RemoteView service board S2 LP33112, 3
2. PCI-X controller
3. PCI 66 MHz controller
LSI MegaRaid Zero Channel66121, 3, 4, 5
LSI MegaRaid Two Channel6612, 31, 2, 4, 5
Emulex LP900SL6631, 3, 42
Qlogic QLA22006631, 3, 42
Intel Pro 1000MT Dual Port6642, 3, 4, 5
Intel Pro 1000MT Server6642, 3, 4, 5
Observe the safety instructions in the chapter “Safety notes” on page 7
et seqq. .
8.1RemoteView Service Board S2 LP
I How to configure the RSB S2 LP is described in detail in the User Guide
“RemoteView”.
The preferred mounting location for the RSB S2 is PCI slot 1.
The RSB S2 LP is connected to the system board via a power and a data cable.
The RSB S2 LP kit contains an external power supply.
U41604-Z156-1-76Options Guide35
Page 44
RemoteView Service Board S2 LPRemoteView components
Ê Open the server as described in the chapter “Preparation” on page 13 et
seqq. .
1
2
Figure 25: Connecting cables to the RSB S2 LP
Ê Connect the power cable (1) and the data cable (2) to the RSB S2 LP.
Ê Install the RSB S2 LP in PCI slot 1 as described in section “Installing a
controller” on page 32.
PCI Slot 1
BATTERY
12
Figure 26: Connecting cables to the system board
Ê Connect the data cable to the connector IPMB (1) and the power cable to the
connector RSB LP Power (2) on the system board.
36Options Guide U41604-Z156-1-76
Page 45
RemoteView componentsRemoteView Service Board S2 LP
Adapter
RSB S2 LP
1
2
3
4
Externe Stromversorgung/
external power supply
Figure 27: Connecting external cables
1connect to USB port of the server
2connect to LAN port of the network
3connect to VGA port of the server
4connect to VGA port of the monitor
U41604-Z156-1-76Options Guide37
Page 46
RemoteView Service Board S2 LPRemoteView components
Ê Connect the external cables and the external power supply as shown in
figure 27 on page 37.
Ê Close the server, connect it to the power outlet, and switch it on as described
in the chapter “Completion” on page 59 et seqq. .
38Options Guide U41604-Z156-1-76
Page 47
9External SCSI interface
V CAUTION!
Observe the safety instructions in the chapter “Safety notes” on page 7
et seqq. .
If the internal hard disks are connected via a PCI RAID controller, one channel
of the on-board controller can also be made available for connecting a peripheral cabinet SX10 via an external SCSI interface.
9.1Installing the external SCSI interface
Ê Open the server as described in the chapter “Preparation” on page 13 et
seqq. .
Figure 28: External SCSI interface
Ê Remove the rear cover of PCI slot 7 and insert the slot cover of the external
SCSI interface in this slot as described in section “PCI slot assembling” on
page 34.
Ê Attach the external SCSI interface’s connector to the SCSI channel of the
onboard SCSI controller on the system board (connector SCSI U320).
Ê Close the server, connect it to the power outlet, and switch it on as described
in the chapter “Completion” on page 59 et seqq. .
U41604-Z156-1-76Options Guide39
Page 48
Page 49
10Conversion standard PS to hot-
plug PS
V CAUTION!
Observe the safety instructions in the chapter “Safety notes” on page 7
et seqq. .
The standard power supply can be replaced by a hot-plug power supply. The
hot-plug power supply consists of up to two power supply modules. The upgrade
kit contains only one power supply module (for power supply redundancy the
second power supply module must be additionally ordered).
The upgrade kit for the hot-plug power supply consists of the following parts:
– PS cage with Power backplane (incl. power cables)
– locking rail
– one power supply unit
– dummy cover (if only one power supply module is installed, you have to
install the dummy cover in the second bay)
– several screws
– anti-tilt bracket
V CAUTION!
After installing the hot-plug power supply the SDR (sensor data record)
data base must be updated. For this sequence you need a BIOS flash
diskette. This diskette contains the newest BIOS version, the BMC
firmware and the SDR data.
Ê Write a BIOS flash diskette by down loading the required data from
Ê Open the server as described in the chapter “Preparation” on page 13 et
seqq. .
Ê Disconnect all power cables from the system board and the drives (see the
cabling plans in the Appendix).
U41604-Z156-1-76Options Guide41
Page 50
Conversion standard PS to hot-plug PS
1
Figure 29: Loosening the screws
1
Ê Remove the five screws (1) which attach the adapter plate of the standard
power supply to the housing.
