Fuji Electric Portaflow X Data sheet

PortaFlow-X
Portable, Accurate Transit-Time Flow Measurement
The Portaow-X is a portable ultrasonic ow meter utilizing the transit-time difference principle for measuring ow rates through pipes from the outside. It’s compact and
lightweight, and incorporates the latest breakthroughs in digital signal processing and electronics realizing high performance and easy operation. The most attractive advantage
of the Portaow-X is the non-invasive setup, enabling multiple ow measurements of different running systems, and offering a signicant cost advantage over time. Some of the most common applications include: backup for an already installed ow meter system, water supply and sewage treatment, ow measurement systems, boilerwater/
feedwater supplies, cooling water, cooling oil, and deionized water for semiconductor manufacturing, among others. The meter may be set up with a wide variety of sensors from small diameters to large diameters, over a wide temperature range.
Features
Large LCD backlit display – both flow
rates and totalizing functions may be viewed together
Simple setup and easy operation
typical setup takes approximately 10 minutes
Sound velocity measuring function
eliminates temperature and pressure errors, and enables easy setup for unknown materials
Enhanced anti-bubble measurement
technology (ABM) – removes the effect of
entrapped and suspended flow bubbles
Compact and light-weight – weighs only
3.3 lbs
Built-in data logger – direct download to
PC spreadsheet applications
High accuracy – ±0.5% to ±1.0% of
velocity typical on calibrated system
Variety of detectors – for small and large
diameter pipes ranging from 0.50 to 235 in.
Performance Specications for the Converter
Fluid Conditions
Measured fluid
(water, sea water, hydro-carbons or uid
of unknown sound velocity) capable of ultrasonic wave propagation
Fluid turbidity 10000 deg. (mg/l) or less State of flow Axis-symmetric ow in pipe
lled with uid
Velocity range 0.06 to 105 ft/sec (.018 to 32
m/sec) bi-directional ow
Fluid temperature
Standard temperature detector
212°F (-40 to 100°C)
High temperature detector -40 to 390°F
(-40 to 200°C)
Piping Conditions
Pipe material
Homogeneous liquids
-40 to
Carbon steel, stainless steel,
cast iron, copper, pvc, aluminum, ductile iron, asbestos, frp, peek, pvdf, acrylic and other. If other is selected, pipe materials with a sonic velocity range of 3280 to 12136 ft/sec (1000 to 3700 m/sec) can be selected via the keypad (sonic velocity information for several pipe materials is included in the Operator Manual)
Pipe size Small pipe range detector:
0.50 to 4.0 in. (13 to 100mm); Standard pipe range detector: 2.0 to 16 in. (50 to 400mm); Universal pipe range detector:
8.0 to 48 in. (200 to 1200mm); Large pipe range detector: 8.0 to 235 in. (200 to 6000mm); High-Temperature detector: 2.0 to 16 in. (50 to 400mm)
Lining material Tar, epoxy, mortar, rubber,
Teon, glass, pvc, other, or none. If other
is selected, liner materials with a sonic velocity range of 3280 to 12136 ft/sec (1000 to 3700 m/sec) can be selected via the keypad (sonic velocity information for several liner materials is included in the Operator Manual)
Fluid type Water, sea water or other. If other
is selected, a sonic velocity range of 1640 to 8200 ft/sec (500 to 2500 m/sec) can be selected via the keypad (sonic velocity
information for several uids is included in
the Operator Manual)
Measurement Accuracy
Accuracy
Linearity 0.1% of scale Repeatability 0.5% or better
±0.5% to ±1.0% of velocity for velocities >1.0 ft/sec. typical on calibrated system; ±1.5% to ±2.0% of velocity for velocities <1.0 ft/sec. typical on calibrated system
(Calibrated system conditions include a minimum of 10 inner pipe diameters of upstream straight pipe run and a minimum of 5 inner pipe diameters of downstream pipe run. Longer runs may be necessary due to pipe configurations.)
Ultrasonic Flow Meters Fuji PortaFlow-X
Key Features
Large LCD backlit display
Simple setup and easy operation
Sound velocity measuring function
Enhanced anti-bubble measurement
Compact and light-weight
Wide pipe range: 0.5 to 235 in.
Information subject to change without notice. Prices in USD.
082106
PortaFlow-X
Specications (continued)
Physical Specications for the Converter
Ambient temperature Without printer: 14
to 131°F (-10 to 55°C) ; With printer: 14 to 113°F (-10 to 45°C)
Ambient Humidity less than 90% RH Enclosure High impact thermoplastic, gray
in color, dust-proof (NEMA 3, IP52)
Dimensions Without printer: 9.45H x 5.00W
x 2.75D in. (240 x 127 x 70mm); With printer: 14.13H x 5.00W x 2.75D in. (359 x 127 x 70mm)
Weight Without printer: 3.3 lbs. (1.5kg); With
printer: 4.4 lbs. (2.0kg)
Functional Specications for the Converter
Power supply Built-in battery or external
power adapter
Built-in battery Special NiCd, Continuous
operation: 5 hrs. (without optional printer and back light). Recharging time: 3 hrs. (with supplied external power adapter)
Power adapter External power adapter,
input: 90 to 264V AC, 50/60 Hz
Output 17.5V DC, 1.2 A Power consumption 12 W or less (without
optional printer)
LCD display 4.0H x 3.0W in. (102 x 76mm),
high resolution, 240 x 320 dot graphic with back light (back light invoked via “LIGHT” button on front panel)
Keypad 10 keys (ON, OFF, ESC, ENT,
LIGHT, PRINT
LED indicators DC IN (green), FAST
CHARGE (red)
Power down backup Ram memory backed
up by lithium battery (effective term, 5 yrs)
Response time 1 sec. or less Output signal 0.8-20 mA DC, 4-20mA DC,
20-4-20mA DC, max. load resistance 1K ohms
Information subject to change without notice. Prices in USD.
g,f,h,i)
Input signal 4-20mA DC Serial communication RS-232C, even,
odd or no parity, 1 or 2 stop bits, keypad selectable; Transmission speed: 300, 600, 1200, 2400, 4800 or 9600BPS, keypad selectable; Transmission distance: max. 50 ft. (15m)
Printer (option) Thermal serial dot printing
(8 x 256 dots), mounts to top of converter
Display language English, German,
French, Japanese (Katakana) and keypad selectable
Measurement display screen Flow velocity
and rate (with ow direction) displayed
simultaneously. Flow rate units are selectable via keypad; Units: English or Metric system keypad selectable; English
system units: ow velocity in ft/sec, ow
rate units: gal/sec, gal/min, gal/hr, Mgal/ day, ft3/sec, ft3/min, ft3/hr, Mft3/day, bbl/ sec, bbl/min, bbl/hr, Mbbl/day; (gal = U.S.
gallons); Metric system units: ow velocity in m/sec, ow rate units: l/s, l/min, l/h, Ml/d,
m3/sec, m3/min, m3/h, m3/day, Mm3/day, bbl/sec, bbl/min, bbl/hr, Mbbl/day
Totalizer display screen Forward and
reverse totalizer values displayed simultaneously. Totalizer units are selectable via keypad; English system units: gal, Kgal, ft3, kft3, Mft3, bbl, Kbbl, Mbbl (gal = U.S. gallons); Metric system units: ml, l, m3, km3, Mm3, bbl, Kbbl, Mbbl
Clock display function Time (year, month,
day, hour, minute) display and setting, keypad selectable
Damping 0 to 99 sec. (time constant),
keypad selectable
Low flow cutoff 0 to 3.30 ft/sec (0 to 1.0
m/sec), keypad selectable
Output setting function Current output
scaling, output type: (0.8-20 mA, 4-20 mA, 20-4-20 mA), output calibration and burn out setting (output selectable to hold last
value, force zero, high or low), keypad selectable
Communication function Data logger le
transfer, ow velocity, forward and reverse
totalizer values, date/time and error status transmission on request from host
Data logging function Site data which
includes site name, piping, uid type,
sensor type and mounting method. Up to 20 sites and a maximum of 40,000 data
points (ow velocity, ow rate, forward and
reverse totalizer values) can be stored in battery backed-up memory
Waveform display function Oscilloscope
display of upstream and downstream received signals
Error message library Denes all error
messages and recommends solutions for resolving error
Graph display function Display of logged
data and ow rate trend graphs
Printing function Printout of screen
(invoked from “PRINT” button on front
panel), xed cycle printout including ow velocity, ow rate, forward and reverse
totalizer values, error status, logged data trend graph, date/time, site setup and diagnostic waveforms. Printing functions are active only when optional printer is installed.
Transmit output voltage X1, X2, X4 and
X8 transmit output voltages, keypad
selectable
Detector Models FLD
Mounting method V or Z method mounted
to outside of pipe by means of steel bands, nylon belts or steel wire
Straight pipe length Upstream side, 10d or
more, downstream side, 5d or more (d = inside pipe diameter).
Signal cable RG-58 or RG-58A/U, 50 ohm
coaxial cable
Cable length Standard length 16 ft.,
maximum length 1000 ft. (300m)
Connection Converter: BNC connectors
(female). Detector models FLD22, FLD32, FLD11: BNC connectors (female). Detector Models FLD12, FLD41, FLD50: internal terminal screw, strain-relieved, water-resistant, water-proof optional
Pipe diameter range
FLD22 (Small diam. pipe range): 0.50 to 4.0 in. (13 to 100mm). FLD12 (Small diam. pipe range): 2.0 to 16 in. (50 to 400mm). FLD11 (Standard pipe range):
2.0 to 16 in. (50 to 400mm). FLD41 (Universal pipe range): 8.0 to 48 in. (200 to 1200mm). FLD50 (Large diameter pipe range): 8.0 to 235 in. (200 to 6000mm).
082106
Loading...
+ 3 hidden pages