2
Figure 30: Taking out the standard power supply
Ê Slide the standard power supply somewhat toward the inside (1) to detach it
from the brackets in the side cover and take it out toward the side (2).
42Options Guide U41604-Z156-1-76
Page 51
Conversion standard PS to hot-plug PS
Figure 31: Installing the Power backplane in the PS cage
Ê Insert the Power backplane in the PS cage.
Ê Push the Power backplane in direction of the arrows until the three bolts of
the PS cage engage.
Ê Fasten the Power backplane with one knurled screw (see the circle).
U41604-Z156-1-76Options Guide43
Page 52
Conversion standard PS to hot-plug PS
Figure 32: Installing the PS cage
Ê Push the PS cage from inside into the bay. In the floorstand model the Power
backplane is positioned under the top cover, and in the rack model at the
right-hand side cover (seen from front side).
V CAUTION!
Make sure that the two noses of the PS cage (see the arrows) engage in
the housing. Ensure that no damage is caused to the cables.
44Options Guide U41604-Z156-1-76
Page 53
Conversion standard PS to hot-plug PS
Figure 33: Fastening the PS cage in the housing
Ê Fasten the PS cage in the housing with one screw M3x4.5 mm (see the
circle).
U41604-Z156-1-76Options Guide45
Page 54
Conversion standard PS to hot-plug PS
Figure 34: Fastening the PS cage at the rear side
Ê Fix the locking rail with four screws (see the arrows) on the rear side of the
server..
Ê Fasten the PS cage with three screws M3x4.5 mm (see the circles) at the
rear side.
Ê Connect all power cables to the system board and the drives (see the cabling
plans in the Appendix).
46Options Guide U41604-Z156-1-76
Page 55
Conversion standard PS to hot-plug PS
Figure 35: Inserting the power supply module
Ê Push the power supply module in the left side (floorstand model) or bottom
side (rack model) bay.
Ê Lift the green handle somewhat upwards so that the forked levers (see the
arrows) can fit to the locking rail.
U41604-Z156-1-76Options Guide47
Page 56
Conversion standard PS to hot-plug PS
Figure 36: Locking the power supply module
Ê Push the green handle downward until the locking slide (see the arrow)
engages.
Ê Plug the power cord to the connector of the power supply module.
Ê If you want to install a second power supply module, proceed in the same
way.
48Options Guide U41604-Z156-1-76
Page 57
Conversion standard PS to hot-plug PS
Figure 37: Installing the dummy cover
Ê If you have not ordered a second power supply module, install the dummy
cover in the second bay:
Hook the top side of the dummy cover into the chassis, after this swivel the
dummy cover down and fasten it with one screw (see the arrow) to the
housing.
V CAUTION!
For floorstand models with hot-plug power supply the supplied anti-tilt
bracket must be fitted at the rear of the server.
U41604-Z156-1-76Options Guide49
Page 58
Conversion standard PS to hot-plug PS
Mounting the anti-tilt bracket (only floorstand model)
Ê Attach the left-hand side cover as described in section “Closing the server”
on page 61.
1
1
Figure 38: Mounting the anti-tilt bracket
Ê Position the server on the anti-tilt bracket in the way that the rubber feet of
the server fit into the openings of the bracket (1).
50Options Guide U41604-Z156-1-76
Page 59
Figure 39: Fastening the anti-tilt bracket
Conversion standard PS to hot-plug PS
Ê Fasten the anti-tilt bracket using the two knurled screws (1).
Ê Close the server, connect it to the power outlet, and switch it on as described
in the chapter “Completion” on page 59 et seqq. .
V CAUTION!
After installing the hot-plug power supply the SDR (sensor data record)
data base must be updated. For this sequence you need the BIOS flash
diskette prepared before. This diskette contains the newest BIOS
version, the BMC firmware and the SDR data.
I You will find the description of the indicators of the power supply module
in the Operating Manual for the PRIMERGY TX150 S3.
U41604-Z156-1-76Options Guide51
Page 60
Page 61
11Converting from the floorstand
model to the rack model
V CAUTION!
Observe the safety instructions in the chapter “Safety notes” on page 7
et seqq. .
Ê Open the server and remove the front cover as described in the chapter
“Preparation” on page 13ff.
I The front cover is no longer required.
Figure 40: Removing the anti-tilt bracket
Ê If your server is equipped with an anti-tilt bracket, remove it:
Ê Remove the two knurled screws (1) and lift the server out of the anti-tilt
bracket.
U41604-Z156-1-76Options Guide53
Page 62
Converting from the floorstand model to the rack model
The right-hand side cover and the top cover build one part.
Figure 41: Removing the screws
Ê Remove the two screws at the rear side.
1
Figure 42: Removing the right-hand side cover
Ê Lift the hook up slightly using a screwdriver.
Ê Push the right-hand side cover in the direction of the arrow.
Ê Lift off the right-hand side cover.
I The right-hand side cover is no longer required.
54Options Guide U41604-Z156-1-76
Page 63
Converting from the floorstand model to the rack model
Ê Lay the server on its right-hand side.
V CAUTION!
Get a second person to help you do this. The server can weigh up to 40
kg.
Figure 43: Removing the rubber feet
Ê Remove the two upper rubber feet (see the arrows) on the left side.
Ê Remove the three screws (see the circles) and take out the rail with the two
lower rubber feet.
I The rubber feet and the rail are no longer required.
U41604-Z156-1-76Options Guide55
Page 64
Converting from the floorstand model to the rack model
The drive cage for the accessible drives is constructed in such a way that the
accessible drives and the operating panel module can be taken out simply, turned through 90° to the left, and then be reinstalled.
Ê Remove the dummy covers from the drive cage (figure 15 on page 25).
Ê Unplug the cables from the system board or the accessible drives and
remove the drives from the drive cage.
Ê Pull the operating panel module forward out of its mounting location until you
can pull the the ribbon cable and the USB cable out of the operating panel
module. Remove the two cables.
Ê Remove the operating panel module.
Ê Turn the operating panel module through 90° to the left.
Figure 44: Installing the operating panel module
Ê Push the operating panel module halfway into the upper bay of the drive
cage.
Ê Connect the ribbon cable and the USB cable to the operating panel module.
Ê Now push the operating panel module fully into the upper bay of the drive
cage.
Ê Turn the drives removed beforehand through 90° to the left.
Ê Turn the dummy covers removed beforehand through 90° to the left.
Ê Install the drives and empty covers in the drive cage.
Ê Reestablish all connections to the drives.
56Options Guide U41604-Z156-1-76
Page 65
Converting from the floorstand model to the rack model
Ê Attach the rack front cover, close the server, connect it to the power outlet,
and switch it on as described in the chapter “Completion” on page 59ff.
To enable the rack model to be presented correctly in ServerView, proceed as
follows:
Ê Place the ServerStart CD-ROM in the drive.
Ê Under the path \Tools\System Configuration start the SCU_Chassis
Model Conversion program and change the server type to "PRIMERGY
TX150S3 Rack".
U41604-Z156-1-76Options Guide57
Page 66
Page 67
12Completion
V CAUTION!
Observe the safety instructions in the chapter “Safety notes” on page 7
et seqq. .
12.1Floorstand model
12.1.1 Attaching the hard disk cover
After you have installed further SATA hard disk drives, reattach the hard disk
cover.
1
Figure 45: Attaching the hard disk cover
Ê Push the drive cover up as far as possible (1).
Ê Reinsert the hard disk cover (2 + 3).
Ê Insert the key.
Ê Lock the server.
Ê Press the on/off key to start up the server.
U41604-Z156-1-76Options Guide59
2
3
Page 68
Floorstand modelCompletion
12.1.2 Attaching the front cover
After you have installed further accessible drives, reattach the front cover.
2
1
3
Figure 46: Attaching the front cover
Ê Press the two hooks (1) on the right side in the recesses of the housing.
Ê Press the front cover onto the housing (2) until the three tabs on the left side
engage (3).
Ê Attach the hard disk cover as shown in figure 45 on page 59.
60Options Guide U41604-Z156-1-76
Page 69
CompletionFloorstand model
12.1.3 Closing the server
1
2
Figure 47: Attaching the left-hand side cover
Ê Position the left-hand side cover in such a way that it protrudes approxiate
2 cm at the rear (1). Shut the left-hand side cover.
Ê Push the left-hand side cover all the way forward (2).
1
Figure 48: Fastening the left-hand side cover
Ê Fasten the left-hand side cover with two screws (1).
Ê Insert the key.
Ê Lock the server.
Ê Connect all power plugs to the power outlets.
Ê Press the on/off key to start up the server.
U41604-Z156-1-76Options Guide61
Page 70
Rack modelCompletion
12.2Rack model
12.2.1 Attaching the rack front cover
Reattach the rack front cover after implementing the following extensions:
– Installation of further accessible drives
– Conversion of the floorstand model to a rack model
3
2
1
Figure 49: Attaching the plastic front cover
Ê Press the two hooks (1) on the bottom side in the recesses of the housing.
Ê Press the plastic front cover onto the housing (2) until the three tabs on the
top side engage (3).
62Options Guide U41604-Z156-1-76
Page 71
CompletionRack model
2
1
2
Figure 50: Attaching the rack front cover
Ê Attach the rack front cover from the front (1).
Ê Attach the rack front cover using two screws on each side (2).
U41604-Z156-1-76Options Guide63
Page 72
Rack modelCompletion
12.2.2 Closing the server
1
2
2
3
Figure 51: Attaching the top cover
Ê Position the top cover in such a way that it protrudes approxiate 2 cm at the
rear (1).
Ê Push the top cover all the way forward (2).
Ê Fasten the top cover with two screws (3).
64Options Guide U41604-Z156-1-76
Page 73
CompletionRack model
If you have not removed the server from the rack cabinet, please skip this page.
V CAUTION!
At least two people are required to install the server in the rack cabinet.
Do not use the handles on the rack front cover to lift the server into the
rack.
Ê Lower the server from above onto the extended telescopic rails.
2
Figure 52: Installing the server in a rack cabinet
Ê Screw the telescopic rails onto the left-hand side (one screw) and right-hand
side (two screws) of the server.
Ê Reconnect all the cables you disconnected beforehand on the rear of the
server.
Ê Press in the locking spring on both sides and push the server as far as it will
go into the rack.
U41604-Z156-1-76Options Guide65
Page 74
Rack modelCompletion
1
Figure 53: Fastening the server in the rack cabinet
Ê Fasten the server in the rack using the four knurled screws (1).
Ê Connect all power plugs to the power outlets.
Ê Press the on/off key to start up the server.
66Options Guide U41604-Z156-1-76
Page 75
13Appendix
13.1Cabling
I The Pn numbers of the power cables are identical for the standard and
the redundant power supply. You will not find a special drawing for the
power supply cabling.
13.1.1 SCSI version
1-channel SCSI version with onboard SCSI controller
In the basic version the tape drives and the four internal hard disk drives are
connected to the onboard SCSI controller via one SCSI cable.
1-channel SCSI version with additional SCSI RAID controller
A SCSI RAID controller is installed into a PCI slot and connected with the four
internal hard disk drives.
In this case, the connection to the onboard SCSI controller must be changed to
the RAID controller. The accessible drives must be unplugged from this SCSI
cable.
After this the accessible drives can be connected to the onboard SCSI controller
via an additional SCSI cable.
Supplementary channels of the RAID controller are available for external hard
disk drive systems.
U41604-Z156-1-76Options Guide67
Page 76
CablingAppendix
SCSI
device
SCSI
device
P3
P5
Floppy
Floppy
IDTEMP
Y1248-V8
1" HDD
SCSI HD ID3
SCSI HD ID2
X6
P6
SCSI HD ID1
X7
SCSI HD ID0
X5
SCSI backplane
1-channel
Intrusion sw.
Intrusion sw.
CD/DVD
P4
Operating panel
USB
Y3904-V1
Y3912-V1
P2
Y1737-V111
P8
P1
Power supply
P9
Figure 54: Cabling 1-channel SCSI version with onboard SCSI controller
Y3736-V1
Y3785-V301
Y3718-V508
System
fan
Power
SCSI
IDE/FD
Y3728-V1
Legend:
Data
Cable prefix: T26139-
68Options Guide U41604-Z156-1-76
Page 77
AppendixCabling
P3
Floppy
SCSI
device
Floppy
P5
IDTEMP
free
Y1248-V8
P9
1" HDD
SCSI HD ID3
SCSI HD ID2
X6
P6
Intrusion sw.
Y3736-V1
Y3859-V11
SCS HD ID1
X7
Intrusion sw.
Y3718-V508
SCSI HD ID0
X5
Y3785-V301
Y2361-V102
SCSI backplane
1-channel
SCSI RAID
controller
SCSI
device
CD/DVD
Operating panel
P4
USB
Y3904-V1
Y3912-V1
P2
Y1737-V111
P8
P1
System
fan
Power
SCSI
IDE/FD
Power supply
Legend:
Y3728-V1
Data
Cable prefix: T26139-
Figure 55: Cabling 1-channel SCSI version with additional SCSI RAID controller
U41604-Z156-1-76Options Guide69
Page 78
CablingAppendix
Hard disk
extension
CD/DVD
Operating panel
P4
USB
Y3904-V1
Y3912-V1
Y1737-V111
P8
box
P2
P3
Y3927-V1
RAID
P1
Floppy
Floppy
P5
IDTEMP
Y1248-V8
controller
P9
1" HDD
SCSI HD ID3
SCSI HD ID2
X6
P6
SCSI HD ID1
X7
Y3785-V301
Y3718-V508
SCSI HD ID0
X5
SCSI backplane
1-channel
Intrusion sw.
Intrusion sw.
Y3736-V1
System
fan
Power
SCSI
IDE/FD
Power supply
Y3728-V1
Data
Legend:
Figure 56: Cabling hard disk extension box
70Options Guide U41604-Z156-1-76
Cable prefix: T26139-
Page 79
AppendixCabling
13.1.2 SATA version
SCSI
SCSI
CD/DVD
P2
P4
Operating panel
USB
Y3904-V1
Y3912-V1
device
device
P3
P5
Floppy
Floppy
IDTEMP
1" HDD
SATA HD 3
SATA HD 2
SATA HD 1
SATA HD 0
X6
X4
X9
X8
P6
free
X2
X10
SATA backplane
X11
Y1737-V111
P8
P1
Power supply
Y1248-V8
P9
Figure 57: Cabling with additional SATA controller
PRIMERGY manuals are available as PDF file on the ServerBooks CD. The
ServerBooks CD is part of the ServerView Suite delivered with each server
system.
The actual version of the necessary manuals can be downloaded free of charge
from the Internet. The overview page showing the online documentation
available in the Internet can be found via the URL:
http://manuals.fujitsu-siemens.com (choose: intel based servers/PRIMERGY
ServerBooks).
[1]Safety
[2]Warranty
[3]PRIMECENTER Rack
Technical Manual
[4]DataCenter Rack
Technical Manual
[5]19 inch rack
Technical Manual
[6]PRIMERGY ServerView Suite
ServerStart
[7]ServerView
Server Management
User Manual
[8]ServerView Extension
ServerView Extension for HP OpenView NNM
[9]ServerView/Plus for Tivoli
[10]RemoteView
User Manual
[11]PRIMERGY TX150 S3
Operating Manual
[12]System Board D1979
Technical Manual
[13]BIOS-Setup
Reference Manual
U41604-Z156-1-76Options Guide79
Page 88
Related Publications
[14]Integrated Mirroring
User’s Guide
[15]Global Array Manager Client Software
User’s Guide
[16]Configurator
For partners and distributors only:
http://extranet.fujitsu-siemens.com/cafe/products/primergy
80Options Guide U41604-Z156-1-76
Page 89
Index
A
accessible drives 3, 25
C
controller 3, 32
conversion of floorstand module to
rack model 4
conversion standard power supply to
hot-plug power supply 4
Conversion standard PS to hot-plug
PS 41
E
ESD (devices sensitive to electrostatic
discharge) 12
external SCSI interface 3, 39
F
floorstand to rack model
conversion 53
front cover 14, 60
H
hard disk cover 15, 59
hard disks extension box 3, 29
I
information material 2
R
rack front cover 19, 62
RemoteView Service Board S2 LP 3,
35
S
SATA hard disk drives 2
T
target group 1
L
light-emitting diode (LED) 11
lithium battery 10
M
main memory 2, 21
meaning
of the symbols 4
N
notational conventions 4
note about the laser 11
U41604-Z156-1-76Options Guide81
Page 90
Page 91
Fujitsu Siemens Computers GmbH
User Documentation
81730 München
Germany
On April 1, 2009, Fujitsu became the sole owner of Fujitsu Siemens Computers. This new subsidiary of Fujitsu has been renamed Fujitsu Technology Solutions.
This document from the document archive refers to a product version which
was released a considerable time ago or which is no longer marketed.
Please note that all company references and copyrights in this document have
been legally transferred to Fujitsu Technology Solutions.
Contact and support addresses will now be offered by Fujitsu Technology Solutions and have the format …@ts.fujitsu.com.
The Internet pages of Fujitsu Technology Solutions are available at
http://ts.fujitsu.com/...
and the user documentation at http://manuals.ts.fujitsu.com.
Copyright Fujitsu Technology Solutions, 2009
Hinweise zum vorliegenden Dokument
Zum 1. April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von
Fujitsu übergegangen. Diese neue Tochtergesellschaft von Fujitsu trägt seitdem den Namen Fujitsu Technology Solutions.
Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine
bereits vor längerer Zeit freigegebene oder nicht mehr im Vertrieb befindliche
Produktversion.
Bitte beachten Sie, dass alle Firmenbezüge und Copyrights im vorliegenden
Dokument rechtlich auf Fujitsu Technology Solutions übergegangen sind.
Kontakt- und Supportadressen werden nun von Fujitsu Technology Solutions
angeboten und haben die Form …@ts.fujitsu.com.
Die Internetseiten von Fujitsu Technology Solutions finden Sie unter
http://de.ts.fujitsu.com/..., und unter http://manuals.ts.fujitsu.com finden Sie die